1. 05683E00 Connecting field devices to the module NOTICE The mounting can be carried out with connected or disconnected terminal In the operating flap there is a insert label which can be used to enter the assignment of the field devices to the channels Labelling of the insert label can be performed for example by means of the IS Wizard gt Connect field devices to terminal X1 according to terminal assignment see on the front or on insert label under the operating flap tightening torque for screw type terminals 0 5 0 6 Nm Place the field wiring shields if present as close to the entry point on the grounding rail as possible Plug the pluggable terminal X1 into the module and secure it against loosening using safety screws tightening torque 0 5 0 6 Nm Mount partition if necessary distance between intrinsically safe and non intrinsically safe electric circuits at least 50 mm Analog Universal Module 218080 946860310020 HART for Zone 2 2013 01 18 BAO0 IIIl en 00 9468 33 Installation 9 4 LED indications and troubleshooting Meaning of the LEDs BBBBHBHHBEBRBHEBRH 15395E00 LED RUN green operation indication LED ERR red module error indication LED M S blue requires maintenance or outside specification Indicati
2. 4 wire operation each following channel 1 3 5 7 must be used for common connection 218080 946860310020 Analog Universal Module 5 2013 01 18 BA00 III en 00 HART for Zone 2 9468 33 Technical data In case of 4 wire operation the following information and restrictions apply Only for connection of maximum 4 galvanically separated unearthed intrinsically safe field circuits HART communication is not supported For use of earthed field circuits and or HART communication a device Type 9164 is required for each 2 wire channel safety related limiting values U Io Po C and L are negligible Maximum connectable safety characteristic values during operation with active 4 wire transmitters Max input voltage U V 28 28 28 28 28 7 Technical data Explosion protection Global IECEx Gas and dust Europe ATEX Gas and dust USA FM Certificates and approvals Certificates Further parameters Installation Safety data Max voltage U 2 wire input output Max current lo Max power P Max connectable inductance L capacity C IIC IIB 3 wire input Max current lo Max power Po Max connectable inductance L capacity Co IIC IIB Max internal capacity C Max internal inductance Li 6 Analog Universal Module HART for Zone 2 9468 33 Max input current Max ambient temperature l mA Tamb C 150 55 140 60 130 65 115 70 105 15 IECEx DEK 12 0054X Ex nA ia i
3. 3 8 53 23 0 370 2 0 59 10 0 430 ee 1 0 71 2 0 430 at ee 0 5 88 1 0 470 II TITIITITCDTTN lt 0 2 119 0 5 550 0 2 700 0 1 860 a ee lt 0 05 890 0 a m Wire input ircui V 24 4 V HART 3 Wire input output circuits oc Isc 81 8 mA Po 499mW CL I DIV 1 A B CL I DIV 1 C G Zone 0 GP IIC Zone 0 GP IIB IIIC A Fi La mH Ca nF La mH Ca nF 3 6 53 21 0 380 2 0 58 10 0 420 1 0 70 2 0 420 EA 0 5 87 1 0 470 lt 0 2 119 0 5 550 FM approved i p converters positioners indicators 0 2 700 0 1 860 lt 0 05 890 Wiring legend Connection allocation Analog Universal Module HART Type 9468 4 Wire input output circuits Vi 280V X1 2 Wire X1 3 Wire X1 4 Wire ss Ci negligibility Input Output Input Input Voc negligibility Li negligibility i Channel Terminals ig i in A a m a 5 ec 0 1 2 ly 1 2 4 o un ee amb ne er u i 130 mA at Tam lt 65 C common 4 li 1 15 mA at Tame lt 70 C J 3 40 Bene li 105 mA at Tamb lt 75 C 2 5 6 be an 6 7 signal 6 common 8 Noles gt ck a SEA 1 Intrinsically safe apparatus shall be an FM approved System or 10 en 4 Entity device connected in accordance with the manufacturer s gna 3 installation instructions TERES common 12 2 For Entity concept use the appropriate parameters from above to TALA ensure the following 6 13 14 su i I 2 4 Voc or Vi lt Vmax Ga Goa Gee Bee 160 Isc o
