Home
MidiMux Firmware User's Manual
Contents
1. The MidiMux is uploading firmware to an MPEG encoder connected to a TS input port This state is reported for a short time during powerup and after changing the TS input mode to MPEG Encoder Loading the FPGA failed This status probably indicates a hardware failure Please ask for support The TS input mode of TS input port x is set to encoder but a MPEG encoder was not detected or an error occurred while starting the encoder Please make sure that your encoder is connected properly or try a different encoder if you suspect a hardware problem The TS input mode of TS input port x is set to tuner but a tuner was not detected or an error occurred while configuring the tuner Please make sure that your tuner is connected properly or try a different tuner if you suspect a hardware problem The TS input mode is set to tuner a tuner was detected but is not locked to a signal Check if your tuner settings are correct and make sure that the tuner gets a good signal The MidiMux is working The MidiMux is in an unknown state This indicates a severe hardware or software error Power cycle your MidiMux and if the problem persists ask for support 6 MiniMod Remote Control The MidiMux is capable of controlling a MiniMod connected to the MidiMux TS output port This means that you are able to control all of the MiniMod s modulation settings from the MidiMux RS232 serial port or display keypad To make the MiniM
2. The TS output port is configured to accept a TS clock from an external device for TS data output generate clock kBit s The TS output port is configured to generate TS clock for TS data output The TS clock rate is set to transmit the specified amount of data Incompatible HW SW The device connected to the TS output port was recognized but its firmware is incompatible with the current MidiMux firmware Try to update both components to their latest firmware versions MiniMod V detected 4 9 MiniMod Status MiniMod ON AIR The MiniMod connected to the TS output port was recognized and can now be controlled from the MidiMux A MiniMod Settings menu appears and is be accessible from the MidiMux main menu The MidiMux output port and the MiniMod input port are automatically configured to ensure smooth data flow This status line shows the global status of the MiniMod connected to the MidiMux TS output port See the MiniMod Firmware Manual for a list of possible status messages and their descriptions 4 10 PSI Status Basic PSI Generator Active This line shows the status of the MidiMux built in table generator Status Display Description PSI Generator The MidiMux PSI Generator was disabled The MidiMux will not generate any disabled PSI or SI tables Basic PSI Generator The MidiMux Basic PSI Generator is active The MidiMux will generate PAT active SDT NIT and PMTs fo
3. Tables This menu item configures if the PSI Tables PIDs below 0x20 are forwarded to the multiplexer or blocked at the tuner input port Selected Value Description pass All PIDs from the tuner will be passed to the multiplexer block Only PIDs with values of 0x20 or above are passed to the multiplexer PSI tables which are on the PIDs below 0x20 are blocked 3 8 Tuner Settings DVB T These menu items are displayed when a DVB T NIM is attached to the MidiMux t FEC constellation setting and guard interval are automatically detected from the TPS bits embedded into the carrier Only frequency and bandwidth need to be set to receive a signal 3 8 1 Frequency Set the reception frequency for the DVB T tuner in kHz Valid values are between 145000 kHz and 858000 kHz The DVB T frequency refers to the center of the channel independently of the bandwidth 6s maintecn SR Systems 3 8 2 Bandwidth Set the reception bandwidth for the DVB T tuner in MHz Valid values are between 1 MHz and 8 MHz 3 9 Tuner Settings DVB S These menu items are displayed when a DVB S NIM is attached to the MidiMux 3 9 1 Frequency Set the reception frequency for the DVB S tuner in kHz Valid values are between 950000 kHz and 2150000 kHz tS The MidiMux does not account for the LOF of an LNB that you might use If you use an LNB to receive the DVB S signal you need to calculate the IF and set the frequency to that valu
4. audio is connected to the TS input port Possible values are 1 12 1 34 2 12 2 34 3 12 3 34 4 12 and 4 34 3 6 11 Audio Volume The Audio Volume menu item lets the user attenuate the received SDI audio signal before encoding It is only available when a SDI input module with support for embedded audio is connected to the TS input port Possible values are in the range 0 dB to 60 dB 3 maintecn SR Systems 3 6 12 Audio Mode Configures the audio channel mode for the encoded audio data Selected Value Description Stereo The audio from the left and right input is encoded as stereo signal Joint Stereo Stereo encoding with better quality but less stereo channel separation Dual Channel The signal from the left and right input is encoded as two separate mono channels Single Channel The audio is encoded as single mono channel 3 6 13 Audio Samplerate Samplerate Configures the sample rate for analog audio input Possible values are 32 kHz 44 1 kHz 48 kHz 3 6 14 Audio Bitrate Bitrate Configures the bitrate that the encoder uses for audio encoding More bitrate results in better audio quality Possible values depend on the selected Audio Mode see 3 6 12 Possible values for Stereo Joint Stereo and Dual Channel 64 96 112 128 160 192 224 and 256 kBit s CD quality is reached at approx 224 kBit s Possible values for Single Channel 32 48 56 64 80 96 112 128 160 and 192 kBi
