Home
EN DE Original-Montage- und Betriebsanleitung Original assembly
Contents
1. 1 The average sound pressure level data are intended for guidance only The values were determined by GEIGER at a distance of 1 m with a hanging motor at idle speed and averaged over 10 seconds There is no reference to any specific test standard 2 With angel gear GSI1 total length 52 mm weight 0 4 kg TA Subject to technical modifications C 10 EN Gerhard Geiger GmbH amp Co KG 100W1578en V000 0615 13 Declaration of conformity Antriebstechnik EC Declaration of Conformity Gerhard Geiger GmbH amp Co KG Antriebstechnik Schleifm hle 6 D 74321 Bietigheim Bissingen Product Venetian blind motor motor for rolling shutter motor for awnings Type designation GJ56 GR45 GU45 GSI56 The designated product is in conformity with the European Directive 2006 42 EC Directive 2006 42 EC of the European Parliament and of the Council of 17 May 2006 for the approximation of laws regulations and administrative provisions of the Member States concerning machinery 2004 108 EC Directive 2004 108 EC of the European Parliament and of the Council of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89 336 EEC The conformity of the designated product with the provisions of the directives is proved in particular by full compliance with the following standards DIN EN 60335 1 DIN EN 55014 1 DIN E
2. Antriebstechnik GEIGER System INline GSI56 e5 with electronic end stop for the facade technology on Original assembly and sapia t EN operating instructions EN Index 1 General information weissicisviccccsciinsieeseinsecsaveninndvesasestecniaaenevedvesse 2 E E TATT A micawerannenen 2 Sav Intended USE ciicvensiceescndacinsncaieadsenctvcicinetaddaandichetasinantaniecinansaaas 3 4 Safety instructions ccccceceeeeeeeeeeeeeeeseeeeeeeeeeeeeeeeeeeeeeeeeeneenees 3 5 Safety instructions for assembly ccccccceeeeeeeeeeeeeeeeeeeeeees 4 6 Assembly Note sirain ae an aaa raa audar aain asea Eana 5 7 Information for the specialist electrician 0 7 8 Setting of the end StOPS ccceeccssssseseeeeeeeeeeesssseeceeeeeeeesenees 8 95 OPO ratonn m ar a aaa skeet codeescvvstecsctesdtvecsdberedavseiversstedis 9 10 What to do Wi iccsetiicccnissndivececnsantet snciedennteseavnntend covadaneninsnaaweceiiene 9 Alo MAINO MAN CO an aree aa anana paataan aa rana aaea Aaaa Aisea 9 12 Technical dat est canrteearatuewiecetiiaarnruvactityuacindextaganpuensitvuasatenviagcens 10 13 Declaration of conformity ssssssnnsesnnnnnnnnnennnnnnnnnnnnnnnnnnnnnn 11 14 Notes on waste disposal cceeeceeeceeeeeeeeeeeeeeeeeeeeeeeees 12 1 General information Dear customer By purchasing a GEIGER motor you have decided on a quality product from GEIGER Thank yo
3. gt The installation is to be checked regularly for defective balance signs of wear or damaged cables and springs if relevant gt Do observe the moving sun protection system and keep persons away until it has closed completely gt When operating the manual release with the sun protection system open please be cautious as it can fall down quickly if springs or tapes wear off or are broken gt Do not operate the device if operations such as for example window cleaning are to be carried out in the vicinity Disconnect the automatic controlled device from the mains power supply if opera tions such as for example window cleaning are being carried out in the vicinity During operation observe the danger zone Do not use the installation if people or objects are in the danger zone Urgently shut down damaged installations until repair Unconditionally shut down the unit during maintenance and cleaning operations Pinching and shearing points are to be avoided and must be secured This appliance can be used by children aged 8 and above and persons whose EN physical sensorial or mental capacities are impaired or who have no experience or know how if they have been supervised or been given instructions on the use of the appliance and if they understand the possible resulting dangers Children are not permitted to play with the device Cleaning and maintenance should not be carried out by children gt The rated sound pressure level is less than
4. 70 dB A gt Disconnect the device from the mains power supply for maintenance and replace ment of parts If the motor is disconnected via a plug connection the operator must be able to control from any place to which it has access that the plug is removed If this is not possible due to design or installation the disconnection from the power supply must be ensured via locking in the disconnected position e g isolator gt The motor tube can get very hot during prolonged use When working on the unit do not touch the tube before it has cooled down v vvvvvyv www geiger de EN 3 EN 5 Safety instructions for assembly ATTENTION Important safety instructions Follow all installation instructions as incorrect installation can lead to serious injuries When mounting the motor without any mechanical protection of the driven parts and of the tube which may become hot the motor must be installed at a height of at least 2 5 m above the ground or of another level which provides access to the drive Before the motor is installed all cables which are not needed are to be removed and all equipment which is not needed for power operated actuation is to be put out of operation The actuating element of a manual release must be mounted at a height of less than 1 8 m If the motor is controlled by a switch or pushbutton the switch or pushbutton must be mounted within eyeshot of the motor The switch or pushbutton must not be
