Home
SPT SF-610 Use and Care Manual
Contents
1. SPT Instruction Manual Evaporative Air Cooler Y It is important that you read these Model No SF 610 instructions before using your new cooler and we strongly recommend that you keep in a safe place for future reference 9 7 moo w Pp CONTENTS PRODUCT INTRODUCTION ococcoconccnnnnconconnnnnonnnnnnnnnnnnannnos BRIEF INTRODUCTION OF FEATURES ccceeceeeeeeeeee eee CONTROL PANEL AND PARTS IDENTIFICATION 00 006 OPERATING INSTRUCTIONS AND FUNCTIONS 00088 CARE AND MAINTENANCE 00cceceeseeeseeeeeeeseeeeneeeeeneeee CAUTION TECHNICAL PARAMETER cccceseeeeeeeeeeeeeeeeenseeeeesensenes DEFECTIVE NOTICE civoxaocionion cinco WARRANTY oido ido A PRODUCT INTRODUCTION The Evaporative Air Cooler is capable of providing various types of airflows quiet and soft air like the spring breeze fresh air simulating the Coastal breeze cool damp air like after a rainfall The different type of airflows will accommodate your needs to provide a comfortable environment and reduce the heat of summer The humidifying function will help keep your skin in good condition The lonizer feature cleans the air for a pure and clean breathing space Thank you for purchasing SPT Evaporative Air Cooler To have an in depth understanding of the product and to ensure its proper usage please read this instructio
2. en E CARE AND MAINTENANCE Always unplug the unit before cleaning and maintenance After a period of operation the filter and water curtain may become clogged with dust or dirt which will greatly affect the performance of the unit It is recommended to clean the filter and water curtain once every two weeks e Clean exterior panels using a soft damp cloth with a mild cleanser Never use strong chemicals oil based products detergent chemically treated cloths or other strong cleaning solutions Filter 1 Slide filter upwards to remove 2 Clean with vacuum cleaner s brush attachment or wash under lukewarm water Dry completely before replacing Fig 5 Water Curtain 1 Remove 6 screws on the back panel 3 on each side Fig 6 2 Remove water tube connection at upper left corner as you face the back of the unit 3 Remove water curtain at Velcro closure 4 Wash with warm water and gentle cleanser Affixing position of water curtain STORAGE If you do not plan to use the unit for a long period of time drain out all water and clean the water tank filter and water curtain Operate the unit in normal fan mode for approx 30 60 minutes This will dry the interior and prevent mold growth It is recommended to pack the unit in its original box and store in a dry cool place CAUTION 1 Use standard supply of 120V 60Hz Plug unit into dedicated socket with rating of more than 3A All sockets should comply with Na
3. n addition to your Statutory Rights
4. ns manual thoroughly especially the relevant information marked Warning and Caution BRIEF INTRODUCTION OF FEATURES High quality computer controlled system Mechanical and full function remote control operation Features humidifier air filter and lonizer The composition of filter water curtain and ionizer produces fresher air Supplies moisture to the environment in dry climates 0 5 to 7 5 hour timer Ice compartment for extra cooling 00 SEN 102s Oi hte a a Oxygen Bar with Negative lons Negative ions have the effect of cleaning the air providing you a clean healthy surrounding 9 Three air modes and three fan speeds to select from 10 120 oscillating sweep angle cools maximum space 11 Energy efficient input power of 60W C CONTROL PANEL AND PARTS IDENTIFICATION 1 Control panel and remote functions Fig 1 Fig1 control panel 2 Construction diagram Fig 2 Fig2 3 Accessories included e Remote Control 1 e Instruction Manual 1 D OPERATING INSTRUCTIONS AND FUNCTIONS 1 Unpack and remove all packaging materials 2 Check contents and see that all accessories are included 3 Place unit on a flat sturdy surface Make sure there is no tilt during operation 4 Check the power supply and refer to the rating label at the back of the unit 5 Functions ON OFF Press once to turn unit ON Power indicator light will illuminate Press again to turn unit OFF SWING P
5. r not working properly Please DO NOT return to your retail store Please contact us directly with any Service or Technical Assistance Contact us toll free at SUNPENTOWN INTERNATIONAL INC 909 468 5288 21415 Baker Parkway City of Industry CA 91789 SPT Evaporative Air Cooler Model SF 610 Your Guarantee If this product is found to be faulty as a result of faulty materials or workmanship within one year from date of purchase it will be repaired free of charge This guarantee is subject to the following terms e Sunpentown must be notified of the fault e Proof of purchase must be presented to Sunpentown s nominated representative e The warranty will be void if the product if modified misused or repaired by an unauthorized person e The warranty after repair will not be extended beyond the original one year period e All replacement parts will be new or reconditioned e Parts which are replaced become the property of Sunpentown e The warranty applies for the use of the product in the USA only What is NOT COVERED e Warranty does not include freight charges e Incidental or consequential damage caused by possible defects with this product e Damage to product caused by improper power supply voltage accident fire floods or acts of nature e Failure of product resulting from unauthorized modifications to the product e Improper installation or failure to perform the necessary maintenance This GUARANTEE is i
