Home
EUROLITE SB-1100 User Manual
Contents
1. instructions and warning notes written in this user manual Important JE Damages caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability for any resulting defects or problems If the device has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperature Please make sure that there are no obvious transport damages Should you notice any damages on the A C connection cable or on the casing do not take the device into operation and immediately consult your local dealer 10 15 00026727 DOC Version 2 1 This device falls under protection class The CEKON plug must only be plugged into a CEKON outlet The voltage and frequency must exactly be the same as stated on the device Wrong voltages or power outlets can lead to the destruction of the device and to mortal electrical shock Always plug in the power supply plug least The power plug must always be inserted without force Make sure that the plug is tightly connected with the outlet Never let the power cord come into contact with other cables Handle the power cord and all connections with the mains with particular caution Never touch them with wet hands as this could lead to mortal electrical shock Never modify bend strain mechanically put pressure on
2. pull or heat up the power cord Never operate next to sources of heat or cold Disregard can lead to power cord damages fire or mortal electrical shock The cable insert or the female part in the device must never be strained There must always be sufficient cable to the device Otherwise the cable may be damaged which may lead to mortal damage Make sure that the power cord is never crimped or damaged by sharp edges Check the device and the power cord from time to time If extension cords are used make sure that the core diameter is sufficient for the required power consumption of the device All warnings concerning the power cords are also valid for possible extension cords Always disconnect from the mains when the device is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord Otherwise the cable or plug can be damaged leading to mortal electrical shock If the power plug or the power switch is not accessible the device must be disconnected via the mains If the power plug or the device is dusty the device must be taken out of operation disconnected and then be cleaned with a dry cloth Dust can reduce the insulation which may lead to mortal electrical shock More severe dirt in and at the device should only be removed by a specialist There must never enter any liquid into power outlets extension cords or any holes in the housing of the device If you suppose th
3. sind Wird das Ger t anders verwendet als in dieser Bedienungsanleitung beschrieben kann dies zu Schaden am Produkt f hren und der Garantieanspruch erlischt Au erdem ist jede andere Verwendung mit Gefahren wie z B Kurzschluss Brand elektrischem Schlag Abst rzen verbunden 5 15 00026727 DOC Version 2 1 4 GERATEBESCHREIBUNG 4 1 Features Praktischer 32A Stromverteiler im 19 Geh use Besonders geeignet zum Aufbau gro er Stromverteilungen Zum Rackeinbau werden nur 3 HE ben tigt 32A Drehstrom Eingang ber Anschlu leitung und Stecker 32A Drehstrom Ausgang ber Gerateanbausteckdose auf der R ckseite mit Fl abgesichert Der Gesamte Verteiler ist ber einen 30mA FI abgesichert 2 CEKON Ger teanbausteckdosen 16A auf der Frontseite abgesichert ber 3x16A Sicherungsbl cke Kontrollleuchten f r die Pr senz jeder einzelnen Phase 6 Schutzkontaktsteckdosen auf der R ckseite des Ger tes 2 pro Phase Jedes Steckdosenpaar ist mit einem eigenen 16A Automaten abgesichert Mit Erdungsschraube um ggf ein Rigg erden zu k nnen 4 2 Ger te bersicht INPUT AC380 400V 50Hz 1 32A Drehstrom Eingangsstecker 2 32A Drehstrom Ausgangsdose 3 Phase 1 Steckdosen 4 Phase 2 Steckdosen 5 Phase 3 Steckdosen 6 19 Gehause 6 15 00026727 DOC Version 2 1 o eurolite SB 1100 e c REM ECH PREECI A SPFUSECI A SF