4. Operating instructions Analog Universal Module HART for Zone 2 gt 9468 33 Contents 1 2 1 2 2 2 3 Contents OODOOODNAMONARARAARWNNNN oR WN No A OON GNM ee mm m WN I OOO N BONES a en ne ne A 2 General HlOrmallON seen 2 Mandac EN ee een 2 Information regarding the operating instructions 02200220002n0 ann nnneenenenn 2 Conformity with standards and regulations 0222022200220 nen nenn nenn nennen 2 VMD AI SO ee E oralen 3 General safety NOLGS esse ee nt 3 Operating instructions storage u222u22suennnnenenennnnnnnnnnennnnnnnnnnnn ann nennen nenennnnnen 3 ye LS Vag oc nee ee ee ee 3 Alterations and modifications 0 0 eee cceccceecceceeeeeeee cece eeeeeeceueeseeeseeeseeeseeeseeeeaaeess 4 SPECIAL VERSIONS nase ernennen ne arena 4 IETS FV SUIS en amici eta E 4 OID OMG ee en er 5 VENIO anne een EEE Rear 5 Pluggable terminal X1 2220220020000000000 redda ner riie ann nenn anne anna nun anne anne nenne 5 TEENAGER ee 6 Transport and storage na er 9 AS AR ONE ee 9 Dimensions fastening dimensions ccccceccceecceeeeceeeeeeecececaeeeeeeeseeseeeseeeeaeeeas 9 H aaO NG OMGINOINS ae een een 9 Mounting and operating position u22022s02000nnn nenn nnnennnnnnnnnenenennennnenennneneen 10 LED indications and troubleshooting 2200240024002n0nnnnnne nennen nnn nenn nenn
5. 128 mm W 96 5 mm H 67 mm LED M S blue LED RUN green LED ERR red Manufacturer Type hardware revision software revision serial number e Internal bus error primer redundant e No response from IOM e Configuration does not correspond to the module e Hardware error e Excess temperature e Slot error e Module requires maintenance 0 signal disturbed 1 signal valid lt 2 4 mA lt 3 6 mA adjustable parameters at 4 20 mA gt 23 5 mA or gt 22 8 mA gt 21 mA adjustable parameters Terminal voltage gt 16 V response range 16 16 5 V or output current can no longer be set Output load lt 60 Q response range 40 60 Q horizontal or vertical on 35 mm DIN rail NS 35 15 DIN EN 60715 218080 946860310020 2013 01 18 BA00 III en 00 Transport and storage 8 Transport and storage Transport and storage are only permitted in the original packaging The devices must be stored in a dry place and vibration free 9 Installation 9 1 Dimensions fastening dimensions Dimensional drawings all dimensions in mm inches subject to modifications cool 7 ar co rod S LUD ph S N vt iui Ya IC c i E g on a p F RY e 3 8 128 mm 5 04 T ansannnnnnhan 01927E00 9 2 Installation conditions A WARNING The national installation instructions e g IEC EN 60079
6. be required If required contact your responsible distributor for further information gt Loosen safety screws of the pluggable terminal X1 Pull out the terminal from the module If required remove the partition Pull the blue notch lever of the module upwards to unlock the module Remove the module vertically from the BusRail Position the new module vertically onto the BusRail and snap into place by slightly pressing it If required snap partition into place between modules Plug the pluggable terminal X1 into the module and secure it against loosening tightening torque 0 5 0 6 Nm Analog Universal Module 218080 946860310020 HART for Zone 2 2013 01 18 BAO0 IIIl en 00 9468 33 Maintenance overhaul and repair 10 Maintenance overhaul and repair 10 1 Maintenance The module does not require regular maintenance Observe the function according to intended use Follow the directives according to IEC EN 60079 17 Adhere to permissible temperatures according to IEC EN 60079 0 NOTICE If the blue LED M S lights up continuously it is recommended to replace the module in the foreseeable future Otherwise there is a high probability that the module will fail in 12 months see LED indications and troubleshooting 10 2 Repair instructions NOTICE amp Repair must be performed by the manufacturer only When repair is required send the module to your responsible sales organi
7. due to live components This graphic marks important additional information tips and recommendations 4 General safety notes 4 1 Operating instructions storage Read these operating instructions carefully and store them near the installation place For correct operation please observe all other documents enclosed in this delivery and the operating instructions of the equipment to be connected 4 2 Safety notes WARNING Use the devices only for their intended purpose We cannot be held liable for damage caused by incorrect or unauthorized use or by non compliance with these operating instructions Use the device only if it is undamaged and clean WARNING Any unauthorized work on the device is prohibited Installation maintenance overhaul and repair may only be carried out by authorized and appropriately trained personnel Observe the following information during installation and operation Any damage can invalidate the explosion protection National and local safety regulations National and local accident prevention regulations National and local assembly and installation regulations Generally recognized technical regulations Safety notes in these operating instructions Characteristic values and rated operating conditions on the rating plates and data plates Additional information plates on the devices 218080 946860310020 2013 01 18 BA00 IIl en 00 Analog Universal Modul
