1. 322 mm 12 677 330 mm 12 992 Figure 2 22 TP120AT A Mounting Cutout B Front Panel 28 Installation and Commissioning S Line Touch Panel TP151AT 2 2 2 11 EN IER EUM 688 11 206 656721 626 373 14 685 400 mm 15 748 Figure 2 23 TP151AT A Mounting Cutout B Front Panel 29 SUTRON 6 Installation and Commissioning S Line Touch Panel 2 2 3 Side View Mounting Depth 2 2 3 1 TP11AM TP11AT 45 mm 1 772 1 299 Figure 2 24 11 TP11AT Mounting Bracket Threaded Pin Mounting Surface Thickness 1 mm to 6 mm Circumferential Seal Front Panel Qo WON 30 S Line Touch Panel Installation and Commissioning 2 2 3 2 TP21AM TP21AS TP21AT 66 mm 2 598 54 mm 2 126 Figure 2 25 TP21AM TP21AS TP21AT Mounting Bracket Threaded Pin Mounting Surface Thickness 1 mm to 6 mm Circumferential Seal Front Panel Qo ON SUTRON Installation and Commissioning S Line Touch Panel 2 2 3 3 TP35AM TP35AT 47 mm 1 85 35 mm 1 378 Figure 2 26 TP35AM TP35AT Mounting Bracket Threaded Pin Mounting Surface Thickness 1 mm to 6 mm Circumferential Seal Front Panel coc WON 32 S Line Touch Panel Installa
2. 70 V Ethernet ssss e 60 Version 56 INTERBUS ndr te des 72 78 MPI SAV icit i retain hae 74 PROFIBUS DP Slave 76 RS422 RS485 5232 62 5 Safety notes 2 7 SEMIN 81 Setup Main operating mode 45 Side view 2 0 2 0002 35 2255 ts 36 104 2 05 90 37 TBPTO5AT ecc edere estes 38 TP11AM 1 222222 2 4 30 TPA2O0AT uim eti iret 39 TPA5TAT tee 40 TP21AM TP21AS TP21AT 31 TP35AM 32 TPA A Tenn ich 33 TP57AM 57 34 Standards iie ie re OR Reed ee ber a 84 Supply 41 Switching Of iine ree reges 43 T Target 8 Technical data irent 83 TPOTOATNM uai rara rra Fan rider te nda 96 iit ates tidie ain 97 TPAOAMAT iieri anre nere 99 TRIOSSA Teria 100 TPTIAM 5i ii ceti nre 86 R 87 TP420AT iet ipn 101 TBP15941AT iiseei dere eerte te 102 TP2TAM
3. Pin Designation Function 6 TD Transmitted Data 15 CTS Clear to Send 17 RTS Request to Send 18 RD Received Data 25 SGND Signal Ground NOTICE For the operation of the interface as RS232 the pins of the RS422 RS485 must not be connected NOTICE The D SUB connector strips must be shielded sufficiently See chapter Shield ing D SUB Connectors on page 4 79 4 2 2 2 Termination NOTICE When the interface is operated as a RS232 the termination for the RS485 must be switched OFF 65 SUTRON Interfaces of the Device S Line Touch Panel 4 3 Field Bus Interfaces 4 3 1 CAN Slave X6 The CAN bus is a high speed bus in accordance with ISO DIS 11898 3 4 5 6 Figure 4 7 Rear view CAN Slave Female Connector X5 Ethernet Connector X6 CAN Female Connectors X9 X10 USB Host Type A Threaded Bolt for Protective Grounding Slope Control Switch CAN Connector X1 Supply Voltage 66 S Line Touch Panel Interfaces of the Device 4 3 1 1 Pin Assignment 1 5 6 9 Figure 4 8 9 pin D SUB male connector strip Connector in the terminal 9 pin D SUB male connector Table 4 8 Pin assignment CAN Pin Designation Function 1 nc Not Connected 2 CAN L CAN L Bus Line 3 CAN GND CAN Ground 4 nc Not Connected 5 nc Not Connected 6 CAN GND CAN Ground 7
4. 2 11 m 11 12 81 Identification 42 44 56 Intended use i i trit 8 Interface CAN SIAVC ea eodd 66 DeviceNet 70 Ethernet c 60 INTERBUS 2 222 2 72 a CH eae 78 MP 74 PROFIBUS slave 76 tee ci ipe x dde 65 R9422 i s ax a 63 aNLEILM M 63 61 L Launch structure 44 Loading procedure on windows CE operating sys 43 81 MOUMUIAG 22 2222 Leti peo eee 9 Mounting Cutout TPOTORBTW icc tete 24 90 2 25 TP IOTA Tani eI 26 27 TP11AM 19 TP A20AT 28 TP 154 22 iiie etant dai 29 TP21AM TP21AS TP21AT 20 TP35AM 21 HcqE 22 TPSTAM 23 Mounting depth TPOTOATMW s inier rame
5. 56 43 Controland Display 5 2 tue eta 57 3 1 BEE E 57 3 1 1 Touch Screen ssssssssssssssss esee nnne nnne 57 4 Interfaces of the Device 59 4 1 Standard 60 4 1 1 Ethernet ect Bede pce ita beet e cha oe 60 4 1 1 1 Pity Assignment retibus reed dE ette cte tides Perder ide 60 4 1 1 2 o S 60 4 1 1 3 Diagnostics C 61 4 1 2 USB X9 10 61 4 1 2 1 61 42 Serial Interfaces Ue da aaa 62 4 2 1 RS422 RS485 6 0200 63 4 2 1 1 Pin Assigrimetit c ocio rhe sp EE ree era RR DR 63 4 2 1 2 64 4 2 2 RS232 X6 cs e 65 4 2 2 1 Pin Assignimerit oiu uin eie Lane edid seco tig et dive 65 4 2 2 2 U uiisM M 65 43 Field Bus Interfaces eene ana e teen ce ase ten 66 4 3 1 CAN Slave XG MT 66 4 3 1 1 Ped anni eR 67 4 3 1 2 CAD
6. WN 62 S Line Touch Panel Interfaces of the Device 4 2 1 RS422 RS485 X6 The interface standard RS422 RS485 is suitable for point to point and multi point connections The wires belonging together are marked with A and B Some descriptions re fer to the pins with and where and B Signal Logic 1 UA Up lt 0 3 V i e UA lt Up Signal Logic 0 gt 0 3V i e UA gt Up 4 2 1 1 Pin Assignment 13 1 25 14 Figure 4 4 25 pin D SUB female connector strip Connector in the operating terminal 25 pin D SUB female connector Table 4 4 Pin assignment RS422 RS485 Pin Designation Function 8 T A Transmitted Data 9 T B Transmitted Data 11 SGND Signal Ground 22 R A Received Data 8 23 R B Received Data NOTICE For the operation of the interface as RS422 RS485 the pins of the RS232 must not be connected NOTICE The D SUB connector strips must be shielded sufficiently See chapter Shield ing D SUB Connectors on page 4 79 63 SUTRON Interfaces of the Device S Line Touch Panel 4 2 1 2 Termination Always turn on the termination in a 4 wire point to point connection RS422 RS485 A sender termination for the quiescent level of the receiver must exist on the remote station Turn on the terminatio
7. tc o 120 4 724 Figure 2 4 TP35AM TP35AT 2 2 1 4 F o SUTRON 140 mm 5 511 Figure 2 5 TP43AT SUTRON 11 Installation and Commissioning S Line Touch Panel 2 2 1 5 TP57AM TP57AT 126 0 mm 4 961 SUTRON 168 0 mm 6 614 Figure 2 6 TP57AM TP57AT 12 S Line Touch Panel Installation and Commissioning 2 2 1 6 TPO70ATW 147 0 mm 5 787 203 0 mm 7 992 Figure 2 7 TPO7OATW 13 SUTRON Installation and Commissioning S Line Touch Panel 2 2 1 7 TPOSOATW 172 mm 6 772 260 mm 10 236 Figure 2 8 TPO90ATW 14 S Line Touch Panel Installation and Commissioning 249 0 mm 9 803 2 2 1 8 TP104AT 328 0 mm 12 913 Figure 2 9 TP104AT S SUTRON 15 Installation and Commissioning S Line Touch Panel 2 2 1 9 TP105AT 2 oe 2 ui 295 mm 11 614 Figure 2 10 TP105AT 16 S Line Touch Panel Installation and Commissioning 2 2 1 10 TP120AT DS 225 mm 8 858 330 mm 992 Figure 2 11 120 S SUTRON 17 Installation and Commissioning S Line Touch Panel 2 2 1 11 TP151AT 329 mm 12 953 400 mm 15 748 Figure 2 12 TP151AT 18 S Line Touch Panel Installation and Commissioning 2 2 2 Mounting Cutout 2 2 2 1 TP11AM TP11AT SUT
8. 7 1 37 Intended Use etae ed a deos id 8 1 4 Target 8 2 Installation and Commissioning 9 2 1 Unpacking the 9 2 2 Mounting the cna Pa eee E pe i ore ers 9 2 2 1 Front Panel Dimensions emen 10 2 24 1 11 11 22 2 020020 0000 600000 60 00 00090240 5808 tette 10 2 2 1 2 TP21AM TP21AS TP21AT 10 2 2 1 3 TP35AM 5 ttti tenete tte nenas 11 2 2 1 4 II 11 2 2 1 5 TP57AM 5 2 12 4 2 044000001040040000000090040050058580540405 0 03 12 2 2 1 6 TPO7OATW M 13 2 24 7 TPOSQATW creep epe tent ate etes 14 2 2 1 8 PM 15 2 2 1 9 16 2 2 1 10 120 M 17 2 2 1 11 MILI 18 2 2 2 Mounting 19 2 2 2 1 TEAM TPAMAT em lec mL LLLI 19 22 22 TP21AM TP21AS 21 2 41 4 6 000000000 000 00 005099 20 2 2 2 3 TP35AM TP35AT 2 2 2 4 2 2 2 5 TP57AM TP57AT 2 2 2 6 Mis 2 22
9. Mounting cutout H x W in mm Inch 139 x 195 5 7472 x 7 677 Mounting depth in mm Inch About 54 2 126 Standard Field Bus Interface About 66 2 598 Degree of protection Front 65 Rear 20 Total weight About 1000 g 89 S SUTRON Technical Data S Line Touch Panel 6 6 TP21AT Display Type TFT color Resolution pixels 320 x 240 Colors 65536 Reading angle vertical 105 130 horizontal Half life backlighting 50 000 h Brightness in cd m 400 Display area H x W in mm Inch 86 4 x 115 2 3 402 x 4 535 Electrical Data Supply voltage 24 V DC SELV PELV in accordance with DIN EN 61131 Residual ripple 10 96 maximum Minimum voltage 18V Maximum voltage 30V Power consumption typi 0 4 A cal at 24 V Power consumption max 0 6 imum Connected load 9 6 W Fuse Semiconductor fuse self resetting Protection against polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed anodized natural finish Front panel H x W x D in mm Inch 147 x 203 x 5 5 787 x 7 992 x 0 197 Seal Circumferential rubber seal on the rear Mounting cutout H x W in mm Inch 139 x 195 5 7472 x 7 677 Mounting depth in mm Inch About 54 2 126 Standard
10. Enter User MyName Enter Password Confirm Password Cancel Figure 2 53 Add new user You may enter a new user name You have to assign a password to the user name and to confirm it If at least one user name is added you cannot login to the FTP server as anony mous anymore Network Settings FTP Settings List all users All users are listed within a DOS box Network Settings FTP Settings Delete a user Delete a user Enter User Enter Password 1 Confirm Password 9c 11 Figure 2 54 Delete a user You may enter the user name you like to delete This entry is able to be password protected 50 S Line Touch Panel Installation and Commissioning Network Settings Device Name Device name Enter Device Name MyDeviceName OK Cancel Figure 2 55 Device Name You can define a device name with up to 14 characters Via a FTP connection you can access the device with the device name instead of the IP address This entry is able to be password protected Settings Date Time Figure 2 56 Settings Settings Contrast Contrast Contrast Brightness 15 15 H Color Depth 8bpp 16 bpp Figure 2 57 Contrast The operating mode setup main is displayed with default values for contrast and brightness to ensure reading also at faulty values If you change a value you have to confirm this in a dia
