Home

601-321B - WIN 3000 User Manual english.indd

image

Contents

1. rw ma dd lai lem bem ane u WIN 3000 main window Click the connection icon on the lower right corner to display the following window WIN 3000 Remote control software Connection 31 Generators Found IP Address Port Name Description 172 20 32 272 1025 Add Delete Connect Connect Connection window All NSGs in the LAN environment will be listed Typically only one unit is con nected but if several are found then the names and descriptions of each unit can be changed by clicking Edit in the lower left corner of the window 7 1 Edit button The following example shows the Edit Generator window with a name and description added for an NSG 3040 Click OK to save the names and descrip tions Connection Edit Generator IP Address i c ccc Port Name NSG 3040 Description place Connection Edit Generator window T3SEO Advanced Test Solutions for EMC 32 7 2 Add and delete button If no connection is found WIN 3000 automatically switches to UDP protocol to find a unit Since this protocol uses a lower communication level then TCP IP the firewall must be switched off for an effective search UDT is built on top of User Datagram Protocol UDP by adding congestion control and reliability control mechanisms UDT is an application level con nection o
2. WIN 3000 REMOTE CONTROL SOFTWARE USER MANUAL 601 321B Advanced Test Solut ions for EMC WIN 3000 REMOTE CONTROLE SOFTWARE USER MANUAL CONTENTS 2 1 2 2 3 1 S 32 on 3 0 4 1 4 2 4 3 4 3 1 2 9 2 4 3 3 4 3 4 4 3 5 4 3 6 4 3 7 4 3 8 4 3 9 4 3 10 4 3 11 4 3 12 4 3 13 2 Explanation of warning and caution symbols Introduction General description PC hardware requirement Software requirements Microsoft DotNetFramwork What is NET Framework Microsoft Office Interop Word Modifying the Office 2003 setup using setup disc Checking for files Installation Firmware and hardware compatibility check Light version vs fully licensed version Windows description Header bar Menu bar File shortcuts Pulse selection buttons Pulse parameter window Graphical information Parameter flow Sequencer Test library Test step Start pause stop buttons Control shortcuts Connection status NSG system setup NSG Ethernet address co CON 10 10 11 12 14 15 15 15 16 18 18 18 18 19 20 20 21 2 22 22 22 22 23 zo odo 91 2 Oslo 9 1 4 6 1 6 1 1 6 1 2 6 2 7 1 72 7 3 4 8 1 82 8 2 1 8 2 2 92 9 8 2 4 9 2 9 8 2 6 9 2 7 8 2 8 8 3 8 3 1 83 3 8 3 4 5 9 9 9 6 6 7 8 4 8 4 1 8 4 2 IP Address Subnet Gateway Port MAC address Connection to an NSG 3000 family generator system Peer to peer connection using a crossover cabl
3. 2 X Parameter How Bur 2 X Runtime Display x Alt Burst Repetition 30 Volt 7 Frequency 5 kHz Burst Time _ Frequency Phase aude 9 Repetition Time Burst Time 75 Spikes Graphic Burst Elec Coupling m Output 300 500 E Burst Output 1000 400 Alt T 100 Burst Output Total Test Step Total Test Time Test Duration Count Approx Test Time Ron by St DF Od 1h 26min 8s EN m Runtime display window when EUT fault is generated Refer to the NSG user manual for the correct EUT fail setting T3SEO Advanced Test Solutions for EMC Headquarters Teseq AG 4542 Luterbach Switzerland T 41 32 681 40 40 F 41 32 681 40 48 sales Qteseq com WWVW teseq com China Teseq Company Limited T 86 10 8460 8080 F 86 10 8460 8078 chinasales teseg com Germany Teseq GmbH T 49 30 5659 8835 F 49 30 5659 8834 desales teseq com Singapore Teseq Pte Ltd T 65 6846 2488 F 65 6841 4282 singaporesales Qteseq com Taiwan Teseq Ltd T 886 2 2917 8080 F 886 2 2917 2626 taiwansales teseq com USA Teseq Inc T 1 732 417 0501 1 732 417 0511 Toll free 1 888 417 0501 usasales teseq com To find your local partner within Teseq s global network please go to WWW teseq com Manufacturer Teseq AG 4542 Luterbach Switzerland T 41 32 681 40 40 F 41 32 681 40 48 sales teseg com Fran
4. 3o so 10 Spes 1 150 ms 25 msn 106 IEC L1 3 V 200 VI Pos KHz 3 Na gam a 3 100 150 ms 235 matin ig 200 pono V 200 Pos 353 3G SSO Spies 10 Spikes Lin LS mz 25 m in lis PE 201000 V MOVIL Pos J ho WI ho Da LTH 25 1905 IEC LL N ju Lj Pos 1 S50 9 XH SSG Spies 10 Lan 10 156 ms J5 matin le TEE Li PE Test Step Screen 4 3 11 Start pause stop buttons These buttons allow the user to control the generator with START PAUSE and STOP commands 4 3 12 Control shortcuts The control shortcut buttons are used to control program flow generator func tions and request test reports 4 3 13 Connection status This button displays the connection status of WIN 3000 to the NSG 3000 gen erator The icon is green when the generator is connected and red when it is not connected Note Communication is established by clicking the communication icon on the NSG 3000 To disconnect the NSG 3000 click the generator s EXIT button WIN 3000 Remote control software 5 NSG SYSTEM SETUP WARNING Lethal danger from high voltages and the risk of radiating illegal electromagnetic interference The NSG 30xx must only be used for EMC test purposes as described in the NSG user manual The NSG 30xx must be installed and operated only by trained EMC specialists Personnel fitted with heart pacemakers must not operate the NSG
5. Click Delete selected Note Standard tests cannot be deleted 8 4 7 Last used To load the last test used Click Last used The last four tests loaded are displayed Click to load the selected test 8 5 View The View menu allows the user to customize the WIN 3000 workspace There are seven windows that can be displayed in the WIN 3000 workspace Graphic parameter parameter flow dialog test library test steps and runtime The user can move resize hide close or pin each of these windows to custom ize the workspace See section 9 for instructions on resizing and rearranging Windows View Dialogue Help Graphic Default Workspace Parameter Save Workspace Parameter Flow Restore Workspace Dialog ge Test Library put Ev Test Steps Runtime View windows menu WIN 3000 Remote control software 8 5 1 Windows 51 To restore windows which have been closed hidden or pinned Click Windows Click to select a window The window is displayed in the workspace 8 5 2 Default workspace To reset the WIN 3000 workspace to its default display Click Default workspace 8 5 3 Save workspace To save the current customized workspace for the next WIN3000 session Click Save workspace Only one customized workspace can be saved 8 5 4 Restore workspace To restore the current saved workspace Click Restore workspace 8 6 Dialog The dialog menu is used to create customi
6. Programme Teseq AGWIN 3000 StandardTests IEC 61000 4 5 Ed22005 Telecom Pulse Test Shielded I Lines Level 3 tel rst Ime CProgramme Teseq AG WIN 3000 StandardTests IEC 61000 4 5 Ed22005 Telecom Pulse Test Shielded I O Lines Level 2 tel C Programme Teseq AG WIN 3000 StandardTests IEC 61000 4 5 Ed22005 Telecom Pulse Test Shielded I_O Lines Level 1 tel Last used display of last four tests loaded 8 4 Sequence In this screen the predefined tests of various pulse modules can be combined to a single test sequence The sequencer also includes a dialog for production routines and standard tests Sequence View Dialogue New Load save a save As Edit description comment Delete Selected Last Used sequence menu T3SEO Advanced Test Solutions for EMC 48 8 4 1 New Click New to create a new sequence The sequence window is displayed This window can also be opened by double clicking to select a standard or user defined test in the test libaray window The sequence window is used to combine the predefined tests of various pulse modules into a single test It includes a dialog for production routines and standard tests Sequence File name C Programme Teseq AG WIN 3000 StandardTests IEC 61000 4 5 Ed2_2005 Combination Wave Test Unshielded Unsymmetrical IO Lines Level 1 cw C Programme Teseq AG WIN 3000 StandardTests IEC 61000 4 5 Ed2_2005 Combination Wave Test Unshielded Unsymmetrical IO Li