8. lie contents to others without expressed authorization is prohibited Offenders fhe grant of a pofent ulldy madel or ornamental design regisiralion F 4830 503 G zugestanden Zuwiderhandlungen verpflichten zu Schadenersatz Alle Rechte f r den Fall der Potenterteilung oder GM Eintragung vorbehalten Weitergabe sowie Vervielf ltigung dieser Unterlage Verwertung und Mittellung ihres Inhalte nicht gestattet sowelt nicht ausdr cklich The IS1 resp IS1 Remote I O is a DIN rail mounted system designed ane u A TT to record and output process control signals between hazardous i EHL location transducers and sensors and a nonhazardous location nee automation system It consists of electrical apparatus in the nonhazardous Class I Division 2 or Class I Zone 2 hazardous Fieldbus Isolating locations linked by either nonincendive field bus or a field bus installed if 9185 12 Repeater per the National Electrical Code ANSI NFPA 70 Article 500 Interface conector Nonhazardous Eseston The nonincendive field bus circuit is achieved with the use of the mn aan Fieldbus Isolating repeater type 9185 This device resides in the zu o nonhazardo
9. 0310020 2013 01 18 BA00 III en 00 8 each with adjustable parameters as input or output 16 V at 20 mA 0 20 mA 4 20 mA HART protocol 0 mA 23 5 mA 22 8 mA 4 20 mA 23 5 mA 0 20 mA Filter time constant adjustable parameters small medium 50 Hz 60 Hz Resolution in the range 14 75 bit 14 75 bit 14 75 bit 4 20 mA with HART 12 75 bit Maximum delay from 32 ms 120 ms 500 ms signal internal bus 40 ms 24 mA 22 8 mA 4 20 mA 23 5 mA 0 20 mA 14 1 Q 750 Q at 20 mA 700 Q at 21 8 mA EN 60079 11 gt 1500 V AC gt 500 V AC gt 500 V AC gt 500 V AC Tested to the following standards and regulations EN 61326 1 2006 IEC 61000 4 1 6 NAMUR NE 21 BusRail Types 9494 Pluggable blue terminals 16 pole 2 5 mm screw or spring type versions with lock Intrinsically safe Ex ia via IS1 BusRail 220 mA at 20 mA per channel 5 3 W at 20 mA per channel 3 7 W at 20 mA 500 per channel 2 7 W at 20 mA per channel Analog Universal Module 7 HART for Zone 2 9468 33 Technical data Device specific data Settings Module Diagnostics message Signal filter Scan HART live list Signal Signal type Signal range Measuring range input Line fault monitoring Behaviour in case of error Cyclic transmission of HART variables Accuracy of measurement Ambient temperature influence Note Ambient conditions Ambient temperature Storage temperature M
10. 075 of 4 wire transmitters to active 2 wire inputs and for the galvanic separation Input sink Ex Output sink Ex i Labelling strips FB Addr Mod No for pluggable terminal 162788 0 001 sheet with 26 strips 05869E00 DIN A4 sheet For label plate on I O modules 6 labels on each sheet 162832 0 001 print out using IS Wizard packaging unit 20 sheets 09900E00 Partition For mounting between intrinsically safe and 220101 0 000 non intrinsically safe connections of the I O modules in order to adhere to the required 50 mm distance 15196E00 Warning sign 1 Clean modules only with a damp cloth 162796 0 001 ge EEE ean Pa 05872E00 14 Analog Universal Module 218080 946860310020 HART for Zone 2 9468 33 2013 01 18 BA00 III en 00 EC Declaration of Conformity 13 EC Declaration of Conformity EG Konformitatserklarung EC Declaration of Conformity D claration de Conformit CE R STAHL Schaltgerate GmbH Am Bahnhof 30 74638 Waldenburg Germany erklart in alleiniger Verantwortung declares in its sole responsibility d clare sous sa seule responsabilit dass das Produkt Analog Universal Modul HART that the product Analog Universal Module HART que le produit Module analogique universel HART Typ en type s type s 9468 3b 08 1f b 2 3 f 0 1 mit den Anforderungen der folgenden Richtlinien und Normen bereinstimmt is in conformity with the requirements of the foll