11. Mounting cutout H x W in mm Inch 217 x 322 8 543 x 12 677 Mounting depth in mm Inch About 54 2 126 Standard Field Bus Interface About 66 2 598 Degree of protection Front IP65 Rear IP20 Total weight About 1900 g S SUTRON 101 Technical Data S Line Touch Panel 6 17 TP151AT Display Type TFT color Resolution pixels 1024 x 768 Colors 256 Reading angle vertical 135 160 horizontal Backlight CCFL Half life backlighting 50 000 h Brightness in cd m 480 Display area H x W in 228 x 304 mm Inch 8 976 x 11 969 Electrical Data Supply voltage 24 V DC SELV PELV in accordance with DIN EN 61131 Residual ripple 10 96 maximum Minimum voltage 18V Maximum voltage 30 V Power consumption typi 1 0A cal at 24 V Power consumption max 1 2A imum Connected load 24 W Fuse Semiconductor fuse self resetting Protection against polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed anodized natural finish Front panel H x W x D in mm Inch 329 x 400 x 5 12 953 x 15 748 x 0 197 Seal Circumferential rubber seal on the rear Mounting cutout H x W in mm Inch 303 x 374 11 929 x 14 724 Mounting depth in mm Inch About 60 2 362 Standard
12. 68 4 3 1 3 Dump 68 4 3 1 4 DiaQnOStiCS m 69 4 3 1 5 SSIS GOON C EI 69 4 3 2 DeviceNet Slave 6 nnns 70 4 3 2 1 Pin Assignment sssssssssssssssssseee eene nennen se tenti sehen sentent inet rsen nre 70 4 3 2 2 Cable m 71 4 3 2 3 Iuuen m 71 4 3 2 4 DiaQNnOSUCS NE 71 4 3 3 INTERBUS Slave X6 7 72 4 3 3 1 erai 72 4 3 3 2 73 4 3 3 3 Te 73 4 3 4 74 4 3 4 1 74 4 3 4 2 75 SUTRON S Line Touch Panel Overall Table of Contents 5 6 7 4 3 4 3 TS ulcus 75 4 3 4 4 BI eei P 75 4 3 5 PROFIBUS DP Slave 6 eee 76 4 3 5 1 76 4 3 5 2 CABG 77 4 3 5 3 77 4 3 5
13. Enclosure Steel sheet galvanized Front panel material Aluminium brushed anodized natural finish Front panel H x W x D in mm Inch 96 x 130x 5 3 78 x 5 118 x 0 197 Seal Circumferential rubber seal on the rear Mounting cutout H x W in mm Inch 88 x 122 3 465 x 4 803 Mounting depth in mm Inch About 33 1 299 Standard Field Bus Interface About 45 1 772 Degree of protection Front IP65 Rear 20 Total weight About 500 g SUTRON 87 Technical Data S Line Touch Panel 6 4 TP21AM Display Type FSTN mono Resolution pixels 320 x 240 Colors 5 Shades of gray Reading angle vertical 90 80 horizontal Contrast setting Temperature compensated Half life backlighting 40 000 h Brightness in cd m 120 Display area H x W in 86 4 x 115 2 3 402 x 4 535 mm Inch Electrical Data polarity reversal Supply voltage 24 V DC SELV PELV in accordance with DIN EN 61131 Residual ripple 10 96 maximum Minimum voltage 18V Maximum voltage 30 V Power consumption typi 0 25 A cal at 24 V Power consumption max 0 35 A imum Connected load 6 W Fuse Semiconductor fuse self resetting Protection against Integrated Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed an
14. Field Bus Interface About 72 2 835 Degree of protection Front IP65 Rear IP20 Total weight About 2300 g 102 S Line Touch Panel Ordering Data 7 Ordering Data Table 7 1 Accessories Description Part No USB 2 0 stick 1 GB 81152 100 Battery assembled with cable and connector Type CR2450 66779 000 Protective foil for touch screen 3 5 Set with 10 protective foils scraper and instructions 81251 035 Protective foil for touch screen 3 8 Set with 10 protective foils scraper and instructions 81251 038 Protective foil for touch screen 5 7 Set with 10 protective foils scraper and instructions 81251 057 Protective foil for touch screen 7 Set with 10 protective foils scraper and instructions 81251 070 Protective foil for touch screen 9 Set with 10 protective foils scraper and instructions 81251 090 Protective foil for touch screen 10 4 Set with 10 protective foils scraper and instructions 81251 104 Protective foil for touch screen 12 Set with 10 protective foils scraper and instructions 81251 120 Protective foil for touch screen 15 Set with 10 protective foils scraper and instructions 81251 150 DeviceNet connector with cover cap 57353 005 57357 005 PROFIBUS DP connector for bus end straight cable outlet 57330 000 PROFIBUS DP connector angular cable outlet with screw connection 57234 000 PROFIBUS DP connector angular cable outlet with spring
15. Installation and Commissioning S Line Touch Panel 2 3 2 Grounding The grounding is performed depending on the type of device with a slip on sleeve noiseless ground functional earth ground or a ring cable lug protective ground NOTICE Damage A separate copper conductor must always be provided for the grounding The conductor must have a minimum cross section of 1 5 mm 16 AWG and must be kept as short as possible You must adhere to a maximum torque of 1 Nm at an protective grounding on the threaded bolt Strip approx 5 mm 0 197 off the wires 2 Fit the stripped wires depending on the type of device with a slip on sleeve or a ring cable lug 3 Plug the slip on sleeve on the flat tab or mount the ring cable lug with the nut to the threaded bolt Figure 2 36 Noiseless ground protective ground 42 S Line Touch Panel Installation and Commissioning 2 4 Switching On The Windows CE operating system is installed on the operating device Running on the operating system is the visualization runtime 2 4 1 Loading Procedure on Windows CE Operating Sys tem The program allows you to use the buttons to make changes to the configuration The operating device has 3 operating modes Normal no button is pressed Setup Main Button Press For Setup Main Menu was pressed Administration Admin button was pressed 43 SUTRON Installation and Commiss
16. Technical Data S Line Touch Panel 6 8 TP35AT Display Type TFT color Resolution pixels 320 x 240 Colors 65536 Reading angle vertical 150 130 horizontal Backlight LED Half life backlighting 40 000 h Brightness in cd m 350 Display area H x W in 52 5 x 70 2 066 x 2 755 mm Inch Electrical Data Supply voltage 24 V DC SELV PELV in accordance with DIN EN 61131 Residual ripple 10 96 maximum Minimum voltage 18V Maximum voltage 30 V Power consumption typi 0 3A cal at 24 V Power consumption max 0 4 A imum Connected load 7 2W Fuse Semiconductor fuse self resetting Protection against polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed anodized natural finish Front panel H x W x D in mm Inch 90 x 120 x 5 3 543 x 4 724 x 0 197 Seal Circumferential rubber seal on the rear Mounting cutout H x W in mm Inch 82 x 112 3 228 x 4 409 Mounting depth in mm Inch About 35 1 377 Standard Field Bus Interface About 47 1 85 Degree of protection Front IP65 Rear IP20 Total weight About 430 g 92 S Line Touch Panel Technical Data 6 9 TPASAT Display Type TFT color Resolution pixels 480 x 272 Colors 65536 Reading angle
17. 35 90 2 2222 36 37 105 38 TP11TAM 30 120 39 TPRI 40 TP21AM 21 5 2 31 TP35AM 32 ED 33 34 56 Normal 1 2 45 O Ordering 103 Pin assignment CAN 67 DeviceNet 44 40 70 Ethernet 60 INTERBUS 72 NX 78 SUTRON 74 75 PROFIBUS tetris 76 PROFIBUS icai esee ei e id tae 77 5292 65 5232 0 65 5422 esie 63 RS485 iicet eerta a ed 64 I35485 ated 63 TOUCH SCIeOn i dier p d exerted 57 R U Rear view Unpacking ced rtu 9 CAN Slave 66 DeviceNet slave
18. 5 5 Power Supply 5 VDC 6 DO Data Output Inverted 7 DI Data Input Inverted 8 nc Not Connected 9 RBST Remote Bus Status NOTICE The D SUB connector strips must be shielded sufficiently See chapter Shield ing D SUB Connectors on page 4 79 4 3 3 2 Cable NOTICE A shielded twisted pair cable cable type LiYCY TP must be used The maxi mum cable length depends on its use within the INTERBUS topology 4 3 3 3 The diagnostics LEDs are located at the rear of the operating device The LEDs show the states of the bus system Diagnostics The diagnostics LEDs at the operating device has the following functions Table 4 20 Functions of the INTERBUS diagnostics LEDs Designation Color State Function RC Green On Remote Bus Check 5 Green On Supply Voltage OK Off No Supply Voltage BA Green On Bus Active Off Bus Not Active RD Red On Remote Bus Inactive TR Green On PCP Active Module Receives Trans mitts Data Off PCP not Active 6 SUTRON 73 Interfaces of the Device S Line Touch Panel 4 3 4 MPI Slave X6 Figure 4 13 Rear view slave Female Connector X5 Ethernet Female Connector X6 Female Connectors X9 X10 USB Host Type A Threaded Bolt for Protective Grounding Connector X1 Supply Voltage 4 3 4 1 Pin Assignment 5 1 OOOOO 9 6 Figure 4 14 9 pin D SUB
19. Fuse Semiconductor fuse self resetting Protection against polarity reversal Integrated S SUTRON 97 Technical Data S Line Touch Panel Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed anodized natural finish Front panel H x W x D in mm Inch 172x260x5 6 772 x 10 236 x 0 197 Seal Circumferential rubber seal on the rear Mounting cutout H x W in mm Inch 164 x 252 6 456 x 9 921 Mounting depth in mm Inch About 54 2 126 Standard Field Bus Interface About 66 2 598 Degree of protection Front IP65 Rear IP20 Total weight About 1300 g 98 S Line Touch Panel Technical Data 6 14 TP104AT Display Type TFT color Resolution pixels 640 x 480 Colors 65536 Reading angle vertical 110 140 horizontal Half life backlighting 50 000 h Brightness in cd m 350 Display area H x W in 158 x 211 mm Inch 6 22 x 8 307 Electrical Data Supply voltage 24 V DC SELV PELV in accordance with DIN EN 61131 Residual ripple 10 96 maximum Minimum voltage 18V Maximum voltage 30 V Power consumption typi 0 6A cal at 24 V Power consumption max 0 8A imum Connected load 14 4 W Fuse Semiconductor fuse self resetting Protection against polarity reversal I
20. Minimum voltage 18V Maximum voltage 30V Power consumption typi 0 4 cal at 24 V Power consumption max 0 6 imum Connected load 9 6 W Fuse Semiconductor fuse self resetting Protection against Integrated polarity reversal Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed anodized natural finish Front panel H x W x D mm Inch 126 x 168 x 5 4 961 x 6 614 x 0 197 Seal Circumferential rubber seal on the rear Mounting cutout H x W in mm Inch 118 x 160 4 646 x 6 299 Mounting depth in mm Inch About 42 1 654 Standard Field Bus Interface About 54 2 126 Degree of protection Front IP65 Rear 20 Total weight About 690 g SUTRON 95 Technical Data S Line Touch Panel 6 12 TPO70ATW Display Size diagonal in cm 17 78 7 inch Type TFT color Resolution pixels 800 x 480 Colors 65536 Reading angle vertical 130 140 horizontal Backlight LED Half life backlighting 40 000 h Brightness in cd m 350 Display area H x W in 91 4 x 152 4 mm Inch 3 598 x 6 0 Electrical Data Supply voltage 24 V DC SELV PELV in accordance with DIN EN 61131 Residual ripple 10 96 maximum Minimum voltage 18V Maximum voltage 30V Power consumption typi 0 5 A cal at 24 V Power c
