Home
Battic Door Energy Conservation Products MTM Instructions / Assembly
Contents
1. IAL DAMAGES IRRESPECTIVE OF THE CAUSE THEREOF OCCUR RING EITHER DURING OR AFTER THE WARRANTY PERIOD INCLUDING WITHOUT LIMITATION ANY DAMAGE TO ANY PART OF A BUILDING OR ITS CON TENTS NOTE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES AND SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE PROOF OF PURCHASE REQUIRED Tamarack N Technologies Jnc _ _ 320 Main Street e Buzzards Bay Ma 02532 Ventilation Solutions 5 98 759 4660 800 222 5932 Fax 508 759 6001 www tamtech com 4 P N MM 5
2. MIAINS T REAM PRODUCT MANUAL amp INSTALLATION GUIDE Please note the serial number date of pur chase and the point of purchase below for handy reference The serial number is located on a label affixed to the Mainstream Serial Number or Code Number Date of Purchase Point of Purchase This fan was tested in accordance with figure 12 of ANSI ASHRAE standard 51 07 AMCA 300 08 and HVI Standard 915 916 Ter Unpacking your Mainstream One 1 Ventilation Fan Direct Replacement Ventilation When you have unpacked One 1 Inner Grille Ring system for Manufactured Housing Ou MAEA ee ee will find the following Two 2 Wire Nuts READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction b Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refridgeration and Air Conditioning Engineers ASHRAE and the local code authorities c When cutting or drilling into wall or ceiling do not damage electrical wiring an
3. d other hidden utilities d Ducted fans must always be vented to the outdoors e If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit f Use this unit in the manner intended by the manufacturer If you have any questions contact the manufacturer g Before servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service disconnecting cannot be locked securely fasten a prominent warning device such as a tag to the service panel h Never place a switch where it can be reached from a tub or shower i Do not use this fan over cooking appliances CAUTION For General Ventilation Use Only Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages AN marack 4 recess lesne a Yntilation Solutions 222 Main Street e Buzzards Bay Ma 02532 www tamtech com 508 759 4660 800 222 5932 Fax 508 759 6001 INSTALLATION INSTRUCTIONS If you have any questions call 800 222 5932 RETROFIT INSTALLATION 1 Ensure that all power is turned off at the unit 2 Remove the old fan WARNING State and local electrical c
4. odes may 3 Ensure that the roof cap is unobstructed require that the Mainstream be installed by a licensed 4 On the Mainstream remove the electrical box electrician Check with your local code cover by removing the two screws on the fan housing Officials before installing Slide in the Mainstream making sure that the source electrical wires are fed into the electrical box and that the Romex clamp is tightened MAINSTREAM l 6 Connect the wires by twisting each pair together Mainstream and then installing a wire nut over them 7 Screw through both the Mainstream and grille ring to attach the housing to the ceiling using original hardware and hole locations if possible 8 Re install the electrical box cover 9 Attach the grille to the grille ring NEW CONSTRUCTION 1 Provide a 7 diameter rough opening in the ceiling Notch a 2 x 3 34 opening for the electrical box 2 Ensure that the roof cap is unobstructed 3 On the Mainstream remove the electrical box cover by removing the two screws on the fan housing 4 Slide in the Mainstream making sure that the source e are pe into ip clara box 65 cfm 1 Wg and that the Romex clamp is tightened 5 Connect the wires by twisting each pair together and 120 Volts 16 Watts 2 Amp then installing a wire nut over them 3 Sones 6 Screw through both the Mainstream and grille ring to attach the housing to the ceiling 7 Re install the electrical box cover 8 Attach
5. the grille to the grille ring O1 LIMITED WARRANTY IF WITHIN THE PERIOD OF 1 YEAR FROM DATE OF PURCHASE THE MAINSTREAM THE PRODUCT IS DEFECTIVE OR MAL FUNCTIONS IN NORMAL HOME USE TAMARACK WILL REPAIR OR REPLACE THE MAINSTREAM AT ITS DISCRETION WITHOUT CHARGE FOR LABOR OR MATERIALS CUSTOMER IS RESPONSIBLE FOR SHIPPING CHARGES CONDITIONS EXCLUSIONS AND LIMITATIONS THIS WARRANTY IS SUBJECT TO THE FOLLOWING CONDITIONS EXCLUSIONS AND LIMITATIONS THIS WARRANTY DOES NOT COVER PROBLEMS RESULTING FROM INSTALLATION OPERATION OR MAINTENANCE THAT HAS BEEN UNDERTAKEN OTHER THAN IN ACCORDANCE WITH THE INSTRUCTIONS THIS WARRANTY DOES NOT COVER PROBLEMS RESULTING FROM DEFECTS IN OR CAUSED BY ASSOCIATED EQUIPMENT FURNACES SOLARIA ETC FROM REPAIRS OR MODIFICATIONS ATTEMPTED BY PERSONS OTHER THAN TAMARACK FROM ABUSE ACCIDENTAL OR SHIPPING DAMAGE ACTS OF GOD THIS WARRANTY DOES NOT APPLY TO THE PRODUCT USED OUTSIDE THE UNITED STATES ITS TERRITORIAL POSSESSIONS AND CANADA EXCEPT AS SET FORTH ABOVE NO EXPRESS OR IMPLIED WAR RANTY IS GIVEN OR AUTHORIZED BY TAMARACK AND ALL OTHER SUCH WARRANTIES ARE EXPRESSLY DISCLAIMED ANY WARRANTY OR MER CHANTABILITY OF FITNESS FOR ANY PARTICULAR PURPOSE SHALL BE LIMITED TO THE WARRANTY HEREUNDER MOREOVER ANY LIABILITY OF TAMARACK FOR THE PRODUCT SHALL BE LIMITED TO THE REPLACEMENT OF THE PRODUCT IN NO EVENT SHALL TAMARACK BE LIABLE FOR ANY INCIDENTAL DAMAGES OR FOR ANY CONSEQUENTIAL PROPERTY OR COMMERC
Download Pdf Manuals
Related Search
Related Contents
Betriebsanleitung PDF - 820.5 ko - Université Blaise-Pascal, Clermont User Manual & Installation Guide 新しいワイヤ放電加工機の性能評価 Hot Food Deli Case - Whaley Food Service RCA VH915 User's Manual Istruzioni per il montaggio 161209 7084276 Questionnaire du personnel soignant - Compaq-HPST Copyright © All rights reserved.