11. 14 must be observed Ensure that there is a distance of at least 50 mm safety distance between connecting units of intrinsically safe and non intrinsically safe circuits A WARNING If the installation has strong electromagnetic sources of interference use of shielded field cables is recommended In this case the shield must be connected to the equipotential bonding of the hazardous area For this purpose the shields of the field wiring must be connected to the shield busses installed in the enclosure as close to the entry point as possible The shield busses must be also connected to the mounting plate close to the entry point of the field wiring using the shortest possible way 218080 946860310020 2013 01 18 BA00 III en 00 Analog Universal Module 9 HART for Zone 2 9468 33 Installation 9 3 Mounting and operating position Mounting the module on BusRail NOTICE tae module and pluggable terminal X1 can be safely connected or 10 disconnected during operation in a hazardous area hot swap NOTICE amp Module operation is permitted only in the following mounting positions Vertical mounting with pluggable terminal below on the left or right 5 7 BusRail I BusRail m o Ps mur fm Cy N s 8 A Ih 22200000000 00000 N Position the module vertically on the provided slot of the BusRail Snap module into place by slightly pressing it
12. a Ga IIC T4 Gc Ex ia Da IIIC DEKRA 12 ATEX0173 X Il 3 1 G Ex nA ia ia Ga IIC T4 Gc x II 1 D Ex ia Da IIIC in preparation IECEx ATEX in Zone 2 Zone 21 Zone 22 and in the safe area 24 4 V 80 mA 488 mW Lo mH 3 8 2 1 0 5 0 2 C nF 53 59 71 88 119 Lo mH 23 10 2 1 0 5 0 2 Co nF 370 430 430 470 550 700 81 8 mA 499 mW Lo mH 3 6 2 1 0 5 0 2 C nF 53 58 70 87 119 Lo mH 21 10 2 1 0 5 0 2 C nF 380 420 420 470 550 700 negligible negligible 0 1 860 0 1 860 0 05 890 0 05 890 218080 946860310020 2013 01 18 BA00 III en 00 Technical data Electrical data Ex i inputs outputs Number of channels Supply voltage for 2 wire transmitter Nominal signal range Digital communication Min signal Max signal For inputs For outputs Signal transmission Transient response output 10 90 Max short circuit current For inputs For outputs Max input resistance for each channel Max load resistance output Galvanic separation Test voltage acc to standard Between auxiliary power system components Between two I O modules Between I O channels system components Between I O channels ground PA Electromagnetic compatibility Electrical connection Power supply Ex i field signals Auxiliary power Version Max current consumption Max power consumption Max power dissipation Only outputs Only inputs 218080 94686
13. aximum relative humidity Semi sinusoidal shock IEC EN 60068 2 27 Sinusoidal vibration IEC EN 60068 2 6 Mechanical data Degree of protection IEC 60529 Module enclosure Fire resistance UL 94 Pollutant class Dimensions Indication LED indication Module requires maintenance Operating state Group error Function indication Retrievable parameters Error indication Module status and alarms Signal errors for each channel Signal status bit Wire breakage input Short circuit input Wire breakage output Short circuit output Mounting installation Mounting orientation Mounting type Analog Universal Module HART for Zone 2 9468 33 ON OFF small medium big 50 Hz large 60 Hz ON OFF Input output 0 20mA 4 20 mA 2 4 22 8 or 23 5 mA 3 6 21 mA acc to NAMUR ON OFF Input 10 0 100 110 alarm code hold last value Output 10 0 100 110 hold last value no 4HV 8HV Error of small medium 50 Hz 60 Hz measurement with filter time constant Maximum error of 0 075 0 05 0 05 measurement 12 uA at 4 20 mA f 8 A at 4 20 mA 8 UA at 4 20 mA lt 0 03 10K All values in of the signal span at 23 C 40 75 C 40 80 C 95 without condensation 15 g 3 shocks per axis and direction 1 g in the frequency range 10 500 Hz 2 g in the frequency range 45 100 Hz IP20 polyamide 6GF V2 corresponds to G3 L
