Home
Operating instructions - OPERTIS Produktkatalog
Contents
1. a ADD Master taught ar ea Dar Connect fitting Place IT Authorisation check in process 6 Fitting switched on 7 O O Change battery 8 O IT not authorised at the fitting 9 O ADD Master not recognised 10 O Fault in the fitting 11 az Fitting 30 sec without response 12 yof IT not placed for 30 sec 13 ESS OT Fitting does not belong to property o A M HEN HEN ee HE IT does not belong to property Long signal tone ss Battery warning Short signal tone en sound O Light flashes 02 2014 OPERTIS 15 GB eLOCK Case External power supply ES7781 Operating instructions 6 Servicing Cleaning and Maintenance The servicing cleaning and maintenance may be carried out by qualified personnel only Warranty cover is excluded for damage caused by improper handling Servicing The external power supply EPS requires no servicing Cleaning and maintenance CAUTION Risk of personal injuries The information transfer from the external power supply EPS to the fittings takes place via the EPS interface cable Heavy soiling or liquids such as water or oils can prevent communication so that it is possible for people to be locked in or out Check the interface cable for dirt regularly and if necessary clean CAUTION Damage to property due to incorrect cleaning Incorrect cleaning can cause the surfaces to be attacked and damaged O Do not
2. 3 volt lithium battery CR V3 Unlocking tool Screwdriver Cover lifter OPERTIS 5 GB eLOCK Case External power supply ES7781 Operating instructions Functional principle The external power supply EPS is used to supply power to fittings with completely flat batteries or fittings which following repeated battery warnings can no longer be actuated see eLOCK system documentation Battery Warnings section The EPS is connected to the fitting to be opened using the interface cable supplied Prerequisite for opening a fitting in an eLOCK lock system with the EPS is a taught MASTER IT or programming IT ADD An identifier authorised at the fitting is placed on the EPS and the opening is started at the press of a button The EPS supplies the necessary supply voltage to open the fitting The individual steps for the external power supply are indicated visually by the signalling LEDs on the top of the EPS as well as acoustically by an internal buzzer Detailed information Further information on the product is given in Section 8 Product Specifications 3 Intended Use Area of use The external power supply is designed for supplying power to electronic fittings with a flat battery ina OPERTIS lock system Condition of the product The external power supply may only be used if it is in a technically perfect condition Independent modifications and changes to the product are not allowed Ambient conditions
3. OPERTIS Operating instructions Case External power supply ES7781 eLOCK GB Operating instructions Case External power supply ES7781 Contents T INITOQUCHON nun ae ees eee eee ance ee cee ec eee eawecendeeondecseeed 4 ABOUT TNE SE NSE CTOMN S eine 4 Explanation of the Symbols and Signal Words USed cccsccccseeeeseeeeeeeeeeeeeesaeeeens 4 CJE OO UO areae OA EEO E 4 OPER TMS SUPPO rena AEE EE 4 Up to date status of the INfOrmatiOn cccccccccsseeecesceceseeceuceceueecseeeecseeeseueessueesseeeess 5 2 Product DESCHIDUON zu A a da ana aaa Eau een nungen 5 HWAGIWIGS GF TA CGIIN C1 ses 5 PUNCUOMAl BIINEIDIE 2a 6 Detailed INONMA N nanenane E DL 6 3 Intended USec a ec een aa aaa a wee eee 6 PAY SOT USO oE ne en E E E 6 COnGITION OF ING D odUC i serere rE EEEIEE EE 6 PAMDIENT CONGIIONS u a E E EE ESEE 6 Residuals Kasara AAEN E E O 6 4 Safety NSHUCHONS u u a u Ra En ERTAN 7 5 USE Ana Operaatio aac seien ia aia 8 glee gi DALE a eennenerer mee tear reeset ae ete E Soe ee eee eee eee ee 8 Teaching in the programming IT ADD and MASTER IT in EPS unen 8 Lost programming IT ADD or MASTER IT 2 0 eeccceececeeeeseeeeeseeeeseeeeseeeeseeesaaees 10 CONNEC internace CADIS a EEEE 11 Power supply carry out ODENING cccceececeececeeeeeeeeeeceeeeceeeeseueeseaeesseeeseeeeseueesaees 13 Delete teached in programming IT ADD or MASTER IT without teaching in a new IT ee 14 VISUAL ANG A