5. 01F are passed through to the multiplexer In a standard transport stream those PIDs contain the PSI tables and therefore this option can be used to block those tables Selected Value Description pass PSI Tables are not blocked block PSI Tables are blocked 3 6 Encoder Settings TTX Settings The Encoder Settings TTX Settings submenu is shown for each TS input that is configured to MPEG2 Encoder TTX see 3 1 1 6 See the maintech Application Note About Bitrates http www maintech de fileadmin Datasheets Bitrates pdf for more infor mation on the clock and data rates on transport stream ports 10 maintecn 3 6 1 System Bitrate SR Systems Set the encoder s system bit rate audio video and tables to the given value The modulator does not check if your configured system bitrate fits into the bandwidth provided by the configured modulation settings The user has to make sure that the system bitrate is at least 3 below the modulation bitrate Please enter a bitrate value based on 188 byte packets in kBit s with possible values between 1000 kBit s and 20000 kBit s If the given value is too low the encoding process will stop at the first buffer overflow 3 6 2 Video Input This selects the used hardware input for the video signal IF Selected Value Description disabled Do not encode a video signal The stream will be announced as radio service CVBS Encode signal from t
6. 6 3 4 4 Repetition ese ee ee ac 9 3 82 Bandwidth 17 3 4 5 Network Name 9 3 9 Tuner Settings DVB S 17 3 4 6 Upload PSI tables 10 3 9 1 Frequency 17 3 5 TS InSettings 2 10 3 9 2 Symbolrate 17 3 5 1 Clockrate 2 10 3 9 3 LNC Power 17 3 5 2 PSI Tables 10 3 9 4 LNC 22kHz Tone 17 3 6 Encoder Settings TTX Settings 10 3 10 Tuner Settings DVB C 18 3 6 1 System Bitrate 11 3 10 1 Frequency 18 3 6 2 Video Input 11 3 10 2 Symbolrate 18 3 6 3 Video Format 11 3 10 3 Constellation 18 3 6 4 Video Resolution Resolution 12 3 11 Serial Bridge Settings 18 3 6 5 Video GOP Mode GOP Mode 12 3 11 1 Baudrate 19 3 6 6 Video GOP Size GOP Size 12 3 11 2 Injection 0 19 maintecn SR Systems 3 11 3 Extraction 19 4 5 ASI Input Status 21 3 11 4 Injection PID 19 4 6 Tuner Status 21 3 11 5 Extraction Port 20 4 7 Encoder Status 22 3 11 6 Extraction PID 20 4 8 Output Status 2 23 4 9 MiniMod Status 24 4 Verbose Status Report 20 4 10 PSIStatus 24 4 1 Product Version Information 20 4 2 Global Status 20 5 Status Codes 25 43 Input Status 20 4 4 Input P
7. Application Note About Bitrates http www maintech de fileadmin Datasheets Bitrates pdf for more infor mation on the clock and data rates on transport stream ports maintecn SR Systems 3 3 MiniMod Settings The MiniMod Settings submenu is only visible if a MiniMod was detected at the TS Output All modulation settings of the MiniMod can be controlled from the MidiMux via this menu Please see MiniMod Remote Control in section 6 on page 25 for instructions on how to connect MiniMod and MidiMux For the configuration of the MiniMod see the MiniMod User s Guide 3 4 PSI Settings The MidiMux has a built in PSI table generator which generates ETSI EN 300 468 compliant PSI and SI tables for up to four connected MPEG encoders or in extended mode for an arbitrary number of external services The configuration for the extended mode is created with the help of our maintech Mux Configurator and uploaded to the multiplexer via XModem 3 4 1 PSI Table Generator PSI Tables Selected Value Description disabled The table generator in the MidiMux is disabled simple The simple table generator which generates tables for the encoders directly connected to the MidiMux is enabled extended The extended table generator which is configured with the help of the maintech Mux Configurator is enabled 3 4 2 Stream ID Set the transport stream ID that is transmitted in PAT NIT and SDT for the encoded services 3 4 3 Ne
