Home
CMC-TC ISDN Unit Installation and operating instructions
Contents
1. vapours The unit must be installed in an enclosure rack to protect it from water and dust There must be no voltage across the CMC TC system when the CMC TC ISDN unit is connected to the PU The CMC TC ISDN unit must be properly installed in accordance with the separate installation instructions Page 4 RITTAL The conditions of use safety related guidelines listed in the instructions must be observed All warranty claims on the grounds of damage become void when this damage is incurred by failure to observe these instructions conditions of use or the instructions for the processing unit 7320 100 Rittal assumes no liability for consequential damage Rittal assumes no liability for any damage to property or bodily injury incurred by improper use or failure to observe the safety related guidelines Every warranty claim becomes void in such cases RITTAL 3 Description CMC TC ISDN Unit 7320 830 front RITTAL CMC TC ISDN unit The red green duo LED 1 indicates the current status of the ISDN unit The green LED 2 indicates the connection status of the ISDN unit LED Status Meaning 1 status LED red green red The ISDN unit is being initialised orange The ISDN unit is sending or receiving an SMS green The ISDN unit is ready 2 ISDN LED green off After activation the ISDN unit still has no ISDN access no terminal endpoint identifier TEI assigned brief flash The ISDN connector is in the
2. 2772 570126 ISDN Command Before an SMS can be sent over the fixed network the ISDN unit must be registered at an SMS centre This is necessary only when an SMS command is to be sent to the ISDN unit Receiving SMS alarm messages does not require registration The Deutsche Telekom SMS Centre requires an SMS containing the text ANMELD to be sent to the number 8888 Enter 8888 ANMELD in the ISDN Command field The ISDN unit then sends this message to the SMS centre When the ISDN unit is not to receive SMS messages any longer or is to be operated at another connector the 8888 ABMELD command sent to Deutsche Telekom cancels the registration Page 7 RITTAL Unit Messages When this option is enabled unit messages are also sent as SMSs e g timeout configuration change etc This SMS is sent to all destination numbers SMS Phone Number Here you can enter the destination call numbers that are to receive SMS messages sent by the ISDN unit Prefixing the destination call number by F the letter F followed by a blank causes the SMS to be sent over the fixed network Example F 027725052578 When the destination call number is entered without the prefix F the SMS will be sent to an SMS centre in accordance with the respective mobile network protocol Example 027725052578 The costs differ depending on whether an SMS is sent over the fixed network or via mobile network operators SMS Info This shows th
3. Ansicht Favoriten Extras e Q d amp Zur ck OATES Abbrechen Aktualisieren Startseite Suchen Favoriten Verlauf E Mail Drucken Adresse E http 130 0 2 218 Y Wechsen zu CMC TC 130 0 2 218 Name CMC TC Test Location FuE IT Herborn Contact info rittal de RITTAL Unit Name Serialnr Software 00001 V1 2 CMC TC DK 7320 100 1 2 3 4 Type Temperature Sensor Sensor Status 24 C OK e Status Message Text Temperature Sensor Setpoint High jo C Range 0 100 9 Setup Setpoint Warning 55 Range 0 100 Setpoint Low 10 C Range 0 100 C Alarm Relay C Disable Enable Alarm Beeper C Disable Enable Alarm Reset Auto C Manual Trap Receiver 1 2 MW 4Log Scheduled Alarm Off 11 2T 3T 4 Send SMS Format 1828384 Accept Reset RITTAL GmbH 2003 amp Fertig Internet Fig 5 Web browser configuration of sensors This browser window lets you configure the destination call number s an SMS is to be sent to on a status change the input format is 1828384 for all four destination call numbers 8 SMS mode 8 1 Sending SMSs Every sensor and output can be configured to send an SMS when its status changes The sensors and outputs can be configured via the Telnet menu Sensor Units gt Unit xyz gt Sensor abc gt Send SMS or your web browser Every sensor output must be assigned a specially formatted string e g 1 amp 2 amp 4 means that the SMS
