Home
User's Guide - Beijer Electronics
Contents
1. DESIGNER verscus Information Designer User s Guide Preface Information Designer is a software application for the configuration of CIMREX and EXTER operator terminals Information Designer helps you create logical flexible and effective HMI applications that provide the right information on the right occasion to operators and other systems This manual is based on an example project that the user completes step by step Information Designer also includes a Reference Manual MA00749 Beijer Electronics AB MA00750A 2005 02 The information in this document is subject to change without notice and is provided as available at the time of printing Beijer Electronics reserves the right to change any informa tion without updating this publication Beijer Electronics assumes no resposibility for any er rors that may appear in this document All examples in this manual are only intended to improve understanding of the functionality and use of the software Beijer Electronics AB cannot assume any liability if these examples are used in actual applications In view of the wide range of applications for this software users must acquire sufficient knowledge themselves in order to ensure that the software is correctly used in their specific application Beijer Electronics AB will accept no liability for any damage incurred during the installation or use of this software Beijer Electronics AB prohibits all modific
2. The Operator Terminal as an FTP 15 The Operator Terminal as an FTP Server FTP File Transport Protocol is a standard Internet protocol When the operator terminal works as an FIP server it is possible to upload download files to from the operator terminal e g recipe files An FTP client is required in order to upload download files CIMREX Tools Internet Explorer Windows Commander or some other standard FTP program can be used as the FTP client The FTP server in the operator terminal only allows transfers in passive mode The operator terminal does not utilize the date stamps on files The date shown in the FTP client shall therefore be ignored Language specific characters are not supported in file names The files in the different librar ies in the operator terminal allocate memory from the project memory Information on the available project memory is included in the file in fo txt 15 1 Activate FTP Server 1 Select Setup Network Services 2 Select FTP Server 3 Click Exit Setup Network Services Available network services Application transfer server BDTP client BDTP server FTP server Internet server SMTP client Terminal controller Beijer Electronics MA00750A 33 Fig 1 The file structure in the operator terminal 34 Beijer Electronics MA00750A Beijer Electronics HMI Products is a pioneer in connecting people with the processes they control Our HMI soluti
3. e Whole project e Single 1 0 change Exit C Selected objects C Move l 0 range From 1 0 DO 177 PO To I O pl o H Confirm each change 30 Beijer Electronics MA00750A Test the Project 13 Test the Project We shall now test the project Select Project Test Test results EN Project is valid OK If you want to test run the project this can be done in the simulator Beijer Electronics MA00750A 31 Dual Drivers 14 Dual Drivers It is possible to use two different drivers in the operator terminal which means that the operator terminal can communicate with two different controllers simultaneously l 2 3 4 5 Select Project Properties Controller 2 In the dialog that opens select Demo Finish with OK Create a new block and name it Dual Drivers Make a jump from the main block to Dual Drivers Add an analog numerical object and connect it to CO Add a speedometer and connect it to DO 2 controller 2 14 1 Data Exchange between Controllers Ee 2 Select Functions Data exchange Make the following settings Controller Data Exchange Area Start 0 1 C0 WO Signed 16 bit Stat 702 D0 Signed 16 tit Flow 1 gt 2 Trigger signal Wo Interval s 5 Flow 2 gt 1 Trigger signal WO Interval s 0 Mode Areal Area2 Size Trigger1 gt 2 Intervall gt 2 Trigger2 Inter Analog CO DO 2 1 5 32 Beijer Electronics MA00750A