8. L with 60 Hz and 525 lines PAL M 60 The video signal is interpreted as PAL M PAL with 60 Hz and 525 lines PAL N The video signal is interpreted as PAL 60 PAL with 60 Hz and 525 lines NTSC The video signal is interpreted as NTSC NTSC 4 43 NTSC with color carrier at 4 43 MHz SECAM The video signal is interpreted as SECAM t PAL 60 PAL M PAL N and NTSC 4 43 are only available if a newer encoder with T VP video decoder is connected Older encoders with SAA video decoder only support PAL NTSC and SECAM 3 6 4 Video Resolution Resolution Selected Value Description D1 The video image is encoded with full resolution 720x576 HD1 The video image is encoded with half resolution 360x576 CIF The video image is encoded with quarter resolution 360x288 3 6 5 Video GOP Mode GOP Mode The GOP Mode menu item defines how the encoder uses different frame types while encoding the video stream Selected Value Description l Each GOP consists only of l frames IP The encoder uses one l frame and then only P frames inside a GOP For a GOP size see 3 6 6 of ten the resulting GOP will look like this IPPPPPPPPP IBP The encoder uses an l frame at the beginning of the GOP and encodes the rest in B and P frames For a GOP size of ten the resulting GOP will look like this IBPBPBPBPB IBBP The encoder uses an l frame at the beginning of each GOP and encodes the rest in B and P frames For a GOP size of ten the resultin
9. an be changed with the and buttons If the item does not represent a distinct set of options but a number or a text string the and buttons move the cursor and and change the character under the cursor Use the button to save the changes and press the button to revert the modifications and return to the item selection Figure 4 Editing an item with distinct options and a string item 2 Controlling the MidiMux via the RS232 All configuration options that are available on the frontpanel can also be modified via the RS232 interface on the MidiMux PCB Please refer to the MidiMux hardware datasheet for the pinout 2 1 Establishing a Connection The RS232 interface can be used with standard terminal software e g HyperTerminal included with some versions of the Windows operating system Putty or any other VT100 compatible terminal software Set your PC serial port to 115200 Baud eight bits per character no parity one stopbit 115k2 8N1 and disable any flow control When powering up your MidiMux you should see a boot message similar to this example DVB Midimux Firmware V6 9 c 2009 maintech GmbH FPGA firmware v004 successfully uploaded i MidiMux hardware datasheet http www maintech de fileadmin Datasheets DVB MidiMux_v5 1_Datasheet v1_en 1 pdf 2 Download Putty at http www chiark greenend org uk sgtatham putty download html maintecn SR Systems 2 2 Changing Settings A
10. dules Intelligent tuner modules can be used standalone and be configured via display or serial port When they are connected to a MidiMux with firmware version 6 10 or later the MidiMux will control the tuner module and the tuner s local settings are disabled Plase note that for this feature the NIM s firmware version must be 0 28 or later Supported intelligent tuner modules are e ATSC tuner Datasheet http www maintech de DSIA1 e DiBcom 7000 Datasheet http www maintech de DSIT1 e DVB S S2 tuner Datasheet http www maintech de DSIS2 The MidiMux automatically detects the connected tuner type ASI The MidiMux will control an SR Systems ASI input module ASI In on the TS input port TTX The MidiMux will configure and control an SR Systems MPEG2 encoder with TeleText inserter connected to the TS input port generate clk A transport stream is expected on the TS input port The MidiMux will generate the TS clock with a clock rate configured in the menu item TS In x Settings The data will be latched on rising clock edge external clk A transport stream is expected on the TS input port The MidiMux will expect a TS clock from the connected device The data will be latched on rising clock edge Use this setting when connecting one of the following devices e MiniMux or MidiMux multiplexer See the maintech application note http www maintech de fileadmin Downloads ChainingMultiplexers pdf for information on how to c
11. e 3 9 2 Symbolrate Set the reception symbol rate for the DVB S tuner in kSym s Valid values are in the range between 1000 kSym s and 45000 ksym s 3 9 3 LNC Power Selected Value Description Off The DVB S tuner does not supply power to the HF input 13V The DVB S tuner supplies 13V to the HF input 18V The DVB S tuner supplies 18V to the HF input t The supply of 13 or 18V to the HF input works only if you have connected an additional 24V power supply to your DVB S tuner The NIM does not contain a step up regulator 3 9 4 LNC 22kHz Tone Selected Value Description continued on next page 17 maintecn SR Systems continued from previous page Selected Value Description Off The DVB S tuner does not apply 22kHz to the LNC power supply On The DVB S tuner applies 22kHz signal tone to the LNC power supply t The 22kHz tone works only if you have connected an additional 24V power supply to your DVB S tuner and if you have selected 13V or 18V as LNC power 3 10 Tuner Settings DVB C These menu items are displayed when a DVB C NIM is attached to the MidiMux 3 10 1 Frequency Set the reception frequency for the DVB C tuner in kHz Valid values are between 47000 kHz and 866000 kHz 3 10 2 Symbolrate Set the reception symbol rate for the DVB C tuner in kSym s Valid values are in the range between 1000 kSym s and 7000 ksym s 3 10 3 Constellation Set the reception c