21. S Line Touch Panel 43 6 X6 Figure 4 17 Rear view KNX Female Connector X5 Ethernet Female Connectors X9 X10 USB Host Type A Threaded Bolt for Protective Grounding Male Connector X6 KNX Connector X1 Supply Voltage a WON 4 3 6 1 Pin Assignment 1 Figure 4 18 2 pin male connector strip Connector in the operating device 2 pin male connector strip Table 4 28 Pin assignment KNX Pin Designation Function 1 Ground 2 Supply Voltage Communication 78 S Line Touch Panel Interfaces of the Device 4 4 Shielding D SUB Connectors You must shield D SUB connectors as follows L u 1 2 3 4 Figure 4 19 Shielding D SUB connectors D SUB connector Shield Cable clip Cable The shield must be folded back into a flat position over the cable sheath When fastening the cable with the cable clip as much of the shielding as possible must be in contact with the housing and sufficient strain relieve must be ensured 79 SUTRON Interfaces of the Device S Line Touch Panel 80 S Line Touch Panel Maintenance and Servicing 5 Maintenance and Servicing 5 1 Front Panel Only use a damp cloth to remove any dirt from the front panel 5 2 Fuse 1 NOTICE Damage The semiconductor fuse cannot be replaced A semiconductor fuse is used to pro
22. aiite ett rrr reti teer pet 88 2 E 89 90 91 92 TPASAT 93 94 TPI 95 Termination M EIL 68 DeviceNet 71 106 SUTRON SUTRON
23. vertical 120 150 horizontal Half life backlighting 40 000 h Brightness in cd m 450 Display area H x W in 53 8 x 95 mm Inch 2 118 x 3 74 Electrical Data Supply voltage 24 V DC SELV PELV in accordance with DIN EN 61131 Residual ripple 10 maximum Minimum voltage 18V Maximum voltage 30 V Power consumption typi 0 3A cal at 24 V Power consumption max 0 4 A imum Connected load 7 2 W Fuse Semiconductor fuse self resetting Protection against polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed anodized natural finish Front panel H x W x D mm Inch 100 x 140 x 5 3 937 x 5 511 x 0 197 Seal Circumferential rubber seal on the rear Mounting cutout H x W in mm Inch 92 x 132 3 622 x 5 196 Einbautiefe About 42 1 654 Standard Field Bus Interface About 54 2 126 Degree of protection Front IP65 Rear 20 Total weight About 590 g SUTRON 93 Technical Data S Line Touch Panel 6 10 TP57AM Display Type TFT mono Resolution pixels 320 x 240 Colors 256 Shades of gray Reading angle vertical 135 150 horizontal Half life backlighting 40 000 h Brightness in cd m 250 Display area H x W in mm Inch 86 4 x 115 2 3 402
24. 164 mm 6 457 2 2 2 7 TP090ATW 252 mm 9 921 260 mm 10 236 Figure 2 19 TPO90ATW A Mounting Cutout B Front Panel SUTRON 25 S Line Touch Panel Installation and Commissioning TP104AT 2 2 2 8 0 9 0222 08 6 0 6 c N D e E E oo e N e e u 5 Figure 2 20 TP104AT A Mounting Cutout B Front Panel 26 S Line Touch Panel Installation and Commissioning 2 2 2 9 TP105AT ee cin im S tm Cem pe ru eem io ihm D noma mm est i mt dam dn a 220 8 661 212 8 346 I I I I I I I I I I I I p 287 mm 11 299 1i 295 mm 11 614 Figure 2 21 TP105AT A Mounting Cutout B Front Panel 27 SUTRON Installation and Commissioning S Line Touch Panel 2 2 2 10 TP120AT olol wo 1 9 OQ 2 i E Ej i N Y og e E a a an a
25. 328 084 feet B See the IEEE 802 3 standard for further information 60 S Line Touch Panel Interfaces of the Device 4 1 1 3 Diagnostics Ethernet diagnostics LEDs are located at the operating device 1 2 Figure 4 2 Position of the ethernet diagnostics LEDs Table 4 3 Function of the ethernet diagnostics LEDs No Color State Designation Function 1 Green ON XMT Sending ethernet data telegram 2 Yellow ON RCV Receiving ethernet data telegram 4 1 2 USB X9 X10 Two host interfaces are available on the operating device NOTICE Using input devices not suitable for industrial use e g keyboard mouse may decrease safety of operation This includes input devices intended for home and office use 4 1 2 1 Cable For the specification of a suitable cable please refer to the Universal Serial Bus Specification Rev 2 0 NOTICE The maximum cable length for the cable used is 2 5 m 8 202 feet 61 SUTRON Interfaces of the Device S Line Touch Panel 4 2 Serial Interfaces Figure 4 3 Rear view RS422 5485 RS232 Female Connector X5 Ethernet Female Connector X6 Serial Interface Female Connectors X9 X10 USB Host Type A Threaded Bolt for Protective Grounding Termination Switch RS422 RS485 Connector X1 Supply Voltage
26. 4 DIAQGMOSUCS eec 77 4 3 6 NG OA S 78 4 3 6 1 Pin ASSIQNMONIE 78 44 Shielding D SUB 79 Maintenance ServielfI ecce obe tope das comet 81 5 1 EP 81 DA SUI TT 81 2c A 81 5 3 1 Changing the Battery c e i RR 82 5 3 2 Battery Disposal enter xtd beau ne D qe eed 82 Technical 83 6 1 oti 83 6 22 c bei dc e a 86 6 3 D ie 87 6 4 2 HI 88 6 5 TP24AS usi teer lob ee 89 6 6 TP2TAT aint ddnde dle edite gute Eo EE 90 WE CDS and 91 6 8 5 92 6 9 JTPASAT in eden ed ad eee nite e Fed Po 93 6 10 94 6 11 TP5OZAT a rut RO ARTE E eR 95 6 12 TPOYOATW re et b Ea iiio nudes cen
27. 7 90 T 25 2 2 2 8 TP104AT 2 22 9 TP105AT 2 2 2 10 TP120AT 2 2 2 11 TP151AT 2 2 3 Side View Mounting Depth 30 2 2 3 1 TPA11AM TPATAT site cente ene t metere etre tdi 30 22 3 2 TP21AM TP21AS TP21AT 31 2 2 3 3 tens cigare eta unte db ree oe 32 2 2 3 4 NC E 33 2 2 3 5 TESTAN TRVAT Succ Dec 34 2 2 3 6 EM LI 35 2 2 3 7 Itu 36 2 2 3 8 TPAOGAT ERR 37 2 2 3 9 M pU CE IM 38 2 2 3 10 TPA2DAT 39 2 2 3 11 40 2 3 Connecting the A 41 2 3 1 Supply Voltage sssssssseeeeeeeneeen emnes 41 3 SUTRON Overall Table of Contents S Line Touch Panel 2 3 2 etre meer 42 24 Switching ON cece cece eect enne enne nennen nennen 43 2 4 1 Loading Procedure on Windows CE Operating System 43 2 4 1 1 MAU MEN 44 2 4 1 2 Normal MOG 45 2 4 1 3 Setup Main cen imt eet etd eec daas Dore tetigere 45 2 4 1 4 Administration Operating 54 2 5 ldentificatiON 56 2 5 1 ME GDEBCI
28. Mounting Bracket Threaded Pin Mounting Surface Thickness 1 mm to 6 mm Circumferential Seal Front Panel a kh WON S suTRON Installation and Commissioning S Line Touch Panel 2 2 3 9 TP105AT 67 mm 2 637 55 mm 2 165 fa Figure 2 32 TP105AT Mounting Bracket Threaded Pin Mounting Surface Thickness 1 mm to 6 mm Circumferential Seal Front Panel Qc ON 38 S Line Touch Panel Installation and Commissioning 2 2 3 10 120 66 2 598 54 2 126 Figure 2 33 120 Mounting Bracket Threaded Pin Mounting Surface Thickness 1 mm to 6 mm Circumferential Seal Front Panel a WON S suTRON Installation and Commissioning S Line Touch Panel 2 2 3 11 TP151AT 72 mm 2 835 60 mm 2 362 Figure 2 34 151 a kh ON Mounting Bracket Threaded Pin Mounting Surface Thickness 1 mm to 6 mm Circumferential Seal Front Panel 40 S Line Touch Panel Installation and Commissioning 2 3 Connecting the Device 2 3 1 Supply Voltage The supply voltage is supplied via pin strip X1 A suitable socket strip is supplied Refer to the technical data for the permissible supply voltage of the operating de vice The device has reverse polarity protection In case of wrong polarity the device will not operate This is a protection class devic
29. and Commissioning 2 4 1 2 Normal Mode The program AppStarter exe starts from the internal Flash memory Press For Setup Main Menu Figure 2 38 Display after startup Please note that the device is accessible over the Ethernet only after assign ment of an IP address to the Ethernet 2 4 1 3 Setup Main Mode If you press the Press For Setup Main Menu button during the startup phase the Setup Main mode starts Setup Main Touch Screen amp Registry Network Start Settings Batchfile Figure 2 39 Setup Main Some settings are password protected The default password is Update Ne Stick Update Image Update Bootloader Figure 2 40 Update Update Copy USB Stick Copy to Flash Copy to USB Import Settings Figure 2 41 USB Stick Update Copy USB Stick Copy to Flash This function copies the data from the USB stick to the internal flash file system Several projects can be managed in subdirectories below the directory TSvisRT If more than one project is in different subdirectories a choice dialog is displayed Only directories which contain a project file cb are listed 45 A 2 SUTRON Installation and Commissioning S Line Touch Panel The entire TSvisRT directory or the corresponding subdirectory and the AppStarter exe are copied into the target directory of the flash file system Update Copy USB Stick Copy to U
30. date Size of flash Size of SRAM Size of PLC Visu RAM clock speed Start Batchfile The project bat file in the FlashDrv directory starts if available 2 4 1 4 Administration Operating Mode If you press the Admin button during the startup phase the Administration mode of operation starts You can use the Admin ini file to manage the device This file must exist in the root directory of the USB stick This file is used as a dongle to prevent users from changing the device during nor mal operation Possible contents for the Admin ini file Observe upper and lower case for all entries Explorer Off Deactivates the Explorer in the registry The change becomes effective on the next device reboot Explorer On Activates the Explorer in the registry The change becomes ef fective on the next device reboot Start explorer exe Starts the explorer Start MyProgram exe Starts the application MyProgram exe Initial directory is windows Use the following syntax to start an application on the usb stick Start HardDisk MyProgram exe Use multiple entries to start several applications Registry Default Destroys the current registry and activates the default registry of the image The change becomes effective on the next de vice reboot StartRepllog On Enables automatic startup of the Repllog exe program in the registry The change becomes effective
