Amana PTH123G35AXXX Installation Guide
Contents
1. Heating amp Air Conditioning PTAC AiR CONDITIONERS ana AND Heat Pumps PRODUCT SPECIFICATIONS 11 7 EER 3 4 COP Product Features K gt REFRIGERANT Quiet operation STC of 28 Assembled in the USA for 30 years Increased dehumidification capacity 100 run tested at our plant in Fayetteville TN for leaks 7 unit front depth one of the shallowest silhouettes Se in the industry today Removable condenser shroud allows easy access to enable regular cleaning of coils Easy pull out filters that are washable and easy to maintain Filter drier for sealed system refrigerant 7 Button touch pad provides complete control to guests for in room comfort while maintaining energy efficiency Condensate dispersion system removes condensate from indoor cooling operation and evaporates it into the atmosphere through the condenser Digismart front desk control amp energy management software Room freeze protection is activated when the unit senses temperatures of 40 F or below Versatile style that blends into any room s color scheme and decor Easy to service with on board led diagnostics Digismart wireless remote thermostat is available Remote temperature sensing for guest climate control Extended heat pump heating down to as low as 24 F outdoor ambient temperature Zero floor clearance allows unit to be installed flush to a finished floor 30 second fan off delay Compressor lock in prevents compressor short cy
2. topcoat enamel Sleeve must be insulated and shipped with a weather resistant rear closure panel installed OutDoor GRILLES Outdoor grille must be architecturally extruded louvered aluminum AGK01 B one piece polymer blend injection molded louver PGK01 B or standard stamped aluminum SGK B All other grilles must be submitted to the PTAC manufacturer for feasibility airflow characteristics and compliance with UL regulations where necessary The optional accessories listed below perform specific functions required in some installations Conpensate Drain Kit DK900D Attaches to the bottom of the wall sleeve for directional controlled internal or external disposal of condensate defrost or rain water Suspase Kit PTSB E Necessary for UL listing requirements for 265V units Hard Wire Kit may be substituted for Subbase kit Optional for 230 208V units Must be pre wired to facilitate field electrical connections and include an NEMA 6 or 7 configuration electrical receptacle It must have two leveling screws for sleeve support and accurate unit leveling during installation Locations for field installation of physical disconnect switches cartridge style fuse holders and circuit breakers must be provided Side skirts must be provided with sub bases PTSBOOOE Non Electrical Subbase available Power Vent amp Damper Must be provided to maximize ventilation air intake to up to approximately 95 CFM Power vent must be off a
3. ERANT cS 230 208 Vors HEATING CAPACITY PTH PTH PTH PTH 073E AXXX 093E AXXX 123E AXXX 153E AXXX cr 6 T 265 277 Vous HEATING CAPACITY PTH PTH PTH PTH 074E AXXX 094E AXXX 124E AXXX 154E AXXX Watts 58s 730 1365 cr 6 T z COP Coefficiency of Performance per ARI test procedures units are rated for capacities and efficiencies NOTES 1 All 265 volt models must use an Amana brand sub base PTSB4 E or an Amana brand hard wire kit PTPWHWK4 2 Minimum Circuit Ampacity MCA ratings conform to the National Electric Code however local codes should apply 3 Minimum voltage on 230 208 volt models is 197 volts maximum is 253 volts Minimum voltage on 265 volt models is 238 5 volts maximum is 291 5 volts 4 Overcurrent protection for all units without electric heaters is 15 amps Overcurrent protection on 265 volt models must be cartridge style time delay fuses included and factory installed on all Amana brand 265 volt chassis See heater performance for total MCA gt Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric heat at approximately 24 F outdoor ambient 6 Total watts for 12 000 and 15 000 BTU h models subtract 70 watts for PTO7 09 E A 7 Specify two digit heater kW size to complete model number 8 Total amps for 12 000 and 15 000 BTU h models subtract 0 2 amps for PTO7 09 E A 9 R 410A refrigerant used in all systems 10 All unit