4. T EN issiissecssscesucssscieteviaeiwcdsadsenessiceaseviaccanavazeaviveceasannicceau tin danvesnecaayenieansaezedssaneeusnaaussuusnncunys 9 1 INTRODUCTION m 10 2 SAFETY INSTRUCTIONS 5 reas eccacaepe cavae cos kx vk eaa vaso Ead oc saa v Sra aan RR EDGE ga RECEN Ra DDR RR RR SOR R E RERRN 10 3 OPERATING DETERMINATIONS eeeeeeeeeee nnns kann nnn na naa kk aaa ea RR R RR RR RR KEN RR RR GEAR RR RR R R44 KEEN KREE KENE 11 LaMuzeuiinee aE ia 12 LN SION 12 4 2 Description of the device nenn tanAAn anren anAn ananena rannan nanenane 13 5 INSTALLATION E 14 541 Rack Installation TER t 14 5 2 GONNECHORS TETTE Em 14 6 CLEANING AND MAINTENANCE 22uu200 220000nn0nnnnnnanunnnnnnnnnnnnnnnnnnannnnnnnnnnnnnnnnnnnnnannnn nn nnnnn nn nnnnnnnn nun daa dad uu 14 7 TECHNICAL SPECIFICATIONS u cccccesccssssecceesesecneeseeeseseeeeusueseeeeeeeneauseeeneusseeenueeeeuuueseeeuaueseaugesesnagseeees 15 Das neueste Update dieser Bedienungsanleitung finden Sie im Internet unter You can find the latest update of this user manual in the Internet under www eurolite de 2 15 00026727 DOC Version 2 1 Deutsch BEDIENUNGSANLEITUNG euros SB 1100 19 Unterverteilung 39A Alle Personen die mit der Aufstellung Inbetriebnahme Bedienung Wartung und Instandhaltung dieses Ger tes zu tun haben
5. USESCI A Oi E oO B 16A OUTPUT 1 16A OUTPUT 2 DR L3 16A OUTPUT 1 16A OUTPUT 2 oO e oO 11 10 9 8 7 7 2x 16A Drehstrom Ausgangsdose 8 Leitungsschutzschalter f r Schutzkontaktsteckdose R ckseite 9 3x 16A Leitungsschutzschalter f r Drehstrom Vorderseite 10 Fehlerstromschutzschalter FI 11 Phasen Kontrollleuchten 5 INSTALLATION und DIN 15560 zu beachten Die Installation darf nur vom autorisierten Fachhandel ausgef hrt werden LEBENSGEFAHR N Bei der Installation sind insbesondere die Bestimmungen der BGV C1 vormals VBG 70 Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen vor der ersten Inbetriebnahme und nach wesentlichen nderungen vor der Wiederinbetriebnahme durch Sachverst ndige gepr ft werden Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens alle vier Jahre durch einen Sachverst ndigen im Umfang der Abnahmepr fung gepr ft werden Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens einmal j hrlich durch einen Sachkundigen gepr ft werden Vorgehensweise Die Installation sollte idealerweise au erhalb des Aufenthaltsbereiches von Personen angebracht werden 7115 00026727 DOC Version 2 1 5 1 Rackinstallation Dieser 19 Unterverteilung 32A ist f r ein 19 Rack Stahlschrank 483 mm vorgesehen Be
6. als berschritten werden darf LEBENSGEFAHR Vor der ersten Inbetriebnahme muss die Einrichtung durch einen Sachverst ndigen gepr ft werden 6 REINIGUNG UND WARTUNG Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens alle vier Jahre durch einen Sachverstandigen im Umfang der Abnahmepr fung gepr ft werden Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens einmal jahrlich durch einen Sachkundigen gepr ft werden Dabei muss unter anderem auf folgende Punkte besonders geachtet werden 1 Alle Schrauben mit denen das Ger t oder Ger teteile montiert sind m ssen fest sitzen und d rfen nicht korrodiert sein 2 Die elektrischen Anschlussleitungen d rfen keinerlei Besch digungen Materialalterung z B por se Leitungen oder Ablagerungen aufweisen Weitere auf den jeweiligen Einsatzort und die Nutzung abgestimmte Vorschriften werden vom sachkundigen Installateur beachtet und Sicherheitsm ngel behoben LEBENSGEFAHR Vor Wartungsarbeiten unbedingt allpolig vom Netz trennen Das Ger t sollte regelm ig von Verunreinigungen wie Staub usw gereinigt werden Verwenden Sie zur Reinigung ein fusselfreies angefeuchtetes Tuch Auf keinen Fall Alkohol oder irgendwelche L sungsmittel zur Reinigung verwenden 8 15 00026727 DOC Version 2 1 Im Ger teinneren befinden sich keine zu wartenden Teile Wartun