4. for mobile communications providers that in addition to the network provider operate their own SMS service centre e g Debitel When the SMS service centre does not know that the SMS is to be sent to an SMS terminal in the fixed network the SMS is delivered as voice mail and cannot therefore be evaluated by the ISDN unit Further details can be taken from the following table The ISDN unit can send SMS messages to mobile phones independently of the mobile network and provider Page 15 sending SMSs from a mobile phone to the ISDN unit RITTAL in mobile phone Mobile phone Mobile phone Mobile in T D1 network in T D1 network mo le lo Mobile phone phone Vodafone D2 in e Plus contract with contract with in O2 i network network network provider service provider network Fixed network access Use default Enter T D1 Currently ae SMS SMS Centre Only voice mail is ee only voice i 4491710760000 491710760000 possible mail is SMS terminal ISDN unit bile oh possible ibl at Deutsche Telekom te di possis Fixed network access Send an SMS registered at Deutsche once from the Telekom AG or other fixed ISDN unit to the network provider Enter AnnyWay Enter AnnyWay mobile phone Currently SMS terminal ISDN unit SMS Centre SMS Centre voice malis only voice at AnnyWay 491722270333 491722270333 Enter for DESDE
5. is sent to the destination call numbers 1 2 and 4 The sent SMS has the following structure date time system ID and name unit name and number sensor output name status report e g Alarm too high low etc Page 14 RITTAL Example 28 02 2002 14 33 CMC TC Development Enclosure 1 01 Temperature sensor too high This SMS is sent to one or more destination call numbers These can be for mobile phones or any fixed network subscribers When no SMS terminal has been registered at the fixed network connector a special service D1 Service provides a digital voice to read out the SMS by telephone Please note that the processing unit can store maximum sixteen unsent SMS messages SMS messages are sent in the order they are received Bear in mind that each SMS takes about fifteen seconds to send When more than sixteen SMS messages are pending all further outgoing SMS messages will be deleted 8 2 Receiving SMSs When sending an SMS from a mobile phone to the ISDN unit note the following The SMS service centre entered in the mobile phone must know whether an SMS terminal has been registered for the destination call number This is the case when the mobile network provider is also the ISDN network provider e g T Mobile and Deutsche Telekom for providers operating both an SMS service centre in the GSM network and a fixed network SMS centre e g AnnyWay Dr Materna This is generally not the case
6. nonoperative state TEI assigned Layer 1 of the ISDN connector is deactivated slowly flashing 4 s ON 34 s OFF The ISDN connector is activated but the ISDN unit has not connected Layer 1 activated Layer 2 pending slowly flashing Ve s ON Ya s OFF The ISDN connector is activated but the ISDN unit has not connected Layer 1 activated and Layer 2 connected quickly flashing six times a second The ISDN unit is transferring an SMS or data Page 5 RITTAL 4 Description CMC TC ISDN Unit 7320 830 rear The provided RJ12 RJ12 connecting lead connects the ISDN unit to this RJ12 connector RS 232 interface on the processing unit This connecting lead functions as the 24 VDC supply and transfers data to and from the processing unit 2 The RJ45 ISDN connector is designed for connection to an ISDN connector The 24 VDC voltage connector is designed for future developments of the CMC TC system and is not needed for running the processing unit 5 Technical specifications Maximum power consumption 80 mA Maximum connecting lead length 4 m processing unit to ISDN unit Rated voltage 24 VDC with supply link from the processing unit Shock resistance 1 g Operating temperature range 5 C to 445 C Protection category IP 40 ISDN connector DSS1 Euro ISDN multi point interface Page 6 RITTAL 6 Commissioning Warning The following description applies to so
7. 888 Enter 8888 ANMELD in the ISDN Command field The ISDN unit then sends this message to the SMS centre The 8888 ABMELD command cancels the registration SMS Unit Messages When this option is enabled unit messages are also sent as SMSs e g timeout configuration change etc This SMS is sent to all destination numbers SMS Phone Number Here you can enter the destination call numbers that are to receive SMS messages sent by the ISDN unit Prefixing the destination call number by F the letter F followed by a blank causes the SMS to be sent over the fixed network Example F 027725052578 When the destination call number is entered without the prefix F the SMS will be sent to an SMS centre in accordance with the respective mobile network protocol Example 027725052578 The costs differ depending on whether an SMS is sent over the fixed network or via mobile network operators Page 10 en Terminal SHS Configuration PIN GSH Card SHS Service Number ISDN WSN ISDN Command SMS upon Unit Messages lt SHS Phone Numbers ESC End gt 1234 lt gt 491710760000 lt gt 4972772757012 lt Send SHS upon Unit Messages Timeout Fig 1 Telnet configuration of ISDN parameters IP Address 130 0 2 218 Router Gateway 6 6 6 6 Read Community public SysName CMC TC Test SysContact info rittal SysLocation FuE IT Herborn Software Version U1 21 Firmware U1 82 Se