4. Use in a particularly polluted environment e g in aggressive gases high humidity in extreme temperatures or in a very dusty environment is not allowed If you have any questions please contact OPERTIS Support Residual risk lf used properly and if the maintenance instructions are followed this product will support your property security However the following residual risk cannot be excluded O lf the EPS or the interface cable is defective and the battery in the fitting is flat they cannot be used to open the door 6 OPERTIS 02 2014 eLOCK GB Operating instructions Case External power supply ES7781 4 Safety Instructions 02 2014 The following safety instructions must be read and followed before use OPERTIS does not accept any liability whatsoever for personal losses or injuries or damage to property caused by failure to note and follow these instructions WARNING Risk of personal injuries The tip of the screwdriver supplied is very sharp There is a risk of cuts or stab wounds Use the screwdriver only to remove the masking cap of the fitting After use return the holder to the case CAUTION Risk of locking in or out The battery can leak and damage the EPS so that it can then no longer provide any power supply for the fitting Check the battery each month for correct function and replace it with a new one each year CAUTION Risk of locking in or out lf there is a flat battery in the fitting
5. 3 sec ADD Master System 1 2 ADD Master taught If an error occurs during the teaching in procedure it is signalled by one long and one short sound and the red flashing ADD MASTER LED You should then proceed as follows O Determine and remove the cause of the error see Section 7 Problems and Solutions O Repeat the teaching in procedure ADD Signal tone Master System IT g U EEE Lost programming IT ADD or MASTER IT lf the programming IT ADD or MASTER IT is lost the respective replacement IT must be teached in in the EPS as described above Signalling key Long signal tone amaaa Battery warning sound O Light flashes Short signal tone 10 OPERTIS 02 2014 eLOCK GB Operating instructions Case External power supply ES7781 Connect interface cable Proceed as follows Step Activity Figure 3 Connect the connector of the interface cable to the EPS 4 Double knob cylinders und half cylinders Use a screwdriver to open the masking cap Framed door system Use a screwdriver to open the cover O Ole O Comfort system Comfort system for glass doors and APS comfot system O Use the screwdriver to carefully lever off the profile cylinder cover on the outside O Carefully remove the connector from the profile cylinder cover Ge I ann OPERTIS 11 GB Case External power supply ES7781 Step 5 12 OPERTIS Activity Lock cyli
6. COUSTIC Signals zu ana 15 6 Servicing Cleaning and Maintenance uuusnuanunnannunnnnnunnnnnnnnnnnunnnnnnnnnnnnnnnnnen 16 DIV IGier ee ee 16 Cleaning and maintenance 2 u00220000020nnennnnnennnnnennennennennennnnnnnnnnnennnnnennnnne nennen 16 7 Problems and Solutions sasssa a aN 17 8 Product Specilicallons iz aan anna eu 18 DEClaratl n 97 CONIOmIY asien 18 DIMENSION ren 18 NS CMG es Ca el aster chained ee 18 9 DISDOS 7 KERRERR SEN R HERDER ARE HANSER ESEANHEIDEERS SERSEEERUEESEEEEVERERSERIEBEESENIEREEEESHERSELESIERSERESSERSEEERIEREDEBEERERR 19 PIOQUE Lienen ae users 19 BAER Se ee 19 PIOQUELDAacKaa ng une eneiehe 19 02 2014 OPERTIS 3 GB eLOCK Case External power supply ES7781 Operating instructions 1 Introduction About these instructions These instructions contain important notes and information on operation of the external power supply EPS O Read through the instructions carefully and attentively O Keep the instructions in a safe place and pass them on to each subsequent user of the EPS Explanation of the Symbols and Signal Words Used WARNING Indicates risks which could result in fatal or severe personal injuries CAUTION Indicates risks which could result in fatal or severe personal injuries CAUTION Indicates risks which could result in damage to property Denotes information notes and tips on optimum use Note of the instructions and the product Target group Thes
7. accordance with WEEE Directive 2012 19 EU O Do not dispose of product by throwing it in the local household wasie O Return product to OPERTIS or dispose of at a municipal collection point for hazardous electrical wastes Batteries RX O Do not dispose of batteries in the local household waste but instead hand them in to public battery collection points O Do not throw batteries into a fire O Do not store used batteries together O Dispose of batteries only if they are discharged Product packaging Dispose of the product packaging in the local household and paper waste disposal system 02 2014 OPERTIS 19 OPERTIS Ce OPERTIS GmbH Prof Bier Stra e 1 5 D 34454 Bad Arolsen Telefon 49 5691 87741 0 Telefax 49 5691 87741 310 info opertis de www opertis de M7000 72GBB V007 02 2014