14. e 11 Dismounting replacement of the module 002200220002n0nnnnennnenenenenenenenen 12 Maintenance Overhaul and repair ccceccecceceecceeeeeeeeeceeceeseeseeeeeeseeseeteeeneenees 13 MAINE DANCE eee ee hee ee 13 RED SIF IK eo ee en 13 BIS OS AN SEE SE ERE es 13 Accessories and spare parts cccecceccescceeceeceeeseeceeeeeeceeceeceeaueeeesseeceeseeeeeeseeeaes 14 EC Declaration of Conformity u2220022002000 0000 nenn nano nnnennnennnn TEETER 15 General information Manufacturer R STAHL Schaltger te GmbH Am Bahnhof 30 74638 Waldenburg Germany Phone 49 7942 943 0 Fax 49 7942 943 4333 Internet www stahl ex com Information regarding the operating instructions ID No 218080 946860310020 Publication code 2013 01 18 BA00 IIl en 00 Conformity with standards and regulations Conformity with standards and regulations is specified in the corresponding certificates and the EC Declaration of Conformity These documents can be downloaded from our homepage www stahl ex com Analog Universal Module 218080 946860310020 HART for Zone 2 2013 01 18 BAO0 IIIl en 00 9468 33 Symbols used 3 Symbols used Safety notes Non compliance can result in material damage serious injuries or death The safety notes contained in these operating instructions and affixed to the device must be observed Warning symbol Danger due to explosive atmosphere Warning symbol Danger
15. e 3 HART for Zone 2 9468 33 Intended use 4 3 4 4 Additional safety notes The analog universal module HART Type 9468 33 is approved for use in gas hazardous areas of Zone 2 and in the safe area The analog universal module HART Type 9468 33 is approved for use in dust hazardous areas of Zone 21 and Zone 22 For operation in gas or dust hazardous areas the module must be installed in an enclosure which fulfills the requirements of IEC EN 60079 0 The module must be mounted on the BusRail 9494 only A distance of 50 mm must be maintained between intrinsically safe and non intrinsically safe electric circuits Modules with intrinsically safe and non intrinsically safe field circuits may be operated simultaneously on one BusRail In this case a distance of 50 mm must be maintained between the terminals of intrinsically safe and non intrinsically safe electric circuits e g partition 220101 or empty space The safety related maximum values of the connected field devices must match the values of the modules according to data sheet operating instructions or EC type examination certificate Interconnections of several active intrinsically safe circuits can result in different safety related maximum values This can endanger the intrinsic safety so that an appropriate proof must be provided Modules and plug connectors may be connected and disconnected during operation in hazardous areas hot swap und hot p
16. lug To avoid electrostatic charging the modules in hazardous areas must be cleaned only with a moist cloth Alterations and modifications A WARNING Alterations and modifications to the device are not permitted We shall not accept any liability or warranty obligations for damage resulting from alterations and modifications Special versions In case of additional different order options special versions may differ from the description given here Intended use The analog universal module HART is used for connecting of up to 8 intrinsically safe analog standard signals 0 4 20 mA to the IS1 remote I O system The digital communication with connected field devices can take place bidirectionally via the HART protocol Each channel can be parameterised as input for connecting 2 wire transmitters including transmitter supply or as output for connecting positioners or indicators The Ex i inputs and outputs are short circuit proof and galvanically separated from the system Compatible spare for IS1 I O modules Series 9460 12 9461 12 9465 12 and 9466 12 for operation with active 4 wire HART transmitters a 9164 is additionally required for each channel Analog Universal Module 218080 946860310020 HART for Zone 2 2013 01 18 BAO0 IIl en 00 9468 33 Components 6 Components 6 1 Overview 1 Operating flap with insert label open and connection diagram 2 Module data serial number hardware revisio