4. in the project 1 Select View IO Cross Reference 2 You can specify the start and end signals for example DO to D99 If no interval is specified all I O signals in use are shown The list that is shown describes the signals with blocks objects and pixel positions No interval is specified for the list below M Users_Guide cpa 1 0 Cross Reference I O M0 Block 0 Digital Text 243 88 Block 4 Digital Text 2 4 Alarm Security door open 1 0 M1 Block 4 Analog Numeric 2 11 UA M2 Block 4 Analog Numeric 2 20 140 M10 4 Report l 0 CO Block 2 Trend 129 36 l 0 C1 Block 2 Trend 129 36 140 DO Block 0 Slide 128 210 Block 0 Speedometer 295 220 140 D10 Block 3 Analog Numeric 5 124 40 D11 Block 3 Analog Numeric 81 124 l 0 D12 Block 3 Analog Numeric 157 124 1 0 D13 Block 3 nalog Numeric 233 124 I O D14 Block 3 Analog Numeric 309 124 l 0 D15 Block 3 Analog Numeric 385 124 3 I O D16 Block 3 nalog Numeric 461 124 l 0 D17 Block 3 nalog Numeric 537 124 Beijer Electronics MA00750A 29 I O Change 12 1 0 Change In this chapter we describe how you can easily change a signal throughout the entire project We shall change DO to D1 1 Select Edit I O Change 2 Type DO under From I O and D1 under To I O 3 Click Start to implement the change I O Change Change 1 0 in Change
5. 00 Fax 886 2 2218 9547 hmi hitech Icd com tw 60 2002 WVOSZOOVN
6. None Offset Gei Raised frame Sunken frame MB lBeckoround EI Note Do not forget to activate Enable operator input on the Access tab 22 Beijer Electronics MA00750A 3 Add a static text object and type D10 as the text in the block Static Text General Appearance Font Dynamics Text Alignment Border style Left Gei None Center Raised Right Sunken Raised frame Sunken frame Beijer Electronics MAQ0750A 23 9 1 Copy Object 4 Select the objects by dragging a frame around them and press Ctrl C Then press Ctrl V in order to paste a copy Move the copy so that they are lined up 5 Edit the new object by double clicking it Change the signal to D11 in both the static text and the analog numerical object 24 Beijer Electronics MA00750A Create a Recipe Block 9 2 Create a Series 6 Select the analog numerical objects and select Object Create Series 7 Specify the number of columns as 6 8 Finish with OK A series is now created of the relation between the two objects first created 9 You can copy paste static text objects for the text above the Analog Numeric Objects Di D11 9 3 Create Functions to Load and Save Recipes 10 Add a touch key by selecting M in the object palette and clicking in the block 11 The dialog for the key now opens Select Load recipe under Other functions in the dialog and type the text Load on
7. Object General Appearance Curves Font Dynamics r Curve 2 Dune 1 Analog signal co Lol Color Offset jo Signed 16 bit D Gain f Calculate Curve 3 Analog signal woj c Color Gain o D Curve 4 Analog signal wei Color fo Signed 16bt e Calculate Offset m Offset lo D Offset fo X Gain Calculate Gain f Calculate Curve 5 Curve 6 Analog signal woj c Color m Analog signal 0 woj c Color m 4 Click OK 5 Drag to resize and position the object as desired 7 1 Save the project and click the Play button gt to test run the project Test run the Project 18 Beijer Electronics MA00750A 8 Alarm Management We shall now create a function to generate an alarm 1 Select Functions Alarms The Alarms dialog now opens Click New Alarm and make the settings as shown in the figure Alarm Input Alarm text security door open aN signal mol yo o Alarm when Digital signal is On OFF Analog signal is Acknowledge notify Remote acknowledge Alarm group Info black Mail to address Ack required To printer L Repeat count 2 Type the alarm text Security door open This text will be shown in the alarm list Specify MO as the signal to generate the alarm 4 Click OK 5 End Alarms using Exit Beijer Electronics MA00750A 19 Alarm Management 8 1 Cr
8. ation of the software Beijer Electronics MA00750A 1 Contents Contents 10 11 E EE 4 NR 4 Installing and Starting the Program eee eeeeeeeeseeesneeeeneeeeneeeeeeens 5 SE HEEN ege 5 2 2 Installing the Configuration Tool 6 Aoo arane tne C Onipetiration Tool uenee a seundreuien ces eens 6 Creatitio a New E Dee Z Idec e 4 32 Open the E 8 SE EE 8 DAR WE 9 State ess MUA era a E setae mareen teeta 12 Creatine Jumps between Blocks iscosntcnciedooweeniieidaueteti eens 13 De ING EN 13 2 Open tite Main leckere ege eg 14 5 3 Create a Jump back to the Main Block A 14 Importing EE 15 Adding a Trend EE 17 Talk Test rUn CNC PrO CE e ET O 18 AA AAG EN e EA 19 8 1 Create a Jump back to the Alarm Block 20 8 2 Create E e ieai 20 E EE 21 Create a Recipe DIOCK EE 22 GE 24 EE 25 9 3 Create Functions to Load and Save Recpes 25 Report Ponton EE 27 10 1Print the Report leede ege geen eegen 28 E tee REDEE deen 29 Beijer Electronics MA00750A RN E 30 13 West thes r0 et esta cope hil aut ts ait n eieteaaelan A 31 Jee Bei Bian ener en dee 32 14 1 Data Exchange between Conrtoallers eee eeseesseeeeseeeeneeeeees 32 H Tie Terna RE 33 ee ER ee E 33 Beijer Electronics MA00750A Introduction 1 Introduction The Information Designer configuration tool is a software package for the development of projects for the CIMREX and EXTER operator terminals The HMI system is supplied with all the basic functions you could possibly need f