7. 12 The Microsoft Office Interop Word is used to guarantee a proper link between WIN 3000 and the Microsoft Word since the report will be generated in a Windows Word environment Following files need to be on the PC C WINDOWS assembly Microsoft Office Interop Word and C WINDOWS assembly Office If those files are not found then setup disk of Microsoft Office 2003 needs to be entered or in the files in the Officelnteropword folder on the WIN 3000 disc may be used If setup disk is not available Microsoft Office Interop Word can be downloaded with the following link http www microsoft com downloads details aspx familyid 3c9a983a ac14 4125 8ba0 d36d67e0t4ad amp displaylang en To install the Office 2003 Primary Interop Assemblies go along of the follow ing methods Double click the O2003PIA msi file Expand the application specific Microsoft Office Word 2003 PIA Expand the Microsoft Office Word node and select NET Programmability Support B Click the drop down arrow next to NET Programmability Support to select update options and choose Run from My Computer B Click Update 3 3 Modifying the Office 2003 setup using setup disc In the Maintenance Mode Options screen of the Microsoft Office 2003 Setup dialog box Select Add or Remove Features as shown in figure next and B Click Next WIN 3000 Remote control software if Microsoft Office 2003 Setup mI 13 Microsoft Office Professiona
8. 3000 includes a library of predefined IEC and ANSI tests in order to simply Standards testing The following screens show several test library examples Sy Phe Poner 5 Q3 EC amp T00C A Edi 2 90 AC Powar Line L3 1 Phirar y Phe Poser Line 1 04 Major Feeder ne Ec Level 1 Lii 2 76 B Leve bea Level dew 1 Pome Linn 1 44 ufi Line LBA Bi Level dew Level d S T Poser Linee LAE opor Feeder Line 120hm Level Lew Test library examples The library comprises 217 tests in 54 folders Additional standards tests will be added as they become available or upon customer request The test library can be easily updated through Windows Explorer T3SEO Advanced Test Solutions for EMC 22 4 3 10 Test step A single multi step test can contain up to 500 single steps and each test step can contain one or more ramping parameters Parameters can be changed in the test steps window M Seed wot 1 1 BY Poe E Pes irii 3 Na zn Burst Output 4 z v z WI Pos kHz 3 75 Soke 300 ms los Burst Curtput 5 200 000 V z00 Pos LEDO 3 hin Q 158 3hnc Dis 300 ma Ios Burst 1 Pos Spes 10 See Ln 1 150 mi 25 msn POE 7 Ej Pos kHz 3 Na isg ihn 1907150 ms 25 msbin 105 TEE L1 M E ADMI V DO VI Pes 1 0 350
9. Selecting Run from My Computer will install NET Programmability Support on your hard disk Selecting Run all from My Computer will install the currently selected feature and all of its subfea tures on your hard disk Since NET Programmability Support has no subfeatures selecting Run from My Computer and Run all from My Computer give the same results Select ing Installed on First Use will install the NET Programmability Support feature on your hard disk when you it for the first time In this case you may need access to the compact disk or network server you used to install Office 2003 in order to install the NET Programmability Support feature Click Update 3 3 1 Checking for files To check if the features have been properly installed search for the following files C WINDOWS assembly Microsoft Office Interop Word and C WINDOWS assembly Office WIN 3000 Remote control software 4 INSTALLATION WIN 3000 comes on a CD included in each NSG package or can be down loaded from the Teseg web site Insert the CD and double click on setup exe and follow the instructions on the screen 4 1 Firmware and hardware compatibility check Consult first the document Software Version History Vx yz to verify which FW ans SUI version you may need to install for a proper function of the generator WIN 3000 requires always the corresponding FW and SUI software The proper FW and SUI software are on the WIN 3000 installation dis
10. and must not be in the vicinity of the test setup while it is in operation The user must observe all safety instructions provided with the options accessories and auxiliary equipment used in the test setup The user must observe all warnings and cautions and must follow the installation instructions provided in the NSG user manual 5 1 NSG Ethernet address Before establishing communications with the NSG first check the generator s Ethernet address setting This setting is displayed in the Communication screen under System The Ethernet address can be entered for a specific connection to a PC or the NSG can be integrated into a LAN environment The default Ethernet address for the NSG 3040 is 10 10 10 10 T3SEO Advanced Test Solutions for EMC 23 24 5 1 1 IP address An IP Internet Protocol address is a unique address that electronic devices use in order to identify and communicate with each other on a computer net work utilizing the Internet Protocol IP standard Any participating network de vices including routers switches computers time servers printers internet fax machines and some telephones can have their own unique address 5 1 2 Subnet A subnet mask defines the IP range of a network For example if a network has a base IP address of 192 168 0 0 and has a subnet mask of 255 255 255 0 then any data going to an IP address outside of 192 168 0 X will be sent to that network s gateway A subnet m
11. changes and close the window Click the Cancel button to close the window without saving changes 8 2 7 Language Oenglih License Japanese Language selection box in settings menu Click Settings Language to set the WIN 3000 language Click to select English or Japanese additional language support is planned Note Changing the language setting will cause WIN 3000 to restart T3SEO Advanced Test Solutions for EMC 44 8 2 8 License Settings License This version is licensed to 0344 0 0009 0000 FD02 2935 7CDA F34C NSG 3060 License window in settings menu Click Settings License to display and add license keys for each NSG genera tor To add a new license key click the Add button to display the window shown below Settings License New license window Type the new license key in the text box Click the OK button to save the license key and close the window Click the Cancel button to close the window without saving the license key WIN 3000 Remote control software 8 3 Test Note The Sequence and Dialog windows must be closed before opening any Test menu items Test Sequence View S Dial New Load dVe Save As Edit description comment Delete Selected Last Used Test menu 8 3 1 New Click New to create a new test 8 3 2 Load To load an existing test Click Load Windows Explorer opens and displays the Open window with
12. description Click the Comment field and type the comment Descriptions are also included on test reports The description text will also be shown on the test report Edit description comment prameter Test Library 3 3 Gp StandardTests 9 O ANSI C 62 45 2002 Description This Test contains one voltage level 61000 4 11 Ed2 2002 C 61000 4 12 2 2006 O 61000 4 29 2000 H 61000 4 4 Ed2 2004 5 IEC 61000 4 4 1995 1 Phase Power Lines L Lewel 1 eft zl Li 2 eft Comment This test should only be used fo the test with EFT Test for 1 phase power line up to 500V alternate polarity burst frequency 5 kHz coupling to all type FG 56544 zi Level 4 eft 3 Phase Power Lines Capacitive Coupling Clamp O Power Lines with Manual CDM 8 61000 4 5 Ed2 2005 61000 4 8 Ed 1 1 2001 i 61000 4 9 Ed1 1 2001 EK Desktop ini Edit description comment window Windows Explorer The Comment field is used for additional text such as EUT specific charac teristics which must be taken into account during testing additional measuring equipment or other utilities This text is not printed on test reports T3SEO Advanced Test Solutions for EMC 49 50 8 4 6 Delete selected To delete a user test Click to select the test to be deleted The test file name is highlighted in blue