4. Size 00 No Electric Heat 3 5 kW 230 208V 15 1 5 kW 3 7 kW 265V 25 2 5 kw 5 0 kw ERTE gt K A A ant PA ANO CERTIFIED ANO CERTIFIED AT www ahridirectory org www ahridirectory org A F fat Sas 0M ft San 080 1509001 C ListEo US Frauta 2 www amana ptac com SS DPTAC PRODUCT SPECIFICATIONS 230 208 Vous MopeEL 9 Voltage Capacity BTU h Amps Watts EER UNIT WITHOUT ELECTRIC HEATER Min Circuit Amps gt CFM Cool Wet Coil CFM Dry Coil Ventilated Air CFM Fan Only Dehumidification Pints Hr Net Weight Ibs Ship Weight Ibs 265 277 Vous Model amp 8 Voltage 3 Capacity BTU h Amps Watts EER UNIT WITHOUT ELECTRIC HEATER Min Circuit Amps gt 10 CFM Cool Wet Coil CFM Dry Coil Ventilated Air CFM Fan Only Dehumidification Pints Hr Net Weight Ibs Ship Weight Ibs on following page SS DPTAC PRODUCT SPECIFICATIONS PTC Mopeis Coounc Etectric HEAT High Low High Low E R 4104 SE REFRIGERANT 073G XXX 093G XXX 123G XXX 153G XXX ive IE 282 282 282 332 65 65 65 65 PB 102 102 113 113 117 119 130 074G XXX 094G XXX 124G XXX 154G XXX 265 290 290 290 340 264 264 264 314 310 310 310 360 282 282 282 332 65 65 65 65 PB 102 102 113 113 117 119 130 Approximately 95 CFM with optional power vent kit Actual vent CFM performance will vary due to application an
5. cling Constant fan mode Hidden ventilation control High pressure switch DieiSmor CONTROL BOARD 4 PARTS fy cero LIMITED WARRANTY Packaged Terminal AC AHAI Standard 310 380 E RTg 4 LIMITED WARRANTY p Al Standard 310 C o US LISTE First Year Warranty Parts amp Labor on entire unit Second through Fifth Year Parts amp Labor on certain sealed system components Second through Fifth Year on certain functional parts only Complete warranty details available at www amana ptac com SS DPTAC www amana ptac com 2 13 Amana is a trademark of Maytag Cot ion Supersedes 9 12 NOMENCLATURE 35 AXXX AA 8 9 10 11 12 13 14 15 Basic Model Type Engineering PTC Standard Cooler PTAC Major amp Minor Revisions PTH Standard Heat Pump PTHP DRY Dehumid Cooler PTAC Features Code Standard Model Corrosion Protection Seacoast Power Door Fuse Holder 230 208 Only Hydronic Heat Capable Condensate Pump PTH Only Quiet STC 31 Chassis RF Antenna Power Vent placeholder Hard Wired PTQC Cooling Capacity 07 7000 BTU h 60 Hz 09 9000 BTU h 60 Hz 10 10000 BTU h 50 Hz 12 12000 BTU h 50 or 60 Hz 15 14000 BTU h 60 Hz Rated Voltage 2 115V 60 Hz 1 Ph 3 230 208V 60 Hz 1 Ph 4 265V 60 Hz 1 Ph 5 240 220V 50 Hz 1 Ph as 2p Sa em amp Use up to 4 as needed in alphabetical order Design Series Examples G R 410A PTC123E50AXXX PTCO73E35CRXX PTC123E50CXXX PTCO73E25CQRW Heater
6. d ASHRAE 90 1 standards 9 All units less than 250 volts have a Leak Current Detector Interrupter LCDI power cord and meet UL 484 standards Refer to electric heat performance data for total MCA and recommended overcurrent protection Amps and Watts notation refers to compressor only witE RTE 4 Anad CERTIFIED Aa al CERTIFIED ARI Sana 31080 Ho Sanaa 10380 US ListEeo 4 www amana ptac com SS DPTAC PRODUCT SPECIFICATIONS Propuct Specirications PTH Mopets Cooune Heat Pump Evectric Heat R 410A F REFRIGERANT 230208 Vouts PTH PTH PTH PTH 073E AXXX 093E AXXX 123E AXXX 153E AXXX TEI 330 208 730 208 UNIT WITHOUT ELECTRIC HEATER MopeEL 9 CFM Cool Wet Coil os e e l 314 CFM Dry Coil Cw a a p 332 5 Dehumidification Pints Hr Co a f e 4 4 265 277 Voris Moon PTH PTH PTH PTH N T AXXX 154E AXXX Voltage 3 265 Capacity BTU h 7 2 5 000 11 Se 14 000 UNIT WITHOUT ELECTRIC HEATER 290 290 290 340 CFM Cool Wet Coil Low 264 264 264 314 CFM Dry Coil Ventilated Air CFM Fan Only 65 65 65 Net Weight Ibs 108 112 115 125 Ship Weight Ibs 123 127 132 142 Approximately 95 CFM with optional power vent kit Actual vent CFM performance will vary due to application and installation conditions See Notes on previous page SS DPTAC www amana ptac com 5 Propuct Specifications PTH Monets Reverse Cycie HEATING PERFORMANCE R 410A REFRIG
