1. CAUTION iP For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 Not for use in cooking areas Fig B 3 This product must properly connect to the grounding conductor of the supply circuit 4 To reduce the risk of injury to persons install the fan at least 7 feet 2 1m above the floor Cooking area A Do not install above or l inside this area a QO ar eae aoe ae Cooking Equipment 2 floor Fig B SUPPLIED ACCESSORIES Duct Connector oreez GreenBuilder MODEL GBR80LED Page 1 1 INSTALLATIONS MOUNT HOUSING WITH FLANGE 1 1 To bend the housing tabs out to 90 degrees and make housing tabs contact the bottom of the joist j Y A 1 2 The housing mounts with 4 screws 4x25 Screw housing to joist through lowest holes in each mounting flange then through the other holes f Joist ill S Se Il WE WA ca Screw 4x25 USING SUSPENSION BRACKETS SOLD SEPARATELY 1 3 Sliding suspension brackets available to allow for your specific positioning of housing anywhere between joists and span up to 24 1 4 Insert suspension brackets into the channels on housing Make sure tabs face up shown Suspension Bracket Sold separately 1 5 Extend suspension brackets to the width of the joists Hold fan in place with the suspension brackets tabs wrapping aroun
2. A NELTA INSTALLATION AND OPERATING INSTRUCTIONS VENTILATION FAN LED LIGHT READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION 1 Make sure that the electric service supply voltage is AC 120V 60Hz 2 Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occupational Safety and Health Act OSH Act 3 Always disconnect the power source before working on or near the ventilating fan motor or junction box 4 Protect the power cord from sharp edges oil grease hot surfaces chemicals or other objects Do not kink the power cord 6 Do not install the unit where ducts are configured as shown in Fig A 7 Provide suction parts with proper ventilation 8 This unit is UL listed for use over a bathtub or shower when installed in a GFCI protected branch circuit 9 These ventilating fans are intended for residential usage only WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer 2 Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 3 Ins
3. RS 30000 MIN TRANSIENT PROTECTION CLASS A OPERATING FREQUENCY HZ 120 FCC QUALIFIED YES ENERGY QUALIFIED YES ROHS QUALIFIED YES SAFETY REQUIREMENTS UL cUL Asp breez GreenBuilder MODEL GBR80LED Page 2 WARRANTY DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY Delta Electronics Inc Delta Electronics warrants to the original consumer purchaser in the USA that the Breez ventilation fan products will be free from defects in material or workmanship This warranty is limited to three 3 years from the original date of purchase Limitations and Exclusions 1 O N During the warranty period a replacement for any defective product will be supplied free of charge for installation by the consumer The warranty provided herein does not cover charges for labor or other costs incurred in the troubleshooting repair removal and installation service All returns of defective parts or products must include the product model number and must be made through an authorized Delta Electronics distributor Authorized returns must be shipped prepaid Repaired or replacement products will be shipped by Delta Electronics F O B shipping point Delta Electronics shall not be liable for any indirect incidental consequential punitive or special damages arising out of or in connection with products use or performance regardless of the form of action whether in contract tort including negligence strict
4. d the bottom of joist 1 6 Fasten suspension brackets to joists with nails or screws through holes near nails 1 7 Secure suspension brackets together with Screws Bottom of joist A NELTA 2 DUCT CONNECTION 2 1 Insert the duct not provided into the duct connector and tape all ductworks connection to make them secure and air tight Install the duct with a gradient 1 2 to the outside Inside Outside Duct Connector Tape Body Duct Ceiling vos Grille 3 CONNECT WIRING 3 1 3 2 LIGHT BLU SWITCH e FAN SWITCH C e LINE WHT 3 4 3 5 Follow all local electrical and ANSI NFPA70 NEVER place a switch where it can be reached from a tub or shower LIGHT WHT BLUE BLK FAN WHT BLK BLK e e e LIGHT FAN ELECTRICAL BOX GRD HOUSE ELECTRICAL BOX Connect wires as shown in wiring diagrams Use wire nuts not provided and connect house power cable to ventilating fan 14 AWG 2 1 mm is the smallest conductor that shall be used for branch circuit wiring 4 TEST RUN amp GRILLE ATTACHMENT 4 1 4 2 4 3 Insert the LED lighting connecting into the power socket of main body as below shown When the power on check for abnormal vibration or sound Insert the mounting springs into th
5. e slots and mount the grille to the fan unit Lighting Connector Grille 5 OPERATION 5 1 Turn on the power switch to operate ON or OFF and LED indicator is green 6 MAINTENANCE WARNING Disconnect power source before working on unit Routine maintenance must be done every year CAUTION i Never use gasoline benzene thinner or any other such chemicals for cleaning the ventilating fan Do not allow water to enter motor 3 Do not soak resin parts in water over 60 C CLEANING 1 Pull down the spring to remove grille 2 Clean grille Use non abrasive kitchen detergent wipe dry with new cloth 3 Use a cloth dampened with non abrasive kitchen detergent remove dust and dirt from ventilating fan Wipe dry with new cloth 4 Replace grille DIMENSIONS 10 75 4 DUCT 0 84 5 75 l D 10 75 i LY ape ii KS A fr SPECIFICATIONS FAN Power Power Air Flow Model No onde eY 018P o 1sp eo W CFM i W GBR80LED 120 60 11 6 80 6 1 10 0 Note Design and specifications subject to change without notice SPECIFICATIONS LED LIGHT ENGINE ITEM SPEC DIMENSION INCH 8Lx4 4Wx1 4H POWER CONSUMPTION W 11 CORRELATED COLOR TEMPERATURE K 2700 LIGHT SOURCE LIFE HOU
6. product liability or otherwise This warranty does not extend to fluorescent lamp starters and tubes The warranty does not cover if user does not comply with manufacture s installation manual To qualify for warranty service you must notify Delta Electronics at the address or telephone number below Delta Electronics shall have no liability to the original owner user with respect to any defect caused by abuse misuse neglect improper transportation or storage improper testing improper installation improper operation improper use improper maintenance improper repair improper alteration improper modification tampering or accident of products or parts thereof or unusual deterioration or degradation of products or parts thereof due to a physical environment beyond the requirements of products specifications Address 4405 Cushing Parkway Fremont CA 94538 US Toll Free Number 1 888 979 9889
7. tallation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit 8 Do not use this unit with any other solid state control devices Solid state control devices may cause harmonic distortion which can cause a motor humming noise 9 NEVER place a switch where it can be reached from a tub or shower 10 Notto be installed in a ceiling thermally insulated to a value greater than R40 This is required for installation in Canada only Turning angle too large Duct shrink Too many elbows Elbow near the body L Fig A 9S
Download Pdf Manuals
Related Search
Related Contents
D_Mostab, Version 5 Manuale per la messa in servizio - Service, Support Istruzioni Kondator 459-3015 wrist rest Graco 339380EN-A User's Manual Integrated Environmental Control Model: Getting Started Samsung LD220HD User Manual Acer TravelMate 7510 Owner's Manual User manual Copyright © All rights reserved.