12. ed tuner module NIM It is shown only if a TS input port is set to tuner The type of the detected tuner is displayed in square brackets 4 7 IN1 IN2 INS IN4 Status Display Description MB86A15 DVB S A Fujitsu MB86A15 DVB S tuner SR Systems DVB S NIM has been detected Tuner settings for DVB S are shown in the Tuner Settings menu STV0297 DVB C NXT6000 DVB T A ST Microelectronics STV0297 DVB C tuner SR Systems DVB C NIM has been detected Tuner settings for DVB C are shown in the Tuner Settings menu A NextWave NXT6000 DVB T tuner SR Systems DVB T NIM has been de tected Tuner settings for DVB T are shown in the Tuner Settings menu DIB3000 DVB T A single DibCom DIB3000 DVB T tuner SR Systems DVB T NIM has been detected Tuner settings for DVB T are shown in the Tuner Settings menu 2x DIB3000 Status Display tuner not found A DibCom DIB3000 dual diversity DVB T tuner SR Systems DVB T diversity NIM has been detected Tuner settings for DVB T are shown in the Tuner Settings menu Description No tuner module was detected Check the cable connecting the MidiMux and the tuner module tuner error A tuner module was detected but a fatal error occured while controlling the tuner module The MidiMux continues trying to reinitialize the tuner Check the cable connections and if the problem persists ask for support tuner not locked A tuner module was detected and c
13. ent menu item and commit the changes Browse menu categories change character while editing an item Browse menu items within a category move cursor while editing an item Switch display backlight on and off not used 1 1 Status Screen Under normal conditions the frontpanel display shows the MidiMux status screen On this screen the first line shows the product name which can be slightly different from the example shown here The second line shows the current status code See the MidiMux Status Codes in section 5 on page 25 for a list of possible messages and their meaning Figure 2 MidiMux status screen without and with error message maintecn SR Systems GmbH 1 2 Configuration Menu Whenever you see the status screen on the frontpanel display pushing the button enters the configuration menu The menu items are grouped in various categories To select a category use the and buttons The and buttons will browse the items within the selected category Use the and buttons again to select a different category See MidiMux Menu Structure in section 3 on page 6 for a list of all available categories and menu items Press the button to edit the menu item currently displayed Press the button to exit the menu and return to the status screen Figure 3 Category and menu item selection After selecting an item for editing with the button the value c
14. fter the boot process is complete the MidiMux displays its main menu which also can be re displayed by pressing in the terminal software Midimux Mainmenu 1 show status 2 Port configuration 3 Dutput Settings 4 PSI Settings 5 Serial Bridge Settings gt The contents of the main menu depend on the connected transport stream sources and other settings a tuner will need other settings than the MPEG2 encoder A menu option is selected by entering its number followed by pressing 3 Menu Structure 3 1 Port Configuration 3 1 1 TS x Input Mode TS x Mode This menu item tells the MidiMux what kind of devices are connected to the TS input connectors The item appears once for each of the four TS input ports maintecn SR Systems Selected Value Description disabled MPEG Encoder The MidiMux will not use the TS input port The MidiMux will configure and control an SR Systems MPEG2 encoder module con nected to the TS input port Tuner The MidiMux will configure and control an SR Systems tuner module NIM Supported tuner modules are e DVB S tuner Datasheet http www maintech de DSNS1 e STV0297 DVB C tuner Datasheet http www maintech de DSNC1 e DiBcom 3000 DVB T tuner diversity or single Datasheet http www maintech de DSNTD or http www maintech de DSNT1 e NXT6000 DVB T tuner With firmware version 6 10 or later the MidiMux will also control SR Systems intelligent tuner mo
15. g GOP will look like this IBBPBBPBBP 3 6 6 Video GOP Size GOP Size The GOP Size menu item defines how long each group of pictures from the encoder will be Possible values are from 1 to 250 Depending on the GOP Mode setting this value might be rounded up to the next multiple of 2 or 3 2 maintecn SR Systems 3 6 7 Video AGC The Video AGC menu item controls the automatic gain control of the video input Selected Value Description disabled The video gain is set manually using the Video Gain setting enabled The automatic gain control of the video input is active ts The video AGC and video gain settings are not available for older encoders with SAA video ADC If the input is set to SDI the video AGC is also not available 3 6 8 Video Gain The Video Gain menu item controls the video gain if the automatic gain control is disabled Possible values are from 0 to 300 where 148 is the default value 3 6 9 Audio Input Audio This menu item decides if audio is encoded and transmitted For video only mode set this to disabled Selected Value Description disabled No audio data is encoded and transmitted analog Audio is encoded from the encoder s analog inputs SDI Audio is extracted and encoded from the attached SDI input port 3 6 10 Audio Channel This menu item selects the audio channels for de embedding from SDI It is only available when a SDI input module with support for embedded