17. n e Activate the cyclic data transfer with the automation system Module is defective e Replace the module Normal operation eo Ambient temperature is outside the specification e Reduce ambient temperature by means of e g shading or cooling Note If the problem is not eliminated the module will be permanently damaged Slot error or module is damaged by excess temperature or end of the service life reached e Replace the module as soon as possible within the next 12 months otherwise there is a risk of module failure Analog Universal Module HART for Zone 2 9468 33 11 Installation 9 5 Dismounting replacement of the module 12 A ee A WARNING If a partition is mounted first pull out terminal X1 from the module to be replaced NOTICE When replacing the module by a module identical in construction the set parameters are maintained No further user adjustments are necessary When replacing the module by a module with a different function the module reports a configuration error red LED ERR flashes The module must be either re parameterised or it is necessary to connect a module of the right type lf an IS1 module is replaced by an IS1 module with the same functions the 151 module functions in the compatibility mode identical functionality If new IS1 functions must be used it may be necessary to update the software of CPM 9440 or CPU 9441 In case of PROFIBUS DP operation anew GSD may
18. n number software revision number manufacturing date e g 123456DE9999 Rev A 01 01 0508 Notch lever for removing the module from the BusRail LED for operation indication RUN green error ERR red and maintenance M S blue for further information see LED indications and troubleshooting 5 Pluggable terminal X1 with two safety screws 15323E00 6 2 Pluggable terminal X1 For the module a pluggable terminal X1 screw type terminal 162702 or spring clamp terminal 162695 for connection of field devices is available as accessory not included in the scope of delivery of the module The pluggable terminal X1 has 16 terminals for connection of the field cables X1 OOOOOOOOOOOOOOOO 9 10 11 12 13 14 15 r Q 4 20 mA HART 15324E00 Terminal assignment X1 X1 X1 2 wire input output with HART 3 wire input with HART 4 wire input Channel Terminals Terminals Terminals 0 1 2 3 4 5 6 7 1 2 supply 1 signal 2 common 4 2 4 3 4 EEE 5 6 supply 5 signal 6 common 8 6 8 7 8 oo d ern 10 supply 9 signal 10 common 12 10 12 En EEE E supply 13 signal 14 common 16 14 16 Ea 16 NOTICE 87 The channels have no common connection to earth among themselves NOTICE Mixed operation of 2 wire 3 wire 4 wire is permissible In case of 3 and
19. on control systems with DIV 2 Zone 2 Installation of IS1 resp IS1 Remote I O System RS 232 Fieldbus Isolating 2 BusBail P Repeater Type The BusRail provides a Power bus an internal data bus and the gigo address lines for the interconnection of the CPU amp Power Supply RS 232 to RS 485 to Remote I O modules The Power bus distributes power supplied oi PA by the CPU amp Power Module to the I O Modules plugged to the Location BusRail The communication with the I O Modules is implemented via the address and date bus lines The interface of the CPU amp Nonincendive fieldbus Power Module with the internal data bus on the BusRail is designed with redundancy a 3 Components of Remote I O System Me nz All O Modules are manufactured in a unique DIN rail mount Division 2 package which then mounts onto the Remote I O system BusRail Zone 2 All I O Modules provide galvanic isolation between the field circuits and the BusRail s circuits Service Bus with Isolating Repeater interface 4 Refer to pages 3 through 26 for information specific to each module GENERAL NOTES 1 Installation should be in accordance with Article 504 505 of the National Electrical Code ANSI NFPA 70 and ANSI ISA RP12 06 01 resp with the Canadian Electrical Code Part I Mounting direction upwards 2 Use a general purpose enclosure meeting the
