Home
Port-A-Cool PACJS1600 Use and Care Manual
Contents
1. rel rm VAR SPD SWITCH HARNESS 1 4 NPT PLUG P 28 FOR 16 UNIT FRONT FLAP FOR 16 JETSTREAM FLOAT VALVE HOSE FMI8 18 FLOAT HOSE ww a HOSE FTG 05 SWIVEL HOSE FITTING c EA um P P E NE 8 2 i P B LEN Lamm Port A Cool amp Products and Accessories and K l amp Pads Cooling Media are manufactured by MANUFACTURED BY PORT A COOL LLC Port A Cool LLC P O Box 2167 709 Southview Circle Center TX 75935 Phone 936 598 5651 800 695 2942 www port a cool com Part Number OM JS 01
2. To reduce the risk of electric shock fire or injury Do not operate any fan with a damaged cord or plug Discard fan or return to an authorized service facility for examination and or repair Do not run cord under carpeting Do not cover cord with throw rugs runners or similar coverings Arrange cord away from traffic area where it will not be tripped over Read instructions and labels carefully Always unplug the electric cord to your cooler before you work on the cooler Plug into three prong grounded GECI protected electrical receptacle only Do not operate if there is any damage to the plug or cord Do not step on or roll over power cord with heavy or sharp objects Do not operate unit unless all panels are securely in place Remove the plug from the electrical receptacle by pulling on the plug and not the cord Test the GFCI receptacle or breaker monthly to ensure it is functioning properly Do not operate near open containers of flammable liquids or gases Never wash your cooler cabinet with a garden hose water may harm the motor and electrical system If the unit is damaged or it malfunctions do not continue to operate it Refer to the warranty troubleshooting or FAQ section call Port A Cool LLC Technical Support at 888 COOL AIR 1 888 266 5243 or email support port a cool com PAGE 1 PORT A COOL JETSTREAM OWNERS MANUAL SETUP INSTRUCTIONS The Port A Cool Jetstream 1600 model is pre assembled and
3. JETSTREAMD Owners Manual READ AND SAVE THESE INSTRUCTIONS TABLE OF CONTENTS EnttOdUo TOM e it ic lt alai a ln 1 How to Safely Operate your new Jetstream unit 1 Setting up your new Port A Cool Jetstream 1600 2 How to Operate your new Port A Cool Jetstream 1600 3 How to Maintain Your Port A Cool Jetstream 1600 3 Jetstream unit Operation Warning sinea oii ta petri i 4 How to Maintain the K l amp pads media 5 Replacing K l pad media ate d d Duet ate aaa 5 Troubleshooting APROBE COEN MOR ERE APORT tn sad ton II ICR NE 6 Port A Cool Jetstream 1600 Wiring Diagram 7 Product Warranty eco tus ua aaa azot stia edri bi 8 How to Contact Technical 01 9 Replacement Pati casate taiata east pietate ca a 9 11 PORT A COOL JETSTREAM OWNERS MANUAL INTRODUCTION Evaporative cooling works on the principle of heat absorption by mois ture evaporation Simply put heat is removed from the air as water evaporates You feel this principle in action when you step out of a swimming pool or shower and feel immediately cooler as water evapo rates from the surface of your skin Your evaporative cooler works on the same principle Hot outside air is pulled through water saturated pads where the air is cooled by evapo ration and then discharged from the cooler SAFE OPERATION IMPORTANT SAFETY INSTRUCTIONS
4. This warranty gives you specific legal rights and you may have other rights which vary from state to state Since Port A Cool LLC follows a policy of continuous product improvement it reserves the right to change design and specification without prior notice or liability PAGE 8 PORT A COOL JETSTREAM OWNERS MANUAL HOW TO CONTACT TECHNICAL SUPPORT Technical support and service is available directly from your distribu tor or call Port A Cool Technical Support Hotline at 888 266 5243 888 COOL AID for the distributor nearest you You may also contact the Support Hot Line for consultation on parts replacement Please have serial number and model number of unit available REPLACEMENT PARTS A Returned Merchandise Authorization RMA Procedures All Port A Cool units parts or materials being returned to Port A Cool LLC for warranty replacement or repair require an RMA Return Merchandise Authorization number There are two methods for replacing warranty parts 1 The distributor can purchase the part with an RMA number and will only be charged for the cost of the part not for the shipping When the defective part is returned freight paid the distributor s account will be credited for the cost of the part 2 The customer distributor can call Tech Support to get an RMA number to send the defective part back to Port A Cool LLC Once the part is received by Port A Cool LLC a replacement part will be sent at no ch