7. an spruch F r daraus resultierende Folgesch den bernimmt der Hersteller keine Haftung Das Ger t darf nicht in Betrieb genommen werden nachdem es von einem kalten in einen warmen Raum gebracht wurde Das dabei entstehende Kondenswasser kann unter Umst nden Ihr Ger t zerst ren Lassen Sie das Ger t solange uneingeschaltet bis es Zimmertemperatur erreicht hat 3 15 00026727 DOC Version 2 1 Bitte berpr fen Sie vor der ersten Inbetriebnahme ob kein offensichtlicher Transportschaden vorliegt Sollten Sie Sch den an der Netzleitung oder am Geh use entdecken nehmen Sie das Ger t nicht in Betrieb und setzen sich bitte mit Ihrem Fachh ndler in Verbindung Der Aufbau entspricht der Schutzklasse I Der CEKON Stecker darf nur an eine CEKON Steckdose angeschlossen werden deren Spannung und Frequenz mit dem Typenschild des Ger tes genau bereinstimmt Ungeeignete Spannungen und ungeeignete Steckdosen k nnen zur Zerst rung des Ger tes und zu t dlichen Stromschl gen f hren Den CEKON Stecker immer als letztes einstecken Der Netzstecker muss dabei gewaltfrei eingesetzt werden Achten Sie auf einen festen Sitz des Netzsteckers Lassen Sie die Netzleitung nicht mit anderen Kabeln in Kontakt kommen Seien Sie vorsichtig beim Umgang mit Netzleitungen und anschl ssen Fassen Sie diese Teile nie mit feuchten H nden an Feuchte H nde k nnen t dliche Stromschl ge zu Folge haben Netzleitungen nicht ver ndern knicken mechanis
8. at also a minimal amount of liquid may have entered the device it must immediately be disconnected This is also valid if the device was exposed to high humidity Also if the device is still running the device must be checked by a specialist if the liquid has reduced any insulation Reduced insulation can cause mortal electrical shock There must never be any objects entering into the device This is especially valid for metal parts If any metal parts like staples or coarse metal chips enter into the device the device must be taken out of operation and disconnected immediately Malfunction or short circuits caused by metal parts may cause mortal injuries The total weight of the installation total weight of all individual parts must never exceed the maximum load of the installation area Keep away children and amateurs Never leave this device running unattended 3 OPERATING DETERMINATIONS This device is a power distributor for for supplying current to other devices This product is only allowed to be operated with an alternating voltage of 380 400 V 50 Hz and was designed for indoor use only This device is designed for mobile use via a lighting stand and for permanent installations via trussing system 11 15 00026727 DOC Version 2 1 The maximum power consumption of this device must never be exceeded When choosing the installation spot please make sure that the device is not exposed to extreme heat moisture or dust Th
9. atedly be approved in accordance with the instructions given in the electro technical guidelines A qualified electrician is responsible for the correct examinations Mobile electrical devices extension cords with plugs power cables with plugs and mobile cables with plugs and permanent installation must be approved by an expert every three months Should you have further questions please contact your dealer 7 TECHNICAL SPECIFICATIONS 6 2 kg Please note Every information is subject to change without prior notice 30 09 2008 eu fO S Germany 15 15 00026727 DOC Version 2 1
