1. information on how fan speed is controlled by the shelf man yA Referto Temperature Management on page 16 for detailed agement hub NOTE Fans Specifications The fan tray module houses three Delta FFB0812E HE 9U34 fans Rated voltage 12V DC Operating voltage 7 0 to 13 8 V DC Input current 0 75 A 0 9 A max Input power 9 0 W 10 8 W max Speed 5700 rpm ref Maximum airflow 2 270 m minute 2 040 m3 minute minimum at zero static pressure 80 16 CFM 72 04 CFM minimum Maximum air pressure at 20 63 mm H50 16 71 mm H30 minimum zero airflow 0 812 inch H50 0 658 inch H 0 minimum Acoustical noise average 52 5 dBa 56 5 dBA maximum Insulation type UL Class A 8 Hardware Information 2 5 Power Supply aTCA 8202 The aTCA 8202 comes with single builtin 650W TS 7000 Z power supply Specifications Input Voltage 100 240VAC Current 7 9 3 5A Frequency 47 63Hz Output Voltage 48 0V 13 5A Max Power Output 650 W Hardware Information ADLINK PA This page intentionally left blank 10 Hardware Information aTCA 8202 3 Getting Started This chapter provides information on procedures to begin using the aTCA 8202 shelf or if there is missing incomplete equipment Doing so may DO NOT install or apply power to equipment that is damaged cause damage to equipment or bodily harm WARNING 3 1 Ins
2. ADLINK PA aTCA 8202 2U 2 slot AdvancedTCA Shelf User s Manual ADLINK Manual Revision 2 00 Revision Date August 12 2011 Part No 50 1G010 1000 Recycled Paper Advance Technologies Automate the World A ADLINK pM c o E Revision Revision History Release Date Description of Change s 2 00 2011 08 12 Initial Release aTCA 8202 Preface Copyright 2011 ADLINK Technology Inc This document contains proprietary information protected by copy right All rights are reserved No part of this manual may be repro duced by any mechanical electronic or other means in any form without prior written permission of the manufacturer Disclaimer The information in this document is subject to change without prior notice in order to improve reliability design and function and does not represent a commitment on the part of the manufacturer In no event will the manufacturer be liable for direct indirect special incidental or consequential damages arising out of the use or inability to use the product or documentation even if advised of the possibility of such damages Environmental Responsibility ADLINK is committed to fulfill its social responsibility to global environmental preservation through compliance with the Euro pean Union s Restriction of Hazardous Substances ROHS direc tive and Waste Electrical and Electronic Equipment WEEE directive Environmental prote
3. ADLINK Technology Singapore Pte Ltd Indian Liaison Office Address No 1357 Anupama Sri Aurobindo Marg 9th Cross JP Nagar Phase Bangalore 560078 India Tel 91 80 65605817 Fax 91 80 22443548 Email india adlinktech com 136 Getting Service
4. market adlinktech com ADLINK Technology Shenzhen Address QUIT MUKA a Ke AR Ii A1 k2 EE C IX 518057 2F C Block Bldg A1 Cyber Tech Zone Gao Xin Ave Sec 7 High Tech Industrial Park S Shenzhen 518054 China e Tel 86 755 2643 4858 Fax 86 755 2664 6353 Email market adlinktech com Getting Service 135 ADLINK TECHNOLOGY INC ADLINK Technology Europe GmbH Address Nord Carree 3 40477 Duesseldorf Germany Tel 49 211 495 5552 Fax 49 21 1 495 5557 Email emea adlinktech com ADLINK Technology Inc French Liaison Office Address 15 rue Emile Baudot 91300 Massy CEDEX France Tel 33 0 1 60 12 35 66 Fax 33 0 1 60 12 35 66 Email france adlinktech com ADLINK Technology Japan Corporation Address 1101 0045 WAP TARH DK Ab EH SERA NY 3 7 4 bm 374 CL AE KANDA374 Bldg 4F 3 7 4 Kanda Kajicho Chiyoda ku Tokyo 101 0045 Japan Tel 81 3 4455 3722 Fax 81 3 5209 6013 Email japan adlinktech com ADLINK Technology Inc Korean Liaison Office Address ASA M amp T 425 1675 12 219444 oz 8F Mointer B D 1675 12 Seocho Dong Seocho Gu Seoul 137 070 Korea Tel 82 2 2057 0565 Fax 82 2 2057 0563 Email korea adlinktech com ADLINK Technology Singapore Pte Ltd Address 84 Genting Lane 07 02A Cityneon Design Centre Singapore 349584 Tel 65 6844 2261 Fax 65 6844 2263 Email singapore adlinktech com