16. hain multiplexers e legacy 4 TS multiplexer continued on next page maintecn SR Systems GmbH continued from previous page Selected Value Description 3 2 Output Settings Options in the Output Settings submenu control how data is output on the TS output port t f a MiniMod is connected to the TS output port there is a submenu MiniMod Settings available instead of the submenu Output Settings 3 2 1 Clock direction Clock Selected Value Description external The MidiMux expects a TS clock signal on the TS output port generate The MidiMux generates a TS clock signal on the TS output port 3 2 2 Clockrate This option is only available if the output clock direction is set to generate It configures the rate of the clock output on the TS output port and with that the output data rate of the multiplexer The TS output port outputs one byte each clock cycle A data rate of 30000 kbps thousand bits per second results in a clock rate of 6000 kHz 3 2 3 Framesize Selected Value Description 188 Byte The data on the TS output port is sent in TS packets without Reed Solomon error correction information Each packet has a size of 188 Bytes of payload 204 Byte The data on the TS output port is sent in TS packets with Reed Solomon error correction information Each packet has a size of 204 Bytes 188 Bytes of payload plus 16 Bytes of error correction information See the maintech
17. he encoder s CVBS input YC Encode signal from the encoder s Y C S Video input YCbCr Encode YCbCr signal from the encoder s external video connector Pin 10 is Y pin 12 is Cb Pin 14 is Cr RGB Encode RGB video signal from the encoder s external video connector Pin 10 is green pin 12 is blue pin 14 is red SCART Encode RGBS RGB with external sync video signal from the encoder s external video connector Pin 8 is sync pin 10 is green pin 12 is blue pin 14 is red SDI Encode signal from the attachable SDI input board YCbCr RGB and SCART are only available if a newer encoder board with TVP video decoder chip is connected Older encoders with SAA video decoder only support CVBS and Y C See the MPEG en coder datasheet at http download sr systems de Desc MPEG Encoder V4_Desc en_075dpi pdf for information about the external video connector 3 6 3 Video Format The Video Format menu item configures the encoder to the format that is used on the input signal t The Video Format configuration is not available when SDI is selected on an encoder with a new SDI input extension board The SDI extension board will autodetect the video format in that case Selected Value Description continued on next page sils maintecn SR Systems GmbH continued from previous page Selected Value Description PAL Standard PAL television signal PAL 60 The video signal is interpreted as PAL 60 PA
18. maintecn SR Systems MidiMux Firmware User s Manual Contents 0 Definition 4 3 67 VideoAGC 13 3 68 WVideoGain 13 1 Frontpanel 4 3 69 Audio Input Audio 13 11 Status Screen 4 3 6 10 Audio Channel oaa 13 1 2 Configuration Menu 5 3 6 11 Audio Volume 13 3 6 12 Audio Mode 14 2 Controlling the MidiMux via the RS232 5 3 6 13 Audio Samplerate Samplerate 14 2 1 Establishing a Connection 5 3 6 14 Audio Bitrate Bitrate 14 2 2 Changing Settings 6 3 6 15 Program Video PID Video PID 14 3 6 16 Program Audio PID Audio PID 14 3 Menu Structure 6 3 6 17 Program PMT PID PMT PID 15 3 1 Port Configuration 6 36 18 Teletext PID 15 3 1 1 TS x Input Mode TS x Mode 6 3 6 19 Program ID 15 3 2 Output Settings 44 462 40 4 7 3 6 20 Program Provider Program Prov 15 3 221 Clock direction Clock 8 3 6 21 Program Name 15 3 2 2 Clockrate 8 3 6 22 LCN mode 15 3 223 Framesze bah we ee 3 8 3 6 23 LCNnumber 16 3 3 MiniMod Settings 8 3 7 Tuner Settings Basics 16 3 4 PSI Settings 2 2 2 9 3 7 1 Frequency 16 3 4 1 PSI Table Generator PSI Tables 9 3 7 2 PSI Tables 16 3 4 2 StreamID 9 3 8 Tuner Settings DVB T 16 3 4 3 Network ID 9 3 81 Frequency 1