31. eed 96 0 13 site tete ee Lo PR i aa EP HARE PL d 97 6 14 A P31043AT atia Et ee e peel aca 99 6 15 n rti ER tt rudera abre Eo aa D REN BER ag 100 6416 TP120AT ei nr LEER e RE ea ada secre 101 GAT ie idera Ute e ot de a 102 CMI Lre c 103 jo mr sn aaeiee 105 SUTRON Overall Table of Contents S Line Touch Panel SUTRON S Line Touch Panel Important Notes 1 Important Notes HM OBB gt gt 1 1 Symbols The symbols in this manual are used to draw your attention on notes and dangers This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible in jury or death DANGER This indicates a hazardous situation which if not avoided will result in death or serious injury WARNING This indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION This indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE This symbol together with the signal word NOTE and the accompanying text alert the reader to a situation which may c
32. force connection 57234 100 SUTRON 103 Ordering Data S Line Touch Panel 104 Index dera eed 103 Administration operating mode 54 B 81 Battery disposal 82 Cable 68 DeviceNet enisinia 71 Ethernet iiion aiaa an 60 INTERBUS nonnina adia tese 73 75 PROFIBUS i Cr dare 77 Bla 61 Changing the 82 Connectlrig encre 41 D Device variants 59 Diagnostics GAN 69 Device Net ise iss st esce ena eter 71 Ethernet 2i esit 61 065 4 00002 22 73 dig 75 PROFIBUS DP 77 Dimensions 19 Front panel tte dere dato 10 DISPLAY X 57 F Front Panel Dimensions TPOTOA 13 TPOSORA IM iiie tette dei 14 15 TPRAODAT TT 16 TP11AM 11 2 22 2 10 Mai 17 RASTA Tecnica rana rette 18 TP21AM TP21AS TP21AT 10 5
33. on the next device re boot StartRepllog Off Disables automatic startup of the Repllog exe program in the registry The change becomes effective on the next device re boot LaunchTouch On The touch variant of the launch will start at devices with key board The change becomes effective on the next device re boot 54 S Line Touch Panel Installation and Commissioning LaunchTouch Off The standard variant for the device will start The change becomes effective on the next device reboot Lock On The buttons Press for Setup Main Menu and Admin are dis abled If the file Admin ini is found on the usb stick the button Admin is enabled Therefore the deactivation of the lock is possible The change becomes effective on the next device reboot Lock Off All buttons enabled The change becomes effective on the next device reboot Mode Development The shell has full functionality The change becomes effective on the next device reboot Mode Standard The Shell is restricted No task bar and task switch available Desktop contains the launch icon only The change becomes effective on the next device reboot DeviceName MyName Defines the device name of the operating device DeviceName MyName Comment no impact 55 SUTRON Installation and Commissioning S Line Touch Panel 2 5 Identification The operating device can be identified using the nameplate on th
34. x 4 535 Electrical Data Supply voltage 24 V DC SELV PELV in accordance with DIN EN 61131 Residual ripple 10 96 maximum Minimum voltage 18V Maximum voltage 30 V Power consumption typi 0 4 A cal at 24 V Power consumption max 0 6 A imum Connected load 9 6 W Fuse Semiconductor fuse self resetting Protection against polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed anodized natural finish Front panel H x W x mm Inch 126 x 168 x 5 4 961 x 6 614 x 0 197 Seal Circumferential rubber seal on the rear Mounting cutout H x W in mm Inch 118 x 160 4 646 x 6 299 Einbautiefe About 42 1 654 Standard Field Bus Interface About 54 2 126 Degree of protection Front IP65 Rear IP20 Total weight About 690 g 94 S Line Touch Panel Technical Data 6 11 TP57AT Display Type TFT color Resolution pixels 320 x 240 Colors 65536 Reading angle vertical 135 150 horizontal Backlight LED Half life backlighting 40 000 h Brightness in cd m 400 Display area H x W in mm Inch 86 4 x 115 2 3 402 x 4 535 Electrical Data Supply voltage 24 V DC SELV PELV in accordance with DIN EN 61131 Residual ripple 10 maximum
35. 00 000 000 1 WINS 000 000 000 000 2 WINS 000 000 000 000 Figure 2 47 TCP IP Info The following informations are displayed MAC address address Subnet mask address Device name DHCP status Gateway address 1 DNS address 2 DNS address 1 WINS address 2 WINS address Network Settings Fix Settings IP Address IP Address Subnet Mask Figure 2 48 Address The system automatically deselects DHCP and optionally enters the settings from the IPSetting ini file of the USB stick This file must exist in the root directory of the USB stick If no USB stick is connected the information is read from the registry This entry is able to be password protected 48 S Line Touch Panel Installation and Commissioning Contents of the IPSetting ini file IPCONFIG IPAddress 172 016 042 150 SubnetMask 255 255 255 000 Network Settings Fix Settings Gateway Gateway Change Default Gateway 000 000 000 000 Figure 2 49 Gateway The system automatically deselects DHCP and optionally enters the settings from the IPSetting ini file of the USB stick This file must exist in the root directory of the USB stick If no USB stick is connected the information is read from the registry This entry is able to be password protected Contents of the IPSetting ini file IPCONFIG Gateway 172 016 042 150 Network Settings Fix S
36. 1 limit value class DIN EN 55022 limit value class A DIN EN 61000 6 4 Equipment requirements DIN EN 61131 2 Storage and transportation DIN EN 61131 2 Power supply DIN EN 61131 2 84 S Line Touch Panel Technical Data Standards and Guidelines Electromagnetic 2004 108 EG compatibility Degrees of protection DIN EN 60529 Impact load shocks DIN EN 60068 2 27 Sinusoidal vibrations DIN EN 60068 2 6 This is a class A device This device may cause radio interference in residential areas In this case the user may be required to introduce appropriate counter measures and to bear the cost of same NOTICE Radio Interference Approvals CE UL cUL 85 SUTRON Technical Data S Line Touch Panel 6 2 TP11AM Display Type FSTN mono Resolution pixels 320 x 240 Colors 5 Shades of gray Reading angle vertical horizontal 80 80 Contrast setting Temperature compensated Half life backlighting 30 000 h Brightness in cd m 90 Display area H x W in mm Inch 57 6 x 76 8 2 268 x 3 024 Electrical Data Supply voltage 24 V DC SELV PELV in accordance with DIN EN 61131 Residual ripple 10 96 maximum Minimum voltage 18V Maximum voltage 30 V Power consumption typi 0 25 A cal at 24 V Power consumption max 0 3
37. 5 A imum Connected load 6 W Fuse Semiconductor fuse self resetting Protection against polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed anodized natural finish Front panel H x W x D in mm Inch 96 x 130 x5 3 78 x 5 118 x 0 197 Seal Circumferential rubber seal on the rear Mounting cutout H x W in mm Inch 88 x 122 3 465 x 4 803 Mounting depth in mm Inch About 33 1 299 Standard Field Bus Interface About 45 1 772 Degree of protection Front IP65 Rear IP20 Total weight About 500 g 86 S Line Touch Panel Technical Data 6 3 TP11AT Display Type TFT color Resolution pixels 320 x 240 Colors 65536 Reading angle vertical 140 140 horizontal Half life backlighting 30 000 h Brightness in cd m 320 Display area H x W in mm Inch 53 6 x 71 5 2 11 x 2 815 Electrical Data Supply voltage 24 V DC SELV PELV in accordance with DIN EN 61131 Residual ripple 10 maximum Minimum voltage 18V Maximum voltage 30V Power consumption typi 0 2A cal at 24 V Power consumption max 0 3A imum Connected load 4 8 W Fuse Semiconductor fuse self resetting Protection against polarity reversal Integrated Front Panel and Enclosure
38. CAN H CAN H Bus Line 8 nc Not Connected 9 nc Not Connected NOTICE The D SUB connector strips must be shielded sufficiently See chapter Shield ing D SUB Connectors on page 4 79 67 SUTRON Interfaces of the Device S Line Touch Panel D 4 3 1 2 Cable NOTICE A shielded twisted pair cable cable type LiYCY TP complying with ISO 11898 must be used The cable must have the following characteristics Table 4 9 Cable characteristics CAN Parameters Value Impedance Min 108 Ohm Nom 120 Ohm Max 132 Ohm Specific Resistance 70 mOhm m Specific Line Delay 5 ns m The maximum cable length depends on the baud rate used Table 4 10 Baud rate CAN Baudrate Cable length 20 kBit s 1000 m 125 kBit s 500m 250 kBit s 250m 500 kBits 100m 1000 kBit s 25 m 4 3 1 3 Termination Terminate the CAN bus at both ends by terminating resistors 120 Ohm Table 4 11 Termination switch 51 S2 S3 54 Function X X X Termination 120 Ohm X X X No Termination Legend for table Switch ON Switch OFF X 7 Any position 68 S Line Touch Panel Interfaces of the Device 4 3 1 4 Diagnostics A diagnostics LED is located on the rear of the operating device The LED shows the states of the bus system The diagnostics LED on the operating device has the following functio
39. Field Bus Interface About 66 2 598 Degree of protection Front IP65 Rear IP20 Total weight About 1000 g 90 S Line Touch Panel Technical Data 6 7 TP35AM Display Type TFT mono Resolution pixels 320 x 240 Colors 256 Shades of gray Reading angle vertical 150 130 horizontal Half life backlighting 40 000 h Brightness in cd m 220 Display area H x W in mm Inch 52 5 x 70 2 066 x 2 755 Electrical Data Supply voltage 24 V DC SELV PELV in accordance with DIN EN 61131 Residual ripple 10 maximum Minimum voltage 18V Maximum voltage 30 V Power consumption typi 0 3A cal at 24 V Power consumption max 0 4 A imum Connected load 7 2 W Fuse Semiconductor fuse self resetting Protection against polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed anodized natural finish Front panel H x W x D in mm Inch 90 x 120x 5 3 543 x 4 724 x 0 197 Seal Circumferential rubber seal on the rear Mounting cutout H x W in mm Inch 82 x 112 3 228 x 4 409 Mounting depth in mm Inch About 35 1 377 Standard Field Bus Interface About 47 1 85 Degree of protection Front IP65 Rear 20 Total weight About 430 g SUTRON 91