5. require careful handling and proper installation ATCA blades are equipped with locking handles and retention screws for easy installation and removal Improper installation of ATCA blades may damage the back plane WARNING Inserting an ATCA blade into the shelf 1 If necessary remove any filler blades from the aTCA 8202 shelf to expose the desired ATCA slot 2 Align the blade with the card guides of the desired slot of the shelf 3 Position the ATCA blade into the slot then carefully slide its edges into the blade guide rail Make sure that the blade is correctly aligned with the shelf to prevent dam age to the blade and or backplane 4 Push the blade into the slot until the handles come in contact with the shelf and the metal tacks insert into the shelf holes 5 Push the handles inward until they click in place 6 Fasten the retention screws turning in a clock wise direction at both ends of the blade to secure itin place 12 Getting Started aTCA 8202 Removing an ATCA blade from the shelf 1 Loosen the retention screws on both sides of the blade 2 Unlatch the ATCA blade handles and pull them outward until the blade disengages from the shelf 3 Carefully pull the blade out from the shelf then store ina safe place 3 3 Shelf Management Hub The aCMM 2200 Shelf Management Hub is not serviceable by the user If you encounter any problems with the aCMM 2200 please contact ADLINK 3 4 P
6. 200 Shelf Management Hub Equipped with a dual star topology fabric interface the aTCA 8202 comes with a hot swap pable fan tray module push cooling and one 650W AC power supply Providing robust control monitoring and management of the aTCA 8202 is the aCMM 2200 Shelf Management Hub with full system management capabilities and built in non manageable Layer 2 GbE switch for Base Interface connectivity With dual IPMB and I2C system busses the aCMM 2200 can control all installed AdvancedTCA blades and the fan tray module based on temperature and other built in sensor readings 1 1 Features 19 rackmount shelf 2U height and 15 3 depth Two ATCA slots with dual star topology fabric interface No support for rear transition modules RTM Dual IPMB bus One l2C controlled hot swappable fan tray module Single slot foran aCMM 2200 Shelf Management Hub with Layer 2 GbE switch for Base Interface connectivity Single 650W AC power supply ww www V Introduction 1 A ADLINK pM CHNOLOGY INC 1 2 Specifications Form Factor 19 rackmount 2U height 15 3 depth Fits inside a 600 mm deep cabinet Specification Supports up to two standard AdvancedTCA blades Supports one shelf management hub with aCMM 2 installed Shelf Management Supports multiple management interfaces including 200 Remote Management Control Protocol RMCP Remote Procedure Call RPC Simple Network Management Protocol SN
7. 459C Fan Level 7 Critical 509C Fan Level 15 Non Recoverable 652C Shutdown all blades Table 3 1 aTCA 8202 Backplane Thermal Thresholds Each time an alarm is received by the ShMH an event record will be written to the System Event Log SEL System administrators may use the the clia command to check the SEL clia sel or to verify the fan speeds detected and adjusted by the ShMH clia fans Non Critical Threshold When a temperature sensor monitored by the ShMH issues an alarm thata device shelf or blade has exceeded the non criti cal threshold the fan speed will increase by one level The fan speed will continue to increase by one level every 30 seconds as long as the alarm continues to be issued When the alarm turns off the fan speed will decrease by one level every 30 seconds Critical Threshold When a temperature sensor monitored by the ShMH issues an alarm that a device shelf or blade has exceeded the critical 16 Getting Started aTCA 8202 threshold the fan speed will immediately increase to Level 15 to provide maximum cooling Non recoverable Threshold When a temperature sensor monitored by the ShMH issues an alarm that a device shelf or blade has exceeded the non recoverable threshold the ShMH will shut down all blades to protect them from damage The shelf and ShMH will remain powered on and the blades can be reactivated manually by removing and reinserting them into the shelf or by rem
