Betriebs- anleitung Operating Instructions Notice d
Contents
1. 25S 40S 55S 70S 95S 110S lke IF 880807 Warmlufterzeuger Space Heater G n rateur d air chaud Betriebs Operating Notice anleitung Instructions d utilisation C 0085 DIN EN 150 8951 amp Ki amp EN S Stand Juli 2008 029127 01 Inhaltsverzeichnis Grundlegende Hinweise 2 Bestimmungsgem e Verwendung 3 Grundlegende Sicherheitshinweise 4 bersicht a ns 6 Technische Daten T Inbeirtebnahbme seen 8 E ie Un e EEN 10 eu e nenne 12 POGASS eee 13 Schaltplan 25S 40S 55S 70S 14 Schaltplan 70S ab 200 Pa 15 Einzelteile 25S bis oo 16 Einzelteile 95S und 110S 18 Einzelteile Brenner 25S bis 55S 20 Einzelteile Brenner 70S a a anananananannanann 21 Einzelteile Brenner 95S und 110S 22 St rungen und Abhilfe AAA 23 EG Konformit tserkl rung 26 Garantieanforderung 27 ACCESSOIRES suisses 31 Grundlegende Hinweise Kroll Warmlufterzeuger 25S bis 110S sind das Ergebnis jahrzehntelanger Erfahrung und intensiver Entwicklungsarbeit wir sind berzeugt Ihnen ein Spitzenerzeug nis zu bergeben Trotzdem m ssen die Heizger te den je weiligen Gegebenheiten entsprechend von einem Fachmann installiert in Betrieb ge nommen und durch Messungen berpr ft werden Betriebsanl
2. u kabel R1V Ca Gegenstecker 7 polig Plug 7terminals Prise 7 poles 022373 006605 Buchsenteil 7 polig Jack 7 terminals Prise femelle 7poles 022374 006623 Steuerger t Unterteil Lower part of control Socle de coffret 006868 006868 box Steuerger t Relais 006942 028697 lammenw chter Photo electric cell Cellule photo lectrique 005891 005933 QE A upplung f r Motor Coupling for motor Accouplement pour 005896 005896 moteur Ma Dimension Dim Magnetventil Solenoid valve Electrovanne 005897 005897 sion A 5mm 25S 13 Pumpe Pompe 006094 006094 11 mm 40S 3 3 E 16 mm 55S Schlauchnippel Hose nipple Raccord de flexible 022377 022377 lschlauch 600mmlang Oil pipe 600 mm Flexibles 600 mm 022647 022647 lschlauch 1200 mm lang Oil pipe 1200 mm Flexibles 1200 mm 005898 005898 Druckrohrnippel Pressure tube nipple Nipple du tube de 022380 022380 19 pression Druckrohr Pressure tube 003990 003990 005652 022388 005901 028167 005894 005895 005653 028207 022383 022391 022384 003834 005468 005892 005508 005656 005656 005655 005655 A 12 Tube de pression 20 z otor Motor 90W Moteur 90W 1 Transformateur d allumage Z ndtransformator Transformer 22 Haube komplett Burner top Capot de br leur 2 Ventilatorrad Fan wheel Roue de ventilateur Carter avec tube de 3 24 Geh use mit Brennerrohr Housing with burner tube combustion Pumpensieb f r Suntec Strainer for sunt
3. un thermostat RY di d ambiance enlever le shunt entre 2 2 kW 5 et 6 3 0 kW un ARS TEE E E E EE EES Leer B2 L fterthermostat B2 Thermostat fan B2 Thermostat ventilateur PATIENTS B3 Sicherheitstemperatur B3 Overheat thermostat Bi Limiteur de temp rature ea ID ISIN Meee 8 irae Eeer ehre B4 Brennerthermostat B4 Burner thermostat B4 Thermostat du br leur F1 Steuersicherung F1 Fuse F1 Fusible F2 Motorschutzrelais F2 Motor protection relay F2 Relais t le de capotage H1 St rlampe H1 Indicator light H1 Lampe de d rangement K1 Motorsch tz K1 Contactor K1 Contacteur M1 L ftermotor M1 Motor ventilation M1 Moteur entilateur S1 Wahlschalter M1 Selector switch M1 Commutateur H Thermokontakt L ftermotor He Thermojunction fan He Contact thermique moteur falls vorhanden motor if available ventilateur si existant Or TENTE Te ANE EENEG EE ai X2 Brennerstecker X2 Burner plug X2 Prise du br leur ER A CT TE CA EE Control box de commande 15 Einzelteile 25 S bis 70 S Component part 25S to 70S Nomenclature 25S jusqu a 70S 25 S bis 70S 32 Schaltgehause Control box Boitier de commande 027946 01 Verschlu schraube Screw plug Vis de fermeture 023204 Signalleuchte rot Signal lamp red Lampe t moin rouge 006501 Sicherheitstempera Overheat thermostat 049289 turbegrenzer Limiteur de temp rature Nockenschalter Snap switch Combinateur cames 028307 Kabe
4. 95 S 025217 030835 028913 110 S 027866 028909 028913 029228 028911 027853 005256 001314 001773 011563 028835 029228 028911 027853 005256 001314 001773 011563 028835 028840 027853 005256 028915 030837 028905 030835 025217 028902 028913 028840 027853 005256 028915 028910 028905 028909 027866 028902 028913 028914 030825 006019 004197 029682 005673 029683 028900 029915 029914 005690 028906 027004 027599 028914 028898 006019 004197 031348 005673 029683 028900 029915 029914 005690 028906 027004 027599 028593 006224 028912 035265 01 028901 028593 005535 028912 035265 01 028901 028541 028541 028908 005498 030833 030825 028914 026814 005256 028902 028908 027866 028907 028898 028914 026814 005256 028902 19 Brenner R1 Burner R1 Br leur R1 Kroll Brennereinstellung Burner adjustment Reglage de br leur Kesselanschluss Boiler connection Raccordement de chaudi re 1 Stauscheibe mit Zwillings Flame ring Acchroche flamme avec 006092 005364 elektrode with twin electrode lectrodes double Zwillingelektrode Electrodes double 005904 005905 3 D se Nozzle Gicleur auf Anfrage auf Anfrage on request on request sur demande sur demande Z ndkabel Ignition cable C ble d allumage 022369 028699 5 D senstock mit lvor Nozzle connection Ligne gicleur 022371 028700 w rmer with oil preheater avec pr chauffage
5. Vorgehensweise wie Heizen mit Raumthermostat Heizen ohne Raumthermostat 5 Wahlschalter auf 5 Heizen stellen Der Warmlufterzeuger wird aufgeheizt Bei 40 C Werkseinstellung Gerateinnen tem peratur wird das Geblase in Betrieb gesetzt Nach Uberschreitung bzw Unter schreitung der eingestellten Temperatur Werkseinstel lung 80 C schaltet der Temperaturwachter den Brenner ab bzw wieder ein Abschalten mit ohne Raumthermostat Wahlschalter auf 0 stellen Ein mehrmaliges Anlaufen des Gebl ses dient zur Abf hrung der im Warm lufterzeugers verbliebenen Rest und Stauw rme A Das Gebl se mu Brennkammer und W rmetauscher abk hlen Uberhit zungsgefahr Erst nach Abk hlung des Warmlufter zeugers Strom und Hauptschalter abschalten Zuwiderhandlung schlie t Werksga rantie aus L ften 7 Wahlschalter auf 3 Liften stellen Das Geblase lauft ohne Brenner im Dauerbetrieb fur die Raumbeluftung Vorhandenen Raumthermostat auf 0 C stellen The space heater and burner are controlled by the selector switch and by means of a room thermostat or via control for week program AN Power connection The electric connection of the machine must be done by authorized personnel according to DINEN 50 156 1 VDE0116 1 2005 3 and DINEN 60 335 1 VDE0700 1 Heating with room thermostat N Set selector switch to Heating 2 Set the desired room temperature The space heater heats up When intern
6. any technical damage before the appleance is assembled and set into operation The heater is only be started up after competent repair Any cases of consequential damage due to the failure of the space heaters during operation will be excluded from liability Domaine d application Par tout ou la chaleur est n cessit e ou pour la maintenance hors gel ou pour la climat agr able les g n rateur dar chaud Kroll sont les partenaires ideales le chauffage d entrep ts chauffage des places de travail dans de grand halls d usine et des ateliers le chauffage de serres pour montage et la r paration N Inad quat traitement Ces g nerateurs d air chaud ne sont pas adapt aux emplois m nagers et ne doivent tre utilis s que par des personnes introduites en leur fonctione ment Responsabilit La garantie ne peut tre accord e que si l appareil a t mont et mise en marche selon les r gles de l art par un technicien Le relev des r glages doit tre d montr dans un proc s ecrit de mesure Remplir correctement tous les points de la demande de garantie la signer et renvoyer aux Ets Kroll Noter Qu en cas de valeurs mesur es manquantes les documents de garantie ne pourrant tre dress s L acceptation de la garantie suppose un entretien r gulier conform ment aux instruc tions de la maison Kroll qui doit tre effectu une fois par an et d montr par des proc s cerbaux de mesure y relat
7. at the air pressure controller LGW 10A2 instellwert iroi A Attention Please note the following points when you choose the burner the burner must be CE approved the burner control must have a prepurge periode of at least 30 seconds the burner control must be phase sensitive the air pressure switch on the burner has to be adjusted so that in case of lack of combustion air the burner is shut off before the amount of CO in the fluegasses reaches 1000 ppm for natural gas the CO range must be 9 10 for propane butane the CO range must be 10 11 the burner must be suitable for the dimensions of the combustion chamber of the appliance the heat input of the burner must be equal or must be adjusted to the heat input value on the type plate of the appliance Quand les br leurs gaz Giersch sont mise en service veuilleuz r gler les valeurs suivantes au manostat d air LGW 10A2 Setting R glage 110 S Nach Einregulierung des Brenners berpr fen dass bei Drosselung des Luftansaugs der Brenner abschaltet bevor der CO Gehalt im trockenen unverd nnten Abgas 1000 ppm berschreitet Gegebenenfalls den Einstellwert des Luftdruckw chters korrigieren Bei anderen Fabrikaten ist auf gleiche Art und Weise vorzugehen After adjustment of the burner please check that it automatically stops when the aspiration of air is reduced It must stop before the CO concentration in the dry ne