10. ch belasten durch Druck belasten ziehen erhitzen und nicht in die N he von Hitze oder K ltequellen bringen Bei Missachtung kann es zu Besch digungen der Netzleitung zu Brand oder zu t dlichen Stromschl gen kommen Die Kabeleinf hrung oder die Kupplung am Ger t d rfen nicht durch Zug belastet werden Es muss stets eine ausreichende Kabell nge zum Ger t hin vorhanden sein Andernfalls kann das Kabel besch digt werden was zu t dlichen Stromschl gen f hren kann Achten Sie darauf dass die Netzleitung nicht gequetscht oder durch scharfe Kanten besch digt werden kann berpr fen Sie das Ger t und die Netzleitung in regelm igen Abst nden auf Besch digungen Werden Verl ngerungsleitungen verwendet muss sichergestellt werden dass der Adernquerschnitt f r die ben tigte Stromzufuhr des Ger tes zugelassen ist Alle Warnhinweise f r die Netzleitung gelten auch f r evtl Verl ngerungsleitungen Ger t bei Nichtbenutzung und vor jeder Reinigung vom Netz trennen Fassen Sie dazu den Netzstecker an der Griffl che an und ziehen Sie niemals an der Netzleitung Ansonsten kann das Kabel und der Stecker beschadigt werden was zu t dlichen Stromschlagen f hren kann Sind Stecker oder Ger teschalter z B durch Einbau nicht erreichbar so muss netzseitig eine allpolige Abschaltung vorgenommen werden Wenn der Netzstecker oder das Ger t staubig ist dann muss es au er Betrieb genommen werden der Stromkreis muss allpolig unterbroc
11. en ohne vorherige Ankiindigung und Irrtum vorbehalten 30 09 2008 euro e erman 9 15 00026727 DOC Version 2 1 LE USER MANUAL euro e 1100 19 Distrib 2 SB 1100 19 Distributor 32A For your own safety please read this user manual carefully before you initially start up Every person involved with the installation operation and maintenance of this device has to be qualilfied follow the instructions of this manual consider this manual to be part of the total product keep this manual for the entire service life of the product pass this manual on to every further owner or user of the product download the latest version of the user manual from the Internet 1 INTRODUCTION Thank you for having chosen a EUROLITE SB 1100 19 distributor 32A If you follow the instructions given in this manual we are sure that you will enjoy this device for a long period of time Unpack your SB 1100 Before you initially start up please make sure that there are no transport damages Should there be any do not take the device into operation and immediately consult your dealer 2 SAFETY INSTRUCTIONS CAUTION Be careful with your operations With a dangerous voltage you can suffer a dangerous electric shock when touching the wires This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety
12. ere should not be any cables lying around You endanger your own and the safety of others This device must never be operated or stockpiled in sourroundings where splash water rain moisture or fog may harm the device Moisture or very high humidity can reduce the insulation and lead to mortal electrical shocks When using smoke machines make sure that the device is never exposed to the direct smoke jet and is installed in a distance of 0 5 meters between smoke machine and device The ambient temperature must always be between 5 C and 45 C Keep away from direct insulation particularly in cars and heaters The relative humidity must not exceed 50 with an ambient temperature of 45 C This device must only be operated in an altitude between 20 and 2000 m over NN The ambient contamination must never exceed level 1 and must not be conducting only dry Never use the device during thunderstorms Over voltage could destroy the device Always disconnect the device during thunderstorms Make sure that the area below the installation place is blocked when rigging derigging or servicing the fixture Operate the device only after having familiarized with its functions Do not permit operation by persons not qualified for operating the device Most damages are the result of unprofessional operation Never use solvents or aggressive detergents in order to clean the device Rather use a soft and damp cloth Please use the original packaging i
