Home
Suncourt TW108 Instructions / Assembly
Contents
1. 6 6 Screws 6 Wall Anchors Operation Instructions The ThruWall is equipped with a two speed motor There is a three position switch on the output side of the fan The switches position I is low speed center O off and position Il is high speed STEP BY STEP INSTALLATION INSTRUCTIONS Step1 Place the metal sleeve without the grille attached against the wall with the flanged edge facing you Trace the pipe on the outside with a pencil to mark the cutout Refer to picture 1 Step 2 Cut out the circular opening with a small drywall saw Cut inside the pencil line Take care not to damage the edge of the drywall since you will be installing drywall anchors close to the hole to mount the grille Refer to picture 2 Step 3 Project the edge of the cutout onto the inside of the other wall board in three places approximately 120 apart Use a small square or a piece of cardboard that has an exact 90 angle to mark the cutout points on the inside of the other wall The two circular openings must be accurately aligned Refer to picture 3 Step 4 Use a small sharp pin or very small drill bit 1 32 or smaller to punch or drill these three marks to the outside of the other wall Refer to picture 4 Step 5 Place the other sleeve with grille attached against the outside of the wall and center its location using the three markers that you have made then trace the outside of the sleeve with a pencil Cut the circul
2. INSTALLATION INSTRUCTIONS FOR THRUWALL ROOM TO ROOM FAN MODEL TW108 uncover READ AND SAVE THESE INSTRUCTIONS IMPORTANT NOTICE WARNING To Reduce The Risk Of Fire Or Electric Shock Do Not Use This Fan With A Solid State Speed Control Device lb Lig tk With the use of any electrical appliance it is important to observe all basic precautions to minimize the risk associated with use such as electrical shock fire or injury to persons Read these instructions before using your ThruWall Room to Room Fan If you have doubts or are unfamiliar with this type of installation work seek the services of a qualified electrician Suncourt assumes no responsibility for installation of the ThruWall Fan Do not use a variable speed control with this product Suncourt does not provide electrical connection information For your safety and protection follow all instructions and adhere to applicable building and or electrical codes Not for bathroom use Do not use in wet locations Do not use in a window Do not install in fire rated walls Route the electric cord so that it cannot be tripped over Use only a grounded wall outlet WARNING To Reduce The Risk Of Fire Electric Shock Or Injury To Persons Observe The Following 1 Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction 2 When cutting or drillin
3. ar opening with a small drywall saw Cut inside the pencil line Take care not to damage the edge of the drywall You will be installing drywall anchors close to the hole to mount the grille Refer to picture 5 Step 6 Insert the metal sleeve with grille into the cutout opening fan output side and snug the flange up against the wall material making sure that power cord is hanging straight down Step 7 Insert the other metal sleeve into the cutout opening fan suction side and snug the flange up against the wall material Step 8 Position the unattached plastic grille over the metal sleeve that was just inserted so that the Suncourt logo is at the bottom and one of the mounting holes is in the top center Mark the location of all 3 wall anchors Make sure that the grille ribs are nicely square with the floor Step 9 Mark the position for the wall anchors on the grille Step 10 Remove metal sleeve with grille attached and drill the holes on both sides of the wall for the anchors with a sharp 3 16 drill bit Install wall anchors and after re inserting metal sleeve with grille attached screw the grilles down snugly DO NOT OVERTIGHTEN Refer to picture 6 Pic 2 Pic 4 Pic 5 CLEANING AND MAINTENANCE Before cleaning the TW108 ThruWall Fan unplug or switch power off at the appropriate breaker Dust may be removed from the exterior surfaces using a soft cloth the round brush attachment of your vacuum cleaner or
4. g into wall or ceiling do not damage electrical wiring or other hidden utilities 3 Not to be used with any solid state speed control E FE i te ETT TO kd Thank you for buying this Suncourt product The ThruWall fan moves air from room to room quietly and efficiently Simple to install in any frame wall from 3 1 2 to 6 1 2 thick A high quality Thermally Protected motor with balanced fan blade moves up to 200 CFM Move heated or cooled air between rooms PLEASE READ THESE INSTRUCTIONS BEFORE STARTING INSTALLATION The ThruWall can be mounted in any normal drywall or paneled stud construction wall up to 6 1 2 maximum total thickness Start by mana sure that there are NO studs water drain electrical or other obstruction in the wall where you wish to install the unit The power cord of the ThruWall is 10ft long please verify that the power cord will reach a 110 Volt AC outlet The use of extension cords is not recommended Please see the airflow direction label on the housing The grilles of your ThruWall fan may be pees to suit any decor Thoroughly wash the grilles with mild household detergent dry completely and spray with a quality fast dry spray paint The installation of your ThruWall fan is not difficult but the cutouts must be accurate In the carton you will find 1 Telescoping metal sleeve with plastic grille attached 1 Telescoping metal sleeve without grille attached 1 Loose grille
5. using a cloth that has been lightly moistened with water and a mild non abrasive detergent ONE YEAR WARRANTY Subject to the following limitations Suncourt Inc manufacturer warrants that the ThruWall Fan will for 1 one year from date of original retail purchase but not exceeding two years from date of manufacture remain free from appearance of defects in workmanship or materials This warranty is subject to the following limitations a manufacturer s liability is limited to the replacement or repair of the unit as decided by the manufacturer b a defective unit must be returned prepaid with proof of purchase well packaged to avoid damage in shipment and c this warranty does not apply to defects resulting from the alteration abuse accidental damage unauthorized repair or misuse of the unit This warranty is given in lieu of all other warranties guarantees and conditions on manufacturer s part and the manufacturer shall have no tortious or other liability in respect to this ThruWall Fan Actual product appearance may differ from illustrations Suncourt reserves the right to modify any or all of its products features designs components and specifications without notice SUNCOURT INC 500 WEST SECOND AVE DURANT IA 52747 1 800 999 3267 www suncourt com WNT108 0109 C01
Download Pdf Manuals
Related Search
Related Contents
Quick Assessment Tool for Planners and Community Leaders Basic Characteristics Data Petromax fb1 Computer Gear 26-2919 アフターサービス 取扱説明書 - デントロニクス 観測信号の分布に混合ガウス分布を、 音声信号の振幅の事前分布に Massive Suspension light 16271/86/10 201004 MAL Combipress 1_1_U.pmd - centra-pva Terminal Numérique Terrestre Free-To Copyright © All rights reserved.
Failed to retrieve file