7. d installation conditions See Notes www amana ptac com 3 Propuct Specirications PIC PTH Mopets Evectric Heat PERFORMANCE Primary Heating for PTC Models Auxiliary Heating for PTH Models See below for Power Cord Configuration NOMINAL HEATING BTU H V ITA E ELECTRIC NO OF Nomar Hearine BTU H m TOTAL TOTAL MIN CIRCUIT MOP POWER HEAT KW STAGES WATTS AMPS AMPACITY AMPS CORD a 230V 208V 265V 230 208V Ps 8 500 6 800 2 570 2 115 115 i ees 6 15 P NOTES 1 All 265 volt models must use an Amana brand sub base PTSB4 E or an Amana brand hard wire kit PTPWHWK4 and disconnect switch PSHWO4A 2 Minimum Circuit Ampacity MCA ratings conform to the National Electric Code however local codes should apply 3 Minimum voltage on 230 208 volt models is 197 volts maximum is 253 volts Minimum voltage on 265 volt models is 239 volts maximum is 292 volts 4 Overcurrent protection for all units without electric heaters is 15 amps Overcurrent protection on 265 volt models must be cartridge style time delay fuses included and factory installed on all Amana brand 265 volt chassis See heater performance gt Heating capacity and efficiency based on unit operation without condensate pump unit automatically switches to electric heat at approximately 24 F outdoor ambient 6 Specify two digit heater kW size to complete model number 7 R 410A refrigerant used in all systems 8 All units meet or excee
8. n sensor e Wired room to room transfer fan e Front Desk Control e Future RF wireless communications devices Unit must be able to acquire and display operational temperature data from up to six installed thermistors to include e AT Indoor air temperature black e CT Indoor coil temperature red e DT Indoor discharge temperature yellow e OCT Outdoor coil temperature blue heat pumps amp Wire less cooler models e OAT Outdoor Air Temperature Wireless ready models only e Orange Miscellaneous thermistor or analog device optional EvaporaTor CONDENSER FANS Direct drive with a permanent split capacitor two speed indoor motor Condensate must be directed onto the back and sides of the coil to aid in evaporation and removal Air DISCHARGE Must be a sloped surface so that obstructions cannot be placed on the unit Discharge conditioned air can be directed into the room at an angle of 16 or 56 degrees from the vertical position The discharge grille must be of polycarbonate material to resist bending cracking rusting and corrosion www amana ptac com 7 PRODUCT SPECIFICATIONS New installations typically require a minimum of WS900D wall sleeve and an outdoor grille Watt Steeves WS900E The wall sleeve must be industry accepted dimensions 14 depth x 42 width x 1616 height and constructed of G90 HDG galvanized steel with a baked corrosion inhibiting urethane primer and baked polyester
9. nd damper door closed when unit fan is de energized Fuse Horner incLupep IN 265V chassis Must be installed either in the unit or the subbase and must match the electrical requirements of the chassis Security Key Locus KLO3E Must be installed to prevent tampering of the unit controls Unit room cabinet must also be secured to the chassis with field supplied screws UL approved for institutional use only Disconnect Switch Power disconnect switch must be installed in subbase for use as a physical disconnect where required by local codes Duct Kits MDKO1E EDKO2B TDKO2B PTDKO1E DDKO1E Three kits must be supplied to provide ducted conditioned air into a second room a main duct kit an extension duct kit and a terminal duct kit Hypronic Heat Kit Is required for heating functions instead of electric resistance heaters Unit must retain complete service access with the kit installed Proper water or steam valves must be used ConpensaTe Removal Pump Heat Pumps onty Must be installed to assist in removing the condensate developed by the heat pump operation and transfer it to the indoor coil to dissipate into the room adding humidity to the room Circuit BREAKER Kit Must be installed in subbase to provide overcurrent protection for proper 230 208V amperage Can also be used as a physical disconnect where local codes permit for 230 208 voltage Haro Wire Kit Must be used to permanently wire chassis for hard wire pu
10. rposes For 265V units Hard Wire Kit may be substituted with Subbase Kit THERMOSTATS A manufacturer approved manual auto changeover or programmable traditionally wired thermostat must be installed to provide full remote operation of the chassis A Remote Escutcheon Kit must be used to indicate remote operation Amana is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company L P All rights reserved Our continuing commitment to quality products may mean a change in specifications without notice 2013 e Goodman Company L P e Houston Texas Printed in the USA 8 www amana ptac com SS DPTAC