8. c Belt drive loose if indirect drive b Check main switch and fuses Replace fan Check capacitor eck motor protector switc Check belt drive e heater is connected at electric sup a No electrical supply a eck electrical supply ply but does not operate b has interrupt b Replace fuses Open electric control box and press reset button at motor protection relay In case of repeat the motor hat to be ignal lamp at control box is on a Motor protection relay has interrupt mecanically and electrically by a specialist Les pannes et les moyens d y rem dier Attention Tous travaux sur l installation lectrique ne doivent tre r alis s que par des lectriciens sp cialis s Retirer la prise d alimentation du secteur seulement lorsque l appareil est compl tement refroidi Voir galement les directives de service de br leur fuel ou gaz Le g n rateur dar chaud est branche mais le br leur ne d marre pas lorsque le commutateur est sur position chauffage Le g n rateur dar chaud est branch et a mise en marche Le br leur fuel d marre et se met en securit aussit t le br leur gaz d marre et se met en s curit D clenchement du limiteur de temp ra ture D clenchement constant du limiteur de temp rature a b c d Pas de courant Commutateur d fectueux Br leur fuel gaz est en d range ment Limiteur de temp rature est en s curit Mauvais
9. means of an adapter pipe Si l appareil est op r avec du gaz le tuyau de chemin e doit tre mis dans le manchon de chemin e paar un adapteur bersicht Overal view Sch ma d ensemble 40S 55S 70S 95S 110S rolf Deckel Cover Capot Luftlenkjalousie stirnseitig ass Air outlet louvre front side SCHEER San Luftlenkjalousie rechts L i t EEN NS LL re Air outlet louvre right amelles orientables c t frontal EE tease sssessess E E Lamelles orientables Luftlenkjalousie links a a droit Air outlet louvre left feel Lamelles orientables gauche R ckwand Rear panel Paroi arri re Abdeckwand Cover Seitenwand Couverture ide pane Paroi lat rale Vorderwand Front panel Brennerplatte Burner flange Bride du br leur Paroi frontale l Gasbrenner Oil gasburner Br leur fuel gaz Umluftwand l ngsseitig Side recirculating panel Paroi lat rale air de circu lation Entst rknopf Brenner Reset button for burner Bouton de rearmement pour br leur Wahlschalter Selector switch Umluftwand hinten Commutateur recirculating rear panel Paroi arri re air de circula tion Entst rknopf Sicherheits temperatur begrenzer Reset button overheat thermostat Bouton de rearmement Vorderwand unten EL ront panel down limiteur de temperature paroi frontale en bas St rlampe Brenner Indicator light burner Lampe de derangement br leur Schaltgeh use C
10. retenue l interieur de l appareil Le ventilateur doit refroidir la chambre A de combustion et l changeur de cha leur danger de surchauffe ll faut attendre le refroidissment com plet du g n rateur dar chaud avant de couper l interrupteur principal et l alimentation lectrique Un non respect de ces indicati ons exclut l acception de garantie d usine Ventilation 7 R gler le commutateur sur position gt Ventilation Le ventilateur tourne sans br leur en fonctionnement en continu pour l a ration du local S il y a thermostat d ambiance le r gler sur 0 C Heizen mit Raumthermostat Heating with room thermostat Chauffage avec thermostat d ambiance Heizen mit Tag und Nachtautomatik Heating with day night mecha nism Chauffage avec jour m canisme de nuit Heizen ohne Raumthermostat Heating without room thermo stat Chauffage sans thermostat d ambiance Abschalten Switching off Arr t L ften Ventilation Ventilation Wartung Servicing Entretien Der W rmetauscher und die Brennkammer sollten nach DIN 4794 mind einmal pro Jahr gr ndlich gereinigt und durch einen Fachkun digen gepr ft werden Die Firma Kroll empfiehlt einen Wartungsver trag abzuschlie en A Bei allen Arbeiten am Warmlufter zeuger Wahlschalter auf 0 stellen Nach Abk hlung des Warmlufterzeu gers unbedingt Strom Hauptschalter abschalten Reinigung Brennkammer Strom abscha
11. the burner with 4 clamping screws on the burner bracket 2 Cleaning of heat exchanger suction side Turn off electrical supply see above After have removing the corresponding front panel loosen the cleaning cover remove the seal and clean by means of brush and aspirator Put on new seals and mount in reversed order 3 Cleaning of heat exchanger air outlet side Turn off electrical supply see above After having removed the corresponding side panesl loosen the cleaning cover remove the seal and clean by means of brush and aspirator Then put on new seals and mount in reversed order Kroi Conform ment la norme DIN 4794 l changeur de chaleur et chambre de combustion doivent tre nettoy s fond et v rifi s au moins une fois par un sp cialiste La soci t Kroll conseille de souscrire un contract d entretien Lors de tous travaux sur le g n ra teur d air chaud il faut positionner le commutateur sur 0 Apr s refroi dissement du g n rateur d air chaud il faut absolutement d brancher l interrupteur general A Nettoyage de la chambre de combustion Debrancher le courant lectrique voir ci dessus D sserer les 4 vis de fixation a la bride du br leur et enlever le br leur Par l ouverte nettoyer la chambre de combustion l aide d une brosse et d un aspirateur Fixer le br leur avec les 4 vis de serra ge la bride du br leur 2 Nettoyer d c
12. 3209 r Feinsicherung T5A Miniature fuse 5TA Fusible pour faible 006723 intensit T5A S Sch tz Contactor 023371 Motorschutzrelais Motorprotection relaiy Relais du protection moteur 029293 Kabelverschraubung Cable screw Raccord de c ble 023158 Temperaturregler Temperature regulator R gulateur de temp rature 049290 Aufbauwinkel Assembly bracket Jarret de montage 035266 i Einzelteile Component parts Luftlenkjalousie Air outlet louvre Strahlenschutz Seiten Protective screen wand side panel Wirbulator Turbulator Turbulateur Nomenclature Lamelles orientables Paroi lat rale Manteau int rieur paroi lat rale Couvercle 16 Reinigungsdeckel Cleaning cover REES 8 Zentriering Centring ring 5 oucrugssinuns Seal i Combustion chamber Chambre de combus tion benens Seo 14 Rear panel Paroi arriere Lamelles orientables wand side panel paroi laterale Pied pour ventilateur Gegenflansch tion chamber de combustion Protective screen Manteau interieur Control box Paroi frontale en 38 Vorderwand unten Front panel below dessous 39 Halteblech Mounting support Support Steuerger t control box bo tier de commande Lamelles orientables 45 Cleaning cover 46 Recirculating panel Couvercle de nettoyage Joint Tendeur Centrage Bo tier de commande T le de chicane de dar Couvercle de nettoyage Joint Paroi de reprise d air d Bestell Nr Requisition number Num ro de commande
13. 63 005499 005498 028061 028078 028095 028042 028065 028082 028099 028046 027818 027890 027904 027841 028065 028082 028099 028046 026386 026386 026386 026386 028593 028593 028593 028593 027485 005784 027487 027488 028064 028081 028098 028045 028052 028070 028087 028034 028541 028541 028541 028541 028718 028672 028719 028632 027229 027230 027263 026366 005256 005256 005256 005256 028056 028071 028088 028036 Kroi 17 Einzelteile 95S und 110S Component part 95S and 1108 Nomenclature 95S et 110S RE Loire EE CR em ee a N Se ee SE BE SE SE E Ge BEIGE EE HE Sa gt Position 37 Schaltgeh use nn Position 37 Boitier de commande Kabelverschraubung Cable screw Raccord de c ble 022993 Signalleuchte rot Signal lamp red Lampe t moin rouge 006501 Sicherheitstempera turbe Overheat thermostat Limiteur de temperature 049289 grenzer Nockenschalter Snap switch 028307 Schaltgeh usedeckel Control box cover Couvercle boitier 035267 de commande Gegenmutter Locking corner 023208 Temperaturw chter Overheat thermostat ontr leur de temperature 049291 Zugfederklemme gr n gelb Connecting strip green Barre bornes 025453 yellow verte jaune Zugfederklemme blau Connecting strip blue Barre bornes blue 025451 n Zugfederklemme grau Connecting strip grey 025452 Brennerkabel mit Stecker Burner cable with plug C ble du br leur avec prise 029251 Gegenmutter Locking corner 02