8. aching in the programming IT ADD and MASTER IT in EPS An identifier authorised at the fitting can only be used at the EPS ES7781 if a programming IT ADD or MASTER IT has been teached in at the EPS beforehand Before opening a fitting with the EPS an identifier authorised at the fitting must be placed on the EPS Note An already taught programming IT ADD or MASTER IT is automatically deleted in the EPS by the teaching in of a new programming IT ADD or MASTER IT 8 OPERTIS 02 2014 eLOCK GB Operating instructions Case External power supply ES7781 The signalling of the system states events and possible errors is given in section Visual and acoustic signals Proceed as follows Step Activity signalling Figure 1 Place the programming IT ADD or MASTER IT on the EPS 2a lf a programming IT ADD or MASTER IT has not yet been taught in the EPS the teaching in process must be started by briefly pressing the briefly ON button on the front ADD ER TEST System Signal tone 1 2 ADD Master taught Signalling key w Long signal tone amaaa Battery warning Short signal tone sound O Light flashes 02 2014 OPERTIS 9 GB eLOCK Case External power supply ES7781 Operating instructions Step Activity signalling i 2b If a programming IT ADD or MASTER IT has already been taught in the EPS and if this is to be replaced with a new one the ON button must be pressed for
9. ctive MASTER IT EPS is defective Replace EPS Fitting does not Fitting has not Repeat Steps 10 and 11 respond after recognised the new battery change or battery ni a flat Flat battery inserted in Insert fully charged ne fitting battery in fitting Further errors and the corresponding error messages are listed in the Visual and Acoustic Signals section OPERTIS 17 GB Case External power supply ES7781 eLOCK Operating instructions 8 Product Specifications Declaration of conformity OPERTIS GmbH herewith declares that the External Power Supply EPS fulfils the basic standards and other relevant specifications of the 1999 5 EG and 2011 65 EU directives and that they are CE compliant A copy of the statement of conformity can be ordered from the OPERTIS Support Dimensions All dimensions are given in mm Technical data Housing Colour black Material ABS plastic Specific data Supply voltage 3 volt lithium battery CR2 Operating and storage temperature Air humidity for operation and storage Degree of protection according to EN 60529 Class of protection according to DIN EN 61140 18 OPERTIS OPERTIS Art No ES0891 15 C to 45 C Note The external power supply must be stored at room temperature max 95 non condensing IP41 Ill safety extra low voltage 02 2014 eLOCK GB Operating instructions Case External power supply ES7781 9 Disposal Product X Disposal in
10. e instructions are directed at competent personnel entrusted with the servicing maintenance and disposal of trouble free operation of a OPERTIS lock system and who has successfully completed suitable vocational training for these activities or has had the necessary appropriate experience OPERTIS Support If you have any questions extending beyond the information provided in these instructions please contact OPERTIS GmbH Prof Bier StraBe 1 5 D 34454 Bad Arolsen Tel 49 5691 87741 200 Fax 49 5691 87741 281 E Mail support opertis de 4 OPERTIS 02 2014 eLOCK Operating instructions Up to date status of the information GB Case External power supply ES7781 All details on the product images dimensions and models correspond to the status at the time the product is delivered We reserve the right to make changes due to technical progress and the resulting continuous improvement process to which our products are subjected The current version of these instructions and further information is also available on our internet site www opertis de Dated 02 2014 2 Product Description Included in delivery The case is supplied with the following contents Part 02 2014 Nomenclature External power supply EPS 1 gt Contact area for identifier 2 gt Signalling LEDs 3 gt ON button 4 gt Clear button 5 gt Connection for interface cable ES7793 Interface cable 4 piece 3 volt lithium battery CR2
11. nder Insert the key of the interface cable Double knob cylinder Insert the jack plug of the interface cable Framed door system Insert the jack plug of the interface cable Comfort system Comfort system for glass doors and APS comfot system Insert the 2 pole plug connector of the interface cable on the outside of the door Figure eLOCK Operating instructions 02 2014 eLOCK GB Operating instructions Case External power supply ES7781 Power supply carry out opening The signalling of the system states events and possible errors is given in section Visual and acoustic signals Proceed as follows Step Activity 6 After teaching in the programming IT ADD or MASTER IT place an identifier authorised for the fitting to be activated on the EPS Any possibly existing time limit of the identifier is ignored 7 Press the ON button on the front side of the EPS Successful activation is signalled by a short sound and three green illuminated LEDs ADD Master 3 Connect fitting A Place IT System IT Signal tone 5 6 SE W Authorisation check in process 6 Fitting switched on Open the door Insert new battery in the fitting see separate operating instructions Signalling key w Long signal tone amaaa Battery warning Short signal tone Sr sound O Light flashes 02 2014 OPERTIS 13 GB eLOCK Case External power supply ES7781 Operating instructi
