EN DE Original-Montage- und Betriebsanleitung Original assembly

image

Contents

1. Setting cable M56 Connecting cable to limit stop terminals Connect the adjusting cable to the connecting cable of the motor Please always connect cores of identical colours here The assignment of the direction keys 1 and 2 to the direction of rotation depends on the installation situation of the drive Then connect the adjusting cable to the 230V mains www geiger de EN 7 9 Obstacle detection When after the teaching of the first complete uninterrupted travel from one end position to the other end position is carried out the torque needed is learnt In any following complete uninterrupted travel from end position to end position the torque needed is automatically readjusted Slow changes in the installation due to ageing soiling cold or heat are thus automatically taken into consideration This process takes place for both running directions independently of one another If a travel movement in up direction is blocked by an obstacle the motor switches off The running direction in which the obstacle was recognized is blocked The block is removed if the motor has been operated in the opposite direction for a certain time An obstacle must thus first be released before the motor can be operated again in the direction of the obstacle 10 End position correction Should an awning elongation have resulted due to temperature changes this is corrected at the next end position correction If d
2. Antriebstechnik Tubular motor GEIGER SOLIDline Motor control GEIGER SoftPlus Qi GU45 E09 for cassette awnings and folding arm awnings Original assembly and E TR t EN operating instructions EN Index 1 General information nnnsesssnnnnssennnnnnnnnnnnnnnnnnnnnnnnnnannnnnnnnnnn 2 2 Guarantee irpan cocentexeed devareseudeshvees aAa AEAN SANKE SaN i 2 Sur ao LeTo Ma EE E 3 A Safety iNStrUCHONS units aha ae 3 5 Safety instructions for assembly uuuusssssnnnnnnnnnnnnnnnnnnnnnnnnnn 4 6 Installation instructions unesssnnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 5 7 Information for the specialist electrician 6 8 Setting of the end positions unnssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 7 9 Obstacle detection iz ann 8 10 End position correction rsursunrnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 8 11 What to do If axcnsuenrennann rennen nee 8 12 MaintenanCe iiaea aiaa clcctieesccenteteceasscestecenteisccsseatecacesses 8 13 Declaration of conformity uunnnssssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 9 14 Technical data 2 10 15 Notes on waste disposal c ccceeeeeeceeeeeeeeeeeeeeeeeeeeeeeees 10 1 General information Dear customer By purchasing a GEIGER motor you have decided on a quality product from GEIGER Thank you very much for your decision and the confidence placed in us B
3. balance signs of wear or damaged cables and springs if relevant Do observe the moving sun protection system and keep persons away until it has closed completely gt When operating the manual release with the sun protection system open please be cautious as it can fall down quickly if springs or tapes wear off or are broken gt Do not operate the device if operations such as for example window cleaning are to be carried out in the vicinity Disconnect the automatic controlled device from the mains power supply if opera tions such as for example window cleaning are being carried out in the vicinity During operation observe the danger zone Do not use the installation if people or objects are in the danger zone Urgently shut down damaged installations until repair Unconditionally shut down the unit during maintenance and cleaning operations Pinching and shearing points are to be avoided and must be secured This appliance can be used by children aged 8 and above and persons whose physical sensorial or mental capacities are impaired or who have no experience or EN know how if they have been supervised or been given instructions on the use of the appliance and if they understand the possible resulting dangers Children are not permitted to play with the device Cleaning and maintenance should not be carried out by children gt The rated sound pressure level is less than 70 dB A gt Disconnect the device from the mains power supply
4. 4520 GU4530 GU4540 GU4550 Voltage 230 V 50 Hz Current 0 36A 0 47A 0 63 A 0 8A 1 0A 1 0A Cos Phi cosy gt 0 95 Inrush current factor x 1 2 Power 83 W 105 W 140 W 180 W 220 W 220 W Torque 6Nm 10 Nm 20 Nm 30 Nm 40 Nm 50 Nm Speed 16 rpm 16 rpm 16 rpm 16 rpm 16 rpm 12 rpm Protection class IP 44 Total length 506 5 516 5 546 5 566 5 586 5 586 5 mm mm mm mm mm mm Operating mode S24min S24min S25min S24min S24min S24min Sound pressure level 39 dB A 39 dB A 41dB A 41dB A 43 dB A Diameter 45 mm Weight approx approx approx approx approx approx 1 85 kg 1 90 kg 2 20 kg 2 40 kg 2 70 kg 2 70 kg Ambient temperature humidity Operation T 10 C 60 C H max 90 Storage T 15 C 70 C dry and non condensing place 1 SOLIDIine ZN 1 mm SOLIDline COM SIC 3 5 mm SOLIDline SOC 3 mm 2 The average sound pressure level data are intended for guidance only The values were determined by GEIGER at a distance of 1 m with a hanging motor at idle speed and averaged over 10 seconds There is no reference to any specific test standard Subject to technical modifications 15 Notes on waste disposal Recycling of packaging materials In the interest of environmental protection please contact your local government s recycling or solid waste management department to learn more about the services it provides CEDAS Waste disposal of electric and electronic equipment Electrical and electronic equipment must be