13. example if the NSG s IP address is the default setting 10 10 10 10 then the PC s IP address could be set to 10 10 10 12 To check and set the PC s addressing mode 1 Open START Settings Control in the Network connection menu Click the LAN connection icon WIN 3000 Remote control software 29 Network connection menu 2 Click Internet Protocol TCP IP gt marked in blue Click Properties Click the Allocate IP Address Automatically button for dynamic address assignment Network connection submenus 6 2 NSG 3000 addressing The IP address can be changed in the NSG user interface by entering SYSTEM SETTING COMMUNICATION The default IP address set in the NSG 3000 family system is 10 10 10 10 A fixed address must be assigned by the system administrator if the NSG sys tem is to be operated in a LAN environment The IP address of the NSG can be changed in local mode via user interface T3SEO Advanced Test Solutions for EMC 30 7 STARTING WIN 3000 mmm Make sure the user screen on the NSG Is in Remote mode by pressing the PC symbol in the main screen The last setting mode remote or local mode Will be saved on NSG and PC shut down Once the setup is complete the NSG Will save the configuration and always start in Remote mode The NSG can be operated in local mode by pressing the Exit button Upon startup WIN 3000 displays the following window _
14. the contents of the user tests folder Test filenames have different extensions indicating the test type Test Pulse module Ending Test Pulse module Ending Combination wave Electrical fast transient Telecom pulse 10 700 Variation Test Pulsed magnetic field Power magnetic field Test filename extensions T3SEO Advanced Test Solutions for EMC 45 46 8 3 3 Save Click Save to save changes to an existing test 8 3 4 Save Click Save As to save a new test or to save an existing test to a different filename or folder Windows Explorer opens and displays the Save As window with the contents of the User Tests folder 8 3 5 Edit description comment The Edit description comment function allows the user to add a detailed test description and or comment which will appear when the mouse pointer remains on a filename in Windows Explorer for more than 2 seconds This is useful in applications that include many similar tests that cannot be easily described and differentiated using filenames To add a description or comment to a test Click Edit description comment The Edit description comment window is displayed Click the Description field and type the description Click the Comment field and type the comment Descriptions are also included on test reports Test Library 5 8 StandardTests ANSI C 62 45 2002 Edit description comment Description This Test contains one voltag
15. Click the parameter box and drag it to the desired position To change a parameter start value Click the green arrow to reduce the start value or click the red arrow to increase the start value T3SEO Advanced Test Solutions for EMC 64 11 SELECTING TEST STEPS Ms 11 1 Run all When the RUN button is clicked WIN 3000 will execute every step in the test steps list that has a check mark in the select checkbox To run all test steps Click to check the select checkbox for each test step 11 2 Run selected only To run selected test steps Click to uncheck the select checkbox for each test step to be omitted Polarity Frequenc 2 300 500 5 3 1000 400 Alt 10 100 Select checkbox in test steps window 11 3 Run single test step or run from here To run a single step Right click the step The menu shown in following figure Click Run Single Step WIN 3000 Remote control software Test Steps 65 Select Volt 1 2 2 3 Polarity Frequency Run Single Step Run from Here Run single step example To run all check test steps from any point in the test step list Right click the step Click Run from Here 11 4 Run step by step To pause a test after each step Click to check the Run Step by Step checkbox at the bottom left corner of the workspace Polarity Frequency Phase Total Test Step Total Test Time Test Duration Count gt
16. FAIL IEC EN61000 4 4 IEC EN61000 4 5 3 IEC EN61000 4 11 4 T3SEO Advanced Test Solutions for EMC 37 40 Description of the criteria temporary loss of function or temporary degradation of performance not requiring an operator temporary loss of function or temporary degradation of performance requiring aoperator loss of function with permanent damge to equipment which means failing the test Tested by Name Title Equipment information Main equipment wem SS wema ow Equipment Table Manual or additional equipment Manufacturer Type Serial Nr Version FW Calibra Certificat tion date Nr CDN 163 d Cd m LL Bw WIN 3000 Remote control software Settings 41 EUT supply voltage Uin used for 10096 reference value Measured EUT Supply Voltage Measured EUT Supply Frequency EUT Power Status on EUT Fall Test Action on EUT Fail EUT Power Status on Interlock Descriptions or Explanation Environmental Conditions Test Results T3SEO Advanced Test Solutions for EMC 42 8 2 5 Monitoring Settings Monitoring EUT Supply Voltage NA V EUT Supply Frequency NA Hz EUT Power on EUT Fail Oon Goff Test Action on EUT Fail Input Stop OPause Continue EUT Power on Program Quit On caesi Monitoring window in settings
17. Run Ste Ste m p by Step LI Run Step by Step button This option automatically puts the test in Pause mode after each step is run so that measurements or other actions can be taken before resuming the test To resume testing Click the Play button T3SEO Advanced Test Solutions for EMC 66 12 RUNTIME DISPLAY W N3000 displays the Runtime window when a test is running This window has large text and can be expanded so that it is visible from a distance This allows the user to view test details during long or complex test sequences when the user cannot remain in front of the monitor To display a parameter in the runtime display window Click the parameter title on the header bar in the test step window Runtime Display di Runtime X gt Step priui Coupling 10 Burst Output Step Duration Coupling 10 Burst Output Example runtime display when step duration parameter is selected WIN 3000 Remote control software 67 12 1 Run time display and EUT fail connection The Runtime display window turns red to alert the user when an EUT fault input is generated during testing MJ C Programme Teseq AG Screen User test Function test eft WIN 3000 File Settings Test Sequence View Dialogue Help ALS Y AA Knew ac Cad MEE We as MAD Burst Electrical Fast Transient
18. September 24 2009 at 19 09 14 will have the filename COMM 09 09 24 19 09 14106 8 7 3 About The About menu item provides a Readme file with general WIN3000 information the software version and license number and a list of Teseq worldwide offices To access the About window click About in the help window T3SEO Advanced Test Solutions for EMC About WIN 3000 Distributors Standards Database For your convenience Win3000 allows updates and changes may be downloaded from the Internet Please contact your local sales z representative for extensions or upgrades Please report additions and Advanced Test Solutions for EMC corrections to info teseq com We realize that users auditors and committees do not always agree on the interpretation of the standards and so the standards data base is subject to change without notice r This software drives the NSG 3000 family with its automated accessories from Teseq remotely EEE More information on http www teseq com Teseq provides no warranties express or implied and specifically disclaims any warranty of merchantability or fitness for a particular purpose of this software and documentation Teseq will not be liable for damages resulting from loss of data profits use of products or incidental or consequential damages even if advised of the possibility thereof Installation and or use of this program constitutes acceptance of these terms and restrictions by th
