Home

Mounting and Operating Instructions Home station -

image

Contents

1. A 10 41 03 73 19 11
2. Mounting and Operating Instructions Home station hands free feature 1280 IRA Device description The Home station hands free feature is part of the Gira door communication sys tem and consists of the following compo nents 3 4 5 d 0006 00000 oo0oo0o0o0 t ooo0oo0oo0o l So alla le gt ola So a Sella ta LS 5 2 6 1 Door communication bus coupler 2 Audio connection cable 3 Speech insert 4 Cover frame not included in scope of supply al Loudspeaker top unit 6 Operating buttons for home station hands free feature Mounting A Attention nstallation and mounting of electrical devices may only be carried out by a qual ified electrician The Home station hands free feature is installed in two common flush mounted panel boxes Connect the door communication bus coupler to the 2 wire bus at the BUS terminals and if necessary the lines of Tr T the level call button to the ET termi Z nals BUS System 1 zv E ET 2 Insert the audio connection cable into one of the two System connectors of he bus coupler Video System 3 Guide the audio connection cable to he upper flush mounted panel box and install the bus coupler in the lower ush mounted panel box 4 Insert the audio connection cable into one of the two System connecto
3. matic function acts on the door opener of the door station from which the door call was triggered Function not active in factory setting To use the automatic door opener this function must be activated during com missioning Details are contained in the system manual Switching on automatic door opener 1 Simultaneously press the buttons X and for approx 3 seconds to switch on the automatic door opener S Y When the automatic door opener is switched on the LED gt lights up con tinuously The door opener is automati cally operated after a door call Switching off automatic door opener 1 Simultaneously press the buttons X and for approx 3 seconds to a switch off the automatic door opener o Y The O LED goes out i Behaviour after power failure Following a power failure the automatic door opener is switched off Acceptance of guarantee The warranty is provided in accordance with statutory requirements via the spe cialist trade Please submit or send faulty devices post age paid together with an error description to your responsible salesperson specialist trade installation company electrical spe cialist trade They will forward the devices to the Gira Service Center Gira Giersiepen GmbH Co KG Elektro Installations Systeme Postfach 1220 42461 Radevormwald Deutschland Tel 49 0 21 95 602 0 Fax 49 0 21 95 602 191 www gira de info gira de GIR
4. ncy for example M Meier o amp oe Setting call tone melody The Comfort home station offers five call tone melodies which can be individually assigned to the call buttons of the door station the internal call buttons of other home stations or the floor call button This allows for example a different door station call button with an individual call tone melody to be assigned in a household with several people e g parents chil dren The call tone melody is set as follows 1 Trigger the call tone whose melody you would like to change by pressing the corresponding call button which was previously taught in 2 To change the melody of the last trig gered call tone press and hold the x button on the home station and simul taneously press e the button to select the melody that follows or e the button to select the previous melody v Each time the buttons and are pressed a new call tone melody is set i Note When deleting the call button assignment to the home station the corresponding call tone melodies are reset to the factory setting 3s Automatic door opener The automatic door opener is e g used in doctor s offices when approx 4 s after pressing a door station call button the door opener is to be automatically oper ated If several door stations are presentin the system the auto
5. rs of he speech insert 5 Install the speech insert 6 Set the cover frame in place and attach the operating buttons and loud speaker top unit to the flush mounted inserts Start up Once you have installed all of the devices door and home stations control unit etc you can start up the door communication system Start up is described in the system manual included with the control unit Operation Operating buttons o a The following functions are executed with the operating buttons o lx Sy 0 Accepting a call If an incoming call is present the EN LED flashes for 2 minutes Briefly press the N button to start inter com communication with the person at the outdoor station The Sy LED illumi nates continuously during the intercom communication i Maximum conversation time The maximum conversation time is 2 min utes When this time expires the conver sation is automatically interrupted o Enforcement function If the background noises at the outdoor station are so loud that automatic switch ing of the speech direction is not guaran teed you can activate the enforcement function For this purpose press and hold the Sy button while speaking While the button is being pressed only the person at the Home station can speak and be heard To release the voice control to the door station release the Sy bu
6. tton again Ending the call To end the voice connection briefly press the Sy button The Sy LED switches off Opening the door Press the button If several doors are present the door opener whose door station made the door call is operated within 2 minutes lt switches to the main door 2 minutes after the start of the call or 30 seconds after the door call is ended Switching light on off only in conjunction with a switching actuator Press the 9 button to switch the light e g the outdoor or staircase illumination on Setting the speech volume The speech volume is changed to one of five levels during intercom communica tion Press to increase the speech volume Press to decrease the speech volume Setting the call tone volume The call tone volume is changed to one of five levels when no intercom communica tion is in effect Press to increase the call tone volume Press to decrease the call tone volume Deactivating activating the call tone Press the amp button to deactivate the call tone The amp LED illuminates continuously if the call tone is deactivated Press the X button again to reactivate the call tone The X LED switches off Only deactivate the call tone if necessary Deactivate the call tone in special cases only Otherwise the danger is present that you will not hear the ringing in an emerge