6. ress once to have the louvers swing automatically in a left to right motion Swing indicator light will illuminate The louvers will swing in continuous range of 120 Press again to stop auto swing for fixed air direction To adjust vertical airflow manually move the long Air Guide Blade up or down SPEED Press to choose your desired fan speed High Medium Low The corresponding indicator light will illuminate TIMER Press to set timer in increment of 5 hours from 0 5 to 7 5 hours Indictor lights that illuminate add up to the set time For example a timer of 7 hours will have the following indicator light on 1H 2H and 4H If timer is not set unit will run continuously COOL Press once to start the evaporative cooling function COOL indicator light will illuminate Make sure water is added before turning on this function Unit will begin to cycle the water and blow cool humidified air Press again to stop this function and unit will run in normal fan mode Note If water is not added or runs empty in Cool mode unit will run as normal fan mode but the Cool indicator light remains on Once water is added unit will run in COOL mode again MODE Press to select one of three computer controlled airflows Unit starts in Normal mode no indicator lights on Press once for Natural mode Natural indicator light will illuminate this mode turns the fan on and off to simulate a outdoor breeze Press again for Sleep mode Sleep indica
7. tional Standards 2 After filling with water the Evaporative Cooler should not be tilted If you need to move the unit push gently and slowly on the side to avoid water spilling Fig 8 3 Do not place heavy objects on top of the unit Do not obstruct the air outlet Keep a minimum space of 6 inches around the unit Fig 9 4 Suitable ambient temperature range is 40 F 100 F When temperature is high change water frequently to prevent mildew and mold growth Do not place unit under direct sunlight or near a heat source Never clean unit under running water or immerse unit under water Fig 10 Always unplug unit when not in use O 0090 To avoid risk of shock the product should never be used in bathrooms shower rooms or other wet areas 10 If the power cord is damaged contact the manufacture or a qualified electrician 11 Do not use the COOL function if unit is used in a damp and closed space 12 Unplug unit before servicing or maintaining 13 Never push fingers or objects into the louver Fig 11 14 Basic precautions should be taken when operating unit near young children Fig8 Fig11 G TECHNICAL PARAMETER Main technical parameter Rating voltage frequency 120V 60Hz Input power 60W Water consumption 0 5 0 6L h Max air volume gt 20m min Fan Speeds 9 N W 16 5 Ibs Dimension 12 01 x 9 45 x 28 35 in DEFECTIVE NOTICE If this product is defective o
8. tor light will illuminate this mode works like Natural mode but it will lower the set fan speed after approximately 30 minutes if set on medium or high You can select your desired fan speed in any of these modes e JONIZER Press to turn on the ionizer function lonizer indicator light will illuminate Unit will begin to release negative ions into the air Press again to turn off this function REMARK When unit is turned off the Power indicator and lonizer indictor if function was on will stay lit All settings will be resumed except the timer when powered back on Before running unit in COOL mode add clean water through the Water Inlet or through the side door Keep an eye on the Water Level Indicator and do not fill over the Maximum line Water level can also be noted through the side door The power supply should be disconnected before filling to prevent electrical parts from damage For maximum cooling add ice directly into A water tank through side door or in the top Ice Compartment Fig 3 and 4 When adding water or ice to the top compartment add only into the corresponding box of ICE ONLY or WATER ONLY When water level runs low near the MIN line add water immediately to continue the cooling effect The remote control functions the same as those on the control panel To use the remote point the remote s infrared emitter towards the Evaporative Cooler There should be no obstructions in betwe