9. ct Manager various menus toolbars and object palettes are shown Beijer Electronics MA00750A 7 Creating a New Project 3 2 Open the Block Manager In the manual we will use the block manager as the starting point when creating our project Select View Block Manager to activate the block manager information Designer Projecti Fie Ese View Febers Zeta Bam Meager Preerct Transfer Weg ren Dee pn E A Sf zum B OT Hep E Eroi p E w C A sel 13 AR WS Alarms Time Channels System Monier DI mp Ro a SECHS Ve E z Si EXTER Buara EXTER Teuchioeys EXTER pages EXTER r cgiren EXTER Pecean EXTER Gegen CIMREX Peoceg CIHRENX Raye Al Feel A ISAT A r hbd redt E1 EXTER TAO Lindiaoe L k D DEMO 400 13 Gm ae A 3 3 Save the Project Save the project by clicking the diskette symbol or select File Save as Specify a name for the project and the save destination In this case name the project User_guide Finish by clicking Save 8 Beijer Electronics MA00750A 3 4 Add Object 1 Double click Main in the block manager The main block is opened 2 Select the Speedometer J object in the object palette and click in the block The properties dialog for the object now opens Speedometer General Appearance Font Dynamics Analog signal DO Lol EN Scale division 20 Scale ticks 10 Minimum value 0 Maximum value 100 Angle 300 Border style Engineering
10. eate a J ump to the Alarm Block The alarm block is a so called system block that already exists Create a jump to the alarm block by dragging an arrow in the block manager from the main block to the alarm block 8 2 Create an Object to Activate the Alarm In the main block we add a digital text object that will activate the alarm Select the object in the object palette and click in the main block Make the settings in the dialog as shown in the figure Digital Text General Appearance Font Access Dynamics Digital signal MO Text off Text on Alignment Border style Left None Center O Raised O Right Sunken Raised frame Sunken frame Text WI Background E Note In order to be able to maneuver the obj ect the Enable operator input function on the Access tab must be checked 20 Beijer Electronics MA00750A Alarm Management 8 3 Test run the Project Save the project and click the Play button gt to test run the project Beijer Electronics MA00750A 21 Create a Recipe Block 9 Create a Recipe Block This function is used to save the signal value from the controller in the block in question 1 Add a new block and name it Recipe 2 Add an analog numerical object and make the settings as shown in the figure Analog Numeric General Appearance Font Access Dynamics Analog signal Lol Ee Alignment Border style Engineering units scaling Gei Right
11. edometer changes Press Esc to end the simulator and return to the configuration tool 12 Beijer Electronics MAQ0750A 5 Creating Jumps between Blocks This chapter describes how to create jumps between the different blocks in the project 5 1 Adda Block 1 Right click in the block manager and select New Block Type a name for the block in this case Block1 and click OK The block is now opened Create New Block Block name Block Block number 1 Cancel Block type e Graphic oi C Text E 2 Press and hold the left mouse button with the pointer located in the main block in the block manager and drag an arrow to Block A jump is now created to the new block Block1 is now found in the block manager as shown Users_Guide cpacBlock Manaper Beijer Electronics MA00750A 13 Creating Jumps between Blocks 5 2 Open the Main Block 3 Double click the main block in the block manager A button has now been automatically created for a jump to Block1 5 3 Create a J ump back to the Main Block Create a jump back to the main block by dragging an arrow from Block to the main block in the block manager A button is now created in Block1 to implement the jump to the main block 14 Beijer Electronics MA00750A 6 Importing Symbols In this chapter we will add a symbol to Block 1 Double click on Block1 in the Block Manager 2 Select Symbol WW in the object palette and click the block The Sta