5. from the motor back cable Afterwards the Allen screws are tightened www geiger de EN 5 EN GSI56 e5 Parallel mounting In case of parallel mounting radial the motor is placed on the 7 mm hex insert of the connecting element Then the motor is directly fixed on the connecting element with four countersunk screws together with the angle gear EN Gerhard Geiger GmbH amp Co KG 100W1578en V000 0615 7 Information for the specialist electrician Caution Important installation instructions Mains 230V 50Hz Please follow all installation instructions since incorrect installation can lead to N the destruction of the motor and the PE switching unit A locking switch is here necessary no simultaneous UP l and DOWN commands l The operations with the service clamps may be accom l plished only by an electrical specialist Motors with electronic limit stops can be connected in parallel In this case the maximum load of the switching unit must not be exceeded When changing the running direction the switchover must be effected through an off position When changing the running direction the switchover time must be at least 0 5 s With a three phase network please use the same external z conductor in order to control the UP
6. N 61000 3 2 DIN EN 60335 2 97 DIN EN 55014 2 DIN EN 61000 3 3 DIN EN 62233 The accredited VDE Testing and Certification Institute EU Identification No 0366 Merianstr 28 D 63069 Offenbach tests and certifies for the company Gerhard Geiger GmbH amp Co KG Authorised representative for technical data Gerhard Geiger GmbH amp Co KG Address Schleifmihle 6 D 74321 Bietigheim Bissingen foaled Bese Bietigheim Bissingen 24 06 2015 Hans Michael Dangel General Manager www geiger de EN 11 14 Notes on waste disposal Recycling of packaging materials In the interest of environmental protection please contact your local government s recycling or solid waste management department to learn more about the services it provides Waste disposal of electric and electronic equipment Electrical and electronic equipment must be collected and disposed of separately in accordance with EU regulations EN For technical questions please call our service team at 49 0 7142 938 333 They will be happy to assist you A Gerhard Geiger GmbH amp Co KG GEIG ER Schleifmiihle 6 Antriebstechnik D 74321 Bietigheim Bissingen Telephone 49 0 7142 938 0 Telefax 49 0 7142 938 230 E Mail info geiger de Internet www geiger de 12 EN Gerhard Geiger GmbH amp Co KG 100W1578en V000 0615
7. and DOWN directions Connecting cables with plug connectors of the Hirschmann Company are tested and approved with couplings of the f Hirschmann Company l In order to prevent a malfunction caused by coupling i the supply line ref NYM from the actuator switch to l rcoccd Electronic mechanical limit stop the motor must not exceed 100m in case of motors with electronic end stops www geiger de EN 7 EN 8 Setting of the end stops The setting of the motor GF56 e5 can be realized with any switch allowing simultaneous UP and DOWN commands Part Nr GEIGER setting switch M56K144 With Hirschmann STAK3 connector D M56F150 With Hirschmann STAK3 connector CH M56F151 With terminal D M56B265 Adaptation cable with terminal and STAS3 M56E399 Adaptation cable with STAK3 and open cable ends Readjustment of the end stops The readjustment of the end stops can be carried out at any time in accordance with the instructions given below If there is no running of the blind by the operation points 3 and 5 the end stops have kept the same position as before Overload recognition The overload recognition is adapted to the given torque safety margin of the Venetian blind system by carrying out the complete adjustment procedure The blind must be moved by steps 3 and 5 Setting GJ56 e5 The order of the adjustment process must be strictly adhered to and the ad
8. he mains voltage and allow the cause of the voltage breakdown to be tested by a specialist electrician Instead of in the upwards direction motor runs downwards e The control leads are interchanged Exchange black brown control leads Motor only runs in one direction e Motor in the end position Run motor in the opposite direction Readjust teh end positions if necessary After running several times the motor breaks down and no longer responds After setting of the lower end position the blind only runs in DOWN direction The motor became too hot and has switched off Try it again after a cooling time of about 15 min The motor has been installed upside down see assembly note 11 Maintenance The drive is maintenance free EN www geiger de EN 9 12 Technical data Technical data GJ56 e5 with electronic end stop standard electronic Gsi5606r GSi5610r Voltage 230 V 50 Hz Current 0 40A 0 60A Cos Phi coso gt 0 95 Inrush current factor x 1 2 Power 93 W 135 W Torque 6Nm 10 Nm Speed 26 1 min Protection class IP 54 Limit switch range 200 rotations Operating mode S2 4 min Sound pressure level 34 38 db A 35 38 db A Length 301 mm 311 mm Diameter 55 mm Weight approx 1 50 kg approx 1 70 kg Ambient temperature Operation T 10 C 60 C H max 90 humidity Storage T 15 C 70 C dry and non condensing place