14. EWG Gasverbrauchseinrichtungen gas consuming appliances installation consumant du gaz Die Bauart der Maschine Construction of the device Type de construction de la machine 25S 40S 55S 70S 95S 110S Warmlufterzeuger ohne Brenner Air heater without burner G n rateur d air chaud sans br leur Product ID Nr CE 0085BS5025 Hiermit erkl ren wir dass die nachfolgend bezeichnete Maschine aufgrund ihrer Konzeption und Bauart in der von uns in Verkehr gebrachten Ausf hrung den einschl gigen grundlegenden Sicherheitsanforderungen der EG Richtlinien entspricht Bei einer nicht mit uns abgestimmten nderung der Maschine verliert diese Erkl rung ihre G ltigkeit We herewith declare that the below mentioned machines correspond on the base of their conception and their type of construction in the version brought into the market through our company to the relevant basic securitiy restrictions of the EC In case of any modification of the device that has not been agreed with us this declaration becomes void Nous declarons ainsi que les machines sous mentionnes corr spondent sur la base de leur conception et le type de construction dans la version dans laquelle ils sont lanc s sur le march par notre soci t aux restrictions de s curit de base appliquables de la CE En cas de modification qui n est pas convenue avec nous cette d claration est p rim e Folgende Normen sind angewandt DIN EN 13842 2004 The following
15. O Menge im Abgas 1000 ppm erreicht bei Betrieb mit Erdgas der CO2 Gehalt auf 9 10Vol eingestellt ist bei Betrieb mit Flussiggas der CO 2 Gehalt auf 10 11Vol eingestellt ist der Brenner f r die Gr e der Brennerkammer ausgelegt ist die eingestellte Nennwarme belastung mit dem auf dem Typenschild angegebenen Wert des entsprechenden Gerates bereinstimmt Bei Inbetriebnahme der Gasbrenner Fabrikat Giersch sind folgende Werte am Luftdruckw chter LGW 10A2 einzustellen A Attention Veuillez respecter les points suivants quand vous choisissez le br leur le br zleur doit tre test CE Si vous choisissez un br leur gaz le temps de pr enl vement doit tre au moins 30 sec le boitier de commande doit tre sensible a la phase l interrupteur pour la pression d air doit tre r gl d un mani re le br leur arr te avant que quantit CO dans les gaz fum es atteint 1000 ppm sile br leur marche avec du gaz naturel la concentration du CO doit tre r gl 9 10vol sile br leur marche avec du gaz p trole liquefi la concentration du CO doit tre r gl 9 10vol le br leur doit correspondre avec la largeur de la chambre de combustion la puissance calorifique maximale r gl e doit tre la m me que la valeur indiqu e sur la plaque de l appareil correspondant When the Giersch gas burners are put into operation the follwoing values have to be set
16. RT ee Bere Ss EEE EE EEE DD ON LE eene T T B2 L fterthermostat B2 Thermostat fan B2 Thermostat ventilateur B3 SE B3 Overheat thermostat B3 Limiteur de temp rature RE EE B4 Brennerthermostat B4 Burner thermostat B4 Thermostat du br leur C1 Motorenkondensator C1 Capacitor for motor C1 Condensateur pour moteur H1 St rlampe H1 Indicator light H1 Lampe de d rangement M1 L ftermotor M1 Fan motor M1 Moteur ventilateur S1 Wahlschalter S1 Selector switch S1 Commutateur TK1 Thermokontakt TK1 Thermojunction TK1 Contact X1 Feuerungsautomatik X1 Burner control X1 monies AWON ANGLE EE EE X2 Brennerstecker X2 Burner plug X2 Prise du br leur X3 Klemmleiste Schaltgeh use X3 Connecting strip en Barre bornes bo tier Control box 2 De commande Schaltplan Circuit diagram Sch ma lectrique f r 400 V Motoren for 400 V Motors pour 400V Moteurs er Bl lt 2 GL et tte Scie Sie Zuleitung mm em nn oe en oe mmm em emm em om gp oe em emm am ee dm ee ee zm zm Kl N gt i X3 i ENEA AEE i N H1 SAIT WEE j o g Bei Anschlu eines Raumthermo F1 D 8 8 su states Br cke zwischen u L1 L2 13 coe ja 1 Klemme 5 und 6 entfernen K1 lt bate nb an ke S1 SA Remove bridge connector 5 6 FZLELIE LE Rep when room thermostat is connected 1 5kW 3 6A i S 96 98 2 2kW 5 2A 3 0kW 6 6A i Pour raccordement d
17. al temperature of the appliance reaches 40 C factory setting the fan is set into operation The burner switches off when the set room temperature is reached The bur ner is automatically switched on again when the room temperature falls below this value Heating with day night mechanism 3 Instal control for week program accor ding technical manual when follow as if 4 heating with room thermostat Heating without room thermostat 5 Set selector switch to Heating The space heater heats up When internal temperature of the appliance reaches 40 C factory setting the fan is set into operation If the set temperature factory setting 80 C is exceeded or if the temperature falls be low this level the temperature controller switches the burner off or on again as the case may be Turning off with without room thermostat Set selector switch to 0 The fan will repeatedly start up in order to remove residual heat from the space heater A The fan must cool the combustion chamber and heat exchanger danger of over heating Do not switch off electrical supply and master switch until the space heater has cooled down Non compliance invalidates the factory guarantee Ventilation 7 Set selector switch to Ventilation The fan runs continuously with the burner for the room ventilation In cas of a room thermostat set to 0 C Kroll La commande du generateur d air chaud et du br leur s ef
18. alsely set No oil in the tank Air in fuel circuit Oil filter clogged Stopcock closed Oil burner indicates a malfunction again No gas pressure Temperature controller wrongly set a Fan does not start b Fuel flow rate too high c Recirculating air grille or air filter d inlet may be blocked if existing as accessories Check main switch and fuses Replace selector switch Reset oil gasburner if burner cuts again press reset button after 4 to 5 min See operating instruction for burner Press reset button of overheat thermostat Check room thermostat setting Refill oil tank Check screwed connections of fuel circuit for leaks Change filter element Open stopcock See operating instructions oil burner Check manometer admission pres sure Check if main shut off valve are in the open position Check temperature controller set ting Check fan motor or capacitor or replace it if necessary eventual check motor protector switch and belt drive Adjust fuel flow rate to given value Clean or exchange recirculating air grille respectively air filter ignal lamp at control box is on a Burner indicates malfunction a See operation instruction burner The fan does not start when the selector switch is set to Ventilation Version 400 V The fan does not start when the selector switch is set to Ventilation a b c No electrical supply Defective fan Capacitor defective a b
19. at flue gas exceeds 1000 ppm If necessary correct the set value of the air pressure controller The same procedure has to be applied with other brands Apr s r glage du br leur veuillez contr ler qu il arr te automatiquement quand l aspiration dar est r duite Le br leur doit arr ter avant que la concentration du CO dans les gaz fum es secs non dilu s d passe 1000 ppm Si n cessaire veuillez corriger la valeur r gl e du manostat d air La m me proc dure doit tre appliqu e avec d autres marques Storungen und Abhilfe H wi Vorsicht Alle Arbeiten an der elektrischen Anlage durfen nur von einer Elektrofachkraft durchgefuhrt werden Hauptschalter erst abschalten wenn das Ger t abgek hlt ist Siehe auch Betriebsanleitung des Ol bzw Gasbrenners Der Warmlufterzeuger ist angeschlossen Kein Strom vorhanden Hauptschalter und Sicherungen jedoch berpr fen Brenner startet nicht wenn der Wahlschalter defekt Wahlschalter austauschen Wahlschalter auf Heizen gestellt wird Ol Gasbrenner zeigt St rungen Ol Gasbrenner entst ren bei erneuter St rabschaltung nach 4 bis 5 Minuten Entst rknopf noch mals dr cken siehe auch Betriebs anleitung Brenner Sicherheitstemperaturbegrenzer ist Entst rknopf Sicherheitstemperatur verriegelt begrenzer eindr cken Raumthermostat auf Einstellung Raumthermostat falsch eingestellt berpr fen Der Warmlufterzeuger ist angeschlossen Kein Heiz l im Tank He
20. carried out by a qualified gas fitter Check gas supply and connection for leaks Adjust burner to local conditions Check electrical connection before setting into use a Oil connection The connection will made by the burner service Gas connection Oil or gas burner The adjustment and setting into operation may only be carried out by the after sales service of the respective burner manufacturer or an authorized specialist firm The values given by the burner manufacturer must be complied with a Burner service Kroll recommends taking out a service contract Trou Suspendre le g n rateur d air chaud a Installation uniquement contre des parois incombustibles et selon norme DIN 4794 partie 5 b de niveau c Lors de l installation du g n rateur dar chaud il faut observer les prescritions et les normes en vigueur DVGW Dans le cas d une mise en place en dessous du niveau du sol il faudra se mettre en conformit avec la norme TRF 1988 AN Raccordement lectrique La connection lectrique de l appareil doit tre fait par du personnel autoris selon DINEN 50 156 1 VDE0116 1 2005 3 and DINEN GO 335 1 VDE0700 1 Fa Thermostat d ambiance Montage a une endroit approprie hors de port e d un courant d air froit ou chaud a Raccordement gaz Le raccordement doit se faire selon les nor mes techniques en vigueur Raccordement est mise en service ne doivent amp tre effectues q
