1. Centrax Print INSTALLATION INSTRUCTIONS FOR CENTRAX CENTRIFUGAL FAN READ AND SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS With the use of any electrical appliance it is important to observe all basic precautions to minimize the risk associated with use such as electrical shock fire or injury to persons If this unit is installed in a bathroom or kitchen power must be supplied from a ground fault circuit interruptor GFCI Read these instructions before using your Centrax fan NEVER EXPOSE YOUR CENTRAX FAN TO TEMPERATURES OVER 140 F 60 C INSTALLATION 1 Install mounting brackets to fan Refer to Figure 1 2 Secure mounting brackets to a fixed structure Refer to Figure 2 3 Connect the Centrax to ventilating system using 6 6 screws Supplied when connecting to rigid duct or 2 cable ties Supplied when connecting to flex duct 4 Connect to power source Refer to Figure 3 CAUTION Before carrying out any maintenance or servicing ensure the unit is disconnected from the main supply FOR GENERAL VENTILATION USE ONLY DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS OR DUST Use supply wires suitable for 105 C WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJ URY TO PERSONS OBSERVE THE FOLLOWING a Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer b Before servicing or cleaning unit switch power off
2. Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 8 y1 we x DE i Salf Tapping Machine Hex Mut i a Liang hens Mounting Bn i Washer Washer Washer Bracket oe ee Sm eva TF106 amp eee Lee ave ove ove ove lone 10 1 RTO x Ba i sell Tapping Mia hire hex Mun pile ra a a Flat Mounting DANAN aia Washer Washer Washer Bracket TF110 amp TF112 Qty 3 Giy 8 Qty amp Qty amp Cty 8 Qty 8 Cty 4 Wo Screws For Securing Rigid Duct Connection Included In all units Cable Ties For Securing Flex Duct Connection Included in all units http www suncourt com CentraxPrint html 1 6 2012 10 34 01 AM Centrax Print FIGURE 1 MOUNTING BRACKETS NOTE Rubber washer must be placed between bracket and housing FIGURE 2 MOUNTING _f _ ic al l i Min CE i a CES ij f 1 FAN INTAKE i gt P m FAN EXHAUST L oO ce i __ j oj i i i i TA i oS hue i O r ELECTRICAL CONNECTIONS 1 Remove the screws from the electrical box cover plate 2 Install the appropriate size strain relief or conduit fitting in knock out provided on the side of the electrical box Run the incoming power through the strain relief or conduit and knockout 3 Connect the incoming power according to the wiring diagram Refer to Figure 3 4 Secure the strain relief and reattach the electrical box cover The fan is now ready fo
3. at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel http www suncourt com CentraxPrint html 1 6 2012 10 34 01 AM Centrax Print c Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction d When cutting or drilling into walls or ceilings avoid damaging electrical wiring and other hidden utilities e Ducted fans must always be vented to the outdoors f If this unit is to be installed over a tub or shower it must be marked appropriately for the application and be connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit g NEVER place a switch where it can be reached from a tub or shower h When used in an attic install exhaust side of the fan facing an unoccupied space i This unit has an unguarded impeller Do not use in locations readily accessible to people or animals j Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating
4. epair or misuse of the unit This warranty is given in lieu of all other warranties guarantees and conditions on manufacturer s part and the manufacturer shall have no tortious or other liability in respect to this Centrax centrifugal fan Actual product appearance may differ from illustrations Suncourt reserves the right to modify any or all of its products features designs components and specifications without notice TOOLS NEEDED http www suncourt com CentraxPrint html 1 6 2012 10 34 01 AM Centrax Print SUNCOURT INC 500 W SECOND AVENUE P O BOX 40 DURANT IOWA 52747 0040 1 800 999 FANS 3267 Copyright 1998 2011 Suncourt Inc All Rights Reserved http www suncourt com CentraxPrint html 1 6 2012 10 34 01 AM
5. r use http www suncourt com CentraxPrint html 1 6 2012 10 34 01 AM Centrax Print FIGURE 3 WIRING DIAGRAM Wiring diagram does not apply to units with installed cord PRE WIRED FACTORY CONNECTIONS WHITE NEUTRAL WHITE NEUTRAL ACK LINE a AN a BLACK LINE LACK LINE a i aes i m i peopel GREEN OR N B ER i I s E Ee i j eet ee i 7 GREEN OR GREEN YELLOW GREEN YELLOW A l TE WD SEPRE a a e GROUND GROUND Tie ee CUSTOMER CONNECTIONS 1Z0VAC 80Hz MOTOR 120VAC 60Hz TP MAINTENANCE Inspect the product at least once every 12 months for excessive dust and dirt build up on the impeller more often in dusty environments Clean as necessary The unit must be disconnected from power during inspection and or cleaning FIVE YEAR LIMITED WARRANTY Subject to the following limitations Suncourt Inc manufacturer warrants that the Centrax centrifugal fan will for 5 five years from date of original purchase remain free from appearance of defects in workmanship or materials This warranty is subject to the following limitations a manufacturer s liability is limited to the replacement or repair of the unit as decided by the manufacturer b a defective unit must be returned prepaid with proof of purchase to Suncourt and c this warranty does not apply to defects resulting from the alteration abuse accidental damage unauthorized r