20. on overview Module state LED RUN green ON FLASHES In standby switched on but no data exchange with master yet OFF No function LED ERR red Incorrectly configured module Configuration is not correct or a wrong module is connected OFF FLASHES External error Outputs in safety position ON Module error LED M S blue OFF FLASHES External maintenance required ON Maintenance required 218080 946860310020 2013 01 18 BAO00 IIl en 00 Possible solution Normal operation ei The module is in proper condition but is not ready for cyclic data exchange yet Error source e Activate the cyclic data transfer with the master e Check master bus connection and CPM there is no parameter set available yet Outputs in a state without power No supply voltage at the e Check system supply I O module or I O module is e Check CPM or CPU amp PM defective e Check the BusRail e Engage the I O module correctly on the BusRail e Replace the I O module No error b e Eliminate the cause in the indicated field circuit check electric lines and field device Error in the field circuit wire breakage short circuit measuring range exceeded not reached e Change configuration in the automation system or connect the right module Cyclic data transfer with the automation system has been interrupted e Check the cyclic data transfer of CPM or CPU LCD or LED RUN e Check bus connectio
21. owing directives and standards est conforme aux exigences des directives et des normes suivantes 94 9 EG ATEX Richtlinie EN 60079 0 2012 94 9 EC ATEX Directive EN 60079 11 2012 94 9 CE Directive ATEX EN 60079 15 2010 Kennzeichnung fiir marking for marquage pour II 2 1 G Ex ia ia Ga IIC T4 Gb PET amp ii 1 D Ex ia Da iic CE 0168 Kennzeichnung fiir marking for marquage pour amp 113 1 G Ex nA ia ia Ga IIC T4 Ge Cenc EG Baumusterpr fbescheinigung DEKRA 12 ATEX 0173 X EC Type Examination Certificate DEKRA Certification B V Attestation d examen CE de type Utrechtseweg 310 6812 AR Amhem The Netherlands 2004 108 EG EMV Richtlinie 2004 108 EC EMC Directive EN 61326 1 2006 2004 108 CE Directive CEM Sonstige Normen EN 50178 1997 Other Standards EN 61010 1 2010 Autres normes Waldenburg 07 02 2013 Ort und Datum M Kaiser Place and date Leiter Zertifizierung Produkte Leiter Qualit tsmanagement Lieu et date Automatisierung Director Quality Management Head of Certification Products Automation Directeur Assurance de Qualit Directeur Certification Produits Automation F 4174 601 01 2011 STMZ 9468 6 002 001 0_00 Analog Universal Module 15 HART for Zone 2 9468 33 218080 946860310020 2013 01 18 BAO00 IIl en 00 wit be held table for the payment of damages All rights reserved in the event of The copying distribution and ufdization of this document os well as fhe communication of
22. r li lt Imax L gt Li Eissas 3 Suitable separation must be maintained between wiring of each 7 15 16 l S input channel 4 Suitable separation must be maintained between non l S AEx nA wiring of the input circuits and I S wiring of other I O modules WARNING Sib tiftitionof components may impar Infunsic and of the IS1 resp IS1 system Use partition SAP No 220101 for separation from I O modules with I S circuits Do not carry out Safety work at the terminals without the partition plate in place AVERTISSEMENT Substitution de composants peut 5 General Notes see Page 1 P 2 compromettre la s curit intrins que The safety relevant statements of this document may be transferred into the operafing instructions Transferring the text editorial changes of equivalent meaning are allowed 00 2013 Date Name Certification crowing Sale f oram 08 02 Reiste Analog Universal Module HART ene o feel Kaiser Type 9468 3b 08 1 b 2 or 3 Sheel ee a FE 13 of 30 e end STAHL jie 02 26 02 2014 Bagusc 9400 6 031 002 1
23. requirements of Se aa ANSI ISA S82 for use in nonhazardous or Class Division 2 D hazardous Classified Locations 3 Use an FMRC Approved or NRTL listed Dust ignition proof enclosure appropriate for environment protection in Class Il Division 1 Groups E F and G and Class Ill hazardous Classified Locations 4 All O Modules may be detached from the BusRail or plugged onto it during operation in hazardous areas 5 The Modules may be operated in one of the three mounting positions only BusRail 1 o000000000000000 The safety relevant statements of this document may be transferred into the operating instructions Transferring the text editorial changes of equivalent meaning are allowed 00 f2013 Date Name Certification crowing Sale none prawn 108 02 Reiste o ete Kaiser for CL I DIV 2 Zone 2 Sheet o ee ee Overview 1 of 30 ee n s 02 26 02 20 agusc or fread Beach BUN 9 ast RUE IS1 resp IS1 Remote I O System wit be held table for the payment of damages All rights reserved in the event of The copying distribution and ufsization of this document os well as fhe communication fhe grant of a pofenf ulldy model or ornamental de