21. clature 95S et 1108S 18 Nomenclature br leur 25S jusqu a 55S 20 Nomenclature br leur 70S 21 Nomenclature br leur 95S et 1108S 22 Les pannes et les moyens d y remedier 25 D claration de confomet CE 26 Demande de garantie KREE 28 Accessoires 10 cccccecececececcececececececucunaeaeaees 30 Instructions de base Les g n rateurs d air chaud 25S 110S son le r sultat des d cennier d exp rience et de d velopement intense Nous sommes convalincus de transmettre un produit de haute qualit N ans moins le chauffage doit tre install mise en route et t st en mesurant conform ment aux circonsstance respectives par un sp cialiste Livre attentivement les instruc tions de service avant le monta ge et la mise en Tous details mentonnes concernant l instal lation et la mise en route doivent tre et observ s seignieusement pour assurer le fonctionnement conique et sans pannes Le g n rateur d air chaud sont prouvr selon DINEN 1020 13842 et doit tre quip d un bo tier d allumage lectrique qui est admettre dans le g n rateur d chaud Edition 880809 No du dessin 029127 01 Toute modification r serv e dans le but d am lioration du produit Droit du fabricateur St Kroll GmbH Bestimmungsgem e Verwendung Designated use Designation Kroi berall in folgenden Einsat
22. ec Tamis pour suntec pompe Pumpe pump Pumpensieb f r Eckerle Strainer for eckerle Tamis pour eckerle D Pumpe pump pompe Brenner R20 Burner R20 Br leur R20 roll Brennereinstellung Burner adjustment Reglage de br leur Ma Dimension Dimension C mm 95S 110S Kesselanschluss Boiler connection Raccordement de chaudi re 1 Stauscheibe mit Zwillings Flame ring Acchroche flamme 005364 elektrode Zwillingelektrode Electrodes double 005905 3 Duse Nozzle Gicleur auf Anfrage on request sur deman de D senstock mit Olvorwar Nozzle connection Ligne gicleur Ma Dimension Dimen mer u kabel R1V with oil preheater avec pr chauffage sion Te ers from S Roese vonta os s Severerat Unerei towerparofeonvelbox seee come oo o ES CT fres 77 Geh use mit Brennerrohr 26 Housing with burner tube Carter avec tube de com 022383 bustion Brennerflansch R1 Brunerflange Bride de br leur 006237 SE Seal fange 005508 En Pumpensieb f r Suntec Strainer for suntec pump Tamis pour suntec pompe 005656 Pumpe 21 22 A Achtung Bei der Auswahl der Brenner ist dar auf zu achten dass der Brenner CE gepr ft ist bei der Auswahl der Gasbrenner darauf geachtet wird dass die Vorspulzeit mind 30 Sekunden betragt der Gasfeuerungsautomat phasenempfindlich ist der Luftdruckschalter so eingestellt ist bei Verbrennungs luftmangel der Brenner ausschaltet bevor die C
23. eitung vor Aufstel A lung und Inbetriebnahme sorg faltig lesen Alle in der Betriebsanleitung beschriebenen Einzelheiten bez glich der Aufstellung und Inbetriebnahme m ssen sorgf ltig durch gef hrt und beachtet werden um einen st rungsfreien und energiesparenden Betrieb zu gew hrleisten Die Warmlufterzeuger sind nach DINEN 1020 13842 gepr ft und m ssen mit einem Feuerungsautomaten ausge r stet sein der f r den Warmlufterzeuger zugelassen ist Ausgabe 880809 Zeichnungs Nr 029127 01 Technische nderungen im Sinne der Pro duktverbesserung vorbehalten Urheberrecht und Hersteller Firma Kroll GmbH Contents Basic Instructions 2 Designated use nennen nennen 3 Securtiy instructions 4 Overal view ceeneeneenssneensnnennnnnennnnnennnnn nennen 6 Technical data 7 Setting into operation 8 SEI VICING sr 10 le Din d Le ae rm 12 Exhaust Tumes 13 Circuit diagram 25S 40S 55S 70S 14 Circuit diagram 70S up to 200 Pa 15 Component parts 25S to 70S 16 Einzelteile 95S and 110S 18 Component parts burner 25S to 55S 20 Component parts burner 70S 21 Component parts burner 95S and 110S 22 Malfunction and remedy 24 EC Conformity a 26 Guarantee request 28 ACCOSSOINCS wcccicsssscanccnsauncsnsee
24. es ainsi que la temp rature d air chaud de sortie montent A ration Pour la combustion il faut assurer un apport d air frais suffisant eviter une d pression dans le local Suffisament d air est assur quand par exemple le volume de la pi ce en m correspond au minimum 10fois la charge calorifique nominale en kW de tous les appareils qui fonctionnent dans cette pi ce Assurer une circulation normale de l air par les fen tres et les portes Si l on ne peut pas viter une d pression ou de la poussiere dans l air ambiant il faut alimenter le br leur en air ext rieur l aide d un coffrage Attention Ne placer pas le g n rateur dar chaud sur mat riaux combustible Pour libre circulation de l air il faut veiller laisser un cartement de 1 m autour de l appareil l exeption de raccordement conduit pression Signaler par un panneau Veuillez respecter un cartement de 1 m autour de l appareil Zone prot g e un paroi d aspiration Il faut attendre le refroidisse ment complet du g n rateur d air chaud avant couper l inter rupteur principal et l alimenta tion lectrique Un non respect de ces indica tionsexclut l acceptation de ga rantie usine LA uns Whey weal ch cy iroi Gasbetrieb muss das Abgasrohr mittels eines Adapterrohrs in den Abgasstutzen des Ger ts gesteckt werden Whe run with gas the flue pipe must be put into the flue outlet by
25. fectue par le commutateur et le thermostat d ambiance ou par le control nuit jour AN Raccordement lectrique La connection lectrique de l appareil doit tre fait par du personnel autoris selon DINEN 50 156 1 VDE0116 1 2005 3 et DINEN 60 335 1 VDE0700 1 Chauffage avec thermostat d ambiance 1 Regler le commutateur sur position o Chauffage Indiquer la temp rature ambiante d sir e Le g n rateur dar chaud est pr chauff Lorsque l int rieur de l appareil a atteint 40 C le ventilateur se met en route Lors que la temp rature ambiante est obtenue le br leur s arr te Quand la temp rature ambiante descend en dessous de la temp rature d sir e le br leur se remet en route automatiquement Chauffage avec jour m canisme de nuit Install z le control nuit jour selon ma nual technique puis proc dez comme chauffer avec thermostat d ambiance Chauffage sans thermostat d ambiance Regler le commutateur sur position Chauffage Le g n rateur d air chaud est pr chauff Lorsque l int rieur de l appareil a atteint 40 C r glage d usine le ventilateur se met en route Si la temp rature exc de la valeur mini ou maxi indiqu e r glage en usine 80 C le thermique limite remet le br leur en route ou l arr te Arret avec sans thermostat d ambiance 6 Regler le commutateur sur position 0 Un d marrage r p te du ventilateur a pour but d liminer la chaleur
26. hangeur de chaleur c te d aspiration Debrancher le courant lectrique voir ci dessus Apr s avoir enlev le paroi frontale cor r spondants d visser le couvercle de nettoyage enlever le joint et nettoyer par brosse et aspirateur Puis mettre un nouveau joint et remon ter l ordre invers 3 Nettoyer d changeur de chaleur c te soufflage Debrancher le courant lectrique voir ci dessus Apres avoir enlev les parois lat rales correspondants d visser le couvercle de nettoyage enlever le joint et nettoy er par brosse et aspirateur Puis mettre un nouveau joint et remon ter l ordre invers j Brenner Kundendienst RA Burner after sales service Der Brenner sollte mindestens einmal The burner should be checked and im Jahr berpr ft und einreguliert adjusted once anually On this occasion werden dabei mu der lfiltereinsatz the oil filter insert and the burner jet berpr ft werden have to be replaced Die Arbeiten d rfen nur vom Kunden This work must only be made by after dienst oder einem autorisierten Fachbe sales service or an authorized specialist trieb vorgenommen werden firm Reinigung Luftfilter Cleaning the air filter Bei Warmlufterzeugern mit Luftfilter soll Air filters should be cleaned or replaced ten diese entsprechend der Verunreini depending on their condition gung gereinigt oder erneuert werden U Service apr s vente br leur Le br leur devrait tre v