12. he F1 key 2 1 System Requirements Operating System Windows 2000 Professional Windows XP Professional Processor Pentium Il 266 MHz RAM 64 MB Free space on hard drive 100 MB Installed software Internet Explorer 5 0 or later The configuration tool ought to be used on a color monitor with more than 256 colors Beijer Electronics MA00750A 5 2 2 Installing the Configuration Tool The configuration tool is supplied on a CD The manuals can also be read from the CD The installation creates an icon for the configuration tool in the Information Designer program group 2 3 Starting the Configuration Tool Once the configuration tool is installed you can start it by selecting Information Designer under Start All Programs Information Designer The first time the configuration tool is started the Project Manager is shown together with certain toolbars LB A Boke TE fe BO es EE to EECH Bn CC a a D ie ic Wi EI d 6 Beijer Electronics MAQ0750A Creating a New Project 3 Creating a New Project 3 1 Select File New Select File New to create a new project Select Operator Terminal and Controller systems Click OK The project is named the first time it is saved Project Properties Operator Terminal EXTER 170 1 0 Controller systems Controller 1 Controller 2 Change Color scheme Current default When a new project is created a tree structure for the project Proje
13. ons build on 25 years of automation knowledge yet they handle industrial applications with everyday ease Used with simple intuition they set machines information and ideas in motion HMI Products is part of the Beijer Electronics group which is listed on the Stockholm Stock Exchange and based in Malm Sweden The group has subsidiaries in 10 countires in Asia Erope and North Ame rica as well as close relationships with OEMs brand label partners and distribution partners worldwide For the representative nearest you visit www beijerelectronics com FROM PERSON TO PROCESS HEAD OFFICE SWEDEN Beijer Electronics Products AB Box 426 201 24 Malmo Sweden Telephone 46 40 35 86 00 Fax 46 40 93 23 01 info beijerelectronics com SUBSIDIARIES GERMANY Beijer Electronics GmbH Zettachring 2A 705 67 Stuttgart Germany Telephone 49 711 327 599 0 Fax 49 711 327 599 10 info beij erelectronics de USA Beijer Electronics Inc 939 N Plum Grove Road Suite F Schaumburg IL 60173 USA Telephone 1 847 619 6068 Fax 1 847 619 6674 info usa beij erelectronics com BeiJer ELECTRONICS CHINA Beijer Electronics Co Ltd Room 201 Building B No 1618 Yishan Road Shanghai 201103 China Telephone 86 21 6145 0400 Fax 86 21 6145 0499 info beij erelectronics cn TAIWAN R O C Hitech Electronics Corp AF No 501 15 Chung Cheng Rd Shin Tien Taipei Shien Taiwan R O C Telephone 886 2 2218 36
14. or your application The functions are well tested and have been developed with customer needs and preferences in focus The configuration tool can be used to easily create a complete process im age with the aid of pre defined objects In this way it is easy to gain an overview of a complex application Users can also customize the pre defined objects or create their own Communication drivers for most controllers and automation equipment on the market are available 1 1 Manual Structure This manual is based on examples which makes it easy to get started with program development with Information Designer The idea behind the manual is that the reader follows the instructions from the start to finally produce a functioning project that can be further developed or used for ideas The examples are shown in an operator terminal with touch display It is assumed that the user has good knowledge of Windows and access to documentation for the Windows 2000 XP operating system For informa tion about the use of the configuration tool refer to the help files press F1 and the Reference Manual for EXTER 4 Beijer Electronics MA00750A Installing and Starting the Program 2 installing and Starting the Program For ease of use we recommend using a mouse with the configuration tool For keyboard commands refer to the manual for Windows 2000 XP Professional The help text for the current function in the program is obtained by pressing t