8. C TC outputs can be activated and deactivated with the on and off functions Example SMS structure the following command switches ON output 4 of IO unit 3 at port 3 of the PU OUTPUT 3 4 ON on or off function Unit 1 4 output 1 4 the unit number the separator and the output number must be written together OUTPUT command Commands are case insensitive Single words can be separated with blanks with the exception of unit output c Fan control The fan of a climate unit can be controlled with the on and auto functions Example SMS structure the following command switches the climate unit fan at port 2 of the PU to auto fan control by the climate unit FAN 2 AUTO on or AUTO function Climate unit 1 4 FAN command Page 17 RITTAL Commands are case insensitive Single words can be separated with blanks Note For safety reasons the fan cannot be deactivated by SMS d Resetting the alarm The CLEAR command can be used to confirm a pending alarm Commands are case insensitive Page 18 Schaltschrank Systeme Industrial Enclosures Coffrets et armoires lectriques Kastsystemen Apparatskapssystem Armadi per quadri di comando Sistemas de armarios IOO 3p Stromverteilung Power Distribution Distribution de courant Stroomverdeling Str mf rdelning Distribuzione di corrente Distribuci n de c
9. CMC TC ISDN Unit DK 7320 830 FRIEDHELM LOH GROUP A31461 04 IT 74 RITTAL Table of Contents 39 XP am w ut 7 1 7 2 8 8 1 8 2 Page 1 ECSU EO m Pe 2 Conditions of use safety related guidelines 3 Description CMC TC ISDN Unit 7320 830 5 Description CMC TC ISDN Unit 7320 830 rear 6 SWC CINE ANIONS E 6 Sole NER 7 10 A 10 A PP e 13 SIS MOS M 14 Sending 5 55 14 o 15 RITTAL 1 Description Note For reasons of clarity these operating instructions cannot contain all detailed information nor can they take into account every conceivable case of installation operation and maintenance Specifications subject to alterations at any time The German wording shall apply in cases of doubt Accessories Processing Unit ISDN Unit 7320 830 PU 7320 100 as of software version 1 21 Optionally the ISDN unit can be supplied from a 24 VDC 80 mA power source connected here This is not RJ45 ISDN necessary when the PU is connected connector Connection cable RJ12 RJ12 provided The CMC TC ISDN unit can be used to configure a redundant transmission path or
10. e SMS messages when its status changes The relevant menu item is Send SMS The above example specifies that an SMS is to be sent to the destination call numbers 1 and 3 The destination call numbers must be separated with the character amp and must not contain blanks Page 12 7 2 Via browser The menu SMS Configuration lets you configure the system as described in the last section via your web browser as well The line SMS Info shows the current status see section Via Telnet 3 CMC TC Processing Unit Microsoft Internet Explorer Datei Bearbeiten Ansicht Favoriten Extras E E e gt a 3 Zur ck JONAS Abbrechen Aktualisieren Startseite Suchen Favoriten Verlauf E Mail Drucken Adresse amp http 7 130 0 2 218 m Wechseln zu CMC TC 130 0 2 218 Name CMC TC Test Location FuE IT Herborn Contact info rittal de E RITTAL Setup SMS Unit CMC TC m PIN GSM Card 1471 DK 7320 100 Service Center GSM 491710760000 ISDN MSN 49 2772 5701 26 ISDN Command Status Unit Messages No Yes Setup Phone Number1 027725052490 Phone Number 2 01 603683099 Phone Number 3 027725701 26 Phone Number 4 SMS Info ISDN unit o k Accept Reset O RITTAL GmbH 2003 o p Mme Fig 4 Web browser configuration of ISDN unit Page 13 3 CMC TC Processing Unit Microsoft Internet Explorer Datei Bearbeiten
11. e current status The ISDN unit can have the following statuses ISDN unit found ISDN unit was found ISDN unit o k ISDN unit was recognised and initialised ISDN connector is OK MSN missing No MSN was entered ISDN no Line No ISDN network available e g ISDN cable not connected no SMS unit found No SMS unit connected SMS unit timeout SMS unit disconnected from processing unit Receive SMS SMS received Every sensor and every output can be assigned a list of destination call numbers that an SMS is sent to every status change leads to an SMS message This list can be created via the menu item Sensor Units gt Unit xyz gt Sensor abc gt Send SMS Here you can enter a string consisting of a list of call numbers separated by the character 8 e g 1 amp 4 sends an SMS to the destination call numbers 1 and 4 when there is a change to the affected sensor status These entries can also be edited and readjusted after the first start up Notes on first start up The ISDN unit must not be connected until all details have been stored in the PU Please switch OFF the PU connect the ISDN unit and switch ON the power supply The CMC TC PU software polls the interface regularly for the presence of a device It may take up to a minute until the ISDN unit is found First the ISDN unit is initialised status LED lights up red When the ISDN unit connects to the network for the first time the ISDN LED flashes green cf page 4 O