27. hmen Jegliche Anspr che aus Folgesch den durch Betriebsausfall der Warmlufterzeu ger sind von der Haftung ausgeschlossen Designated use Everywhere where heat is needed or to keep free of icing or for an agreable climate Kroll mobil space heaters are the ideal partners heating warehouses and store roomes heating of places of work in big shop floors and workshops heating greenhouses for assembling and repairing A Inappropriate use These space heaters are not suitable for household use must be used only by persons who have been instructed about their operation Responsibility In order to qualify for guarantee the device must be installed and commissioned by a specialist the settings are to be recorded in a measurement certificate Please fill out all the points of guarantee form correctly sign and send it to Kroll Please note that in case of missing mea suring vales no guarantee certificate will be issued The guarantee will only be granted if a re gular servicing is carried out at least once a year and in accordance with the Kroll operating instructions The results must be recorded in the applicable measurement certificates The usual guarantee period granted on our device covers 24 months after the delivery the date of the invoice being decisive Damage during transport Transport damages must be noted on the forwarders receipt and signed by the driver Your dealer must be notified of
28. ication technique dans le sens d am lioration du produit 30 Zubeh rteile f r Raumthermostat Warmlufterzeuger Room thermostat Thermostat d ambiance Accessories for space heater Accessoires pour g n rateur d air chaud Brennerverkleidung Burner housing Coffrage pour br leur Frischluft Umluft Fres air recirculating air Air ext rieur air recycl ber weiteres Zubeh r senden wir Ihnen auf Wunsch gerne ausf hrliches Informationsmaterial lfilter Oilfilter Filtre Schornstein Chimney Chemin e Schalld mmung auf Anfrage Paroi sond insulating upon request Equipment antibruit sur demande Do not hesitate to ask us for the complete catalogue about extensive accessories N hesitez pas a nous demander la liste compl te des differents accessoires Brenner Burner Brdleur Zuluftkanale Air inlet duct Gaines d air 31 Wartungsintervalle Servicing intervals Intervalles de maintenance Tag der Wartung Name Bemerkungen Day of servicing Name Notes Jour de maintenance Kroll GmbH W rme und L ftungstechnik Pfarrgartenstra e 46 Postfach 67 D 71737 Kirchberg Murr Telefon 49 0 7144 830 0 Telefax 49 0 7144 830 100 Kroll UK Ltd Azura Close Unit 49 Woolsbridge Ind Estate Dorset BH 21 6 SZ Three Legged Cross Wimborne Telefon 44 0 120 28 222 21 Telefax 44 0 120 28 222 22
29. ifs En g n ral la dur e de la garantie pour nos appareils s elevea 24 mois a datr de la livrai son la date de la facture est d ter minante Damage during transport Transport damages must be noted on the forwarders receipt and signed by the driver Your dealer must be notified of any technical damage before the appleance is assembled and set into operation The heater is only be started up after competent repair Des d g ts de cons quence r sultant d une interruption des g n rateurs d air chaud sont exclus de la responsabilit Grundlegende Sicherherheitshinweise Security instructions Instruction de base de securite Aufstellungsvorschriften kel FREES Nach DIN 4794 Teil 5 m ssen die Abgase ber einen f r l oder Gasheizger te genehmigten Schornstein oder Hilfsab zug ins Freie geleitet werden Der Schornstein kann gemauert oder aus Metall sein Die M ndung des Schornsteins mu das Dach um mind 1 m den Geb udefirst um mind 0 5 m berragen und in freiem Windsto liegen Die M ndung des Schornsteins darf nicht in unmittelbarer N he von einem Fenster oder Balkon liegen Abgastemperatur Bei Inbetriebnahme und Einregulierung Abgastemperatur auf min 160 C einstellen Installation der Rauchgasrohre Am Rohrstutzen mu ein Kapselwinkel f r Regen und Kondenswasser montiert werden Waagrecht verlegte Abzugsrohre max 1 3 der gesamten Abzugsrohrl nge ben tigen eine konstante S
30. instel len Vor Inbetriebnahme Elektroanschl sse vornehmen a lanschlu Der Anschlu erfolgt durch den Brennerkun dendienst l oder Gasbrenner Die Einstellung und Inbetriebnahme darf nur vom Kundendienst des jeweiligen Brennerfa brikates oder eines autorisierten Fachbetrie bes vorgenommen werden Die vom Brennerhersteller angegebenen Werte sind unbedingt einzuhalten A Brennerkundendienst Die Firma Kroll empfiehlt einen Wartungs dienst abzuschlieRen 12 Mount the space heaters a only on fire proof walls and according to the relevant standards equivalent to DIN 4794 part 5 b Mount levelly c The installation of the space heater must comply with the building regulations and all other applicable standards an legisla tion and standards DVGW TRGI 1986 DIN 4756 und TRF 1988 DVGW Standard G 600 Additional technical regulations TRF 1988 are to be observed when installing space heaters in room ground level AN Power connection The electric connection of the machine must be done by authorized personnel according to DINEN 50 156 1 VDE0116 1 2005 3 and DINEN 60 335 1 VDE0700 1 Pay attention to correct running direction with the three phase A C motors Set motor protector to correct value F Roomthermostat Do not mount in cold or warm air stream The connection must be carried out in accordance with the applicable technical regulations Connection and setting into operation must be
31. iz l nachf llen und eingeschaltet Luft im Brennstoffkreislauf Verschraubungen im Brennstoff lbrenner startet und geht sofort kreislauf auf Dichtheit pr fen auf St rung Filtereinsatz austauschen bzw lfilter verstopft Absperrhahn ffnen der Gasbrenner startet und geht Absperrhahn verschlossen Siehe Betriebsanleitung lbrenner sofort auf St rung lbrenner zeigt erneut St rung Vordruck am Manometer berpr fen Kein Gasdruck vorhanden Hauptabsperrhahn an der Gasuhr und Absperrhahn vor dem Brenner auf offene Stellung berpr fen Sicherheitstemperaturbegrenzer l st Temperaturw chter defekt Warmluftthermostat austauschen st ndig aus Temperaturw chter schaltet st ndig Temperaturw chter falsch einge Temperaturw chter auf Einstellung stellt berpr fen Gebl se startet nicht Gebl semotor oder Kondensator berpr fen bzw austauschen eventuelle Motorschutzschalter und Riementrieb berpr fen Brennstoffdurchsatz zu hoch Auf angegebenen Brennstoffdurch Umluftgitter bzw Luftfilter ansaug satz einregulieren seitig verstopft wenn als Zubeh r Umluftgitter bzw Luftfilter reinigen vorhanden und austauschen gnalleuchte am Schaltgehause leuchtet a Brennerstorung a lene Betriebsanleitung Brenner Le Der Warmlufterzeuger ist angeschlossen Hauptschalter und Sicherungen jedoch berpr fen Gebl se startet nicht wenn der b Gebl se defekt Gebl se austauschen Wahlschalter auf L ften c Kondensator defe
32. kt Kondensator berpr fen gestellt wird Bel Version 400 V Vlotorschutzschalter uberprufen b Keilriemen locker bei indirektem b Keilriemen nachspannen Antrieb Der Warmlufterzeuger ist angeschlossen jedoch Geblase startet nicht wenn der Wahlschalter auf L ften gestellt wird Der Warmlufterzeuger ist eingesteckt Kein Strom vorhanden a uleitung berpr fen l uft nicht d Feinsicherung hat ausgel st b Feinsicherung ersetzen V Cf chaltgehause offnen und die Reset Taste am Motorschutzrelais drucken Bei nochmaliger Auslosung muss der Motor durch Fachpersonal mechanisch und elektrisch berpr ft werden 23 24 Malfunction and remedy Warning Kroi All work on the electrical installation must be carried out by a qualified electricien Pull power supply plug only when the heater has entirely cooled down See also operating instructions for oil gasburner TC Malfunction The space heater ist connected up but The heater does not start when the selector switch is set to heating The space heater is connected up and switched on The oil burner starts and immediately indicates a malfunction the gas burner starts and immediately indicates a malfunction Temperature controller continually switches off a b c d No electrical supply Defective selector switch Oil gasburner indicates a malfunction Overheat thermostat is locked Room thermostat f
33. lten siehe oben 4 Besfetigungsschrauben am Brenner flansch l sen und den Brenner abneh men Brennkammer mit B rste und Staub sauger durch die ffnung reinigen Brenner mit den 4 Befestigungs schrauben wieder am Brennerflansch anschrauben 2 Reinigung W rmetauscher Ansaugseite Strom abschalten siehe oben Nach Entfernen der Vorderwand Rein gungsdeckel abschauben Dichtungs band entfernen und mittels B rste und Staubsauger reinigen Danach neues Dichtungsband anbrin gen und in umgekehrter Reihenfolge wieder zusammenbauen 3 Reinigung Warmetauscher Ausblasseite Strom abschalten siehe oben Nach Entfernen der entsprechenden Gehausewande Reinigungsdeckel abschrauben Dichtungsband entfer nen und mittels Burste und Staubsau ger reinigen Danach neues Dichtungsband anbrin gen und in umgekehrter Reihenfolge wieder zusammenbauen 10 The heat exchanger and the combustion chamber should be thoroughly cleaned and checked by a specialist at least once a year Kroll recommends taking out a service contract Set selector switch to 0 before starting maintenance work on the space heater After the heater has cooled down the main power switch must be turned off Cleaning of combustion chamber Turn off electrical supply see above Loosen 4 clamping bolts on burner bracket Remove burner Clean combustion dchamber with brush and vacuum cleaner through the opening Fixing