40. I 75 C SUTRON User Manual S Line Touch Panel Part Number 80860 726 Version 5 Date 2013 10 29 Valid for TP11AM TP11AT TP21AM TP21AS TP21AT TP35AT TP57AM TP57AT TPO7OATW TPOSOATW TP104AT TP105AT TP120AT TP151AT S Line Touch Panel Version Date Modifications 1 2008 06 04 First Edition 2 2009 03 10 Added TP57AM and TP57AT 3 2010 11 25 Added TP35AT TP105AT and KNX Interface 4 2012 07 17 Interfaces RS422 RS485 modified Technical data Application area modified Connecting the device Torque specifications added 5 2013 10 29 TP90AT becomes TPOSOATW TP70AT becomes TPO7OATW This manual including all illustrations contained herein is copyright protected Use of this manual by any third party in departure from the copyright provision is forbidden No part of this manual may be reproduced trans lated or electronically or photographically archived or altered without the express written consent from S tron electronic GmbH Violations shall be cause for damage liability S tron electronic reserves the right to make any changes that contribute to technical improvement S SUTRON S Line Touch Panel Overall Table of Contents Overall Table of Contents 1 Important NOTES Uu 7 1 1 SY Were EI 7 1 20 Safety Notes eite eese eR eR DE
41. Interfaces e 291 5 e SZ BEES 5216 522 TPxxxAx 70xxxx TPxxxAx 78xxxx X X X TPxxxAx TAxxxx X 1 X 75 X X X TPxxxAx 76xxxx X X X TPxxxAx 73xxxx X X 72 X X TPxxxAx 80xxxx X X X 59 S SUTRON Interfaces of the Device S Line Touch Panel 4 1 Standard Interfaces Figure 4 1 Rear view Ethernet Female Connector X5 Ethernet Female Connector X9 X10 USB Host Type A Threaded Bolt for Protective Grounding Connector X1 Supply Voltage 4 1 1 Ethernet X5 A 10 100Base T Ethernet interface is located at the operating device 4 1 1 1 Pin Assignment Connector in the operating device RJ45 female connector Table 4 2 Assignment of the Ethernet interface Pin Designation Function 1 Tx Transmitted Data Positive Polarity 2 Tx Transmitted Data Negative Polarity 3 Rx Received Data Positive Polarity 4 n c Not Connected 5 Not Connected 6 Rx Received Data Negative Polarity 7 n c Not Connected 8 n c Not Connected 4 1 1 2 Cable Use twisted pair cable of category 5 5 The maximum cable length is 100 m
42. RON A B 8 9 E ojo 318 122 0 mm 4 803 130 0 mm 5 118 Figure 2 13 TP11AM TP11AT A Mounting Cutout Front Panel 19 Installation and Commissioning S Line Touch Panel 147 0 mm 5 787 139 0 mm 5 472 2 2 2 2 TP21AM TP21AS TP21AT 195 0 mm 7 677 203 0 mm 7 992 Figure 2 14 TP21AM TP21AS TP21AT A Mounting Cutout B Front Panel 20 S Line Touch Panel Installation and Commissioning 90 mm 3 543 82 mm 3 228 2 2 2 3 TP35AM TP35AT 112 mm 4 409 120 mm 4 724 Figure 2 15 TP35AM TP35AT A Mounting Cutout B Front Panel SUTRON 21 Installation and Commissioning S Line Touch Panel 2 2 2 4 100 mm 3 937 92 mm 3 622 132 mm 5 196 140 mm 5 511 Figure 2 16 A Mounting Cutout B Front Panel 22 S Line Touch Panel Installation and Commissioning 126 mm 4 961 118 mm 4 646 2 2 2 5 TP57AM TP57AT 160 mm 6 299 168 mm 6 614 Figure 2 17 TP57AM TP57AT A Mounting Cutout B Front Panel SUTRON 23 Installation and Commissioning S Line Touch Panel 147 0 mm 5 787 139 0 mm 5 472 2 2 2 6 TPO70ATW 195 0 mm 7 677 203 0 mm 7 992 Figure 2 18 TPO7OATW A Mounting Cutout B Front Panel 24 S Line Touch Panel Installation and Commissioning 172 mm 6 772
43. SB Copies the content of the flash file system to the backup directory of the USB stick This excludes protected system files A log file is also transferred which can be used to restore system settings via the Import Settings item Update Copy USB Stick Import Settings An automatically generated log file can be used to restore the system settings If the backup directory of the USB stick contains a corresponding log file these settings can be restored This is possible only when using identical device types Update Update Image If the image subdirectory on the USB stick contains a nbO file this file is used to perform the image update There must be only one nbO file located in this directory otherwise the update does not start In this case the flash registry is always deactivated so that the image is pro cessed with a new default registry Update Update Bootloader If the bootloader subdirectory on the USB stick contains a nbO file this is used to perform the bootloader update There must be only one nbO file lo cated in this directory otherwise the update does not start Update Install Fonts If one or multiple fonts are in the subfolder Fonts of the flash memory these will be installed at the start up of the operating device automatically Depending on the number and size of fonts the system start up take correspond ingly more time Touch
44. Screen amp Registry Touch Screen amp Registry Save Registry Home Settings Change Backlight Display Mode Properties Start SNTP Calibration Settings Figure 2 42 Touch Screen amp Registry Touch Screen amp Registry Save Registry Settings The entire registry is saved Touch Screen amp Registry Change Display Mode Change Display Mode Current Mode LCD Saver gt Vv Figure 2 43 Change Display Mode Set up of display adjustment 46 S Line Touch Panel Installation and Commissioning LCD Saver switches the brightness to the lowest value if no user operation oc cures for at least one hour This entry is able to be password protected Touch Screen amp Registry Start Calibration The touch calibration is started After the calibration the values are stored auto matically in the registry Touch Screen amp Registry Backlight Properties Backlight Timeout in minutes A Use Screensaver Dim Backlight Switch off Backlight s H OK Apply Cancel Figure 2 44 Backlight Properties A screen saver can be activated after the defined time minutes It is possible to adjust the screen saver graphic by replacing the file Screensaver bmp in the in ternal memory The graphic is replaced at the start up of the operating device au tomatically when a USB stick containing the file Screensaver bmp in the Scr
45. aserjet 1505N 52 S Line Touch Panel Installation and Commissioning This entry is able to be password protected Settings Printer Page Settings Page Settings Page Settings Letter A4 Figure 2 61 Page Settings Select the paper format Letter or A4 Letter is default This entry is automatically stored in the registry Settings Printer Network Print Network Print Network Printer Path Network Server Login Figure 2 62 Network Print Enter the network printer path This entry is automatically stored in the registry Settings Printer Network Print Network Server Login Network Server Login User Name Password Domain Figure 2 63 Network Server Login You can save login data for network printing This enables auto login when print ing without manual input at the operating device Enter a user name password and domain This entry is automatically stored in the registry Settings Information SNR 1023456789 Image Grafikpanel EP9307 5 00 _V1 18 Built Aug 27 2007 14 00 00 Flash Size 16 MB SRAM Size 512 kB PLC VISU RAM 0 460 Busclock 49 MHz Click OK to go back to main Figure 2 64 Information 53 SUTRON Installation and Commissioning S Line Touch Panel The following informations are displayed Serial number Product ID Image version Built version Built
46. ause damage or malfunction to the device hardware software or surrounding property This symbol and the accompanying text provide the reader with additional infor mation or refer to detailed sources of information 1 2 Safety Notes Read this manual carefully before using the operating device Keep this man ual in a place where it is always accessible to all users Propertransportation handling and storage placement and installation of this product are prerequisites for its subsequent flawless and safe operation This user manual contains the most important information for the safe opera tion of the device user manual in particular the safety notes must be observed by all per sonnel working with the device Observe the accident prevention rules and regulations that apply to the oper ating site Installation and operation must only be carried out by qualified and trained personnel SUTRON Important Notes S Line Touch Panel 1 3 Intended Use The device is designed for use in the industry device is state of the art and has been built to the latest standard safety requirements However dangerous situations or damage to the machine itself or other property can arise from the use of this device The device fulfills the requirements of the EMC directives and harmonized Eu ropean standards Any modifications to the system can influence the EMC be ha
47. ctions only activate the termination at the cable end For spur lines always deactivate the termination 4 3 4 4 Diagnostics A diagnostics LED is located on the rear of the operating device The LED shows the states of the bus system The diagnostics LED on the operating device has the following functions Table 4 23 Function of the MPI diagnostics LED Color State Function Green Flashing Operating Device has the Token 75 SUTRON Interfaces of the Device S Line Touch Panel 4 3 5 PROFIBUS DP Slave X6 The interface for PROFIBUS DP connections is available to integrate the device into a PROFIBUS DP structure 1 2 3 4 5 25 E 96 Figure 4 15 Rear view PROFIBUS DP 1 Female Connector X5 Ethernet 2 Female Connector X6 PROFIBUS 3 Female Connectors X9 X10 USB Host Type A 4 Threaded Bolt for Protective Grounding 5 Connector X1 Supply Voltage 4 3 5 1 Pin Assignment Figure 4 16 9 pin D SUB female connector strip Connector in the operating device 9 pin D SUB female connector Table 4 24 Pin assignment PROFIBUS DP Pin Designation Function 1 nc Not Connected 2 nc Not Connected 3 RxD TxD P Received Data Transmitted Data Plus red 4 CNTR P Repeater Control Signal Plus 5 DGND Ground for data signals and VP 6 VP Supply Voltage 5 V of Terminators Plus 7 nc Not Connected 8 RxD TxD N Rece