19. T Power on Interlock Gon OOff External Test Control Pause On Off Next Step Test Stop Any Key on Keyboard General window in settings menu Beep during surge testing Click Yes to set the system to beep when a surge pulse is produced Click No for no beep Test Voltage Uin 96 Enter the 10096 reference value required for the PQT application in the box 230 in the example The user must measure and enter the EUT voltage input to the NSG EUT power on Interlock Click On for EUT power to remain on after the interlock is activated Click Off for the EUT power to be turned off after the interlock is activated External test control If the NSG is used in a production setting an external signal may be used to control the NSG between steps system connector on the rear of the NSG Click Pause On Off to put the NSG is Pause mode following each test step Click Next Step for the NSG to proceed automatically to the next test step The External Test Control setting does not matter if no external signal is present T3SEO Advanced Test Solutions for EMC 36 Test stop NSG tests are typically stopped by clicking the STOP button atthe bottom of the WIN 3000 main menu For additional safety click to check the Any key on keyboard box This feature will allow the user to stop a test by pressing any key on the PC keyboard If the box is left unchecked tests can be stopped only with the STOP button Click the OK button to
20. T3SEO Advanced Test Solutions for EMC 58 E Hog WW E Docking symbols When a window is being dragged the docking symbols shown below will display on the workspace The docking symbols can be used to correctly align the window within the workspace To use the docking symbols while dragging the window Position the cursor over one of the symbols The workspace area where the window will be docked turns light blue Release the mouse button to dock the window to the selected area SEO E Settings Test Sequence View Dialogue Fsirsirelrzirissit i jle iiel 9 n aimi ape J En T 4 1 Too Fe ot oe L AL i i Q T m Docking symbols docking area examples 9 1 Pin Unpin windows Individual windows in the workspace can be pinned and unpinned To unpin a window WIN 3000 Remote control software Click the pin icon at the top right of the window 59 The window will be displayed as a tag on the left or right side of the work space I a Pin icon Position the mouse pointer over the tab to display the pinned widow The pin icon is displayed sideways Sideways pin icon To re pin a window Click the sideways pin icon The window is displayed in its default place in the workspace Each window has a drop down menu which can be used to make the window floating or dockable and to hide or a
21. a crossover cable which must be double shielded to protect both the master controller and PC from EMC dis turbances CAUTION The PC must be equipped with a 10 Mbit s port If the PC Ethernet interface is specified only for 100 Mbit s then either a 10 100 hub or a switch hub between the PC and the NSG is required It is also possible to use an USB Ethernet adapter Teseq recommends the LevelOne USB 0201 Two pairs crossed two pairs uncrossed 10 BaseT 100 BaseTX crossover RJ 45 Connection 1 Connection 2 Pin 1 RX Pin TX Pin 2 RC Pin 6 Tx Pin 3 TX Pin 1 RC Pin 6 TX Pin 2 RC 6 1 1 Ethernet crossover cable color code T3SEO Advanced Test Solutions for EMC 28 Two pairs crossed two pairs uncrossed 10 BaseT 100 BaseTX crossover RJ 45 Crossover cable color codes Connection 1 color whites green stripe green solid whiter orange stripe orange solid whiter brown stripe brown solid Connection 2 color white orange stripe orange solid white green stripe green solid white brown stripe brown solid 6 1 2 Peer to peer PC setting The PC must be set up for a peer to peer connection in order to use a direct link PCs are typically connected into a LAN environment in which the IP address Is provided by the server With a peer to peer connection the PC s IP address must be set manually The IP address of both the NSG and the PC must be in the same Subnet range For
22. al Click to check to Signal on Appearance checkbox to have the system emit a beep whenever the dialog box is displayed Delay To program an automatic delay in the test sequence when a dialog box is dis played Click to select the Delay checkbox and type the delay time in seconds in the text box Delay time can range from 1 second to 999 seconds Uin The Uin value setting is used only when a VAR 3005 D16 automated double variac is included in the test setup To set input voltage when a dialog box is displayed Click to check the Uin checkbox and type the input voltage value in the text DOX Uin value is set to the start level nm WARNING It is the user s responsibility to be sure the Dialog box example The following example show a completed dialog The red slider bar measures the elapsed delay time T3SEO Advanced Test Solutions for EMC 53 C Programme Teseq AG WIN 3000 UserT Appearance This filed can be used for free text Title This is TEST Dialogue his filed can be used for free text Picture _ Additional information can be added Description v Continue Button Button v Repeat Button Options z Signal on Appearance Delay 5 juin V Example of dialog box window and the resulting dialog box 8 6 2 Load To load an existing dialog box click to select Load from the Dialog box menu Windows Explorer displays
23. are gt CAUTION WIN 3000 is designed for use on a single host PC and should not be used in a networked environment T3SEO Advanced Test Solutions for EMC 10 Q 3 SOFTWARE REQUIREMENTS CAUTION Before WIN 3000 can be installed following gt software add on are mandatory to run the WIN 3000 on the desired PC platform Microsoft DotNetFramwork3 5 Microsoft Office interop Word 3 1 Microsoft DotNetFramwork WIN 3000 is written in C is mainly platform and processor independent and uses the Framework for conversion to the Windows operating system In case this add on can t be found a version it s included on the disc or dotNetPx35 can be download free of charge from the Microsoft homepage 3 1 1 What is NET Framework Because interaction between new and older applications is commonly required the NET Framework provides means to access functionality that is implemented In programs that execute outside the NET environment The design of the NET Framework allows it to theoretically be platform agnostic and thus cross platform compatible That is a program written to use the frame work should run without change on any type of system for which the framework is implemented While Microsoft has never implemented the full framework on any system except Microsoft Windows the framework is engineered to be platform agnostic and crossplatform implementations are available for other operating syst