34. lverschraubung Cable screw Raccord de c ble 023158 egenmutter Locking corner Contre crou 023208 emperaturregler Temperature regulator R gulateur de temp rature 049290 emperaturw chter Overheat thermostat Contr leur de temperature 049291 chaltgeh use Control box Boitier de commande 027185 01 Barre a bornes 025452 gris Zugfederklemme Connecting strip grey grau Barre a bornes 025451 blue Zugfederklemme Connecting strip blue m 025453 Zugfederklemme Connecting strip green Barre bornes gr n gelb yellow verte jaune a EI D Kabelverschraubung Cable screwing 3x Raccord de c ble 3x 022993 gt sesenmuterse Locking comer 7 Joan 020208 p Brennerkabel C ble du br leur 029251 r Kondensator Capacitor Condensateur 005715 25S 10uF 25S 10uF 25S 10uF 40S 25UF 40S 25uF 40S 25uF 005590 16 Position 32 Schaltgehause Position 32 Control box Position 32 Bo tier de commande hae FISSIIIIIIG naan GEES Le _ 7 I erh s SYS or _ gt JS Wi 18 19 0 2 N A N 3 N N 25 6 N 7 N co oO 32 33 4 O1 N O0 O CA co Einzelteile Luftlenkjalousie Seitenwand Strahlenschutz Seitenwand Wirbulator Deckel Reinigungsdeckel Dichtungsband Spannring Zentrierring Durchzugsdichtung Brennkammer W rmetauscher Reinigungsdeckel Dichtungsband Strahlenschutz R ckwand Umluftwand Seiten
35. m and the roof ridge by at least 0 5 m It must be expo sed to the free wind conditions The opening of the chimney must not be in the vicinity of a window or a balcony Temperature of exhaust fumes When setting into operation and adjusting set temperature of exhaust fumes for at least 160 C Installation of flue pipes A catch elbow must be connected to the flue connector for rain water condesation Horizontally installed flue pipes max 1 3 of total flue pipe length must have a continuous gradient of 2cm per metre Flue pipes must be interconnected in the direction of the draft Installation or the pipe system Pay attention to the maximum pressure If this exceeded the air volume of the fan will fall and both the flue gas and warm air temperature will rise Ventilation Sufficient air for combustion must be available avoid low pressure in the installation room This is assured when e g the volume of the room in m is a minimum of 10 times the rated heat load in kW of all the heating appliances in the room Normal circulation is to be guaranteed via windows and doors If low pressure or dust in the room air are not avoidable the burner must be encased and the air supply taken from outside the room Warning The space heater is only to be installed on combustible floor An area of 1 m around the heater is to be kept clear to ensure an unobstructed flow of air to and from the heater Exept from connectio
36. n conduit pressure Mount a notice Protective zone of 1 m depth to be kept clear one air inlet side panel Do not switch off electrical sup ply and main switch until the space heater has cooled down Non compliance invalidates the factory guarantee iroi Directives de montage APES Selon les normes en vigueur les gaz br les doivent tre vacu s par une che minee ou par un conduit de fumee auxi laire agr s pour appareil de chauffage au fuel ou au gaz La chemin e peut tre en ma onnerie ou en m tal Il faut que la chemin e d passe le toit d au moins 1 m et le f itage du b timent dau moins 0 5 m et qu elle soit d gag e La sortie de la chemin e ne doit pas tre plac e proximit imm diate d une fen tre ou d un balcon Temp rature des gaz br l s Lors de la mise en service et du r glage de l appareil r gler la tem rature de sortie 160 C minimum Installation des tuyaux d vacation des gaz Sur la buse le d part il es recommande de monter un pur l eau de pluie et l eau de condensation Les tuyaux pos s horizontalement au max 1 3 de la longueur de tuyau totale ont besoin d une d clivit constante dau moins 2 cm par m tre Embo tier les tuyaux dans le sens du tirage Installation du syst me de gainage Respecter la pression maximale S il y a d passement de la pression la puissance du ventilateur faiblit et la temp rature des gaz br l
37. norms are applicated DIN EN 1020 1997 DIN EN 1020 A1 2001 Les normes suivantes sont appliquees Eine technische Dokumentation ist vollst ndig vorhanden A technical documentations is completely at hand Une documentation technique complete existe Kroll GmbH Kirchberg Murr den 22 Juli 2008 71737 Kirchberg Murr Pfarrgartenstra e 46 Tel 07144 8300 Fax 830100 Gesch fts Directeur 26 Kroll GmbH W rme und L ftungstechnik Garantieanforderung Pfarrgartenstra e 46 Postfach 67 D 71737 Kirchberg Murr Telefon 49 0 7144 830 0 Telefax 49 0 7144 Wir haben den nachfolgeden Kroll Warmlufterzeuger Warmluft Heizungsanlage erhalten und vom angef hrten Heizungsfachbetrieb bekommen Fabr Nr Unser Heizungsfachbetrieb Errichter Telefon ir die Bedienung und Wartung ist bei un st ndio He Am Abschlu eines Wartungsvertrages f r das Ger t sind wir interessiert Bitte informieren Sie uns n die Funktion des Ger tes bzw der Anlage wurden wir umfassend eingewiesen Die Betriebsanleitung wurde uns bergeben Wir bitten um Zusendung der Garantieurkunde D Ort ou atum Gas Stempel und Unterschrift Betreiber Montierter Brenner Type Nr Gasbrenner asart asduse Filter eingang mbar Me wert Warme Brenner belastung Ansaug Q gefahren temperatur temperatur motor Strom im Mittel aufnahme A Phase Der Warmlufterzeuger Warmlutt Heizungsanlage wurde von
38. nstalle et mis en route le generateur l installation de chauffage conformement Aux prescritions de la notice d utilisation ainsi ou avoir montre au client comment utiliser et entretenir son appareil Date de livraison Cachet et signature de l installateur 29 remplir par l utilisateur A remnlir nar l inetallataur ro Bei nicht bestimmungsgem er Verwendung Aufstellung Wartung wie in der Betriebsanleitung vorgegeben oder eigenm chtigen nderungen an der werkseitig gelieferten Ger teausf hrung erlischt jeglicher Gew hrleistungsanspruch Im brigen gelten unsere Verkaufs und Lieferbedingungen Technische nderungen im Sinne der Produktverbesserung vorbehalten Any use installation maintenance that is not effected according to the rules as asserted in the technical manual or unauthorized modifications on the original version as delivered from manufacturer leads to expiration of any right to warranty Furtheron our Conditions of Sales and Delivery are valid Technical modification for product improvement are subject to change without notice Toute utilisation installation et maintenance qui ne soit pas effectu conform ment aux directives fix s dans le manuel technique ainsi que toute modification l appareil livr du fabricant dans sa version originale entraine l expiration du droit de garantie En plus nos Conditions de vente et de livraison sont en vigueur Sous r serve de modif
39. nstearianenncewnctens 30 Basic instructions Kroll space heaters 25S bis 110S are the result of thenth of years of experience and in tensif developement work We are con vinced of handing you over a high quality product Never the less the heater must be installed set into operation and tested by measu rings correspondending to respective circustances by a specialist Read the operation instruc tions A carefully prior to instal ling and comissioning the heater All details stated refering tue installation and setting into operation must be effected and observed carafully in order to grant an econo mic operation free of malfuctions The space heaters are proved in accor dance to DINEN 1020 1382 and must be equipped with an automatic control box which is permitted for the space heater Edition 880809 Drawing number 029127 01 Technical changes in the sense of product improvement reserved Privileg of the producer Firma Kroll GmbH iroi Sommaire Instruction de base 2 DESIGN ANON ess 3 Instruction de base de sE amp curite 4 Sch ma d ensemble 6 Carateristiques techniques 7 Mise en marche eee eeee eee eeeesueeeees 8 EREECHEN eege 10 MIDI en eus 12 Gaz de combustion 13 Schema lectrique 25S 40S 55S 70S 14 Schema lectrique 709S 15 Nomenclature 25S jusqu a 7OS 16 Nomen
