Home
ISO15693 Reader - SL015B-3 User Manual
Contents
1. Checksum error Data AFI data written if operation is succeeds 1 bytes 4 4 6 Write DSFID Checksum Data The DSFID data to write 1 bytes Response Status 0x00 Operation succeed Ox01 No tag 0x05 Write fail 0x06 Unable to read after write 0x07 Read after write error OxFO Checksum error Data DSFID data written if operation is succeeds 1 bytes 4 4 7 Lock block Checksum Block The block number to be locked 1 byte Response Checksum Status 0x00 Operation succeed Ox01 No tag 0x11 Lock fail OxFO Checksum error http www stronglink rfid com 8 StrongLink SL015B 3 4 4 8 Lock AFI OxBA Response 0x38 Status 0x00 Operation succeed Ox01 No tag 0x11 Lock fail OxFO Checksum error 4 4 9 Lock DSFID OxBA Response 0x39 Status 0x00 Operation succeed Ox01 No tag 0x11 Lock fail OxFO Checksum error 4 4 10 Control PA status Mask PAx which to change bit to bit Value The status level Response Status 0x00 Operation succeed OxFO Checksum error Example If you want PA3 to go low you can send OxBA 0x04 0x40 0x08 0x00 OxF6 4 4 11 Reset OxFF Response None http www stronglink rfid com 9
2. SL015B 3 4 4 Command List 4 4 1 Get tag information Response 0x31 UID Status 0x00 Operation succeed Ox01 No tag 0x04 Read fail OxFO Checksum error UID The Unique Identifier of card 8 bytes AFI The Application Family Identifier 1 byte DSFID The Data Storage Format Identifier I byte Type 0x31 Tag it HFI 0x32 I CODE SLI 4 4 2 Get block security status block block Start block number number Number of blocks to be read Response Status 0x00 Operation succeed Ox01 No tag 0x04 Read fail OxFO Checksum error Data Security status 1 byte to 1 block 4 4 3 Read blocks block block Start block number number Number of blocks to be read max 15 blocks Response Status 0x00 Operation succeed Ox01 No tag 0x04 Read fail OxFO Checksum error Data Blocks data returned if operation succeeds 4 bytes to 1 block 4 4 4 Write data to a block Block The block number to be written 1 byte Data The data to write 4 bytes Response http www stronglink rfid com 7 StrongLink SL015B 3 Status 0x00 Operation succeed Ox01 No tag 0x05 Write fail 0x06 Unable to read after write 0x07 Read after write error OxFO Checksum error Data Block data written if operation is succeeds 4 bytes 4 4 5 Write AFI Checksum Data The AFI data to write 1 bytes Response Status 0x00 Operation succeed Ox01 No tag 0x05 Write fail 0x06 Unable to read after write 0x07 Read after write error OxFO
3. 5 x 7 mm e Two LEDs green led is auto light when tag in detection range red led is controlled by host e The PAI pin at low level indicates tag in detective range and high level indicating tag out http www stronglink rfid com 3 StrongLink SL015B 3 2 PINNING INFORMATION H EN ma m Naa ma ikm SC se ag ag FR CH BE PALALA IMU a je Sint Bi IE ice LULU CI ULE a LI l a J m see SU SOC TLL ie Tl 7 ee 10 Lol LILLE TLL IE I r Con O O SLO15B May 05 O HOLE Dia 3 0mm x 2 PIN SYMBOL TYPE DESCRIPTION 1 TXD Output Serial output port 2 RXD Input Serial input port 3 VCC PWR Power Supply 4 GND PWR Ground 5 GND PWR Ground 6 VCC PWR Power Supply 7 PAO Output Tag detect signal low level indicating tag in 8 Pa nen re paa high level ine a out 9 PA2 Output 10 PA3 Output 11 PA4 Output 12 PAS Output 13 PAG Output 14 PA7 Output 15 GND PWR Ground http www stronglink rfid com 4 StrongLink SL015B 3 3 BAUD RATE SETTING R6 amp R7 are two 0 ohm resistances assembled on the bottom layer of module are used for setting baud rate as follows sheet Baud Rate bps 9 600 19 200 57 600 115 200 4 COMMUNICATION PROTOCOL 4 1 Communication Setting The communication protocol is byte oriented Both sending and receiving bytes are in hexadecimal format The communication para
4. RFID MODULE ISO15693 Reader Writer SL015B 3 User Manual Version 1 5 Dec 2011 StrongLink StrongLink SL015B 3 CONTENT 2 PINNING INFORMATION DORE EEE EEE ee EE EEE EEE EE eee ee ee 4 ja MMUNICATION PROTOCOL ces ceseceseceeceneeeseeeseeeees ommunication SE NE vekene ommunication POTMAL 4 a AG GAGA AG ommand OvervieWw rranvrnnnnvvnnnnnnnnnnvnennnnnennnnnensnnnernnuveennnnennnnevnnnnesennnesen 4A Command ES 4 4 1 Get tag information re 4 4 2 Get block security status 4 4 3 Read blocks dd amd ae ann die 4 4 4 Write data to a block rrovvoronnvorrnnvvrnnnnvrnnnnvrnnnnevrnnnvvennnevennnevennnesenneeeenn 4 4 5 Write KA AA 4 4 6 Write DSFID AA TN EE GN EEE 4 4 9 Lock DSFID NSG 4 4 10 Control PA status ss sssrsisasesnnecat eneeatiesat enesensectesndnttene TA a a E an SEES AAA 1 2 3 QAQA ND NO NO NO 00 O0 O0 YAN NTIN UA Un http www stronglink rfid com 2 StrongLink SL015B 3 1 MAIN FEATURES iii ii gt E EEC i E wich R3 R2 C15 LI C7 C8 L2 Ej RI Y Slave leave C5 C13 cu C C14 C12 9 SLO15B Ver2 0 9 e Tags supported I CODE SLI Tag it HFI e Auto detecting tag e Integrated antenna e RS232 interface baud rate 9 600 115 200 bps e 4 5 to 5 5V VDC supply e Operating distance Up to 80mm depending on tag e Storage temperature 40 C 85 C e Operating temperature 20 C 70 C e Dimension 85 x 5
5. meters are as follows Baud rate 9 600 115 200 bps Data 8 bits Stop 1 bit Parity None Flow control None 4 2 Communication Format Host to Reader Preamble Preamble 1 byte equal to OxBA Len 1 byte indicating the number of bytes from Command to Checksum Command 1 byte Command code see Table 3 Data Variable length depends on the command type Checksum 1 byte XOR of all the bytes from Preamble to Data Reader to Host Preamble Checksum Preamble 1 byte equal to OxBD Len 1 byte indicating the number of bytes from Command to Checksum Command 1 byte Command code see Table 3 Status 1 byte Command status see Table 4 Data Variable length depends on the command type Checksum 1 byte XOR of all the bytes from Preamble to Data http www stronglink rfid com 5 StrongLink SL015B 3 4 3 Command Overview Table 3 Command Description 0x31 Get tag information 0x32 Get block security status 0x33 Read blocks 0x34 Write a data block 0x35 Write AFI 0x36 Write DSFID 0x37 Lock block 0x38 Lock AFI 0x39 Lock DSFID 0x40 Control PA status OxFF Reset Status Overview Table 4 Status Description 0x00 Operation succeed 0x01 No tag 0x04 Read fail 0x05 Write fail 0x06 Unable to read after write 0x07 Read after write error OxFO Checksum error OxF1 Command code error http www stronglink rfid com 6 StrongLink