24. ask is a method of hiding or masking the network address por tion of an IP address It does so by assigning a value of 1 to every digit in the network address portion of the binary IP address These masked digits are not permitted to change when assigning IP addresses to local host or machines on the local network An open address could therefore be 255 000 000 000 5 1 3 Gateway A gateway is a network point that acts as an entrance to another network On the internet a node or stopping point can be either a gateway node or a host endpoint node Both the computers of individual internet users and servers are host nodes The computers that control traffic within a company network or at an Internet Service Provider ISP are gateway nodes In an enterprise network a computer server acting as a gateway node also often acts as a proxy and a fire wall server A gateway is often associated with both a router which knows where to direct a given package of data that arrives at the gateway and a switch which delivers the actual path in and out of the gateway for a given package The gateway address is usually set to 0 0 0 0 WIN 3000 Remote control software 5 1 4 Port The port address allows a network device to communicate between hosts on both private and public networks It allows a single public IP address to be used by many hosts on a Local Area Network LAN The port address for the NSG 3000 is set to 1025 5 1 5 Mac address I
25. can set parameter values ramping and units Burst Electrical Fast Transient Alt Burst Volt 200 V Output Frequency 5 Burst Time 75 Spikes Repetition Time 300 ms Step Duration 1205 200 V Bua Impedance 20 ee 60s i Pulsed Magnetic Field EE U 57 A m Impedance 20 o 60 s Phase p ion 10 Pulses Pulse parameter window for different test types T3SEO Advanced Test Solutions for EMC 19 20 4 3 6 Graphical information WIN 3000 graphical information can be useful in preventing misunderstandings concerning test parameter definitions These graphs can be easily attached to test reports Graphic Burst Electrical Fast Transient U Burst packets Burst 15ms 5KHz Time 0 75ms 100KHz Repetition Time Examples of graphical information for Burst EFT and voltage variation tests 4 3 7 Parameter flow The Parameter Flow screen 15 used to prioritize ramped parameters The user can drag and drop parameter boxes to place them in the appropriate sequence Parameter start values can be set by clicking the up and down arrows in each parameter box 123 al Parameter flow screen WIN 3000 Remote control software 4 3 8 Sequencer 21 The sequencer screen is used to combine predefined tests into a single test sequence This screen includes a dialog for production routines and standard tests 4 3 9 Test library WIN
26. ce Teseq Sarl T 33 139 47 42 21 F 33 1 39 47 40 92 francesales teseq com Japan Teseq K K T 4813 5725 9460 813 5725 9461 japansales Qt eseq com Switzerland Teseq AG T 41 32 681 40 50 F 41 32 681 40 48 sales Qteseq com UK Teseq Ltd T 44 845 074 0660 F 44 845 074 0656 uksales teseq com January 2011 Teseq Specifications subject to change without notice Teseg is an ISO registered company Its products are designed and manufactured under the strict quality and environmental requirements of the ISO 9001 This document has been carefully checked However Teseq does not assume any liability for errors or inaccuracies
27. ck Connect to initiate a connection to selected IP The connection icon turns green when a connection is successfully estab lished eset When a connection is complete WIN 3000 displays the parameter setting window for one of the test modules installed in the NSG T3SEO Advanced Test Solutions for EMC 34 8 MENU BAR DESCRIPTION The menu bar of the WIN 3000 main menu provides access to all the features and functions of the WIN 3000 software The menu bar comprises seven menus and their submenus as shown below File Settings Test Sequence View Dialogue Help 8 1 File File Settings Exit Online Click File Exit to close the WIN 3000 application Click File and click to check Online to open communications with the NSG Click File and click to uncheck Online to close communications with the NSG 8 2 Setting Settings Test S General Equipment Report Test Library Monitoring Communication Language License Settings menu The Settings menu allows the user to view define and access WIN 3000 features and functions including general test control settings a list of NSG equipment WIN 3000 Remote control software modules report creation and editing test library access test monitoring param 35 eters network settings program language and license information 8 2 1 General Settings General Beep during Surge Testing Yes No Test Voltage Uin 230 EU
28. e CAUTION Do not confuse this connection with the EUT power input T3SEO Advanced Test Solutions for EMC 8 2 INTRODUCTION ENNEN2 1 General description WIN 3000 remote software is a comprehensive program designed to create test libraries for the surge burst PQT and magnetic field tests that can be performed with Teseq s NSG 3000 generator series and its accessories The software allows users to create single test files of up to 500 steps and to combine multiple tests into unique sequences WIN 3000 includes a Word based standard test report which can be easily modified to suit individual user requirements 2 2 PC hardware requirement The following hardware is required to run WIN 3000 IBM compatible PC 00 MHz Pentium processor or equivalent minimum 1 GHz Pentium processor or equivalent recommended with 586 processor or higher Operating systems Windows Server 2003 Windows Server 2008 Windows Vista Windows XP SP2 Windows 7 32 bit Additional software Word 2003 or higher Word for Vista or Windows 7 RAM 256 MB minimum 500 MB recommended Hard disk Up to 500 MB of available space incl 100 Mb of free space may be required Other hardware Keyboard mouse CD or DVD drive network card with RJ 45connector twisted pair min 10 MBit USB connector if an adapter is used Display 800 x 600 256 colors minimum 1024 x 768 high color 32 bit recommended WIN 3000 Remote control softw
29. e Ethernet crossover cable color code Peer to peer PC setting NSG 3000 addressing Starting WIN 3000 Edit button Add and delete button Automatic connect Offline retry and connect Menu bar description File Settings General Equipment Report Editing and customizing test report templates Monitoring Communication Language License Test New Load Save Save as Edit description comment Delete selected Last used Sequence New Load WIN 3000 Remote control software 24 24 24 25 25 26 27 27 28 29 30 31 32 32 33 34 34 34 36 36 97 42 43 43 44 45 45 45 46 46 46 47 47 47 48 48 8 4 3 8 4 4 8 4 5 8 4 6 8 4 8 5 8 5 1 9 5 2 8 5 0 8 0 4 8 6 8 6 1 8 6 2 8 6 3 8 6 4 8 6 5 8 7 Du 9 9 9 1 10 10 1 10 2 10 2 1 10 2 2 10 3 10 4 11 11 1 11 2 11 9 11 4 12 12 1 13 Save Save as Edit description comment Delete selected Last used View Windows Default workspace Save workspace Restore workspace Dialog New Load Save Save as Last used Help Documentation RXTX Log About Resizing and rearranging windows Pin unpin windows Writing test steps and changing parameters Changing parameter values Add new test steps Copy Delete Changing step order Changing parameter flow order Selecting test steps Run all Run selected only Run single test step or run from here Run step by step Runtime display Run time di
30. e amm Sep by Step C Volt parameter editing window 10 2 Add new test steps To add a new test step Right click a test step A dialog box with two options Copy and Delete are displayed 10 2 1 Copy Select Copy to copy the selected test step The step is added to the bottom of the list 10 2 2 Delete Select Delete to delete the selected test step Run Single Step Run from Here Dragging test step to change order T3SEO Advanced Test Solutions for EMC 62 10 3 Changing step order To change the step order click to select the step The selected step is highlighted in blue Drag the step to the desired position in the test step list Test Steps Select Volt Polarity Frequency Phase 1 200 i 300 500 1000 4000 Alt 10 100 Dragging test step to change order 10 4 Changing parameter flow order The parameter flow window shows the priority of each ramped parameter in atesi 200 ms Burst Time 75 Spikes t i Frequency 10kHz F al Parameter flow window WIN 3000 Remote control software The order of priority for parameter change is from top to bottom In the above 63 example the two ramped parameters are voltage and frequency volt val ues are ramped at a frequency of 10 kHz before the frequency parameter is ramped to the next level To change the priority of a parameter