24. sign registralior of ite contents to ofhers without expressed authorization is prohibited Offenders F 4830 503 G zugestanden Zuwiderhandlungen verpflichten zu Schadenersatz Alle Rechte f r den Fall der Potenterteilung oder GM Eintragung vorbehalten Weitergabe sowie Vervielf ltigung dieser Unterlage Verwertung und Mittellung Ihres Inhalte nicht gestattet sowelt nicht ausdr cklich Nonhazardous The Type 9468 Analog Universal Module HART is designed to receive Class I Il Ill Division 2 Group A G a digital output from the IS1 CPU amp Power Module and output a or Class I Zone 2 Group IIC IIB corresponding analog signal to positioners loop distance etc It is Hazardous Classified Locations also designed to input analog signals from a hazardous location transmitter and output a representative digital signal for processing by the IS1 CPU amp Power Module The module is nonincendive for installation in a Class Il Ill Division 2 Group A G or Class I Zone 2 j Group IIC IIB hazardous location according to NEC Article 504 505 and provides intrinsically safe connections for the hazardous locations f listed below f Entity parameters for wiring configuration to the left are as follows C0 Sc Rk N a PEPE PEPE FE FI FI FT IR 2 Wire input output circuits Voc 24 4V j 2 5 sc 80mA Po 488 mW CL DIV 1 A B CL I DIV 1 C G Zone 0 GP IIC Zone 0 GP IIB IIIC La mH Ca nF La mH Ca nF
25. us location and provides a nonincendive field bus circuit nu i es for connection to the IS1 resp IS1 Remote I O System See example ALE to the left The apparatus located in the Division 2 or Zone 2 hazardous location are referred to as Remote I O and consist of the following major Division subsystems Division 1 1 CPU amp Power Module or CPU Module Power Module amp Socket a The CPU amp Power Module or the Power Module serves as a power supply unit for its CPU unit or the CPU Module as well as for the supply to the I O Modules and the field circuits The power supply to the I O modules is implemented via the BusRail For the configuration with a redundant CPU and Power Module the power supply to the I O modules is decoupled with diodes The power supply unit has an under voltage monitoring circuit The CPU fulfils the function of a gateway between the internal bus of an IS1 field station and the fieldbus which connects the field station with ea the automation system The gateway is constructed as a dual ee E E processor system The I O processor controls the data exchange package used for commissioning trouble with the I O modules and when plugged in with the redundant u nn CPU amp Power Module The communication processor controls the data exchange on the fieldbus and on the Service Bus Example System Topology interfacing Automati
26. zation for the address see chapter 2 1 11 Disposal Observe the national waste disposal regulations 218080 946860310020 2013 01 18 BA00 III en 00 Analog Universal Module 13 HART for Zone 2 9468 33 Accessories and spare parts 12 Accessories and spare parts WARNING Explosion hazard due to wrong or insufficient spare parts or wrong accessories For components with relevant Ex protection use only suitable certified spare parts or corresponding accessories of R STAHL Schaltgerate GmbH or other manufacturers Otherwise explosion protection cannot be guaranteed any longer R STAHL Schaltgerate GmbH cannot be held liable for damage caused by ignoring this danger Designation Figure Description Art no Weight kg Plug in terminal _ lt lt 2 5 mm with lock 16 pole screw connector blue 162702 0 028 for connecting the field signals to I O modules for intrinsically safe field circuits Labelling 1 16 02079E00 2 5 mm with lock 16 pole spring clamp connection 162695 0 028 blue for connecting the field signals to I O modules for intrinsically safe field circuits incl test jacks Labelling 1 16 02077E00 mA Isolating The mA isolating repeaters are used for the connection 160166 0 107 Repeater of 4 wire transmitters to active 2 wire inputs and for the galvanic separation Input sink Ex e Output sink Ex i The mA isolating repeaters are used for the connection 160165 0