48. e For safe operation safety extra low voltage SELV in accordance with DIN EN 61131 must be used for the supply voltage Connector in the operating device 3 pin pin strip Table 2 1 Pin assignment supply voltage Pin Designation Function 1 Noiseless ground functional earth ground FE 2 OV Supply voltage 0 V GND 3 24 V Supply voltage 24 V NOTICE Damage Cables with finely stranded copper conductors with a minimum cross section of 0 75 mm 18 AWG and a maximum cross section of 2 5 mm 14 AWG must be used for the supply voltage You must adhere to the following torques at the connector Screw connection of terminal blocks 0 22 Nm minimal to 0 25 Nm maximum Screw flange 0 3 Nm maximum DANGER Hazardous voltages Hazardous voltages can exist inside electrical installations that can pose a dan ger to humans Coming in contact with live parts may result in electric shock Use the following procedure to connect the device to the supply voltage 1 Strip approx 30 mm 1 181 off the outer cable sheath and approx 5 mm 0 197 off the wires 5 mm 0 197 30 mm 1 181 Figure 2 35 Preparing the cable Fit the wires with wire end ferrules and connect the wires to the socket strip Plug the socket strip onto pin strip X1 4 Secure the socket strip in place with a screw type locking to prevent it from slipping out 41 SUTRON
49. e rear of the de vice www suetron de Tel 49 711 77098 0 1 Typ 104 1 731030 80850430 113 118 04 101 2 3 000792000133 I e a Un 24 VDC In 0 6 2 2 5 200404210133 Figure 2 65 Nameplate example Order number Version key at time of delivery MAC address Voltage and power specification Serial number ak WON 2 5 1 Version Key The version key provides information on the version level of various components at time of delivery 80850430 113 118 O4XX 101 Bundle Bootloader Image Application Software Installation Auxiliary Software 56 S Line Touch Panel Control and Display Elements 3 Control and Display Elements gt gt 3 1 Display DANGER Toxic If the display is damaged avoid touching swallowing or breathing in the liquids or gases which may leak out DANGER Corrosive If the display is damaged avoid touching swallowing or breathing in the liquids or gases which may leak out NOTICE Damage Static screen parts which displayed over a longer time period gt 1 hour result in so called image sticking Image sticking shows itself visual like a burn in effect The screen displayed before remains visible after a change of image as shade furthermore Higher environmental temperatures du
50. eensaver directory is present The brightness of the backlight dim backlight can be reduced after the defined time minutes and turned off backlight switch off in addition This entry is able to be password protected Touch Screen amp Registry SNTP Settings SNTP Settings Time Synchronization _ Osn Grent Server Server myserver myhost iocal Interval minutes 5 Figure 2 45 SNTP Settings If you activate the SNTP Client option you can enter the address of a time server located in the intranet or Internet The synchronization interval is specified in minutes With the option No SNTP the synchronization is deactivated The operating device may be used as a time server for other devices if the SNTP Server option is active This entry is able to be password protected 47 S SUTRON Installation and Commissioning S Line Touch Panel Network Settings Network Settings TCP IP Info Home Figure 2 46 Network Settings All addresses of the Network Settings have to be entered in the format Numbers smaller than 100 have to be filled up with leading zeros e g 192 168 42 1 gt 192 168 042 001 Network Settings TCP IP Info TCP IP Info MAC 0 7 93 FF FF CE IP 192 168 100 82 Mask 255 255 255 0 Device Name MyName DHCP enabled Gate 000 000 000 000 1 DNS 000 000 000 000 2 DNS 000 0
51. er cap can be obtained directly from S tron electronic 70 S Line Touch Panel Interfaces of the Device D 4 3 2 2 Cable NOTICE A DeviceNet certified cable must be used Table 4 15 Data line DeviceNet Cable Loop Resistance Surge Impedance Capacitance per Type Unit Length 2x 1 1 mm 22 6 Ohm km 120 Ohm 39 4 pf m 2x0 6 mm 91 8 Ohm km 120 Ohm 39 4 pf m The maximum length allowed for spur lines connected to the bus cable is 6 meters The overall length of the bus cable including all spur lines is not to exceed the maximum length listed in the table below The maximum cable length depends on the baud rate and the cable type used Table 4 16 Baud rate DeviceNet Baud Cable Cable Rate Type Length 125 kBit s 2x 1 1 mm 500m 2x0 6 mm 100m 250 kBit s 2 x 1 1 mm 250m 2x0 6 mm 100m 500 kBit s 2x 1 1 mm 100m 2x0 6 mm 100m 4 3 2 3 Termination Terminate the DeviceNet bus at both ends directly at the connector by terminating resistors 120 Ohm 4 3 2 4 Diagnostics A diagnostics LED is located on the rear of the operating device The LED shows the states of the bus system The diagnostics LED on the operating device has the following functions Table 4 17 Functions of the DeviceNet diagnostics LED Color State Function Green Off Terminal is Disconnected from Bus Green On Commu
52. ettings DNS Primary DNS 000 000 000 000 Secondary DNS 000 000 000 000 Figure 2 50 DNS The system deselects DHCP and enters the settings from the IPSetting ini file of the USB stick This file must exist in the root directory of the USB stick If no USB stick is connected the information is read from the registry This entry is able to be password protected Contents of the IPSetting ini file IPCONFIG PrimaryDNS 172 016 042 150 SecondaryDNS 172 016 042 151 Network Settings Fix Settings WINS WINS Primary WINS 000 000 000 000 Secondary WINS 000 000 000 000 Figure 2 51 WINS The system automatically deselects DHCP and optionally enters the settings from the IPSetting ini file of the USB stick This file must exist the root directory of the USB stick If no USB stick is connected the information is read from the registry 49 S SUTRON Installation and Commissioning S Line Touch Panel This entry is able to be password protected Contents of the IPSetting ini file IPCONFIG PrimaryWINS 172 016 042 150 SecondaryWINS 172 016 042 151 Network Settings DHCP DHCP enabled Save registry and restart device to work with new parameters Figure 2 52 DHCP You may enable DHCP service You must save this setting when exiting of by us ing Save Registry Settings This entry is able to be password protected Network Settings FTP Settings Add new user Add new user
53. experts NOTICE Damage For changing the battery you may only use replacement batteries of S tron electronic NOTICE Damage Electrostatic discharge can damage electronic components Observe the ESD protective measures To ensure that the data in the SRAM and the time are preserved it is possible to change the battery under operating voltage Observe the corresponding safety notices Remove the screws on the rear of the device and lift off the enclosure cover Remove the glue strip securing the battery Disconnect the connector from the battery and remove the dead battery Plug in the cable for the new battery Use a glue strip to attach the new battery to the enclosure Place the enclosure cover back onto the device Carefully tighten the screws of the enclosure cover amp WN gt 5 3 2 Battery Disposal The manufacturer is obliged to mark batteries with this symbol before first placing into market The symbol is extended by the chemical symbols if the following lim iting values are exceeded More than 0 0005 mass percent mercury Hg More than 0 002 mass percent cadmium Cd More than 0 004 mass percent lead Pb Batteries can be given back free of charge after use at the place of purchase According to the 811 of the battery law final consumers are obligedly to give old batteries back to gathering points which attached to the common take back sys tem or manufacturer specific take back sys
54. female connector strip Connector in the terminal 9 pin D SUB female connector Table 4 21 Pin assignment Pin Designation Function 1 nc Not Connected 2 nc Not Connected 3 RxD TxD P Received Data Transmitted Data Plus 4 CNTR P Repeater Control Signal Plus 5 DGND Data Transmission Potential 6 VP Supply Voltage of Terminators Plus 7 nc Not Connected 8 RxD TxD N Received Data Transmitted Data Minus 9 CNTR N Repeater Control Signal Minus NOTICE The D SUB connector strips must be shielded sufficiently See chapter Shield ing D SUB Connectors on page 4 79 74 S Line Touch Panel Interfaces of the Device D 4 3 4 2 Cable NOTICE Any cable that conforms with the following parameters can be used Table 4 22 Cable characteristics MPI Parameters Value Loop Resistance 110 Ohm km Capacitance 30 nF km Surge Impedance 150 Ohm The maximum length of one segment is 50 m which cannot be exceeded This 50 m applies from the first node to the last node in the segment For further information on the installation please refer to the Siemens manual SIMATIC 57 400 and M7 400 Programmable Controllers Hardware and Instal lation 6 57498 8 03 8 4 3 4 3 Termination The bus line is terminated at the connector For point to point connections always activate the termination For multi point conne