31. e level 61000 4 11 Ed2 2002 61000 4 12 Ed2 2006 O 61000 4 29 2000 8 61000 4 4 Ed2 2004 IEC 61000 4 4 1995 1 Phase Power Lines ci Level 1 eft m E m Li 2 eft Comment This test should only be used fo the test with EFT Test for 1 phase power line up to 500V alternate polarity burst frequency 5 kHz coupling to all type FG 56544 zi Level 4 eft i 3 Phase Power Lines Capacitive Coupling Clamp 61000 4 5 Ed2 2005 8 61000 4 8 Ed 1 1 2001 61000 4 9 Ed1 1 2001 O User Test Edit description comment window Mouse over description example in Windows Explorer WIN 3000 Remote control software The Comment field is used for additional text such as EUT specific charac 47 teristics which must be taken into account during testing additional measuring equipment or other utilities This text is not printed on test reports 8 3 6 Delete selected To delete a user test Click to select the test to be deleted The test file name is highlighted in blue Click Delete selected Note Standard tests cannot be deleted 8 3 7 Last used To load the last test used Click Last used The last four tests loaded are displayed Click to load the selected test Last Used C Programme Teseq AG WIN 3000 StandardTests IEC 61000 4 5 Ed22005 Telecom Pulse Test Shielded I_O Lines Level 4 tel s En C
32. e user Teseq offices Germany Headquarters Teseq GmbH Teseg AG Landsberger Strasse 255 Nordstrasse 11F 12623 Berlin Germany 4542 Luterbach Switzerland T 49 30 5659 8835 T 41 32 681 40 40 F 49 30 5659 8834 F 41 32 681 40 48 desales teseq com info teseq com www teseq de www teseq com China UK Teseq Company Limited Ltd Room 1001 5 Ashville Way Sky Plaza Molly Millars Lane No 46 Dongzhimenwai Dajie Wokingham Dong Cheng District Berkshire RG41 2PL UK 100027 Beijing China T 44 845 074 0660 T 86 10 8460 8080 F 44 845 074 0656 About window information WIN 3000 Remote control software 9 RESIZING AND REARRANGING THE 57 WINDOWS EE The WIN 3000 workspace has been designed for maximum flexibility and cus tomization All windows can be resized or rearranged in different locations within the workspace To resize a window Click the window The window frame turns red Move the mouse cursor to the border of the window The cursor changes to a double arrow Click and drag the window to increase decrease the size Graphic Burst Electrical Fast Transi Burst packe Burst 15ms 5KHz Time 0 75ms 100KHz Repetition Time Window with cursor arrow for resizing To move a window Click the window The window frame turns red Move the mouse cursor to the bar at the top of the window Click the bar Holding the mouse button drag the window to another part of the workspace
33. ems Microsoft submits the specifications for the Common Language Infrastruc ture which includes the core class libraries Common Type System and the WIN 3000 Remote control software Common Intermediate Language This makes it possible for third parties to 11 create compatible implementations of the framework and its languages on other platforms CAUTION Applications running in a managed envi ronment tend to require more system resources than similar applications that access machine resources more directly Therefore startup procedure will take more time since the conversion will be done each time Using the NET Framework ensures software compatibility with future versions of Windows and will also ensure compatibility in a 64 bit environment as soon as NET Framework is able to run on a higher bit rate The NET Framework version 3 5 This version is available on the WIN 3000 CD and can also be downloaded on http www microsoft com downloads or for direct link http www microsoft com downloads details aspx FamilyID2d0e5dea7 ac26 4ad7 b68c fe5076bba986 amp displaylang en 3 2 Microsoft office Interop Word CAUTION If WIN 3000 starts and then suddenly shuts down with error messages it is usually because the feature Microsoft Office Interop Word is missing on the host PC This feature is necessary to ensure a proper link between WIN 3000 and Microsoft Word T3SEO Advanced Test Solutions for EMC
34. k or can be down loaded from the Teseq website 4 2 Light version vs fully licensed version When WIN 3000 is installed a counter will start automatically to allow the user to run a full version of the software for 30 days After 30 days the user must either purchase a license key code to use the full version or continue to use a light version of WIN 3000 With the light version WIN 3000 can still be used to create save and load test steps however test sequencing reporting capability and the test library are not available In order to purchase a full version of WIN 3000 contact your local customer service center and provide the series number of your master controller units which are displayed in the Equipment window of the NSG user interface T3SEO Advanced Test Solutions for EMC 16 Equepment data SUL 3000 09001 0604 NA HMODMC HL D001 23A 357 345 2007 34 520807 HV5 amp 601 0001 190 iio 1 12003 1 1 2003 EFT amp amp DI 0001 14 14 1 1 2043 1 1 2003 REWE amp LDI 2001 146 35 1 1 2000 1 1 2003 Equipment window in NSG 3000 series user interface Module Type MODMC MU Please make sure you provide the correct series number since the license key Is related to your unique master controller serial number It is possible to add multiple license codes if you are using the software with multiple generators 4 3 Windows description The following icon is displayed on the desktop following insta
35. l Edition 2003 Mair enance Mode Options Oa F gU d Add or Remove Features 9 Change which Features are ins rena Reinstall or Repair 1 M Reinstall or Repair Microsoft Office 2003 to its original state Ca Uninstall x Uninstall Microsoft Office 2003 From this computer Microsoft Office 2003 Setup screen m Select Choose advanced customization of applications and Click Next Expand the application specific Microsoft Office Word 2003 PIA Expand the Microsoft Office Word node and select NET Program mability Support B Click the drop down arrow next to NET Programmability Support to select update options and Choose Run from My Computer as shown in figure below CAUTION Do not choose Installed on First Use T3SEO Advanced Test Solutions for EMC 3 Microsoft Office 2003 Setup Microsoft Office Professional Edition 2003 Advanced Customization Choose update options for applications and tools E Microsoft Office LJ Microsoft Office Access Microsoft Office Word Microsoft office SJ Run from My Computer 2 Run from My Computer 3 Installed on First Use X Not Available Description Primary interop assembly that allows Microsoft Office Excel programmabilty wth NET Framework version 1 1 Space Required on C 1908 KB Space Available on C 3132 MB Tom Office setup advanced customization screen Note
36. llation WIN CODO nl Click the icon to display the following window WIN 3000 Remote control software peo p og 2 10 Header bar Menu bar File shortcuts Test icons Test parameters Graphical information Parameter flow window Test libary window Dialog window Run time windows unpinned mode 11 Start Pause Stop buttons 12 19 14 Control shortcut buttons Test step window Connection status T3SEO Advanced Test Solutions for EMC 18 4 3 1 Header bar The header bar displays the program name and the buttons to minimize or reduce the screen and close the application le Ea If a test is loaded then the header bar displays the test file name and path Ee EIE UEM EET UE Power Lines Lewel Left WIN TSSEQ ug 4 3 2 Menu bar File Settings Test Sequence View Dialogue Help The menu bar contains buttons to access all WIN 3000 features 4 3 3 Files shortcuts All main commands are quickly accessible the following icons A description of each command is displayed when the mouse is moved over the icon erreurs Test sequence Dialog 4 3 4 Pulse selection Active and or available pulse modules are displayed in red Inactive and or unavailable pulse modules are displayed in gray WIN 3000 Remote control software 4 3 5 Pulse parameter window The pulse parameter window varies depending on the pulse selected In this window the user