13. euro e BEDIENUNGSANLEITUNG USER MANUAL SB 1100 19 Distributor 32A e eurolite SB 1100 gt FAULT CURRENT CIRCUIT BREAKER 32A 30mA 1 16A OUTPUT 1 16AOUTPUT2 g D A S C e 16A OUTPUT 1 16A OUTPUT 2 e 3 P FUSE C16A 3 P FUSE C16A 3 FUSES C16A een De Copyright Fur weiteren Gebrauch aufbewahren Nachdruck verboten Keep this manual for future needs Reproduction prohibited MULTI LANGUAGE INSTRUCTIONS Inhaltsverzeichnis Table of contents d EE Tl 81 AUT RERO TRE ERPRIMIR 3 2 SICHERHEITSHINWEISE 1 eeeeeeeeeeee nennen nnne nn nna mun KREE KEEN RR RR RR RAN RE RR RR R RAN NR RR ann RR ERAN KEREN KKK R 4 da 4S 3 3 BESTIMMUNGSGEM RE VERWENDUNG ccecccecececceseeceeceeseceseeeecceenceenceensecaeecacececesanseeeseneeseseneeess 5 4 GERATEBESCHREIBUNG 5 rhet pne rane ted nean Cmu Xe ce Deb Ent en vos naa Er Race egenen 6 AN iad EPISCO RT TTD TD 6 SEET ee eebe 6 5 INSTALLATION t 7 5 1 E EE ET SE 8 D2 ANSCINESSC ETT eebe ege 8 6 REINIGUNG UND WARTIUIN Gk veins sasecteicscisscccasccvesccctacevanccaussacecdea cccadaascceanecessaseeaccaaviaseasasivecsaadeuncanavassasancuans 8 T TECHNISCHE DA
14. f the device is to be transported Inspection deadlines according to BGV A2 for electrical resources must be complied with Please consider that unauthorized modifications on the device are forbidden due to safety reasons If this device will be operated in any way different to the one described in this manual the product may suffer damages and the guarantee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shock crash etc 4 DESCRIPTION 4 1 Features Practical 32A distributor in 19 housing Specially designed for larger distribution needs 3U necessary for installation 32A three phase current input via power cable and plug 32A three phase current output via mounted plug secured on the back panel by a fault current circuit breaker The entire distributor is secured via a 30mA fault current circuit breaker 2 mounted CEKON sockets with 16A on the front panel are secured via 3 x 16A fuse blocks Control lamps indicate each phase 6 safety sockets on the housing back 2 per phase Each pair of safety Sockets feature fuse protection via 16A automatic circuit breakers With earthing screw in order to ground a rigg if necessary 12 15 00026727 DOC Version 2 1 4 2 Description of the device INPUT AC380 400V 50Hz 1 32A three phase current input plug 2 32A three phase current output socket 3 Phase 1 power outlet 4 Phase 2 power outlet 5 Phase 3 power ou
15. gs und Servicearbeiten sind ausschlie lich dem autorisierten Fachhandel vorbehalten Sollten einmal Ersatzteile ben tigt werden verwenden Sie bitte nur Originalersatzteile Die Pr ffristen f r ortsver nderliche elektrische Betriebsmittel BGV A2 sind einzuhalten Der Unternehmer hat daf r zu sorgen dass die elektrischen Anlagen und Betriebsmittel vor der ersten Inbetriebnahme und nach einer Anderung oder Instandsetzung vor der Wiederinbetriebnahme durch eine Elektrofachkraft auf ihren ordnungsgem en Zustand gepr ft werden Elektrische Anlagen und Betriebsmittel d rfen nur in ordnungsgem em Zustand in Betrieb genommen werden und m ssen in diesem Zustand erhalten werden Zur Erhaltung des ordnungsgem en Zustandes sind elektrische Anlagen und Betriebsmittel wiederholt nach Art und Umfang der in den elektrotechnischen Regeln festgelegten Ma nahmen zu pr fen Die Verantwortung f r die ordnungsgem e Durchf hrung der Pr fungen obliegt einer Elektrofachkraft Ortsveranderliche elektrische Betriebsmittel Verl ngerungs und Ger teanschlussleitungen mit Steckvorrich tungen Anschlussleitungen mit Stecker und bewegliche Leitungen mit Stecker und Festanschluss m ssen alle drei Monate durch eine Elektrofachkraft auf ordnungsgem en Zustand gepr ft werden Sollten Sie noch weitere Fragen haben steht Ihnen Ihr Fachhandler jederzeit gerne zur Verf gung 7 TECHNISCHE DATEN Bitte beachten Sie Technische Anderung