15. the Text tab 12 Finish by clicking OK Beijer Electronics MA00750A 25 13 Make another key for Save recipe Ss L 3 Ca a a RES fad Si During operation when you select Save a keyboard is shown in order to type the name of the recipe file 14 Finish by clicking OK 26 Beijer Electronics MA00750A 10 Report Printout In this chapter we will shall create a report printout to be printed on a connected printer 1 Create a new block of the Text type and name it Report 2 Type the desired report text For example Report Printout from EXTER 3 Add a digital object by selecting a digital text object in the object palette and clicking in the block 4 Connect it to the MO signal 5 Similarly add an analog numerical object and connect it to the M1 signal E Users_Guide cpa Text 4 Report 6 Close the block Beijer Electronics MA00750A 27 Report Printout 10 1 Print the Report Block Right click the report block in the block manager and select Properties The properties dialog for the block now opens Specify the M10 signal as Print signal on the Printout tab When M10 is activated the report will be printed on the connected printer Block Properties General Printout E Mail Print signal M10 Lol Completion signal Lol 28 Beijer Electronics MA00750A 11 1 O Cross Reference The I O Cross Reference function is used to show which signals are used
16. tic Symbol dialog opens Static Symbol General Dynamics C Use dynamic bitmaps Stretch eel Wd 3 Click Select The Select Symbol dialog opens 4 Click Browse 5 Find and select the desired symbol in this example Static Symbol2 bmp Beijer Electronics MA00750A 15 Importing Symbols 6 Click OK ELECTRONICS The Digital symbol and Multisymbol objects are added in the same way 16 Beijer Electronics MA00750A 7 Addinga Trend Object The trend function is used to store register information from the controller in the operator terminal We shall now add a trend object with two curves 1 Create a new block and name it Block2 2 Select the Trend Se object in the object palette and click in the block The trend dialog now opens General Appearance Curves Font Dynamics Name TREND Sampling Control Sample interval 00 00 1 ol Enable sampling signal Vol Sample count 100 Sample full limit O Erase samples signal Lol Sample full signal Lol m Y Scale Time scale Border style C OF Minimum value Time range 00 04 00 None Left Maximum value Division 00 02 00 Raised Right Division Ticks 00 00 30 C Sunken C Left Right Ticks GG Grid Scale CH Grid Oo Background Si 3 Type a name for the trend file in this example TREND and select the Curves tab Make the settings as shown in the figure Beijer Electronics MA00750A 17 Adding a Trend
17. units scaling Neede W wes Offset 0 Scale Raised Gain fy Sunken Background Calculate Show bar Cancel Apply Help 3 Type DO in the Analog signal field on the General tab 4 Click OK The object is now shown in the block Drag the handles to resize and position the object as desired Beijer Electronics MA00750A 9 Creating a New Project When for example adding objects or drawing graphics in the work area the Undo function in the Edit menu can be used 10 steps The keyboard shortcut Ctrl Z can also be used 5 Now add a slider by selecting the Slider HS object in the object palette and click in the block 6 Type DO in the Analog signal field on the General tab Note On the Access tab the Enable operator input function must be checked in order to be able to maneuver the object 7 Click OK 10 Beijer Electronics MA00750A General Appearance Font Access Dynamics Analog signal ag o z o sl Scale division Scale ticks Minimum value Maximum value Direction Engineering units scali G Up Offset RT Right Scale Beijer Electronics MA00750A 11 Starting the Simulator 4 Starting the Simulator The Simulator is used to test run the project on a personal computer Save the project and click the Play button gt or select Project Run Now a new window is shown acting as the operator terminal You can now drag the slider to see how the spe
Download Pdf Manuals
Related Search
Related Contents
PCAN-PCI - User Manual - PEAK Sony VAIO VGN-CS11S/W notebook Kyocera K612 Cell Phone User Manual Téléchargez le bilan carbone du site Sainte Savine Humax DMR-E55 User's Manual instrucciones de instalación, fu ncionamiento yma Silverstone SG03B-F DPF-WA700 Contenido - DR-HANK Copyright © All rights reserved.