12. ons Note The following two steps are necessary so that the fitting recognises the new inserted battery This is not necessary for the ES7220 half cylinder 10 After teaching in the programming IT ADD or MASTER IT place an identifier authorised for the fitting to be opened on the EPS Any possibly existing time limit of the identifier is ignored Press the ON button on the front side of the EPS Successful activation is signalled by a short sound and three green illuminated LEDs 11 ADD Signal tone Master System a 3 gt _ Connect fitting Fa Place IT 5 3 X w Authorisation check in process 6 Fitting switched on Delete teached in programming IT ADD or MASTER IT without teaching in a new IT Proceed as follows Use a pointed object e g a paper clip to press the Clear button on the front of the EPS The deletion is signalled with a short sound Signalling key Long signal tone axana Battery warning sound Short signal tone ee O Light flashes 14 OPERTIS 02 2014 eLOCK GB Operating instructions Case External power supply ES7781 Visual and acoustic signals The EPS emits acoustic and visual signals for certain system states and events The following diagrams show the complete visual and acoustic signals They are also located on the back of the external power supply EPS ADD i t VERGE System Signal tone A Place ADD Master
13. the door can only be opened with an EPS or with the help of mechanical aids Ensure that a second fully charged battery or a power pack for the EPS is always available to ensure a power supply can be provided for the fitting CAUTION Unauthorised access Unauthorised persons can gain access with the programming IT ADD or the MASTER IT an identifier authorised at the fitting and EPS Ensure that authorised persons only have access to the programming IT ADD or the MASTER IT authorised identifiers and EPS OPERTIS 7 GB eLOCK Case External power supply ES7781 Operating instructions CAUTION Risk of malfunctions Unauthorised access An external power supply can only be provided from the outside profile cylinder cover without opening button in the Comfort System If the EPS is connected on the inside profile cylinder cover with opening button no external power supply is provided Lever handles coupled in Active Power Off remain coupled until an external power supply is correctly provided Therefore any person has access The external power supply must be connected to the outside of the door 5 Use and Operation Insert battery Note Note the battery type information in Section Technical data Proceed as follows Step Activity Figure 1 Open the battery compartment on the rear of the EPS 2 Insert the battery with correct polarity note the and markings 3 Close the battery compartment Te
14. use any alkali or acidic cleaning agents or cleaning agents containing chlorine O Do not use cleaning agents with scouring additives O Do not use scouring instruments e g brushes Proceed as follows Step Activity Figure 1 Wipe surfaces with a damp cloth 16 OPERTIS 02 2014 eLOCK GB Operating instructions Case External power supply ES7781 7 Problems and Solutions 02 2014 Problem Possible cause Solution External power EPS battery is flat or Change battery supply EPS does defective not perform any Foreign body in keyway Remove foreign body lock cylinder only activation Programming IT ADD Teach in the or MASTER IT not programming IT ADD or teached in MASTER IT Programming IT ADD Use the programming IT or MASTER IT does not ADD or MASTER IT of belong to the property the correct property Identifier is not Program identifier see programmed or does not eLOCK system have the necessary documentation software authorisations Fitting cable is defective Replace fitting cable Fitting cable is not Connect fitting cable connected EPS is defective Replace EPS Fitting is defective Replace fitting The programming The IT placed on the Place a programming IT IT ADD or EPS is nota ADD or MASTER IT on MASTER IT programming IT ADD or the EPS cannot be teached MASTER IT in Programming IT ADD Replace the or MASTER IT is programming IT ADD or defe
Download Pdf Manuals
Related Search
Related Contents
Sensor Enlite - Medtronic Diabetes 51709431/01 2.32Titelseite Archos Helium 4G 45 4GB 4G Black DIRCOM / - logiciels Manuel d`utilisation XCARLink Bluetooth Manuale CORAL-S Ed11 Draytek Vigor 2200E+ Case Logic XNF-116M LYNX Touch - GMS Système de sécurité Relatório Hotel Porto Grande Copyright © All rights reserved.