16. hen werden und das Ger t mit einem trockenen Tuch gereinigt werden Staub kann die Isolation reduzieren was zu t dlichen Stromschlagen f hren kann St rkere Verschmut zungen im und am Ger t d rfen nur von einem Fachmann beseitigt werden Es d rfen unter keinen Umstanden Fl ssigkeiten aller Art in Steckdosen Steckverbindungen oder in irgendwelche Geratedffnungen oder Ger teritzen eindringen Besteht der Verdacht dass auch nur minimale Fl ssigkeit in das Gerat eingedrungen sein k nnte muss das Ger t sofort allpolig vom Netz getrennt werden Dies gilt auch wenn das Ger t hoher Luftfeuchtigkeit ausgesetzt war Auch wenn das Ger t scheinbar noch funktioniert muss es von einen Fachmann berpr ft werden ob durch den Fl ssigkeitseintritt eventuell Isolationen beeintr chtigt wurden Reduzierte Isolationen k nnen t dliche Stromschl ge hervorrufen In das Ger t d rfen keine fremden Gegenst nde gelangen Dies gilt insbesondere f r Metallteile Sollten auch nur kleinste Metallteile wie Heft und B roklammern oder gr bere Metallsp ne in das Ger t gelangen so ist das Ger t sofort au er Betrieb zu nehmen und allpolig vom Netz zu trennen Durch Metallteile hervorgerufene Fehlfunktionen und Kurzschl sse k nnen t dliche Verletzungen zur Folge haben Die Gesamtmasse der Installation Gesamtgewicht aller Einzelteile darf die zul ssige Tragf higkeit des Montageortes niemals berschreiten Kinder und Laien vom Ger t fern ha
17. i dem Rack sollte es sich um ein Double Door Rack handeln an dem sich sowohl die Vorder als auch die R ckseite ffnen lassen Das Rackgeh use sollte mit einem L fter versehen sein Achten Sie bei der Standortwahl des 19 Unterverteilung 32As darauf dass die warme Luft aus dem Rack entweichen kann und gen gend Abstand zu anderen Ger ten vorhanden ist Dauerhafte berhitzung kann zu Sch den am 19 Unterverteilung 32A f hren Sie k nnen den 19 Unterverteilung 32A mit vier Schrauben M6 im Rack befestigen Werden mehrere 19 Unterverteilung 32A bereinander montiert so ist darauf zu achten dass zwischen den Ger ten mindestens 1 H heneinheit Luft bleibt Seien Sie vorsichtig beim Einbau des 19 Unterverteilung 32As in ein Rack Bauen Sie die schwersten Ger te in den unteren Teil des Racks ein 5 2 Anschl sse 5 2 1 Anschluss ans Netz Schlie en Sie das Ger t ber den CEKON Stecker ans Netz an Wenn das Ger t direkt an das rtliche Stromnetz angeschlossen wird muss eine Trennvorrichtung mit mindestens 3 mm Kontakt ffnung an jedem Pol in die festverlegte elektrische Installation eingebaut werden 5 2 2 Ausg nge Die Ausg nge gehen ber 6 Schutzkontaktsteckdosen 2 16A Drehstrom Ausgangsdosen und 1 32A Drehstrom Ausgangsdose ber die Ausgangsbuchsen schlie en Sie Ihre Verbraucher an Die maximale Nennleistung betr gt pro Kanal 3680 W bzw 11040 W und 22080 W Bitte beachten Sie dass der maximale Gesamtstrom niem
18. lten Das Ger t darf niemals unbeaufsichtigt betrieben werden 4 15 00026727 DOC Version 2 1 3 BESTIMMUNGSGEMARE VERWENDUNG Bei diesem Gerat handelt es sich um eine 19 Unterverteilung 32A mit dem sich andere Ger te versorgen lassen Dieses Produkt ist nur f r den Anschluss an 380 400 V 50 Hz Wechselspannung zugelassen und wurde ausschlie lich zur Verwendung in Innenr umen konzipiert Dieses Ger t ist sowohl f r den Mobilbetrieb als auch f r Festinstallationen vorgesehen Dieses Ger t ist f r professionelle Anwendungen z B auf B hnen in Diskotheken Theatern etc vorgesehen Die maximale elektrische Gesamtleistung darf niemals berschritten werden Achten Sie bei der Wahl des Installationsortes darauf dass das Ger t nicht zu gro er Hitze Feuchtigkeit und Staub ausgesetzt wird Vergewissern Sie sich dass keine Kabel frei herumliegen Sie gefahrden Ihre eigene und die Sicherheit Dritter Das Ger t darf nicht in einer Umgebung eingesetzt oder gelagert werden in der mit Spritzwasser Regen Feuchtigkeit oder Nebel zu rechnen ist Feuchtigkeit oder sehr hohe Luftfeuchtigkeit kann die Isolation reduzieren und zu t dlichen Stromschl gen f hren Beim Einsatz von Nebelger ten ist zu beachten dass das Ger t nie direkt dem Nebelstrahl ausgesetzt ist und mindestens 0 5 m von einem Nebelger t entfernt betrieben wird Die Umgebungstemperatur muss zwischen 5 C und 45 C liegen Halten Sie das Ger t von direkte