9. justment must always be completely implemented all steps 1 Connect the setting switch to the GJ56 e5 and then plug in power supply 2 Press the programming key till the LED flashes 1 flash light break 1 flash light break then release the programming key 3 Setting of the lower end position press the direction keys to exactly run the GJ56 e5 to the desired lower end position 4 Press the programming key till the LED flashes 2 flash lights break 2 flash lights break then release the programming key 5 Setting of the upper end position press the direction keys to exactly run the GJ56 e5 to the desired upper end position 6 Press the programming key till the LED keeps lighting The adjustment procedure is completed When using an external setting switch the UP and DOWN keys must be activated simultaneously instead of the programming key Instead of the lighting up of the LED the motor reacts with a short back and forth movement EN Gerhard Geiger GmbH amp Co KG 100W1578en V000 0615 9 Operation The GJ56 e5 can be operated with a standard locked Venetian blind switch Actuate the key UP to run the motor to the upper end position Actuate the key DOWN to run the motor to the lower end position 10 What to do if Problem Solution Motor does not run Motor not plugged in Please check the plug connection e Check connecting cable for possible damage e Check t
10. located in the vicinity of moving parts The height of installation must be at least 1 5 m above the floor Permanently installed control devices must be attached visibly In case of devices extending horizontally a horizontal distance of at least 0 4 m must be respected between the fully extended part and any other fixed element The rated speed and the rated torque of the motor must be compatible with the device The mounting accessories that are used must be designed in accordance with the selected rated torque Good technical knowledge and good mechanical skills are necessary for the motor installation Incorrect installation can lead to serious injury Electrical work must be carried out by a qualified electrician in accordance with the regulations in force locally Only use connecting cables that are suitable with the environmental conditions and which meet the construction requirements see accessories catalogue If the device is not equipped with a connecting cable and a plug or other means for disconnecting from the mains with a contact opening on each pole according to the conditions of the overvoltage category Ill for full disconnection a disconnecting device of this type must be incorporated into the permanently installed electrical installation according to the wiring rules Do not mount the connecting cables near hot surfaces A plug for the disconnection of the motor from the power supply must be accessible after installatio
11. n Damaged connecting cables must be replaced by GEIGER connecting cables of the same type The device must be mounted as described in the installation instructions Fixations shall not be made with adhesives since they are regarded as unreliable 4 EN Gerhard Geiger GmbH amp Co KG 100W1578en V000 0615 6 Assembly note Before fixing please check the strength of the facade and the subsurface Prior to installation please make sure that there is no visible damage to the motor like cracks or open cables The GSI motors are designed to be mounted on facade elements There are two versions e with bayonet lock for axial mounting Axial mounting to the bushing element GSI2 axial or similar In this case the motor is placed between the facade elements The flange with bayonet lock is used for easy and quick installation e with angle gear for parallel mounting Parallel installation on the facade element and fixation to the angle gear factory mounted In this case the motor is placed on one of the facade elements and is mounted on one of the connecting elements type GSI2 The connecting elements GSI2 and GSI2 axial are available in various penetration depths GSI56 e5 Axial mounting For axial mounting the connecting element is already aligned with the fagade element The drive is directed placed on the three screw heads of the connecting element bayonet lock and is then rotated clockwise viewed
12. u very much for your decision and the confidence placed in us Before you put this drive into operation please observe the following safety instructions It serves for the prevention of danger and for the avoidance of personal injury and damage to property The installation and operating instructions contain important information for the installer the specialist electrician and the user Please pass on these instructions if you transfer the product These instructions should be kept by the user 2 Guarantee In the case of incorrect installation contrary to the installation and operating instructions and or constructional modification the legal and contractual guarantee for property damage and product liability lapses 2 EN Gerhard Geiger GmbH amp Co KG 100W1578en V000 0615 3 Intended use The motors of the GSI 56 e5 series with electronic end stop are designed for operation with Venetian blinds that are within a fagade whereas the motor is outside the cavity The motors may not be used for the operation of roller grilles garage doors furniture and lifting tools GJ 56 xx x Design options Torque in Nm Motor diameter GEIGER INline System Safety instructions ATTENTION Important safety instructions For personal safety it is important to follow these instructions Please keep these instructions for future reference gt Do not allow children to play with stationary controls Keep remote controls away from children
Download Pdf Manuals
Related Search
Related Contents
none I 4506 Instructions / Assembly Document - Collège Paul Eluard GE BF60 User's Manual GE - GradiLux - Lighting Dimmer-Stabilizer Blinder 2 Single Row , CEGADORA 2 LAMP TR6.3 TREADMILL OWNER`S MANUAL iPeng 1.2.1 User's Manual Instructions d`installation F 1813 SF, F 1913 SF fr-CA Sales Quotation System User Manual Broker Version Integra Series Copyright © All rights reserved.