12. ftware version 1 21 and higher for the processing unit DK 7320 100 needed to operate the ISDN unit Commissioning When several SMS terminals are operated on an ISDN bus each of these SMS terminals and therefore every ISDN unit as well must be assigned its own call number for sending and receiving SMSs Note The following must be observed before transferring SMSs over the fixed network This is necessary only when an SMS command is to be sent to the ISDN unit Receiving SMS alarm messages does not require registration Registering at a network provider requires that an SMS is sent once only to this provider for example for Deutsche Telekom the text ANMELD is sent to the call number 8888 See the section ISDN command below The following data must be entered before the ISDN unit is connected to the processing unit Mandatory data PIN GSM Card PINGSM Card a This field is not needed to configure the ISDN unit Service Center GSM 491710760000 7 E A Service Centre GSM Unit Messages No Yes This field is not needed to configure the ISDN unit Phone Number 1 027725052490 Phone Number 2 01 603683099 Phone Number 3 02772570126 Phone Number 4 SMS Info ISDN unit o k Reset RITTAL GmbH 2003 ISDN MSN The MSN multiple subscriber number is assigned by the network provider Also the country code and the local area code must be entered separated by 7 Example 49
13. mail is in mobile phone in mobile phone AnnyWay possible SMS Centre 49 1722270333 NOTICE When the system is to use AnnyWay the system must be reconfigured over a telephone link Our Centre will be pleased to assist you with further information Tel 49 0 2772 505 0 Tel 49 0 2772 505 25 8 The processing unit constantly checks whether the ISDN unit has received an SMS If so the SMS is analysed and the corresponding action initiated The SMS must have a certain format if the CMC TC is to act on it In addition the sender s telephone number is compared with the four numbers on the target telephone list The command is executed only when the sender s number is on the list Note For safety reasons the fan cannot be deactivated by SMS The Fan On command remains unchanged Page 16 RITTAL The CMC TC PU recognises the following commands a Door control This initiates the unlock lock and delay functions Example SMS structure the following command opens door 2 on access unit 1 at port 1 of the PU DOOR 1 2 UNLOCK unlock lock or delay function Unit 1 4 door 1 or 2 the unit number the separator f and the door number must be written together DOOR command Commands are case insensitive Single words can be separated with blanks with the exception of unit door b Outputs universal output power switch The CM
14. nce the ISDN unit has been initialised the system continually checks whether there has been a change to a sensor or output status When this sensor has been assigned one or more destination call numbers an SMS will be sent to these target addresses Page 8 RITTAL In addition the system checks whether an SMS has been received On detection of an SMS this is examined and when the syntax is correct the corresponding action initiated The system also checks whether the sender s phone number is on the list of destination call numbers The action is initiated only when this is the case The ISDN connection to the switching centre is constantly checked In the event of an error the status LED lights up red Page 9 RITTAL 7 Settings 7 1 Via Telnet The menu General configuration SMS configuration lets you enter the following values needed for the ISDN unit ISDN MSN The MSN multiple subscriber number is assigned by the network provider Also the country code and the local area code must be entered separated by Example 49 2772 570126 ISDN Command Before an SMS can be sent over the fixed network the ISDN unit must be registered at an SMS centre This is necessary only when an SMS command is to be sent to the ISDN unit Receiving SMS alarm messages does not require registration The Deutsche Telekom SMS Centre requires an SMS containing the text ANMELD to be sent to the number 8
15. orriente Elektronik Aufbau Systeme Electronic Packaging Electronique Electronic Packaging Systems Electronic Packaging Contenitori per elettronica Sistemas para la electr nica IVL2HbkH 22A 7 Z72A7A System Klimatisierung System Climate Control Climatisation Systeemklimatisering Systemklimatisering Soluzioni di climatizzazione Climatizaci n de sistemas REF ATA IT Solutions IT Solutions Solutions IT IT Solutions IT l sningar Soluzioni per IT Soluciones TI IT7Uai1 o2a 7 Communication Systems Communication Systems Armoires outdoor Outdoor behuizingen Communication Systems Soluzioni outdoor Sistemas de comunicaci n dqEa227 7a77A74A Rittal GmbH amp Co KG Postfach 1662 D 35726 Herborn Telefon 49 0 2772 505 0 Telefax 49 0 2772 505 2319 eMail info rittal de www rittal de Umschalten auf Perfektion RITTAL