55. ient heat dissipation Please observe the permissible temperature range specified in the technical data of the user manual when operating the device NOTICE Damage In order to ensure the degree of protection specified in the technical data al ways make sure that the seal lies flat against the mounting surface and the threaded pins of the mounting brackets are tightened uniformly to a maximum torque of 1 Nm The device can be easily and quickly mounted from the rear of the device A panel thickness of 1 mm to 6 mm 0 039 to 0 236 is permitted for proper mounting 1 Insert the device in the mounting cutout from the front aim lt T Figure 2 1 Mounting the device using a mounting bracket 2 Insert the mounting brackets into the appropriate openings figure 1 and pull the brackets downwards until they lock in place 2 3 Fasten the device into position using the threaded pins 3 SUTRON Installation and Commissioning S Line Touch Panel 2 2 1 Front Panel Dimensions 2 2 1 1 TP11AM TP11AT 96 0 3 78 SUTRON av 130 0 mm 5 118 l Figure 2 2 TP11AM TP11AT 2 2 1 2 21 TP21AS 21 2 RS i E 5 b gt Bor D 203 0 mm 7 992 Figure 2 3 TP21AM TP21AS TP21AT 10 S Line Touch Panel Installation and Commissioning 2 2 1 3 TP35AM TP35AT A 5 e z
56. ioning S Line Touch Panel 2 4 1 1 Launch Structure Start gt Normal Admin L Setup Main gt Update lt I 9 Copy USB Stick gt to Flash to USB y Import Settings Home Update Image Update Bootloader gt Install Fonts Home TouchScreen amp Registry Save Registry Settings Change Display Mode L Start Calibration Backlight Properties 9 5 Settings Home Network Settings i gt TCP IP Info Fix Settings gt IP Address y Gateway DNS WINS Home gt DHCP FTP Settings p gt Add new user List all users Delete a user gt Home Device Name Home gt Settings gt Contrast Date Time E Password Printer 4 Settings Network Print Home gt Information Start Batchfile Exit Y Figure 2 37 Launch structure 44 S Line Touch Panel Installation
57. ived Data Transmitted Data Minus green 9 CNTR N Repeater Control Signal Minus NOTICE The D SUB connector strips must be shielded sufficiently See chapter Shield ing D SUB Connectors on page 4 79 76 S Line Touch Panel Interfaces of the Device D 4 3 5 2 Cable NOTICE A can be used Any PROFIBUS DP approved cables specified in the EN 50170 as cable type Table 4 25 Cable characteristics PROFIBUS Parameters Value Impedance 136 to 165 Ohm Capacitance 30 pf m Loop Resistance 110 Ohm km Wire Gauge 0 64 mm The maximum cable length depends on the baud rate DIN EN 19245 Part 3 Table 4 26 Baud rate PROFIBUS DP Baud Rate Cable Length 187 5 kBit s 1000 m 500 kBit s 400 m 1500 kBit s 200m 3000 to 12000 kBit s 100m 4 3 5 3 Termination Terminate the PROFIBUS at both ends by terminating resistors If you are using special PROFIBUS connectors these resistors are usually integrated into the connector and can be connected 4 3 5 4 Diagnostics A diagnostics LED is located on the rear of the operating device The LED shows the states of the bus system The diagnostics LED on the operating device has the following functions Table 4 27 Function of the PROFIBUS DP diagnostics LED Color State Function Green ON Communication Ac tive 77 SUTRON Interfaces of the Device
58. log If you press Cancel or 5 seconds pass without any ac tion the value is not accepted Depending on the display type different values can be influenced Display Type Contrast Brightness STN mono X STN color X X TFT X Selection of color depth for TFT displays This entry is able to be password protected 51 SUTRON Installation and Commissioning S Line Touch Panel Settings Date Time Date Time Current Time 00 A 15 00 00 AM Time Zone GMT 01 00 Amsterdam Berlin Bern Rome Automatically adjust clock for daylight saving Figure 2 58 Date Time Set the date time and time zone Settings Password Password Current Password b Enable Password OK Cancel Figure 2 59 Password The password can be activated deactivated or redefined When the password is activated all password protected dialog boxes can only be accessed if the pass word has been entered successfully This entry is able to be password protected Settings Printer Page Network Settings Print Figure 2 60 Printer The print function depends on the application program on the operating device Connection of a printer is possible via the network and the USB interface The op erating system supports PCL3 compatible printers Table 2 2 Already used printer models Model HP OfficeJet 6000 HP OfficeJet Pro 8000 HP DeskJet 6940 HP DeskJet 5150 HP L
59. n only at the two ends of the lines in a 2 or 4 wire multi point connection RS422 RS485 T B R A R B Figure 4 5 Termination possibilities RS422 RS485 internal Table 4 5 Resistor values termination RS422 RS485 Designation Value R1 R3 510 Ohm R2 150 Ohm R4 120 Ohm The switch positions for ON or OFF are printed onto the termination switch Only the specified switch positions are allowed Table 4 6 Termination switch Bus S1 S2 S3 54 Function Transmitter Receiver 2 wire OFF OFF OFF OFF Termination is OFF 4 wire Line termination is assured by other participants The quiescent level is ensured by external wiring RS422 RS485 unused 2 wire ON ON OFF OFF Transmitter Termination is ON Guarantees quiescent level Receiver Termination is OFF 4 wire ON ON ON ON Transmitter Termination is ON Receiver Termination ON Point to point or multi point con nection at the end of the line 64 S Line Touch Panel Interfaces of the Device oo 4 2 2 RS232 X6 The serial RS232 interface is suitable to establish a point to point connection 4 2 2 1 Pin Assignment 13 1 25 14 Figure 4 6 25 pin D SUB female connector strip Connector in the operating terminal 25 pin D SUB female connector Table 4 7 Pin assignment RS232
60. nication Active Green Flashing Sporadic Bus Error 71 SUTRON Interfaces of the Device S Line Touch Panel 4 3 3 INTERBUS Slave X6 X7 The device can be integrated into the INTERBUS using the interfaces available for INTERBUS connections 1 2 6 Figure 4 11 Rear view INTERBUS Female Connector X5 Ethernet Female Connector X6 INTERBUS Remotebus Out Female Connector X9 X10 USB Host Type A Threaded Bolt for Protective Grounding Male Connector X7 INTERBUS Remotebus In Connector X1 Supply Voltage WN 4 3 3 1 Pin Assignment 1 5 5 1 6 9 9 6 Figure 4 12 9 D SUB male connector strip female connector strip Connector in the terminal 9 pin D SUB male connector strip for remote bus in Table 4 18 Pin assignment remote bus in INTERBUS Pin Designation Function 1 DO Data Input 2 DI Data Output 3 GND Ground 4 nc Not Connected 5 nc Not Connected 6 DO Data Input Inverted 7 101 Data Output Inverted 8 nc Not Connected 9 nc Not Connected 72 S Line Touch Panel Interfaces of the Device Connector in the terminal 9 pin D SUB female connector strip for remote bus out Table 4 19 Pin assignment remote bus out INTERBUS Pin Designation Function 1 DO Data Output 2 DI Data Input 3 GND Ground 4 nc Not Connected
61. ns Table 4 12 Functions of the CAN diagnostics LED Color State Function Green Off Terminal Disconnected from Bus Green On Communication Active Green Flashing Sporadic Bus Error 4 3 1 5 Slope Control The slope control switch is located on the rear of the operating device You can use the slope control switch to set the edge steepness of the CAN sig nals By default the operating devices are used with the switch set to High Table 4 13 Slope control switch 51 S2 53 54 Function X X X High speed X X X Low speed Legend for table Switch ON Switch OFF X 7 Any position 69 SUTRON Interfaces of the Device S Line Touch Panel 4 3 2 DeviceNet Slave X6 Figure 4 9 Rear view DeviceNet slave Female Connector X5 Ethernet Female Connectors X9 X10 USB Host Type A Connector X6 DeviceNet Threaded Bolt for Protective Grounding Connector X1 Supply Voltage o WON 4 3 2 1 Pin Assignment Figure 4 10 5 pin connector Connector in the operating terminal 5 pin male connector strip Table 4 14 Pin assignment DeviceNet Pin Designation Function 1 nc Not Connected 2 CAN L CAN L Bus Line 3 Drain Shield 4 CAN H CAN H Bus Line 5 nc Not Connected For the connection use a 5 pin connector with gold plated contacts and cover cap A suitable connector with cov
62. ntegrated Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed anodized natural finish Front panel H x W x D in mm Inch 249 x 328 x 5 9 803 x 12 913 x 0 197 Seal Circumferential rubber seal on the rear Mounting cutout H x W in mm Inch 222 x 303 8 740 x 11 929 Mounting depth in mm Inch About 55 2 165 Standard Field Bus Interface About 67 2 638 Degree of protection Front IP65 Rear 20 Total weight About 2300 g SUTRON 99 Technical Data S Line Touch Panel 6 15 TP105AT Display Type TFT color Resolution pixels 800 x 600 Colors 65536 Reading angle vertical 110 140 horizontal Backlight CCFL Half life backlighting 50 000 h Brightness in cd m 330 Display area H x W in 158 x 211 mm Inch 6 22 x 8 307 Electrical Data Supply voltage 24 V DC SELV PELV in accordance with DIN EN 61131 Residual ripple 10 96 maximum Minimum voltage 18V Maximum voltage 30V Power consumption typi 0 6A cal at 24 V Power consumption max 0 8 A imum Connected load 14 4 W Fuse Semiconductor fuse self resetting Protection against polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed anodi
63. odized natural finish Front panel H x W x D in 147 203 5 mm Inch 5 787 x 7 992 x 0 197 Seal Circumferential rubber seal on the rear Mounting cutout H x W 139 x 195 in mm Inch 5 7472 x 7 677 Mounting depth in mm About 54 2 126 Inch Standard Field Bus Interface About 66 2 598 Degree of protection Front IP65 Rear IP20 Total weight About 1000 g 88 S Line Touch Panel Technical Data 6 5 TP21AS Display Type C STN color Resolution pixels 320 x 240 Colors 256 Reading angle vertical 60 100 horizontal Contrast setting Temperature compensated Half life backlighting 50 000 h Brightness in cd m 200 Display area H x W in mm Inch 86 4 x 115 2 3 402 x 4 535 Electrical Data Supply voltage 24 V DC SELV PELV in accordance with DIN EN 61131 Residual ripple 10 maximum Minimum voltage 18V Maximum voltage 30V Power consumption typi 0 4 A cal at 24 V Power consumption max 0 5 A imum Connected load 9 6 W Fuse Semiconductor fuse self resetting Protection against Integrated polarity reversal Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed anodized natural finish Front panel H x W x D mm Inch 147 x 203 x 5 5 787 x 7 992 x 0 197 Seal Circumferential rubber seal on the rear