40. oil pump oil pump pe 5 D se Nozzle SS 0 ECH S O bag S 1 1 60 S 1 En S ma S 1 Es S Danfoss weg EE a en eee ea m Stellung D senstange Barre debec de bec Brennerrohrl nge er of burner Longueur tube 115 tube d air du br leur Measure A Dimension A NW 2 ze Ma B Measure B Dimension B a 7 0 7 Ma C Measure C Dimension C et e EE Lt 5 H here Pressung auf Anfrage Higher pressure upon on request Plus pression demande le fabricant Inbetriebnahme setting into operation Mise en marche Die Steuerung des Warmlufterzeugers und des Brenners erfolgt ber den Wahlschalter ber den Raumthermostat oder die Tag und Nachtautomatik AN Stromanschlu Der elektrische Ger teanschluss ist durch autorisiertes Fachpersonal nach DINEN 50 156 1 VDE0116 1 2005 3 und DINEN 60 335 1 VDE0700 1 auszuf hren Heizen mit Raumthermostat 1 Wahlschalter auf sa Heizen stellen 2 Gewunschte Raumtemperatur am Raumthermostat einstellen Der Warmlufterzeuger wird aufgeheizt Bei 40 C Geratetemperatur Werkseinstellung wird das Geblase in Betrieb gesetzt Nach Erreichen der eingestellten Raumtemperatur schaltet der Brenner ab Nach Unterschrei tung der eingestellten Raumtemperatur schaltet der Brenner automatisch wieder ein Heizen mit Tag und Nachtautomatik 3 Tag und Nachtautomatik installieren und gem Betriebsanleitung program 4 mieren danach
41. ontrol box Boitier de commande Boden Bottom plate T le de fond Technische Daten technical data Caracteristiques techniques Technische Daten Technical data Gala erelgles techniques Warmlufterzeuger Space heater ad Standard Standard Standard 1105 lbefeuert Oil fired Brennstoff l Combustible Heiz l EL Fuel oil Fe combustible Brennstoff Gas Gas ssid Gaz ssid Ei E Natural gas E Gaz ECS E efficienc nominal Puissance Nennw rmebelastung Rated heat load en NI Nennlufwvolimenstrom 1 450 2 710 3 400 4 300 6 000 7 000 Luftvolumenstrom Air delivery D bit d air 1 650 2 900 3 700 5 000 6 750 7650 Fe ET temp rature At Pression Nenndruck Nominal pressure Gef Frei ausblasend Electrical power SEH we ts 230 50 230 50 ou 400 3N 400 3N Stromverbrauch consumption lectrique 3 05 6 84 3 6 3 6 onnection Ale triq e Ger uschpegel a Se ee awe EC Date E SES Abmessungen Dimension Dimension Length Longueur mm 715 865 975 1085 1 150 1 150 en a Largeur mm 455 505 585 66 765 765 H he 0 JHeghtt Hauteur reside sang 1275 1500 1645 1835 1 895 1 995 W Schutzart mA of protection IP 20 A Y BWV ifan S Marzorati Nicotra Nicotra Gebl se type Fan type Ventilateur type DAE ee ee Ge SC ER Gebl sedrehzahl Fan PH Nombre de tours om EEN 1100 1450 ETS ventilateur R20 W R1 V R1 V R1 V R20 AE R20 AE Druck Druck lpumpe Pressure
42. principale au compteur et la vanne au br leur sont bien ouvertes Remplacer l airstat V rifier le r glage de thermique limite V rifier roteur du ventilateur condensateur fusible et courroie Remplacer si necc ssaire R gler le d bit selon les indications Nettoyer ou changer la grille de reprise ou filtre air a Voir instructions de service de br leur a V rifier l interrupteur principal b Remplacer le ventilateur d air chaud c V rifier condensateur V rifier protection moteur b Rentendre la courroie Pas de courant e g n rateur d air chaud est branch a mais ne fonctionne pas b Fusible fin d clencher t ampe temoin au s allume a V rifier alimentation lectrique t pousser le bouton de r armement au relais de protection de moteur En cas de declenchement repete le moteur doit tre v rifi d un sp cialiste Kroi 29 EC Conformity D claration de conformet CE ro im Sinne der in accordance With CE Directive selon la r gl mentation EG Richtlinie 98 37EG Maschinen Richtlinie directive for machines CE machines 91 368EWG Gasverbrauchseinrichtungen gas consuming appliances installations consumant du gaz EG Richtlinie 73 23 EWG Niederspannungs Richtlinie Low tension directive Directive basse tension EG Richtlinie 89 336 EWG Richtlinie elektromagnetische Vertr glichkeit EMV directive EMV directive EG Richtlinie 90 396
43. r glage du thermostat d ambiance Il ny a pas de fuel dans le r servoir Il y a de l air dans la circulation de combustible Le filtre fuel est encrass Vanne d arr t ferm e Br leur en derangement nouveau Pas de pression Le thermique limite d fectueux Le thermique limite est mal r gler Le ventilateur ne d marre pas Le d bit du combustible est trop lev Grille de reprise d air ou filtre air bouch s ampe t moin au boitier lectrique a Le bruleur en derangement s allume la ventilation ne se met pas en route lorsque le commutateur est sur position ventilation la ventilation ne se met pas en route lorsque le commutateur est sur position ventilation Pas de courant Le ventilateur d air chaud est d fectueux Condensateur d fectueux d fectueuse Courroie d tendue dans le cas d entra nement pour courroie V rifier l interrupteur principal et les fusibles Remplacer le commutateur Rearmer le br leur fuel gaz si br leur nouveau en s curit attendre 4 5 min et r armer une nouvelle fois Cf instructions de service de br leur Appuyer sur le bouton de r armer V rifier le r glage du thermostat d ambiance Remettre encore fuel V rifier l tanch it de la boulonne rie de la circulation de combustible Remplacer la cartouche filtre Ouvrir la vanne d arr t Cf Instructions de service du br leur V rifier la pression au manometre V rifier si la vanne
44. rdance with the Installation and operating Inst ructions The customer has been fully instructed in the servicing and operation Date of delivery installation ignature and stamp of heating contractor ed by after sales service To be filled in by the user To be filled in by skilled work shop Kroll GmbH W rme und L ftungstechnik Demande de Garantie Pfarrgartenstra e 46 Postfach 67 D 71737 Kirchberg Murr Telefon 49 0 7144 830 0 Telefax 49 0 7144 Nous avons achete le G n rateur Kroll suivant aupres du revendeur chauffage mentionne ci ap s De serie Notte revendeur chauffage Tel onne responsable de l entretien M Nous sommes interesses par un contrat d entretien Merci de nous envoyer de la documentation Nous avons ete mis au courant de toutes les fonctions de l appareil ou de l installation Nous avons recu la notice technique Merci de nous envoyer le certificat de garantie Lieu Date Cachet et signature d l utilisateur Fuel Gaz Polycombustible Br leur mont Type No ype de cleur ression gaz l entr e Au filtre Ka O t Q Q ZS ulssance emp Moteur brute d aspiration sortie de chaleur noireisse moyenne de ventilateur Q du br leur fumees ment sortie A phase kW Bacharach C air Brdleur regl et mis en service le Par Appareil install e dans chaufferie dans atelier Ave cocau gainc Nous certifions avoir i
45. rifi et r gl au moins une fois par an En cette occu rance le cartouche filtrante et la buse du br leur doivent tre rem plac es Ces travaux ne doivent tre effectu s que par le service apr s vente ou bien un sp cialiste agr Nettoyage des filtres air Lorsque les g n rateurs dar chaud sont quip s de filtres air ceux ci devront tre nettoy s ou remplac s si n cessaire 11 Montage Mounting Montage Den Warmlufterzeuger a nur an feuersicheren W nden und nach DIN 4794 Teil 5 montieren b waagrecht aufstellen c bei der Aufstellung des Warmluft erzeugers sind folgende Richtlinien und Normen einzuhalten DVGW TRGI 1986 DIN 4756 und TRF 1988 DVGW Arbeitsblatt G 600 Bei der Aufstellung unter Erdgleiche sind besondere Anforderungen der TRF 1988 einzuhalten AN Elektroanschlu Der elektrische Ger teanschluss ist durch autorisiertes Fachpersonal nach DINEN 50 156 1 VDE0116 1 2005 3 und DINEN 60 335 1 VDE0700 1 auszuf hren Bei Drehstrommotor auf richtige Laufrichtung achten Motorschutz richtig einstellen E Raumthermostat Montage nicht in kaltem oder warmem Luftstrom a Gasanschlu Der Anschlu mu entsprechend DVGW Arbeitsblatt G 600 DVGW TRGI erfolgen Anschlu und Inbetriebnahme d rfen nur von einem zugelassenen Gas Installateur vorgenommen werden Gaszufuhr und Anschlu auf absolute Dicht heit pr fen Brenner auf rtliche Gasverh ltnisse e
46. s dringend notwendig das von Kroll angebotene Abgaszubeh r einzusetzen Inbetriebnahme zum Probelauf Wahlschalter bet tigen Heizen ohne Raum thermostat sk Abschalten Wahlschalter auf 0 stellen berpr fen der Me werte nach den techni schen Daten und Eintragen in die Garantie Anforderung Whe run with gas the flue pipe must be put into the flue outlet by means of an adapter pipe The opening of the flue pipe must clear the roof at least 1 m and the roof ridge by at least0 5 m It must also be exposed to the free wind conditions The opening of the flue pipe must not be in the Installation A catch elbow must be connected to the flue connector for rain water and condensation Horizontally installed flue pipes maximum only on third of the total flue pipe length must have a continuos gradient of 20 mm per meter Flue pipes must be interconnected in the direction of the draft Si l appareil est op r avec du gaz le tuyau de chemin e doit tre mis dans le manchon de chemni e par un adapteur Il faut que la chemin e d passe le toit dau moins 1 met le f tage du b timent d au moins 0 5 m et qu elle soit plac e l abri des coups de vent La sortie de la chemin e ne doit pas tre plac e proximit imm diate d une fen tre ou d un balcon Installation Sur la buse de d part il est recommand t de monter un pour de pluie et l eau de condensti on Le tuyaux pos s hori