5. awnings Type designation GJ56 GR45 GU45 The designated product is in conformity with the European Directive 2006 42 EC Directive 2006 42 EC of the European Parliament and of the Council of 17 May 2006 for the approximation of laws regulations and administrative provisions of the Member States concerning machinery 2004 108 EC Directive 2004 108 EC of the European Parliament and of the Council of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89 336 EEC The conformity of the designated product with the provisions of the directives is proved in particular by full compliance with the following standards DIN EN 60335 1 DIN EN 55014 1 EN301 489 03 DIN EN 60335 2 97 DIN EN 55014 2 EN300 220 3 DIN EN 62233 DIN EN 61000 3 2 DIN EN 61000 3 3 The accredited VDE Testing and Certification Institute EU Identification No 0366 Merianstr 28 D 63069 Offenbach tests and certifies for the company Gerhard Geiger GmbH amp Co KG Authorised representative for technical data Gerhard Geiger GmbH amp Co KG Address Schleifm hle 6 D 74321 Bietigheim Bissingen of p Ze Ace GREG Bietigheim Bissingen 15 02 2013 Hans Michael Dangel General Manager www geiger de EN EN EN 14 Technical data Technical data of tubular motor SOLIDline KS GU45 GU4506 GU4510 GU
6. cables of the same type The device must be mounted as described in the installation instructions Fixations shall not be made with adhesives since they are regarded as unreliable 4 EN Gerhard Geiger GmbH amp Co KG 100W1512en V001 0613 6 Installation instructions Before fixing the strength of the masonry or of the subsurface is to be checked Prior to installation please check to ensure there is no visible damage to the motor like cracks or open cables Caution If the tube is screwed riveted to the drive the measure must be taken from the tube end to the center of the drive and marked on the tube When drilling the winding shaft never drill into the area of the tubular motor When inserting into the shaft the tubular motor must not be struck and must not be allowed to fall into the shaft Installation into the awning Insert motor with a suitable adapter and drive into the shaft up to the stop of the shaft adapter Fix the motor support on the awning Fix the motor together with the shaft on the motor support The bearer locks into place Depending on the selected motor head diffe rent fixation systems can be used Place the motor with square insert in the star shaped bearer and lock with pin Place the motor into the existing engine bearer and lock Place the motor in a compatible engine bearer with clip system and lock with spring or rotating lever The GEIGER SOLIDline
7. collected and disposed of separately in accordance with EU regulations 10 EN Gerhard Geiger GmbH amp Co KG 100W1512en V001 0613 www geiger de EN 11 EN EN For technical questions please call our service team at 49 0 7142 938 300 They will be happy to assist you Antriebstechnik Gerhard Geiger GmbH amp Co KG Schleifm hle 6 D 74321 Bietigheim Bissingen Telephone 49 0 7142 938 0 Telefax 49 0 7142 938 230 E Mail info geiger de Internet www geiger de 12 EN Gerhard Geiger GmbH amp Co KG 100W1512en V001 0613
8. efore you put this drive into operation please observe the following safety instructions It serves for the prevention of danger and for the avoidance of personal injury and damage to property The installation and operating instructions contain important information for the installer the specialist electrician and the user Please pass on these instructions if you transfer the product These instructions should be kept by the user 2 Guarantee In the case of incorrect installation contrary to the installation and operating instructions and or constructional modification the legal and contractual guarantee for property damage and product liability lapses 2 EN Gerhard Geiger GmbH amp Co KG 100W1512en V001 0613 3 Intended use The tubular motors of the model range SOLIDline GU45 E09 with electronic limit stop are designed exclusively for the operation of cassette awnings and folding arm awnings The motors may not be used for the operation of roller grilles garage doors furniture and lifting tools GU 45 xx x Motor control Torque in Nm Motor diameter GEIGER universal drive 4 Safety instructions ATTENTION Important safety instructions For personal safety it is important to follow these instructions Please keep these instructions for future reference gt Do not allow children to play with stationary controls Keep remote controls away from children gt The installation is to be checked regularly for defective
9. for maintenance and replace ment of parts If the motor is disconnected via a plug connection the operator must be able to control from any place to which it has access that the plug is removed If this is not possible due to design or installation the disconnection from the power supply must be ensured via locking in the disconnected position e g isolator gt The motor tube can get very hot during prolonged use When working on the unit do not touch the tube before it has cooled down v vvvvvyv www geiger de EN 3 EN 5 Safety instructions for assembly ATTENTION Important safety instructions Follow all installation instructions as incorrect installation can lead to serious injuries When mounting the motor without any mechanical protection of the driven parts and of the tube which may become hot the motor must be installed at a height of at least 2 5 m above the ground or of another level which provides access to the drive Before the motor is installed all cables which are not needed are to be removed and all equipment which is not needed for power operated actuation is to be put out of operation The actuating element of a manual release must be mounted at a height of less than 1 8 m If the motor is controlled by a switch or pushbutton the switch or pushbutton must be mounted within eyeshot of the motor The switch or pushbutton must not be located in the vicinity of moving parts The height of installation m