19. od Remote Control feature work you need to perform the following steps 25 maintecn SR Systems 1 Make sure that MiniMod and MidiMux are connected with a Type 1 1X or 2 cable We recommend using a Type 2 cable A Type 3 cable will not work 2 Make sure that the MiniMod s TS input port is configured to raw TS The settings for clock direction and clock edge do not matter they will be set to the right values automatically 3 Make sure that your MiniMod has at least Firmware Version 54 40 Contact us if your hardware has older firmware When everything worked well the menu item Output Settings in the MidiMux main menu will be replaced by MiniMod Settings You will also see a MiniMod status line in the MidiMux verbose status report All settings you change in the MiniMod Settings menu are stored on the MiniMod immediately So if you disconnect MidiMux and MiniMod the MiniMod will remember those settings If you connect a different MiniMod to the MidiMux you need to check those settings as the MidiMux will always load them from the MiniMod 8 For information about the different cable types see the maintech cable guide http www maintech de fileadmin Datasheets Cable Guide_v1_en 1 pdf 26
20. onfigured but it could not lock to a signal The MidiMux continues trying to retune to the signal Check frequency and modulation settings in the Tuner Settings Menu tuner locked A tuner module was detected configured and locked to a signal Encoder Status encoder running encoder error BOOT disabled disabled This status line tells you about the status of a TS input port that is set to Encoder and the status of the connected MPEG 2 encoder module It is shown only it a TS input port is set to Encoder Status Display Description continued on next page 2 maintecn SR Systems continued from previous page Status Display Description encoder error The MPEG 2 encoder on the TS Input Port could not be booted This could BOOT happen if there is no encoder connected if there is a problem with the cable between encoder and MidiMux or if the encoder is defective encoder error The MPEG 2 encoder on the TS input port was started but an error occured during configuration The abbreviations in the round brackets indicate what part of counfiguration failed Possible values are VID AUD BR and PID encoder running The MPEG 2 encoder on the TS input port is running 4 8 Output Status OUT generate clock 50000 kBit s This status line tells you about the status of the TS Output Port 99 maintecn SR Systems GmbH Status Display Description external clock
21. onstellation for the DVB C tuner Possible values are QAM16 QAM32 QAM64 QAM128 and QAM256 3 11 Serial Bridge Settings The MidiMux is capable of bridging serial data from a GPS device for example over a DVB stream This feature consists of two mechanisms Injection and Extraction Injection means the encapsulation of RS232 data which the MidiMux receives on a serial port into TS packets and sending those packets on the TS output port Extraction means reading TS packets with a specific PID from a specific port and transmitting their contents on the serial port When combining both mechanisms you can build a system that transmits serial data along with video and audio services You could even build a bidirectional serial bridge system 18 maintecn SR Systems 3 11 1 Baudrate This setting configures the baud rate that is used for transmitting and receiving on the serial port Possible values are 300 1200 2400 4800 9600 19200 38400 57600 115200 3 11 2 Injection Selected Value Description disabled Serial Injection is disabled enabled block The MidiMux reads data from the serial port and embeds this data into the transport stream using packets with the PID configured under Injection PID This PID is blocked on both TS inputs to make sure that the serial link is not disturbed by data from the TS input This is the recommended setting enabled pass The MidiMux reads data from the serial
22. ort Status 21 6 MiniMod Remote Control 25 maintecn SR Systems 2010 11 08 11 39 The information in this manual was compiled with care and to our best knowledge nevertheless there are probably some errors left in this document We do not take legal or any other responsibility for the correctness of any information We are happy to receive your feedback If you found an error or think that something should be explained in greater detail don t hesitate to contact us This document is protected by copyright law All trademarks are owned by their respective owners maintech GmbH Phone 49 931 40 70 6 90 Otto Hahn StraBe 15 Fax 49 931 40 70 6 53 D 97204 Hochberg Web http www maintech de Germany EMail docu maintech de maintecn SR Systems 0 Definition The SR Systems MidiMux is a small efficient four port DVB transport stream multiplexer The firmware provided by maintech allows the control of other SR Systems components like NIMs ASI in out and the MiniMod 1 Frontpanel The MidiMux can be controlled via an optional LCD keypad unit connected to the frontpanel connector The frontpanel consists of a LC Display several LEDs and buttons 90000 DOOS Figure 1 Frontpanel display and button arrangement e Power LED e e e FPGA Status LED e Output Device Status LED MiniMod ON AIR LED kas Enter and exit the menu abort data entries Edit the curr