8. MP Command Line Interface CLI Web Base Interface Dual Fast Ethernet ports and one serial console for management access Layer 2 GbE switch for Base Interface connectivity non manageable Cooling System Single hot swappable 12C controlled fan tray module Right to left transverse airflow push cooling Backplane Dual star topology Base Interface Dual star topology Fabric Interface e Dual IPMB bus Power Filter 650W builtin power supply input 100 240VAC Weight barebone 11 5kg including power supply Temperature Operating 02C to 50 C Storage 202C to 80 C Humidity 5 to 95 non condensing Dimensions 432mm x 87mm x 485 6mm W xH x D Compliance PICMG 3 0 AdvancedTCA Specification R3 0 PICMG 3 1 AdvancedTCA Ethernet Certifications CE FCC designed for NEBS Level 3 Table 1 1 aTCA 8202 Shelf Specifications 4 NOTE Specifications are subject to change without notice Introduction aTCA 8202 1 3 Shelf Management Hub The aCMM 2200 Shelf Management Hub is based on a Pigeon Point Systems shelf management controller to provide full system management capabilities It comes with built in non manageable Layer 2 GbE switch to provide Base Interface connectivity for the aTCA 8202 s two ATCA slots A functional block diagram is shown below aCMM 2200 Shelf Management Hub i PC A B Backplane Figure 1 1 aTCA 8202 aCMM 2200 Functional Block Diagra
9. ction is a top priority for ADLINK We have enforced measures to ensure that our products manu facturing processes components and raw materials have as little impact on the environmentas possible When products are at their end of life our customers are encouraged to dispose of them in accordance with the product disposal and or recovery programs prescribed by their nation or company Trademarks Product names mentioned herein are used for identification pur poses only and may be trademarks and or registered trademarks of their respective companies Preface iii ADLINK TECHNOLOGY INC Using this Manual Audience and Scope The aTCA 8202 Users Manual is intended for hardware technicians and systems operators with knowledge of installing configuring and operating ATCA systems Manual Organization This manual is organized as follows Chapter 1 Introduction Introduces the aTCA 8202 its features and package contents Chapter 2 Hardware Information Provides information on the physical features dimensions and pre installed hardware components of the aTCA 8202 Chapter 3 Getting Started Provides information on procedures to begin using the aTCA 8202 Chapter 4 Shelf Maintenance Provides information on maintaining the aTCA 8202 Important Safety Instructions Presents safety instructions all users must follow for the proper setup installation and usage of equipment and or software Getting Service Con
10. el Hardware Information 5 ADLINK 2 2 Mechanical Dimensions 432 a ba CO CO n KS 481 8 465 1 A 1 NIN LS Dimensions in mm Figure 2 3 aTCA 8202 Mechanical Dimensions 6 Hardware Information aTCA 8202 2 3 Backplane The aTCA 8202 shelf comes with a cBP 5020 backplane featuring two AdvancedTCA slots that do not support rear I O functionality and a dedicated slot for an aCMM 2200 Shelf Management Hub Features gt Dual star topology Base Interface gt Dual star topology Fabric Interface gt Dual IPMB bus Specifications gt PICMG 3 0 AdvancedTCA Base R3 0 PICMG 3 1 AdvancedTCA Ethernet R 1 0 Hardware Information 7 A ADLINK PA CHNOLOGY INC 2 4 Cooling System Fan Tray Module The aTCA 8202 shelf is equipped with one fan tray module that has three fans to provide optimum cooling for AdvancedTCA blades The hot swappable fan tray module is located at the right of the shelf with air flow from right to left push cooling Refer to Fan Tray Module on page 19 for details on removing 3 and replacing the fan tray module NOTE Fan Control The aCMM 2200 detects and adjusts fan speed based on two temperature sensors located on the backplane