11. s meet or exceed ASHRAE 90 1 standards All units less than 250 volts have a Leak Current Detector Interrupter LCDI power cord and meet UL 484 standards 12 Refer to electric heat performance data for total MCA and recommended overcurrent protection Amps and Watts notation refers to compressor only 6 www amana ptac com SS DPTAC EE Contractor s Bip SHEET PRODUCT SPECIFICATIONS Furnish and install air cooled through the wall package terminal air conditioners amd heat pumps assembled in the USA Units are rated in accordance with the ARI Air Conditioning amp Refrigeration Institute Standards 310 380 93 CSA Canadian Standards Association EEV certification programs and listed by U L Underwriters Laboratories RATINGS Each unit must meet the following specifications ARI rating of BTUH cooling and BTUH reverse cycle heating with a COP of at 47 F O D Electric resistance heat of BTUH Total Amp draw must be of and Watts at volts The unit must remove a minimum of pints of moisture per hour when operated at rating conditions The EER must be a minimum of EER Unit Chassis Each unit must be slide out design shipped with room cabinet front installed Unit chassis must have the ability to be installed with O clearance from finished floor An electrical power cord must be included with chassis and installed by the manufacturer to assure proper NEMA 6 or 7 configuration and UL approved length Units less than 250 volt
12. s must also have a LCDI power cord Unit must be tested for conformance to ASTME water infiltration specification ASTME 331 86 which ensures no water infiltration when tested at 8 rain per hour at 63 mph wind for 15 minutes Room CABINET The monochromatic front of the room cabinet must be able to be field secured to chassis to inhibit tampering Filter must be accessible without removing room front Cabinet depth must not exceed 7 to minimize unit s impact on room space Coils Unit s coils must have rifled copper tubing expanded into rippled edge louvered aluminum fins Exterior coil must be of a two row bent coil design with removable shroud top to allow easy access for cleaning of the exterior coil Heat Pumps Each unit must include a change over thermistor that senses an outside ambient switch over temperature as low as 24 F lock open refrigerant reversing valve during heat pump operation temperature activated defrost drain and automatic emergency heat operation to override the heat pump s change over thermostat and bring on electric resistance heaters in the event of a sealed system failure Unit must not operate compressor and electric heaters simultaneously COMPRESSOR The compressor must be hermetically sealed internally isolated rotary type and permanently mounted on rubber isolators No removal or adjustment of compressor hold down bolts is to be required during installation WARRANTY The warranty is for F
13. ull One Year on the entire unit Full 2nd through 5th Year on the entire sealed refrigerant system components Limited Second through Fifth Year on functional parts only SS DPTAC Unit Dicitat CONTROLS The unit s control must be completely wired and accessible from the top of the chassis Controls shall be a LED touch pad design with seven large easy to read and use buttons Heat Cool Off Fan Temp plus Temp minus and two red seven segment LED temperature displays Unit shall have a green status LED to advise owner of operational diagnostic messages Unit shall have one button activation via membrane touch pad Unit control board shall have an 18 pin low voltage connector to allow for easy connection to remote wired devices Unit shall have two serial port connectors for easy connection to wired or wireless EMS Energy Management Systems Unit must have the ability to easily configure owner selectable and programmable functions e Fan cycle operation e Electronic temperature limiting for cooling e Electronic temperature limiting for heating e Enhanced dehumidification cooling operation e Unoccupied 18 hour temperature set back e Un rented temperature set back e Multiple unit twinning to one wired thermostat e Load shedding operation e Front desk on off or temperature set back Unit must be able to connect to approved remote devices e Wired thermostat e Wired door motion sensor e Wired room motio