19. m ssen entsprechend qualifiziert sein diese Bedienungsanleitung genau beachten die Bedienungsanleitung als Teil des Produkts betrachten die Bedienungsanleitung w hrend der Lebensdauer des Produkts behalten die Bedienungsanleitung an jeden nachfolgenden Besitzer oder Benutzer des Produkts weitergeben Sich die letzte Version der Anleitung im Internet herunter laden 1 EINF HRUNG Wir freuen uns dass Sie sich f r eine EUROLITE SB 1100 19 Unterverteilung 32A entschieden haben Wenn Sie nachfolgende Hinweise beachten sind wir sicher dass Sie lange Zeit Freude an Ihrem Kauf haben werden Nehmen Sie die SB 1100 aus der Verpackung Bitte berpr fen Sie vor der ersten Inbetriebnahme ob Transportschaden vorliegen In diesem Fall nehmen Sie das Ger t nicht in Betrieb und setzen sich bitte mit Ihrem Fachh ndler in Verbindung 2 SICHERHEITSHINWEISE ACHTUNG Seien Sie besonders vorsichtig beim Umgang mit gefahrlicher Netzspannung Bei die ser Spannung k nnen Sie einen lebensgef hrlichen elektrischen Schlag erhalten Dieses Gerat hat das Werk in sicherheitstechnisch einwandfreiem Zustand verlassen Um diesen Zustand zu erhalten und einen gefahrlosen Betrieb sicherzustellen muss der Anwender die Sicherheitshinweise und die Warnvermerke unbedingt beachten die in dieser Bedienungsanleitung enthalten sind LS Unbedingt lesen Bei Sch den die durch Nichtbeachtung der Anleitung verursacht werden erlischt der Garantie
20. n the frontpanel and the rear panel The rack should be provided with a cooling fan When mounting the 19 distributor into the rack please make sure that there is enough space around the device so that the heated air can be passed on Steady overheating will damage your device You can fix the 19 distributor with four M6 screws in the rack Be careful when mounting the 19 distributor into the rack Put the heaviest devices into the lower part of the rack 5 2 Connections 5 2 1 Connection with the mains Connect the device to the mains with the CEKON plug The earth has to be connected If the device will be directly connected with the local power supply network a disconnection switch with a minimum opening of 3 mm at every pole has to be included in the permanent electrical installation 5 2 2 Outputs Output is via 6 safety sockets 2 16A three phase current output sockets and 1 32A three phase current output socket Connect your loads via the output sockets The maximum load per channel is 3 680 W resistive 11040 W and 22080 W respectively Please note that the maximum current must never be exceeded DANGER TO LIFE Before taking into operation for the first time the installation has to be approved by an expert 6 CLEANING AND MAINTENANCE The operator has to make sure that safety relating and machine technical installations are inspected by an expert after every four years in the course of an acceptance test The
21. operator has to make sure that safety relating and machine technical installations are inspected by a skilled person once a year The following points have to be considered during the inspection 14 15 00026727 DOC Version 2 1 1 All screws used for installing the devices or parts of the device have to be tighly connected and must not be corroded 2 The electric power supply cables must not show any damages material fatigue e g porous cables or sediments Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed DANGER TO LIFE Disconnect from mains before starting maintenance operation We recommend a frequent cleaning of the device Please use a moist lint free cloth