5. anel Adjustable Louvers Electrical Plug Cord Wrap Hose Connection Locking n T Casters PAGE 4 PORT A COOL JETSTREAM OWNERS MANUAL KUUL PAD MAINTENANCE Periodic draining of the pump will help reduce the build up of calcium deposits on the pad and pad frame Periodic cleaning of the pads will also help increase the life of the pads and the cooling performance of the cooler Do not attempt to clean the pads while they are installed in the pad frames or in the cooler They must be completely removed from the cooler see K l amp Pad Replacement on this page and then can be hosed off and lightly brushed to remove or reduce the calcium build up Pads must be replaced though if the calcium build up starts to completely block air passages through the pad KUUL PAD REPLACEMENT The cooling pads should be changed at least every two years Check and clean them at the beginning of the season The pads may need to be replaced more frequently depending on local conditions and the maintenance schedule followed Replace cooling pads as follows CAUTION DISCONNECT POWER BEFORE PERFORMING THIS OPERATION The flap must be removed to allow access to the cooling pads Start with the center pad which should be tilted out from the top and lifted out of the drain trough The two pads to either side of the center pad may then be removed in the same manner Should you desire to re move the two outside
6. arge Information needed to get an RMA number 1 The UNIT serial number 2 The UNIT model number ex PAC2KCYCOI 3 The part number or description of the part to be replaced Only major component parts need an RMA number i e fans motors pumps and some plumbing parts For replacement of small parts the serial and model numbers are still required but the parts do not need to be returned to Port A Cool LLC PAGE 9 PORT A COOL JETSTREAM OWNERS MANUAL For warranty replacement parts call Port A Cool Technical Support at 1 888 266 5243 FAX 936 598 1431 Shipping Address Mailing Address Port A Cool LLC Port A Cool LLC 721 FM 2468 at Henrietta Road P O Box 2167 Center Texas 75935 Center Texas 75935 PABE 10 PORT A COOL JETSTREAM OWNERS MANUAL PACJS1600 ORG SN amp SUBSEQUENT ITEM DESCRIPTION CASTER BASE ASSEMBLY FOR JS VT JS VT 16 BLADE SPRAY BAR BONNET FOR 16 PAC VAR SPD ELECTRICAL BOX 4 JS VT NON LOCKING CASTER 4 JS VT LOCKING CASTER Dr poa jam os 5 16 X 1 TRUSS HEAD SCREW B pe wewnewemenr 7 E pw 7 peux po pec 7 pense 77 SWITCHPLVARSPD JSACCOI 2 THREADED FILLER CAP RING UBE 0I 7 2 THREADED FILLER CAP 6 TUBE 03 Dr ewes pause y pues rosa ore PAGE 11 PORT A COOL JETSTREAM OWNERS MANUAL el rel EGES i a E E N E 1 2 WIRE SPRING CLAMP KNOB 24 VAR SPD CONTROL CONTROL VALVE MOUNTING BRACKET
7. ated under normal conditions within the continental United States I One Year Coverage applies to all components and accessories furnished by Port A Cool LLC At our option we will exchange or repair any part which fails due to non conformance of material or workmanship during the first year from the date of initial purchase II What this warranty does not cover a This warranty does not cover any failure or damage resulting from unauthorized modification or service or from the use of products or replacement parts other than those from Port A Cool LLC including but not limited to motors and pumps b This warranty does not cover any damage or malfunction unless caused by a non conformance in material or workmanship Damage or malfunction which is not covered by this warranty includes but is not limited to water damage to the motor abuse misuse alteration improper installation maintenance operation and transportation damage c Mineral accumulations dirt and dust on the pad are not defects and are excluded from this warranty Refer to the owners manual supplied with your cooler for maintenance instructions to help minimize these conditions d This warranty does not cover the cost of a service call at the site of installation to diagnose cause of trouble the cost of labor to install the part or mileage allowance to or from the site Port A Cool LLC does not pay freight or postage on any exchange e This warranty does not cove
8. n the sump tank over time This debris and any remaining water may be vacuumed out using a wet dry shop vacuum and wiped clean with a cloth Also inspect and clean the Inlet Strainer located on the pump Replace pads in correct airflow direction referring to label on the pads Storage Storage of the Port A Cool Jetstream 1600 unit is very simple 1 Drain all water from the sump tank and clean as above ensuring that the pads and sump are completely dry CAUTION DISCONNECT POWER BEFORE REMOVING COOLING PADS FROM THE PORT A COOL unit PAGE 3 PORT A COOL JETSTREAM OWNERS MANUAL 2 Roll up the electrical power cord and secure it to ensure that it will not be rolled over tripped over or caught in equipment NOTICE POWER CORD MAY BE REPLACED ONLY BY THE MANUFACTURER OR QUALIFIED AGENT 3 Cover the Port A Cool Jetstream 1600 unit completely to prevent dust build up and store in a dry area This also helps prevent damage to the pads Optional dust covers are available from your distributor JETSTREAM UNIT OPERATION WARNING 1 not intended for use by children 2 not intended for use by persons with reduced physical sensory or mental capabilities 3 not intended for use by persons with lack of experience and knowledge unless they have been given instruction and are supervised during operation 4 children should be supervised to ensure that they do not play with the appliance Water Adjustment Control Valve P