11. m Introduction 3 ADLINK TECHNOLOGY INC 1 4 Ordering Information aTCA 8202 AC 2U 2 slot Rackmount AdvancedTCA System with single aC MM 2200 Shelf Management Hub 1 5 Package Contents Before unpacking check the shipping carton for any damage If the shipping carton and or contents are damaged inform your dealer immediately Retain the shipping carton and packing mate rials for inspection Obtain authorization from the dealer before returning any product to ADLINK The following contents are included in the shipping carton gt aTCA 8202 ATCA Shelf gt aCMM 2200 Shelf Management Hub ShMH gt Accessory package gt Rackmount brackets gt Retention screws for ATCA and ShMH slots are available and may be purchased F4 The aTCA 8202 does NOT include slot filler panels Filler panels separately NOTE 4 Introduction aTCA 8202 2 Hardware Information This chapter provides information on the external layout and pre installed hardware components of the aTCA 8202 The following illustrations present an aTCA 8202 shelf and are Z intended for reference only The figures below may differ from your actual shelf configuration NOTE 2 1 External Layout el E Status Ground Power Shelf Management Serial LAN LED Terminal Button Module Port Ports Fan Tray Module Figure 2 1 aTCA 8202 Shelf Front Panel AC Power Circuit Inlet Breaker Figure 2 2 aTCA 8202 Shelf Rear Pan
12. ooooomomo 12 Inserting an ATCA blade into the shelf 12 Removing an ATCA blade from the shelf 13 3 3 Shelf Management Hub 13 Table of Contents vii A ADLINK BA TECHNOLOGY INC 3 4 Powering Up the System 13 3 5 Managing the Self icon emas 14 aCMM 2200 Shelf Management Hub o ooooo oWooo 14 Serial Connection UV 14 LAN CONneGtON deeg enee aides 15 Temperature Management ooooooooW Woo 16 4 Shelf Maintenance oo o oma 19 4 1 FAN Tray Module tente niti 19 Removing the fan tray module o oooooooooWo Woo Wo 19 Replacing the fan tray module sesser 20 Important Safety Instructions 21 Getting EE 23 viii Table of Contents aTCA 8202 List of Figures Figure 1 1 aTCA 8202 aC MM 2200 Functional Block Diagram 3 Figure 2 1 aTCA 8202 Shelf Front Panel 5 Figure 2 2 aTCA 8202 Shelf Rear Panel 5 Figure 2 3 aTCA 8202 Mechanical Dimensions o oo 6 List of Figures ix ADLINK This page intentionally left blank D List of Figures aTCA 8202 List of Tables Table 1 1 aTCA 8202 Shelf Specifications 2 Table 3 1 aTCA 8202 Backplane Thermal Thresholds 16 List of Tables xi ADLINK This page intentionally left blank xii List of Tables aTCA 8202 1 Introduction The aTCA 8202 is a 2U AdvancedTCA shelf with two slots that support AdvancedTCA blades and a dedicated slot for an aCMM 2
13. ote com mand Getting Started 17 ADLINK This page intentionally left blank 18 Getting Started aTCA 8202 4 Shelf Maintenance This chapter provides information on how to remove and replace user serviceable components on the aTCA 8202 4 1 Fan Tray Module This section provides information on how to remove and replace the fan tray module which is located on the right side of the shelf front panel The fan tray is hot swappable and may be replaced while the shelf is operating To obtain replacement fan modules contact ADLINK or your Z local distributor NOTE Removing the fan tray module 1 Loosen the two retention screws on the right side of the aTCA 8202 shelf 2 Use your thumbs to pull the fan tray module outwards from the shelf and detach the connectors from the back plane To avoid injury wait at least five seconds or until all fans have stopped rotating before removing fan tray WARNING 3 Fully remove the fan tray module from the shelf Shelf Maintenance 19 A ADLINK pM TECHNOLOGY INC Replacing the fan tray module l Insert the fan tray module into the right side of the aTCA 8202 shelf 2 Secure the fan tray module to the shelf by tightening the two of retention screws 20 Shelf Maintenance aTCA 8202 Important Safety Instructions For user safety please read and follow all instructions WARNINGS CAUTIONS and NOTES marked in this manual and on the as