37. menu Click Settings Monitoring to view actual EUT supply voltage and frequency and to control the EUT EUT Supply Voltage EUT Supply Frequency These boxes display the actual EUT supply voltage NSG 3060 only and EUT supply frequency as provided by the NSG Power on EUT Fail using system connector on the rear of the NSG Click to select ON to keep EUT power on if the EUT fails Click to select OFF to turn EUT power off if the EUT fails Test Action on EUT Fail Input using system connector on the rear of the NSG Click to select Stop to stop the test after EUT Fail is detected Click to select Pause to pause the test after EUT Fail is detected Click to select Continue to continue testing after EUT Fail is detected EUT Power on Program Quit Click to select On to keep EUT power on after the program has stopped Click to select Off to turn EUT power off after the program has stopped Click the OK button to save changes and close the window Click the Cancel button to close the window without saving changes WIN 3000 Remote control software 8 2 6 Communication 43 Bir Settings Communication Port 1025 Gateway 172 20 0 1 MAC Address Cancel OK Communication window in settings menu H i Click Settings Communication to view or change the NSG communication parameters Note If the IP address is changed the connection to the NSG will be lost Click the OK button to save
38. n computer networking a Media Access Control MAC address is a quasi unique identifier attached to most Network Interface Cards NICS It is a num ber that acts like a name for a particular network adapter The MAC address cannot be changed T3SEO Advanced Test Solutions for EMC Zo 26 6 CONNECTION TO AN NSG 3000 FAMILY GENERATOR SYSTEM All NSG generators are equipped with a 10 Mbit s Ethernet interface The con nector is on the master controller plug on the rear panel of the generator The WIN 3000 software package includes a shielded STP CAT5 cable The shield is important for a safe test setup in an EMC environment BERE HER I EEEIEE E UC RH 8 d EHUSFEBHUNTCEEHSTERENHSATFEENSUTEENNHZAEEEHHU EERHUEERSSTERNZUEERSUTERHESTERESNTERENEUTERSEUTERN RJ 45 Ethernet connector NSG 3000 Ethernet connector The generator can be connected to any 10 Mbit s Ethernet port using a stan dard 10BaseT or 100BaseT RJ 45 cable when it is operated in a networked environment The NSG can be accessed by any PC within the network that has WIN 3000 software installed on it A connection can also be established via router on the LAN There are two main connection options Peer to peer and LAN WIN 3000 Remote control software 6 1 Peer to peer connection using a crossover cable 27 A peer to peer connection is a direct link from the PC to the NSG with no LAN interface This connection requires
39. nes Level 2 cw C Programme Teseq AG WIN 3000 StandardTests IEC 61000 4 5 Ed2_2005 Combination Wave Test Unshielded Unsymmetrical IO Lines Level 4 cw Sequence window test steps are checked Only checked test steps will be When selecting a multi step test be sure that all required executed in the sequence 8 4 2 Load To load a sequence Click Load Windows Explorer displays the Open window with the contents of the User Tests folder Click to select a sequence file All sequence files have the file extension seq 8 4 3 Save To save an existing sequence Click Save The updated sequence is saved to its original filename and location WIN 3000 Remote control software 8 4 4 Save as TO save a new sequence Click Save As Windows Explorer displays the Save As window with the contents of the user tests folder Type the file name and click Save 8 4 5 Edit description comment The Edit description comment function allows the user to add a detailed descrip tion and or comment which will appear when the mouse pointer remains on a filename in Windows Explorer for more than 2 seconds This is useful in applica tions that include many similar test sequences that cannot be easily described and differentiated using filenames To add a description or comment to a sequence Click Edit description comment The Edit description comment window is displayed Click the Description field and type the
40. o select On Request to create a test report on demand using the short cuticon in the WIN 3000 main window Note Once a testis complete it is no longer possible to create a report Select ing automatic report generation is the only way to ensure that all test data is included in the report Report template Click the box to browse and select report templates WIN 3000 includes a report template named Template en dot or dotx The user can either edit this template or create a new template to create a customized report EUT fail signal graphic pictures Click the EUT Fail Signal check box to include EUT fail information in the report The EUT Fail signal can be activated only via the system connector on the NSG rear panel Refer to the NSG manual for detailed information on this feature Click the Graphic Picture check box to include graphical information in the report Click the OK button to save changes and close the window Click the Cancel button to close the window without saving changes 8 2 4 Editing and customizing test report templates The template provided with WIN 3000 is an xxx dot file which can be edited in Word All templates must have the xxx dot file extension and be saved to the appropriate folder in WIN 3000 to be accessible All information in the basic report template can be changed or deleted to create a customized report The report template contains Word field codes or place holders for data fr
41. om the test file Place holders can be repositioned or deleted as required Press ALT F9 to view all place holders in the template Following place holders are available T3SEO Advanced Test Solutions for EMC 97 38 ALT F9 to view all place holders in the template Following place holders are available Place holder Description Template code name Date Actual date 24 09 2009 Time Actual time when test has 15 56 started Company name Will take the company namefrom TESEQ AG the installation setting Equipment Will take all information given in In report the equipment file Test type What kind of selected test are In report chosen Special setting Like Uin manual CDN IEEE Manual set EUT voltage Uin 230 V Measured EUT supply voltage NSG 3060 only voltage value at start Measured EUT supply fre NSG 3060 only frequency quency value at start Test parameter Test pareameter given from the test file Test duration Total test duration Setup picture Customized pictures Normal insert command Graph picture Integration of graphics shown in In report the software Report template place holders WIN 3000 Remote control software TEST REPORT Immunity to EMC Pulses Costumer Company name Street Town Tel Fax Mail Equipment tested Description Serial number HW Version FW Version SW Version Test specification Standard Level Result IEC EN61000 4 2 PASS of