23. port and embeds this data into the transport stream using packets with the PID configured under Injection PID Packets with that PID coming from one of the input ports are not blocked This means that serial data coming from one of the input ports on this PID gets mixed with the inserted serial data This might lead to unexpected behaviour 3 11 3 Extraction Selected Value Description disabled Serial Extraction is disabled enabled block The MidiMux receives TS packets with the PID configured under Extraction PID from the port configured under Extraction Port The contents of those packets are output on the serial port and the TS packets are not forwarded to the output This is the recommended setting enabled pass The MidiMux receives TS packets with the PID configured under Extraction PID from the port configured under Extraction Port The contents of those packets are output on the serial port and the TS packets are also forwarded to the output A second MidiMux or RS232 extractor could extract the same data or the data could be forwarded to another receiver 3 11 4 Injection PID This menu item configures the PID used for RS232 injection if enabled Choose a PID that is unique in your system do not mix audio video or other PIDs with serial data PIDs 6 maintecn SR Systems 3 11 5 Extraction Port This menu item configures which MidiMux input port is used for RS232 extraction Only data coming from
24. r the connected MPEG 2 encoders Custom PSI Filter The MidiMux Extended PSI Generator is active and a custom tableset and or active PID filter was uploaded and is now active Custom PSI Filter incompatible The custom tableset PID filter you have uploaded is incompatible with this MidiMux firmware Please use the latest version of the maintech Mux Config urator see http www maintech de en support information to generate the mbn File and update the MidiMux firmware to the latest version continued on next page 1 http www maintech de fileadmin Downloads MiniModUsersGuide pdf 24 maintecn SR Systems GmbH continued from previous page Status Display Description Custom PSI Filter empty The MidiMux Extended PSI Generator is active but no custom tableset and or PID filter was uploaded Use the maintech Mux Configurator to set up a custom table set and or PID filter Export this configuration as a mbn file and upload this file to the MidiMux Custom PSI Filter error 5 Status Codes The MidiMux Extended PSI Generator is active and an error occured while exe cuting the custom table set or filter program Please ask for support Possible status codes that are reported by the MidiMux on its frontpanel Status Display Description The MidiMux firmware is booting and initializing the hardware This state is reported only for a short time during powerup
25. t is set to disabled external clock or generate clock If the port is set to tuner ASI or encoder different status lines which are explained in the following sections are shown Status Display Description input disabled The TS input port has been disabled external clock The TS input port has been configured to receive TS clock and data from an external device generate clock kBit s ASI Input Status ASI In HW Error ASI In V34 locked disabled disabled The TS input port has been configured to provide TS clock to and receive data from an external device The TS clock is set up to receive the specified bitrate on the port This status line tells you about the status of a TS input port that is set to ASI and the status of the connected ASI input module It is only shown if a TS input port is set to ASI Status Display Description ASI In V locked The TS input is ok and locked to a ASI signal The firmware version of the ASI input module is shown in the status message ASI In V not locked The TS input is ok but not locked to a ASI signal ASI In HW Error Tuner Status MB86A15 tuner locked The ASI input module was not detected or is faulty DIB3000 4 Way tuner error disabled disabled 2 maintecn GmbH SR Systems This status line tells you about the status of a TS input port that is set to tuner and the status of the connect
26. t s CD quality is reached at approx 160 kBit s 3 6 15 Program Video PID Video PID Set the DVB PID used to transmit the video data Valid values are between 0x0020 and 0x1FFE The video PID must be unique make sure that it is not used for anything else e g audio PMT etc If you plan to multiplex multiple streams make sure that the video PID is unique among all other PIDs in the resulting multiplex 3 6 16 Program Audio PID Audio PID Set the DVB PID used to transmit the audio data Valid values are between 0x0020 and Ox1FFE The audio PID must be unique make sure that it is not used for anything else e g video PMT etc If you plan to multiplex multiple streams make sure that the audio PID is unique among all other PIDs in the resulting multiplex 14 maintecn SR Systems 3 6 17 Program PMT PID PMT PID Set the DVB PID used to transmit the PMT for the encoded service Valid values are between 0x0020 and 0x1FFE The PMT PID must be a unique PID that is not used for video audio or anything else If you plan to multiplex multiple streams make sure that the PMT PID is unique in the whole multiplex 3 6 18 Teletext PID Set the DVB PID used to transmit teletext data for the encoded service Valid values are between 0x0020 and Ox1FFE The teletext PID must be a unique PID that is not used for video audio PMT or anything else If you plan to multiplex multiple streams make sure that the teletext PID is