14. owering Up the System After installing all necessary components you are now ready to power up the system To connect the aTCA 8202 to an AC power source 1 Insert the AC power plug into the socket at the rear of the shelf and push the circuit breaker to the right to set it to the ON position 2 Press the power button located at the top left of the front panel 3 When the shelf is powered up the power button LED lights blue and the cooling fans begin rotating The aCMM 2200 Shelf Management Hub powers up immediately and the Status LED lights up green If the Status LED lights red this indicates a problem exists with the shelf check the System Event Log SEL using the the clia command clia sel Getting Started 13 ADLINK PA 3 5 Managing the Shelf aCMM 2200 Shelf Management Hub The aTCA 8202 is equipped with one aCMM 2200 Shelf Manage ment Hub ShMH to provide shelf management functionality A When an aCMM 2200 ShMH is NOT installed in the shelf all fans in the fan tray module will rotate at full speed Level 15 NOTE To access fan temperature ATCA blade FRU field replaceable unit and power information the installed ShMH must be con nected to a host computer using one of the following serially using an DB9 cable gt over a LAN using a standard RJ 45 cable b via network switch or hub Serial Connection You may use the bundled DB9 cable to connect the shelf serially to a host comp
15. rding to their instructions Equipment must be serviced by authorized technicians when gt gt gt gt V 22 The power cord or plug is damaged Liquid has penetrated the equipment It has been exposed to high humidity moisture It is not functioning or does not function according to the user s manual It has been dropped and or damaged and or Ithas an obvious sign of breakage Important Safety Instructions aTCA 8202 Getting Service Contact us should you require any service or assistance ADLINK Technology Inc Address 9F No 166 Jian Yi Road Zhonghe District New Taipei City 235 Taiwan Prac TTP AGE 166 57 9 Tel 886 2 8226 5877 Fax 886 2 8226 5717 Email service adlinktech com Ampro ADLINK Technology Inc Address 5215 Hellyer Avenue 110 San Jose CA 95138 USA Tel 1 408 360 0200 Toll Free 1 800 966 5200 USA only Fax 1 408 360 0222 Email info adlinktech com ADLINK Technology China Co Ltd Address Lini AGE PCT ES PE PAIX trik 300 201203 300 Fang Chun Rd Zhangjiang Hi Tech Park Pudong New Area Shanghai 201203 China Tel 86 21 5132 8988 Fax 86 21 5132 3588 Email market adlinktech com ADLINK Technology Beijing Address JER AVEK EIER 1 SAONE E 801 100085 Rm 801 Power Creative E No 1 B D Shang Di East Rd Beijing 100085 China Tel 86 10 5885 8666 Fax 86 10 5885 8625 Email
16. sociated equipment before handling operating the equipment gt Read these safety instructions carefully Keep this user s manual for future reference gt Read the specifications section of this manual for detailed information on the operating environment of this equipment When installing mounting or uninstalling removing equipment Turn off power and unplug any power cords cables gt To avoid electrical shock and or damage to equipment Keep equipment away from water or liquid sources Keep equipment away from high heat or high humidity Keep equipment properly ventilated do not block or cover ventilation openings Make sure to use recommended voltage and power source settings Always install and operate equipment near an easily accessible electrical socket outlet Secure the power cord do not place any object on over the power cord Only install attach and operate equipment on stable surfaces and or recommended mountings and If the equipment will not be used for long periods of time turn off and unplug the equipment from its power source v Important Safety Instructions 21 ADLINK gt Never attempt to fix the equipment Equipment should only be serviced by qualified personnel gt A Lithium type battery may be provided for uninterrupted backup or emergency power A CAUTION Risk of explosion if battery is replaced with one of an incorrect type Dispose of used batteries acco
