1. Toll Free 1 800 327 9403 air TOOLS Description Florida Pneumatic orbital sander is designed for medium duty applications such as sanding and finishing on a variety of surfaces including woods metals and fiber glass This tool features a powerful 1 2 horsepower motor with a built in regulator which allows convenient speed control during operation Safety Instructions The following instructions are furnished as general guidelines for use of your pneumatic tool They cannot compre hensively cover all possible or conceiv able uses of the subject tool For additional information on the safe use of air tools we advise you to obtain a copy of ANSI B186 1 Safety Code for Portable Air Tools available from the following source American National Standards Institute Inc 11 West 42nd Street New York NY 10036 The use of the word shall in the following instructions indicates that adherence to the particular require ment is necessary to conform to ANSI B186 1 Tool Application and Usage Portable tools shall be used only for the purposes intended in their design and within the capacity for which they were intended and rated It shall be the tool owner s and or employer s responsibility to instruct each operator in the safe use of the tool Tools shall not be used without guards and safety FP866A BLOCK SANDER devices as furnished by the manufac turer Where an air tool is modified or altered the m
2. AX PLEASE READ AND FOLLOW ALL WARNINGS Read Operating Instructions Always become familiar with all the instructions and warnings before operating any power tool Always Wear Approved Eye Protection Impact resistant eye protection should meet or exceed the standards as set forth in the United States ANSI Z87 1 Occupational and Educational Eye and Face Protection Look for the marking Z87 1 on your eye protection to insure that it is an approved style For further information ANSI 287 1 Occupational and Educational Eye and Face Protection is available from the American National Standards Institute Inc 11 West 42nd Street New York NY 10036 Hearing Protection is Recommended Hearing protection should be used when the noise level exposure equals or exceeds an 8 hour time weighted average sound level of 85 dBA Process noise reflective surfaces other tools being operated nearby all add to the noise level present in your work area If you are unable to determine your noise level exposure we recommend the use of hearing protection Avoid Prolonged Exposure to Vibration Tools can vibrate during use Prolonged exposure to vibration or very repetitive hand and arm movements can cause injury Stop using any tool if discomfort tingling feeling or pain occurs You should consult your physician before resuming use of the tool 90 PSIG Maximum This tool is designed to operate at an air pressure of 90 po
3. cements are warranted as described above for the remainder of the warranty period Florida Pneumatic s sole liability and your exclusive remedy under this warranty is limited to repair or replacement of the defective tool There are no other warranties expressed or implied and Florida Pneumatic shall not be liable for incidental consequential or special damages or any other damages costs or expense of repair or replacement as described above
4. odifier shall provide the safeguards to enable it to be safely used in the operations intended and to comply with any applicable provisions as contained in ANSI B186 1 Tool Installation Pressure regulators shall be used to limit air pressure to the rated pressure where the supply pressure exceeds the tool s rated pressure Air hoses and lines shall be relieved of compressed air before being disconnected or disjointed unless there is automatic valve closing protec tion at the joint being separated Syn thetic lubricants which can cause deterioration of elastomer seals shall not be used in air systems of air tools Tool Maintenance It shall be the tool owner s and or employer s responsibility to assure that tools are maintained in a safe operating condition Tool maintenance and repair shall be performed by authorized trained competent personnel Tools shall be disconnected from their compressed air supply before repairs are attempted Repairs shall be consistent with the manufacturer s recommended proce dures Tool hoses and fittings shall be replaced if unsuitable for safe operation It shall be the tool owner s and or employer s responsibility to keep required rating markings and warnings on the tool in legible condition Read these instructions carefully before attempting to install operate or service this Florida Pneumatic product Failure to comply with the instructions could result in personal injury and or
5. property damage Retain these instructions for future reference a FP866A Al R TOOLS BLOCK SANDER Specifications hs FP866A Al R TOOLS BLOCK SANDER FSU reese E O A A ecg pecs ce couse nee acy ees get nie aca cece sce atop etree ee ee sere eet eee econ MV VO NU eee ae esse cet acta ee E onset eit bee were eae ieee Length E Average air coneumptcn ingen E cee reepeesegnentecseenee RAC OMMEREN DOS CHE bd e E E en eater Tr 6 9866006 Throttle Valve 1 25 9866025 Gasket 1 Air ne SIZ racine Se a iaaiaee faee iaio 7 9866007 Retaining Ring 2 26 9866026 MountScrew 8 en ee 8 9866008 o Ring 2 f 27 9866027 LockWasher 4 9 9866009 Speed Regulator 1 28 9866028 Base 1 Limited Warranty Florida Pneumatic warrants its tools to be free from defects in material and workmanship for two year from the date of purchase This warranty does not apply to tools which have been abused misused modified or repaired by someone other than Florida Pneumatic or its authorized service centers If a Florida Pneumatic proves defective in material of workmanship within two year after purchase return it to any authorized service center or to Florida Pneumatic freight prepaid Please enclose your name address and adequate proof of purchase date with a brief description of the defect Florida Pneumatic will at its option repair or replace defective tools free of charge Repairs or repla
6. unds per square inch gauge pressure 90 PSIG maximum at the tool Use of higher air pressure can and may cause injury Also the use of higher air pressure places the internal components under loads and stresses they were not designed for causing premature failure The air supply should be clean and dry preferably lubricated For best results drain the moisture from your compressor daily WARNING Some dust created by power sanding sawing grinding drilling and other construction activities contains chemicals known to cause cancer birth defects or reproductive harm Some examples of these chemicals are e Lead from lead based paints o Crystalline silica from bricks cement and other masonry products e Arsenic and chromium from chemi cally treated lumber Your risk from these exposures varies depending on how often you do this type of work To reduce your exposure to these chemicals work in a well ventilated area and work with approved safety equipment such as those dust masks that are specially designed to filter out microscopic particles ay More than 1400 slope i I _ _ _ SSE T Branch line 2 times Taal inletthase size VF a a falve Lubricator So ep OO Eero i J Y U u Filter Main line 3 times nal in Regulator Ti Florida Pneumatic A Division of Florida Pneumatic Manufacturing Corporation 851 Jupiter Park Lane Jupiter Florida 33458