10. ions 1 Connect the connecting cable of the motor to the control switch 2 Move the awning to the required lower end position Any adjustment can be realized here 3 Move the awning to the upper position without any interruptions until the motor shuts down torque detection The programming procedure is then completed and the motor returns to normal operating mode Change the end positions 1 Extend the awning and activate the learning mode For this purpose retract the awning for 1 second wait 5 seconds extend the awning for 1 second wait 5 seconds retract the awning for 1 second wait 5 seconds retract again the awning for 1 second and wait 5 seconds 5s 5s 5s 5s gt break 5 break gt break gt break The motor always starts with a jerk when the learning mode is activated 2 Move the awning to the new lower end position Any adjustment can be realized here 3 Move the awning to the upper end position without interruptions until the motor automati cally shuts down torque detection The programming procedure is then completed and the motor returns to normal operating mode Note the motor can be programmed with any setting cable which allows a simultaneous UP and DOWN command The learning mode is activated by pressing simultaneously the UP and DOWN keys 3 seconds The motor confirms with 1 x click click Connection of the setting cable Hirschmann coupling Adaption cable Programming LED key
11. motor is suitable for shaft diameters from 50 mm EN www geiger de EN 5 EN 7 Information for the specialist electrician Caution Important installation instructions Please follow all installation instructions since incorrect installation can lead to the destruction of the motor and the switching unit The operations with the service clamps may be accomplished only by an electrical specialist Motors with electronic limit stops can be connected in parallel In this case the maximum load of the switching unit must not be exceeded When changing the running direction the switchover must be effected through an off position When changing the running direction the switchover time must be at least 0 5 s With a three phase network please use the same external conductor in order to control the UP and DOWN directions Connecting cables with plug connectors of the Hirschmann Company are tested and approved with couplings of the Hirschmann Company L1 N PE r Electronic mechanical limit stop Mains 230V 50Hz EN Gerhard Geiger GmbH amp Co KG 100W1512en V001 0613 8 Setting of the end positions The motor is in learning mode on delivery The motor jerks go stop go at each run command to confirm the learning mode activation The distance between the upper and lower end stops must be about 25 cm which corresponds to one tube rotation at least Programming the end posit
12. ue temperature changes modified winding behaviour should arise and the awning should run against the stop an immediate end position correction takes place 11 What to do if Problem Solution Motor does not run e Motor not plugged in Please check the plug connection e Check connecting cable for possible damage e Check the mains voltage and allow the cause of the voltage breakdown to be tested by a specialist electrician Instead of in the upwards direction motor The control leads are interchanged runs downwards Exchange black brown control leads Motor only runs in one e Motor in the end position direction Run motor in the opposite direction Re adjust the end positions if necessary After running several times The motor became too hot and has the motor breaks down and switched off no longer responds Try it again after a cooling time of about 15 min The motor jerks when starting runs The programming mode is activated The stops runs minimum travel distance has not been fully respected during programming 12 Maintenance The drive is maintenance free 8 EN Gerhard Geiger GmbH amp Co KG 100W1512en V001 0613 13 Declaration of conformity a GEIGER EC Declaration of Conformity Antriebstechnik Gerhard Geiger GmbH amp Co KG Antriebstechnik Schleifm hle 6 D 74321 Bietigheim Bissingen Product Venetian blind motor motor for rolling shutter motor for
13. ust be at least 1 5 m above the floor Permanently installed control devices must be attached visibly In case of devices extending horizontally a horizontal distance of at least 0 4 m must be respected between the fully extended part and any other fixed element The rated speed and the rated torque of the motor must be compatible with the device The mounting accessories that are used must be designed in accordance with the selected rated torque Good technical knowledge and good mechanical skills are necessary for the motor installation Incorrect installation can lead to serious injury Electrical work must be carried out by a qualified electrician in accordance with the regulations in force locally Only use connecting cables that are suitable with the environmental conditions and which meet the construction requirements see accessories catalogue If the device is not equipped with a connecting cable and a plug or other means for disconnecting from the mains with a contact opening on each pole according to the conditions of the overvoltage category Ill for full disconnection a disconnecting device of this type must be incorporated into the permanently installed electrical installation according to the wiring rules Do not mount the connecting cables near hot surfaces A plug for the disconnection of the motor from the power supply must be accessible after installation Damaged connecting cables must be replaced by GEIGER connecting

Download Pdf Manuals

image

Related Search

Related Contents

Intel Internet Station Network Card User Manual  Air-Conditioners  Manual del usuario de la cámara Analog Wedge TruVision  Manual de Instruções  O L Y M P IA NC 320  ilIgg 8U Series Spring Clamp Socket Operating Instructions  DeLOCK Sub-D 9 3m  Samsung GT-B5722 Εγχειρίδιο χρήσης  Ferplast 120 Suite User's Manual  Sony ADP-AMA Operating Instructions  