64. onsumption max 0 7 A imum Connected load 12W Fuse Semiconductor fuse self resetting Protection against polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed anodized natural finish Front panel H x W x D in mm Inch 147 x 203 x 5 5 787 x 7 992 x 0 197 Seal Circumferential rubber seal on the rear Mounting cutout H x W in mm Inch 139 x 195 5 7472 x 7 677 96 S Line Touch Panel Technical Data Front Panel and Enclosure Mounting depth in mm Inch About 42 1 654 Standard Field Bus Interface About 54 2 126 Degree of protection Front IP65 Rear IP20 Total weight About 1000 g 6 13 TPO90ATW Display Size diagonal in cm 22 86 9 inch Type TFT color Resolution pixels 800 x 480 Colors 65536 Reading angle vertical 170 170 horizontal Backlight LED Half life backlighting 70 000 h Brightness in cd m 400 Display area H x W in mm Inch 118 x 197 4 645 x 7 755 Electrical Data Supply voltage 24 V DC SELV PELV in accordance with DIN EN 61131 Residual ripple 10 maximum Minimum voltage 18 V Maximum voltage 30 V Power consumption typi 0 6 A cal at 24 V Power consumption max 0 8 A imum Connected load 14 4 W
65. ring the operation can accelerate this effect To avoid the danger of an irreversible damage the display must time controlled 15 minutes are recommended set with a black screen Image sticking is a tech nologically property and only can be prevented by a suitable application Image sticking is not appreciated by display suppliers as a guarantee reason Please follow the instructions in the programming software s help topic How do configure black screen as a screen saver for making such a screen The operating device is equipped with different displays depending on variant 3 1 1 Touch Screen The device is equipped with a resistive 4 wire touch screen You operate the de vice using this touch screen NOTICE Damage Pointed or sharp objects such as pens or fingernails can lead to irreparable damages of the touch screen Exclusively therefore use the fingertips or the aids indicated in the technical data for the operation NOTICE Damage To protect the touch screen you can use special protection foils You receive corresponding protection foils directly from S tron electronic 57 SUTRON Control and Display Elements S Line Touch Panel 58 S Line Touch Panel Interfaces of the Device 4 Interfaces of the Device Depending on the device variant several interfaces are available to you Table 4 1 Device Variants Order Number Available
66. rsal serial bus specification Rev 2 0 X9 X10 Host Min 1 5 Mbit s Max 12 Mbit s Max output current 100 mA per output 83 SUTRON Technical Data S Line Touch Panel Central Processing Unit Central processing unit RISC 9 Clock frequency 200 MHz Other features Watchdog timer real time clock battery monitoring Memory Application memory op tion 3 MByte 14 MByte Flash option 16 MByte 32 MByte SDRAM option 32 MByte 64 MByte SRAM option 512 KByte 512 KByte Connection System D SUB female and male connector strips 9 pin and 25 pin Female and male connector strips Phoenix COMBICON MINI COMBICON 3 pin Male connector strip Phoenix COMBICON 5 pin RJ45 female connector USB female connector A Environmental Conditions Temperature during operation 0 C to 50 C 32 F to 122 F Temperature during storage transport 25 to 70 C 13 F to 158 F Relative air humidity for operation and storage 20 to 85 no condensation Application area Degree of pollution 2 overvoltage category III No direct solar radiation Standards and Guidelines Interference immunity DIN EN 61000 4 2 DIN EN 61000 4 3 DIN EN 61000 4 4 DIN EN 61000 4 5 DIN EN 61000 4 6 DIN EN 61000 6 2 Emitted interference DIN EN 5501
67. tect the device Once the fuse has been tripped the device must be disconnected from the supply voltage to allow the semiconductor fuse to regenerate At an ambient temperature of 20 C 68 F the regeneration takes approximately 20 seconds The higher the ambient tem perature the longer the regeneration takes 5 3 Battery The built in battery preserves the data in the SRAM and supplies the real time clock with power The minimum battery life is 5 years even under unfavorable op erating conditions When the battery runs down the message Change battery is generated automatically We recommend you change the battery approximately every 4 years as part of the regular maintenance work A prepared battery including connector can be ob tained directly from S tron electronic If the Change battery message is detected too late data in the SRAM may have already been lost For this reason after changing a battery always check data such as editable passwords parameters in the system variables data sets of the recipes and entries in the message system 81 SUTRON Maintenance and Servicing S Line Touch Panel A A D D Q 5 3 1 Changing the Battery CAUTION Explosive Do not throw lithium batteries into fire do not heat to 100 C or higher and do not recharge CAUTION Toxic Do not open lithium batteries NOTICE Damage Batteries must only be changed by authorized and trained
68. tems NOTICE Damage To prevent short circuitry in the collection boxes insulate the poles of each bat tery with insulation tape or put each single battery into a plastic bag 82 S Line Touch Panel Technical Data 6 Technical Data 6 1 General Touch Screen Type Analog resistive 4 wire technology Activation force 15 g Standard With R8 HS60 silicon rubber Durability No damages or malfunctions after 3 million keystrokes as the following Keystroke element R8 HS40 silicon rubber Keystroke load 150 g Keystroke frequency 3 Hz Ethernet X5 Ethernet 10 100Base T Serial Interfaces Variable baud rates and data formats X6 RS422 RS485 In accordance with DIN 66259 4 Transmission length 0 1200 m twisted pair wire shielded galvanically iso lated X6 RS232 In accordance with DIN 66259 T1 CCITT V 28 Transmission length 0 15 m conductors layered in strands shielded galvanically isolated Field Bus Interfaces Variable baud rates and data formats X6 CAN In accordance with ISO 11898 Galvanically Isolated X6 DeviceNet In accordance with ISO 11898 Galvanically isolated X6 MPI Galvanically isolated X6 PROFIBUS DP Galvanically isolated X6 KNX Galvanically isolated X6 X7 INTERBUS Galvanically not isolated galvanically isolated USB Corresponds to the Unive
69. tion and Commissioning 2 2 3 4 54 mm 2 125 42 mm 1 653 Figure 2 27 Mounting Bracket Threaded Pin Mounting Surface Thickness 1 mm to 6 mm Circumferential Seal Front Panel ak WON S SUTRON 33 Installation and Commissioning S Line Touch Panel 2 2 3 5 TP57AM TP57AT 54 mm 2 126 42 mm 1 654 Figure 2 28 TP57AM TP57AT Mounting Bracket Threaded Pin Mounting Surface Thickness 1 mm to 6 mm Circumferential Seal Front Panel a kh WON 34 S Line Touch Panel Installation and Commissioning 2 2 3 6 TPO70ATW 54 mm 2 125 42 mm 1 653 OQUOOIQIOOOQOQUO QUOOQDOQOOOQO OUCOO gt OOOOWOOCOO0 OODOOQDOQOCQQO Q a A N Figure 2 29 TPO70ATW 1 2 3 4 5 Mounting Bracket Threaded Pin Mounting Surface Thickness 1 mm to 6 mm Circumferential Seal Front Panel 35 SUTRON Installation and Commissioning S Line Touch Panel 2 2 3 7 TP090ATW 66 mm 2 598 54 mm 2 126 Figure 2 30 90 Qo WON Mounting Bracket Threaded Pin Mounting Surface Thickness 1 mm to 6 mm Circumferential Seal Front Panel 36 S Line Touch Panel Installation and Commissioning 2 2 3 8 TP104AT 67 mm 2 638 55 mm 2 165 Figure 2 31 TP104AT
70. vior NOTICE Radio Interference This is a class A device This device may cause radio interference in residential areas In this case the user may be required to introduce appropriate counter measures and to bear the cost of same 1 4 Target Group The use of products described in this manual is oriented exclusively to Qualified electricians or persons instructed by them who are familiar with ap plicable standards and other regulations regarding electrical engineering and in particular the relevant safety concepts Qualified application programmers and software engineers who are familiar with the safety concepts of automation technology and applicable standards S Line Touch Panel Installation and Commissioning 2 Installation and Commissioning 2 1 Unpacking the Device Unpack all parts carefully and check the contents for any visible damage in transit Also check whether the shipment matches the specifications on your delivery note If you notice damages in transit or discrepancies please contact us immediately 2 2 Mounting the Device NOTICE Damage When installing the device leave a gap of at least 30 mm 1 181 around the device to ensure sufficient air circulation 7 NOTICE Damage When the operating device is installed horizontally please note that additional sources of heat beneath the operating device may result in heat accumulation Make sure to allow suffic
71. zed natural finish Front panel H x W x D in mm Inch 220x295x5 8 661 x 11 614 x 0 196 Seal Circumferential rubber seal on the rear Mounting cutout H x W in mm Inch 212 x 287 8 346 x 11 299 Mounting depth in mm Inch About 55 2 165 Standard Field Bus Interface About 67 2 638 Degree of protection Front IP65 Rear IP20 Total weight About 1800 g 100 S Line Touch Panel Technical Data 6 16 TP120AT Display Type TFT color Resolution pixels 800 x 480 Colors 65536 Reading angle vertical 130 130 horizontal Half life backlighting 50 000 h Brightness in cd m 280 Display area H x W in 262 x 157 mm Inch 10 315 x 6 181 Electrical Data Supply voltage 24 V DC SELV PELV in accordance with DIN EN 61131 Residual ripple 10 maximum Minimum voltage 18V Maximum voltage 30 V Power consumption typi 0 7 A cal at 24 V Power consumption max 0 9 A imum Connected load 16 8 W Fuse Semiconductor fuse self resetting Protection against polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed anodized natural finish Front panel H x W x D mm Inch 225 x 330 x 5 8 858 x 12 992 x 0 197 Seal Circumferential rubber seal on the rear