17. tact information for ADLINK s worldwide offices iv Preface aTCA 8202 Conventions Take note of the following conventions used throughout this manual to make sure that users perform certain tasks and instructions properly yA Additional information aids and tips that help users perform tasks NOTE Information to prevent minor physical injury component dam age data loss and or program corruption when trying to com plete a task CAUTION Information to prevent serious physical injury component damage data loss and or program corruption when trying to complete a specific task WARNING Preface V ADLINK This page intentionally left blank vi Preface aTCA 8202 Table of Contents Revision HIStOfYy o amen min ii Prota aah iii List of FIQUEFGS r a nantais ix List of I ee tanah adan nee xi 1 Introduction E 1 Lied ll 1 12 SpecifiCatiors uio Er nana kemana 2 13 Shelf Management Hub 3 14 Ordering Information 4 1 5 Package Contents danse steele 4 2 Hardware Information oom 5 2 1 External LayOUt tenan ardent mans 5 2 2 Mechanical Dimensions 6 KC Wl ue ELE 7 2 4 Cooling SYSTEME elites 8 Fan Tray Module ssssse meme 8 FAN Control EE 8 Fans Specifications ine cdita eei aan 8 25 Powersupply item basa lt a tne 9 3 Getting Started eee am nnn nnmn 11 3 1 Installation Environment 11 3 2 Inserting and Removing ATCA Blades ooo
18. tallation Environment Whenever unpacking and preparing to install any equipment described in this manual please refer to the Important Safety Instructions chapter of this manual The aTCA 8202 contains electrostatically sensitive equipment that can be easily damaged by static electricity The equipment must be handled on a grounded anti static mat The operator must wear an anti static wristband grounded at the same point as the anti static mat Inspect the carton and packaging for damage Shipping and han dling could cause damage to the equipment inside Make sure that the equipment and its associated components have no damage before installing The equipment must be protected from static discharge and physical shock Never remove any of the socketed parts except ata static free workstation Use the anti static bag shipped with the product to handle the equipment and wear a grounded wrist strap when servicing CAUTION Getting Started 11 ET A ADLINK TECHNOLOGY INC 3 2 Inserting and Removing ATCA Blades This section describes the insertion and removal procedures for ATCA product and filler blades ATCA blades are hot swappable and itis not necessary to power down the shelf to insert or remove them The same insertion removal procedures apply to filler blades with the exception that filler blades do not have levers The aTCA 8202 is designed with two slots that support ATCA blades ATCA connectors are rigid and
19. uter Refer to the illustration below ShMH module Wom DB9 cable Host computer 14 Getting Started aTCA 8202 The aCMM 2200 ShMH COM port is set with the following default parameters Type RS232 COM Baud Rate 115200bps Data Bits 8 Parity None Stop Bits 1 Flow Conirol None LAN Connection Using a Fast Ethernet connection you may connect the ShMH directly to a notebook or PC using an RJ 45 cable or to a network switch or router for high speed remote management Refer to the following illustrations ShMH module RJ 45 cable Host computer By default the LAN1 port has the following settings IP 172 16 13 209 Login name root Password None Getting Started 15 A ADLINK BA ECHNOLOGY INC Temperature Management The aTCA 8202 shelf has two temperature sensors on the left and right sides of the backplane The aCMM 2200 ShMH automatically detects these sensors and the temperature sensors on installed ATCA blades The ShMH uses these sensor readings to dynami cally adjustthe fan speed to maintain safe shelf and blade temper atures The table below lists the temperature thresholds and Fan Level settings applied by the ShMH as dictated by detected backplane temperatures Temperature thresholds of ATCA blades will vary Please refer to the user manual provided by the blade manufac turer Threshold Temperature Action Non Critical
Download Pdf Manuals
Related Search
Related Contents
Manual Administrador Empresas Ultraschall-Reinigungsgerät SUR 46 A1 Comunicado XF300 Olivetti ECR 7700 LG LMVH1711ST Specification Sheet Samsung CT-21S4W User Manual User`s Guide for Nokia N73 - File Delivery Service 54U 取扱説明書 (操作用) 電力マルチメータ 目 次 - M Measuring the Electron Beam Energy in a Magnetic Intelligent Backup - German Sales Agency Copyright © All rights reserved.