27. that port will get extracted and transmitted on the RS232 port 3 11 6 Extraction PID This menu item configures the PID used for RS232 extraction if enabled Choose the same PID as you used as Injection PID on the device where the RS232 gets injected 4 Verbose Status Report When controlling the MidiMux via the RS232 serial port as described in section 2 you can get a verbose status report from the MidiMux by choosing option 1 Show Status in the main menu The meanings of the different lines in the verbose status reports are explained in the sections below 4 1 Product Version Information DVB MidiMux CPU V6 9 FPGA 004 This line gives you information about the product DVB MidiMux the CPU and the FPGA software versions 4 2 Global Status Current Status running This line gives you information about the current global status of the MidiMux The status message shown here is the same as shown on the frontpanel display Detailed information on the possible status messages and their meaning can be found in section 5 4 3 Input Status Input status 1 0N 2 0FF 3 0FF 4 0FF This status line tells you which of the TS Input Ports are currently active and forwarding their data to the TS output port 20 maintecn SR Systems GmbH Input Port Status generate clock 30000 kBit s input disabled input disabled input disabled This status line tells you about the status of each TS input port tha
28. twork ID Set the network ID that is transmitted in the NIT for the encoded services 3 4 4 Repetition Set the PSI table repetition time in ms Valid values are between 25 ms and 500 ms Setting the repetition rate to 250 ms results in the complete set of PSI tables being transmitted 4 times per second 3 http www maintech de fileadmin Downloads MiniModUsersGuide pdf See http www maintech de en support information for the actual MuxConfigurator maintecn SR Systems 3 4 5 Network Name Set the network name that is transmitted in the NIT for the encoded services 3 4 6 Upload PSI tables t This menu item is only available if the extended table generator is enabled It is also only accessible via the serial RS232 port Select this menu item to upload a binary configuration file generated by the maintech MUX configurator After selection you need to send the file via XModem 3 5 TS In Settings The TS In Settings submenu is shown for each TS input that is configured to generate clock or external clock 3 5 1 Clockrate tS The menu item Clockrate is only shown if the TS input is configured to generate clock The TS input port reads one byte each clock cycle A data rate of 30000 kbps thousand bits per second results in a clock rate of 6000 kHz Please note that the clock rate at TS input ports is calculated for 204 Byte packets 3 5 2 PSI Tables This menu item controls if PIDs in the range from 0x0000 to 0x0
29. unique in the whole multiplex tS This menu item is shown only if a TTX inserter is connected to the TS input and the input mode is set to TTX 3 6 19 Program ID Set the service ID transmitted in the PAT PMT NIT and SDT 3 6 20 Program Provider Program Prov Set the service provider name transmitted in the SDT 3 6 21 Program Name Set the service name transmitted in the SDT 3 6 22 LCN mode Determines if a Logical Channel Number for this service is sent in the NIT Selected Value Description disabled No Logical Channel Number is signalled for the service visible The Logical Channel Number is signalled as visible channel hidden The Logical Channel Number is signalled as hidden command 15 maintecn SR Systems 3 6 23 LCN number Set the Logical Channel Number that is sent in the NIT for this channel t This menu item is only shown if LCN mode is set to visible or hidden 3 7 Tuner Settings Basics The Tuner Settings submenu is available when a TS input is configured to Tuner mode see 3 1 1 and a compatible NIM network interface module is attached to the TS input port The MidiMux will automatically detect the tuner type and display the corresponding settings 3 7 1 Frequency All NIM modules need a frequency to tune onto The frequency is given in kHz and refers to the center of the channel See the specific sections for DVB T S and C for the allowed ranges 3 7 2 PSI
Download Pdf Manuals
Related Search
Related Contents
Mode d`emploi Fujitsu LIFEBOOK A555 Garantie - GE Measurement & Control OrgPublisher 9 User Guide 1e LiPoTx Operating instructions HP Z820 Workstation ArchiTachy© MANUEL UTILISATEUR 取扱説明書 - 三菱電機 プラボーくん®PSKAir Battery Information Sheet Primary Li-SO2 single cells and multi Copyright © All rights reserved.