42. riented duplex protocol that supports both reliable data streaming and partial reliable messaging UDT uses periodic acknowledgments ACK to confirm packet delivery while negative loss reports are used to report package loss Periodic help to reduce control traffic on the reverse path when the data transfer speed is high because in these situations the number of ACKS is proportional to time rather than the number of data packages If an IP address is not found a new IP address can be set manually by clicking Add To delete an IP address select it and click Delete For automatic searching via UDP Firewall needs to be switched off No generators found via UDP manual defined generators IP Address Port Name Description 10 10 10 12 1025 10 10 10 10 1025 172 20 32 222 1025 5 3040 EMC Test place Automatic Connect Connection window no generator found 7 3 Automatic connection Check the automatic connect box to select automatic connection for the se lected NSG The connection icon will switch from red to green during the con nection process Connection is established in approximately 5 seconds WIN 3000 Remote control software 7 4 Offline retry and connect 33 Click Offline to use WIN 3000 in offline mode without connection to a NSG All functions except the control buttons can be used in offline mode Click Retry to refresh a connection or start a new search Cli
43. save changes and close the window Click the Cancel button to close the window without saving changes 8 2 2 Equipment Modulename Text FW Version Serial No 1 Cal Date Last Cal Date Certificate No MCR3000 Master controller 1 52 96 06 01 2006 01 01 1970 Martin CDN 3041 C 1 Phase coupling decoupling network 4 4kV for EFT and Surge 0001 60 162 20 02 2009 11 02 2009 04101620209 PTQ 6501 Power quality module 0001 60 7 17 02 2004 17 02 2004 thomae HVM 3040 High voltage module 4 kV 0001 60 180 CWM 3450 Combination wave 4 4 kV 0001 60 172 22 02 2009 13 02 2009 45001720209 FTM 3425 Burst pulse 4 8 kV 0001 60 73 23 02 2009 14 02 2009 42500730209 Equipment window in settings menu Click Settings Equipment to access a list of NSG system modules with its FW version and calibration dates Click Copy to Clipboard to copy the equipment list into a text file or email Click Close to close the window 8 2 3 Report Start Report Automatically after Start On request Report Template C Programme Teseq AG Screen Templates Template_en dot EUT Fail Signal In Report Graphic Picture In Report Report window in settings menu WIN 3000 Remote control software Start report Click Settings Report to select report templates and control when reports are started Click to select Automatically after Start to start Word and create a test report automatically after a test is started Click t
44. splay and EUT fail connection Addresses 48 49 49 50 50 50 51 51 51 51 51 92 54 54 54 54 30 99 99 9o 97 58 60 60 61 61 61 62 62 64 64 64 64 66 6 68 T3SEO Advanced Test Solutions for EMC WARNING This software is designed to run with a Teseq NSG 3xxx series EMC test pulse generator and its acces sories EMC testing generates high voltages which can pose a lethal danger if proper safety procedures are not followed The system can also radiate illegal electro magnetic interference if it is used outside a properly equipped test laboratory The NSG system must only be used for EMC test purpo ses as directed in this manual and the NSG test genera tor user manual The user must observe all warnings and cautions pro vided in both this manual and the NSG test generator user manual WIN 3000 Remote control software 1 EXPLANATION OF WARNING AND CAUTION SYMBOLS EE Ihe information provided in the warnings and cautions in this manual must be Observed to ensure safety during equipment operation and to achieve optimal operating results The following symbol denotes a warning Failure to observe a warning can result in equipment damage personal injury or death Example WARNING Never connect or disconnect the EUT while the test system is performing a test The following symbol denotes a caution Failure to observe a caution can result in impaired system performance Exampl
45. the Open window with the contents of the User Tests folder Click to select the required file All dialog box files have the file extension xxx dig 8 6 3 Save To save changes to an existing dialog box file click to select Save from the dialog box menu 8 6 4 Save as To save a new dialog box or to save an existing dialog to a new filename click to select Save As from the Dialog box menu Windows Explorer displays the Save As window with the contents of the User Tests folder Type the new filename and click the Save button 8 6 5 Last used To load the last test used Click Last used The last four tests loaded are displayed Click to load the selected test WIN 3000 Remote control software 8 7 55 The help menu provides access to the WIN 3000 user manual the NSG log file and WIN 3000 version and licensing information Help Documentation RxTx Log About Help menu 8 7 1 Documentation The manual is included as well as the so called Handy guide Additional docu ments may be add later on Click Documentation to access the WIN3000 user manual and Handy guide 8 7 2 RXTX Log All commands to and from the NSG can be logged and stored in a file To activate the log file click to check RXTx Log v RXTx Log RXTX Log To deactivate the log file click to uncheck RXTx Log The log filename represents the date and time that the log file is activated For example a file activated on
46. uto hide the window When Hide is H id selected the window can be restored only by selecting View Windows Window status drop down menu T3SEO Advanced Test Solutions for EMC 60 10 WRITING TEST STEPS AND CHANGING PARAMETERS 10 1 Changing parameter values To select a pulse Click the icon associated with the test to be run EFT in the following ex amples WIN 3000 will display a single default test step 7 nol n x ne Volt Polarity Frequency Phase Burst Time Repetition Time Step Duration Coupling Status 200 Alt 5 75 300 20 Burst Oulput 300 500 4 Alt 5 Burst Output 1000 4000 Alt 10 100 Burst Output Tota Test Step Total Test Time Test Duration Count MA Apprax Test Time p i LT x 0d 8min 115 amp Run Step hy Step Test step window EFT Parameters can be changed in two ways 1 Click to select the test step The background turns blue and parameters for the selected test step are displayed in the parameter window Click to select a parameter A parameter editing window for the step is displayed 2 Click to select the test step The background turns blue Double click a parameter in the selected test step A parameter editing window for the step is displayed WIN 3000 Remote control software 61 Polarity Alt Y Selected Value 200 zl r 91 75 300 Total Test Step Total Test Time an
47. zed dialog boxes in which the user can include special instructions and comments Dialog boxes are programmed to display at certain points in a test sequence to prompt the user to perform special functions such as making specials measurements or changing EUT settings T3SEO Advanced Test Solutions for EMC 92 8 6 1 To create a new dialog box for a test sequence Click New in the Dialog menu The following window is displayed Appearance Title Message Picture Description L Continue Button Exit Button Repeat Button Options Signal on Appearance Dpeay s Dum 230 v New dialog window Title To enter a dialog box title click the box and type the title Message To enter a user message click the box and enter the message text Picture To include a picture in the dialog box click the box with the ellipsis Windows Explorer opens Description To enter a dialog box description click the box and type the description text Button selection Dialog boxes can require the user to take an action Actions include Continue the test sequence Exit the sequence or Repeat the test To insert a control button in the dialog box Click to check the required button Continue Exit or Repeat The dialog box can include one two or all three buttons WIN 3000 Remote control software Options The dialog box can be programmed to include several options Sign