16. rial Number 00002 CHC Info OK SHS Info ISDN unit ESC End Fig 2 View of ISDN info Subnetmask 255 255 0 0 HAC Address B818F 6366662 Write Community public Hardware Version U81 81 Manufacture Date 7 2664 The Telnet Info Page function lets you view the status of the ISDN unit view SMS Info The ISDN unit can adopt the following states ISDN unit found ISDN unit o k MSN missing ISDN no Line no SMS unit found SMS unit timeout Receive SMS Page 11 ISDN unit was found ISDN unit was recognised and initialised ISDN network is OK An MSN has not been entered see section Commissioning There is no ISDN network available e g ISDN cable not connected No SMS unit connected SMS unit disconnected from processing unit SMS received Verbinden Bearbeiten Terminal Temperature Sensor Status Value Setpoint High Setpoint Fan Setpoint Low Message Text Alarm Relay Beeper Trap Receiver Trap Receiver Trap Receiver Trap Receiver Alarm Reset Send SHS lt 1 2 3 4 5 6 7 8 9 A B C D E gt ESC End Index of Phone List e g ET gt 0K lt gt 24 C lt 65 C lt gt 35 C lt gt 10 C lt gt Temperature Sensor lt gt Enabled lt gt Enabled lt gt Enabled lt gt Enabled lt gt Enabled lt gt Enabled lt gt Auto lt 1 amp 3 Fig 3 Telnet configuration of sensor values Every sensor or actuator can be configured to send one or mor
17. w circumstances over a telephone link Our Centre will be pleased to assist you with further information Tel 49 0 2772 505 0 Tel 49 0 2772 505 2578 NOTICE When more than sixteen unsent messages have accumulated in the SMS memory all new outgoing messages will be deleted These deleted messages can be viewed in the processing unit via the web or FTP Also required Processing Unit 7320 100 2 Conditions of use safety related guidelines Page 3 The CMC TC ISDN unit must be used exclusively for the Rittal CMC TC system The following documents apply the operating instructions safety related guidelines for the processing unit 7320 100 and these product specific instructions In particular the conditions of use safety related guidelines and warranties listed in these documents must be observed It is imperative that all leads are connected separately from cables carrying the supply voltage The CMC TC ISDN unit must be used exclusively within the specified environmental limits The CMC TC ISDN unit must not be opened The unit does not contain any parts that need servicing Before connecting the CMC TC ISDN unit make sure that it is suitable for the processing unit oafety devices must not be deactivated It is imperative that the CMC TC ISDN unit does not come into direct contact with water e g dew oil or aggressive substances The unit must not be operated in environments subject to flammable gases or
18. when no network infrastructure is available for relaying alarm messages The alarm signal is sent as SMS The ISDN unit is connected to the serial interface on the processing unit 7320 100 The power supply is likewise achieved via the connection cable The device functions only with ISDN see ISDN access requirements Up to four destination call numbers may be set and allocated to the various events This variant of sending alarm messages can also be used in countries permitting SMS in fixed networks Moreover SMS can now be used over the fixed network to control switching outputs Power supply is via the processing unit Other functions where offered by the provider Fax e mail Voice mail ISDN access requirements DSS1 Euro ISDN Point to multipoint configuration ISDN So bus These minimum requirements must also be fulfilled when the ISDN unit is connected to a private branch exchange Page 2 RITTAL Important information NOTICE Only one of the tools ISDN unit GSM unit or display unit may be connected to a PU NOTICE When the ISDN unit is used the front interface RS 232 on the processing unit is deactivated e g Hyperterminal access The system can then be configured only via Telnet or the web When Hyperterminal was used before the ISDN unit is installed the user must have logged off correctly NOTICE When the system is used outside of Germany it must be reconfigured to the ne
Download Pdf Manuals
Related Search
Related Contents
Ego Technology 4000 Plus User's Manual Emerson ASCO 7000 User's Manual Surf Life Saving Australia Yamakawa MP-28 User's Manual IAN 91621 - Lidl Service Website Veri-Q カラードップラー - 医療機器製造販売の 日本ビー・エックス・アイ Manual de Instruções Absoluta En 2 Mots Manuel d`installation EcoStar 700 Copyright © All rights reserved.