Never use alcohol or solvents There are no serviceable parts inside the device Maintenance and service operations are only to be carried out by authorized dealers Should you need any spare parts please use genuine parts The examination intervals for mobile electrical devices German BGV A2 must be kept The operator has to make sure that the electrical devices are examined by an electrician before taking into operation for the first time and after changes before taking into operation another time Electrical devices must only be taken into operation in a perfect condition and must be kept this way For keeping the perfect condition electrical devices must repe
22. r Sonneneinstrahlung auch beim Transport in geschlossenen Wagen und Heizk rpern fern Die relative Luftfeuchte darf 50 bei einer Umgebungstemperatur von 45 C nicht berschreiten Dieses Ger t darf nur in einer H henlage zwischen 20 und 2000 m ber NN betrieben werden Der Umgebungsverschmutzungsgrad darf 1 nicht berschreiten keine oder nur trockene nichtleitende Verschmutzung Verwenden Sie das Ger t nicht bei Gewitter berspannung k nnte das Ger t zerst ren Das Ger t bei Gewitter allpolig vom Netz trennen Netzstecker ziehen Achten Sie bei der Montage beim Abbau und bei der Durchf hrung von Servicearbeiten darauf dass der Bereich unterhalb des Montageortes abgesperrt ist Nehmen Sie das Ger t erst in Betrieb nachdem Sie sich mit seinen Funktionen vertraut gemacht haben Lassen Sie das Gerat nicht von Personen bedienen die sich nicht mit dem Gerat auskennen Wenn Ger te nicht mehr korrekt funktionieren ist das meist das Ergebnis von unsachgem er Bedienung Reinigen Sie das Gerat niemals mit L sungsmitteln oder scharfen Reinigungsmitteln sondern verwenden Sie ein weiches und angefeuchtetes Tuch Soll das Ger t transportiert werden verwenden Sie bitte die Originalverpackung um Transportschaden zu vermeiden Die Pr fungsfristen gem BGV A2 f r elektrische Betriebsmittel m ssen eingehalten werden Beachten Sie bitte dass eigenmachtige Ver nderungen an dem Ger t aus Sicherheitsgr nden verboten
23. tlet 6 19 housing eurolite 9 SB 1100 BREAKER 32A 30mA 3 P FUSE C16A 3 P FUSE C16A 3 FUSES C16A 16A OUTPUT 1 16A OUTPUT2 Eur 7 2x 16A three phase current output socket 8 Circuit breaker for power distribution sockets back side 9 3x 16A circuit breaker for three phase current front side 10 Fault current circuit breaker 11 Control lamps 13 15 00026727 DOC Version 2 1 5 INSTALLATION DANGER TO LIFE Please consider the DIN 15560 and the respective national norms during the installation The installation must only be carried out by an authorized dealer The operator has to make sure that safety relating and machine technical installations are approved by an expert before taking into operation for the first time and after changes before taking into operation another time The operator has to make sure that safety relating and machine technical installations are approved by an expert after every four year in the course of an acceptance test The operator has to make sure that safety relating and machine technical installations are approved by a skilled person once a year Procedure The installation should be attached outside areas where persons may walk by or be seated 5 1 Rack installation This 19 distributor 32A is built for 19 racks steel cabinets 483 mm The rack you use should be a double door rack where you can ope
Download Pdf Manuals
Related Search
Related Contents
SERVICE MANUAL 4547 - Ansaldo STS WLAN Dual SerialBridge™ RR-XS410 RR-XS400 - Panasonic Canada Samsung S23A750D Uživatelská přiručka Sharp XE-A40S Quick Guide Sistemi e soluzioni per nuotare in sicurezza con ProMinent 82-0074-000--Manual, User`s, VT1415A--Rev. 08 Campus Recreation Services Maryland Sport Clubs GoPro Video Copyright © All rights reserved.
Failed to retrieve file