47. teigung von mind 2 cm pro Meter Abzugsrohre in Zugrichtung stecken Installation des Kanalsystems Maximale Pressung beachten Bei berschreitung f llt die Luft leistung des Ventilators und die Abgastemperatur sowie die Aus blastemperatur steigen Bel ftung F r die Verbrennung mu eine ausreichende Luftmenge zugef hrt werden Unterdruck im Aufstellungsraum vermeiden Dies ist gegeben wenn z B der Rauminhalt in m mind der 10fachen Nennw rmebelastung in kW aller im Raum betriebenen Ger te entspricht Durch Fenster und T ren nat rlichen Luftwechsel sicherstellen Wenn Unterdruck und staubhaltige Raumluft nicht vermeidbar sind mu der Brenner verkleidet werden Achtung Den Warmlufterzeuger nicht auf brennbarem Boden aufstellen Zum ungehinderten Ansaugen und Aus blasen der Luft ist eine Schutzzone im Abstand von 1 m freizuhalten Au er bei Kanalanschlu Pressung Hinweisschild anbringen Schutzzone 1 Meter Abstand freihalten an einer Ansaugseite Erst nach Abk hlung des Warm lufterzeugers Strom und Haupt schalter abschalten Zuwider handlung schlie t Werksgarantie aus Installation regulation Cr The exhaust fumes must be conducted into the open through a chimney or flue approved for oil or gas heating app liances and in acoordance with all appli cable standards The chimney can be in masonry or metal The opening of the chimney must clear the roof by at least 1
48. ue par des instal lateurs agr es V rifier l tanch it absolue de l arriv e de gaz ainsi que du raccordement R gler le br leur selon les normes r giona les Effectuer les raccordements lectriques avant la mise en service a Raccordement au fuel Le raccordement s ffectue par le service apres vent du br leur Br leur au fuel ou au gaz Le r glage et la mise en service du br leur doivent tre ex cut s par le service apr s vente du fabricant des br leurs ou par un sp cialiste agr Les valeurs indiqu es par le constructeur des br leurs sont respecter imp rativement A Service apr s vente br leurs Le societ Kroll conseille de souscrire un contract d entretien Abgase Exhaust fumes Gaz de combustion Kroll Gasbetrieb muss das Abgasrohr mittels eines Adapterrohrs in den Abgasstutzen des Ger ts gesteckt werden Die M ndung des Abgasrohres mu das Dach um mind 1 m und den Geb udefirst um mind 0 5 m berragen und im freien Windsto liegen Die M ndung des Abgasrohres darf nicht in unmittelbarer N he von einem Fenster oder Balkon liegen Installation Am Rohrstutzen mu ein Kapselwinkel f r Re gen und Kondenswasser montiert werden Waagrecht verlegte Abzugsrohre max 1 3 der gesamten Abzugsrohrl nge ben tigen eine konstante Steigung von mind 20 mm pro Meter Abzugsrohre in Zugrichtung stecken F r einen sicheren Betrieb der Ger te ist e
49. uns entsprechend der Installations und Betriebsanleitung ordnungs gem installiert und in Betrieb genommen Der Kunde wurde in die Wartung und Bedienung ausf hrlich eingewiesen Vom Betreiber auszuf llen nm LCanhhatrinh eat test CH en ra Kroll UK Azura Close Unit 49 Woolsbridge Industrail Estate Garantie request Dorset Wimborne BH 216 SZ Three Legged Cross iroi We have received the following Kroll space heater heating system which has been installed by the heating contractor listed below serial No ur heating contractor installer Telephone The following person in our firm is responsible for the operating and servicing Mr We are interested in taking out a service contract on the appliance Please send us further information We have been fully instructed in the operation of the appliance or system We have been given the operating instructions Please send us the guarantee certificate Place Date User s signature ang sta Oil Gas biked Oil Gas Burner installed Manufacturer Type No Oil burner Gas burner Nozzle type and ype o as Ow pres ow pressure nozzle number pressure gas nozzle sure filter pump inlet bar mbar 1 level Power con Inlet sumption temperature Fan motor Test data in the space to be heated Appliance installed in Boiler room SE 2 q em ngth approx e space heater heating system has been installed and set into operation in acco
50. wand Luftlenkjalousie Umluftwand Strahlenschutz Seitenwand Leitblech St tzprofil Boden Radialgebl se Zwischenboden Isolierung Brennkammer Gegenflansch Brennerplatte Brenner Strahlenschutz Vorderwand unten Halteblech Steuerger t Schaltgeh use Abdeckwand Luftlenkjalousie Vorderwand St tzprofil Leitblech Reinigungsdeckel Dichtungsband Umluftwand side panel Combustion chamber side panel Counter flange combustion chamber Burner Protective screen Front panel below Mounting support control box Recirculating panel Nomenclature Lamelles orientables Paroi lat rale Manteau int rieur paroi lat rale Turbulateur Couvercle Couvercle de nettoyage Joint Tendeur Centrage Joint Chambre de combustion Echangeur de chaleur Couvercle de nettoyage Joint Manteau int rieur Paroi arri re Paroi de reprise d air Paroi lat rale Lamelles orientables Paroi de reprise d air Manteau int rieure paroi lat rale T le de chicane d air Support T le de fond Ventilateur radial Fond interm diaire Isolateur Contre bride chambre de combustion Plaque de br leur Br leur Manteau interieur Paroi frontale en dessous Support boitier de commande Boitier de commande Capot Lamelles orientables Paroi frontale Support T le de chicane de d air Couvercle de nettoyage Joint Paroi de reprise d air Bestell Nr Requisition number Num ro de commande 027863 0278
51. zbereichen wo geheizt werden mu zur Frostfreihaltung oder f r ein angenehmes Klima sind die Kroll Warmlufterzeuger die idealen Partner Beheizung von Lagerr umen f r Arbeitspl tze in gro en Werkhallen oder Werkst tten Beheizung von Gew chsh usern f r Verkaufsr ume N Sachwidrige Verwendung die Warmlufterzeuger sind f r den Hausgebrauch nicht geeignet und d rfen nur von Personen bedient werden die in der Bedienung unterwiesen sind Gew hrleistung und Haftung Zur Erlangung der Garantie ist das Ger t von einem Fachmann zu installieren und in Betrieb zu nehmen Die Einregulierung ist in einem MeRprotokoll nachzuweisen Die Garantieanforderung bitte in allen Punk ten richtig auszuf llen unterschreiben und an Firma Kroll einsenden Bitte beachten Sie da bei fehlenden Me werten keine Garan tieurkunde ausgef llt werden kann Weitere Voraussetzung f r die Garantie ist eine regelm ige Wartung laut der Kroll Betriebsanleitung durchzuf hren und mit den entsprechenden Me protokollen nachgewie sen werden mu Die allgemeine Garantiezeit f r unsere Ger te betr gt 24 Monate nach erfolgter Lieferung ausschlaggebend ist das Rech nungsdatum Transportsch den Transportsch den m ssen auf dem Spe ditionsannahmeschein vermerkt und vom Fahrer quittiert werden Technische St run gen m ssen unverz glich Ihrem H ndler angezeigt werden Ger t erst nach Instand setzung in Betrieb ne
52. zontalement au max 1 3 de la longueur de tuyau totale ont besoin d une d clivit constante dau moins 20 mm par m tre Emboitier les tuyaux dans le sens du tirage For a safe operation of the apparats it is absolutely necessary to use the Kroll flue gas accessories Setting into operation for test run Set selector switch to Heating without room thermostat sk Turning off Set selctor switch to 0 Examining of the measuring values accor ding to technical data and registering in the demand for garanty Pour une op ration s re des appa reils il est absoluement n cessaire d utiliser les kits de chemin e Kroll Mise en marche en course d essai R gler le commutateur sur position Chauffage sans thermostat d ambiance zk Arr t Regler le commutateur sur position 0 Examination des valeurs selon donn s technique et registration dans la demande de guarantie 13 Schaltplan Circuit diagram Sch ma lectrique 25S 40S 55S 70S Kroi Bei Anschlu eines Raumthermo states Br cke zwischen Klemme 5 und 6 entfernen Remove bridge connector 5 6 when room thermostat is connected Pour raccordement d un thermostat d ambiance enlever le shunt entre 5 et 6 Zuleitung RE be rl Supply line Alimentation _ _ j ARE ii l _2 se lt 3 522 ES H ah sal B3 1 Beagle PORN eg degen a ARE TE CPE TE E RE
Download Pdf Manuals
Related Search
Related Contents
Cellular Engine Siemens M20 / M20 Terminal 5230 IP Appliance Cartão de Iniciação Rápida Here - PDXTuning.com LA9014 User Manual -CCTR Ovation Release Notes Installation User Manual MP112E Manual en Pdf - tienda.www.tienda.centreelial.es dans le Parc naturel régional Scarpe-Escaut - illustration Manual de Programação IEC 61131 Copyright © All rights reserved.