9. on the opposite side of the space from the cooler This allows the cooled air to be moved through the space and exhausted back outdoors which is critical to proper operation of the cooler PAGE 2 PORT A COOL JETSTREAM OWNERS MANUAL OPERATING INSTRUCTIONS Make sure the two locking casters have been locked to prevent the cooler from moving before turning on the fan Turn on the water sup ply to the cooler The hose connection to the float valve provides an automatic method of refilling the water supply as water is evaporated For best results turn the pump on a few minutes before turning on the blower fan This allows the cooling pads to pre wet for best efficiency Whenever possible operate the blower fan at low speed for maximum cooling When cooling is not required you can operate the unit as a fan only by turning on the blower fan and leaving the pump turned off WARNING To Reduce The Risk Of Fire Or Electric Shock Do Not Use This Fan With Any Solid State Speed Control Device Jetstream UNIT MAINTENANCE amp STORAGE At the end of the week or at a scheduled time the unit should be shut down and the sump tank should be drained To drain remove small drain plug in the rear of the unit Replace securely when finished Once the sump is drained and the power disconnected the pads may be removed to allow inspection of the sump tank Assuming that the Port A Cool Jetstream 1600 unit is in a dusty environment dust will collect i
10. pads 2 Outdoor humidity level is too high or it is raining REMEDY 1 Check power A Replace fuse B Reset breaker C Reset GECI D Plug in cord s or replace if dumaged f condition persists call electrician 2 Replace motor 1 Open windows or doors 2 Check water distribution system A Clean or replace pads B Check water level C Make sure cooler is level dean spray bar D Clean or replace pump E Check for leaks and correct 1 Adjust float to proper level 2 Replace float valve 3 Tighten fitting and or cap 1 Drain flush and clean sump 2 Replace pads 3 Turn on pump before starting fan 1 Check and tighten where needed 2 Inspect and adjust or replace 1 Make sure pads are properly positioned in the pad frames and that the unit is level 2 Use cooler as a fan only turn pump off or discontinue use of cooler until outdoor humidity level drops PORT A COOL JETSTREAM OWNERS MANUAL Connector M 03 Black Black White Red Green Connector f 05 While x Connector M 05 j Black AN A Green VAR Spd Motor Connecior M 04 Connector F 04 Port A Cool LLC amp Pump PORT A COOL JETSTREAM OWNERS MANUAL PABE 7 Jetstream LIMITED WARRANTY I YEAR LIMITED WARRANTY Port A Cool LLC Center Texas extends this limited warranty to the original purchaser of a Port A Cool Jetstream Evaporative Cooler oper
11. pads they must first be pulled sideways toward the center of the Port A Cool Jetstream 1600 unit until they clear the side retainer They may then be removed in the same manner as the other pads PAGE 5 PORT A COOL JETSTREAM OWNERS MANUAL TROUBLESHOOTING The following troubleshooting guide is intended to address the most common symptoms which may occur If you are unable to resolve the issue please call Technical Support Turn off all power to the cooler before attempting to troubleshoot any of the following symptoms SYMPTOM Unit fails to start or deliver air Unit starts but air delivery inadequate Water draining from cooler Musty or unpleasant odor Knocking shaking or rattling sounds Water droplets in the discharge air stream PAGE 6 POSSIBLE CAUSES 1 No electrical power to unit A Fuse blown B Circuit breaker tripped C GECI tripped D Cord s unplugged or damaged 2 Motor overheated and or frozen 1 Insufficient air exhaust 2 Insufficient water pad not wet A Cooling pads plugged B Dry streaks on pads C Large dry spots on pads D Pump not working E Loose water connections 1 Float arm improperly adjusted 2 Seat in float valve leaking 3 Drain bushing cap not tight 1 Stale or stagnant water in sump 2 Pads mildewed or clogged 3 Pads not completely wet before cooler is turned on 1 Loose parts 2 Blower wheel loose or rubbing 1 Too much water delivered to the cooling
12. r evaporative coolers installed and operated outside the continental United States III Do not use cooler cleaners cooler treatments or other additives in this evaporative cooler The use of any of these products will void your warranty and may impair the life of your evaporative cooler IV To obtain service under this warranty contact the dealer where you purchased your evaporative cooler As a final step if you cannot locate your dealer contact Technical Support Port A Cool LLC P O Box 2167 Center Texas 75935 Include your name address and ZIP code the model number and serial number of your evaporative cooler date of installation and a description of your problem or call 1 888 COOLAID or visit www port a cool com This warranty is the only warranty extended by Port A Cool LLC to suppliers and or purchasers of this evaporative cooler Port A Cool LLC disclaims all other warranties express or implied that arise by the operation of the law except that implied warranties of merchantability or fitness for a particular purpose are limited to the dura tion of the warranty period Port A Cool LLC shall not be liable for any incidental or consequential damage which may have resulted from any alleged breach or warranty Some states do not allow limitations on how long an implied war ranty lasts or the exclusion or limitation of incidental or consequential damages so the limitations or exclusions stated above may not apply to you
13. ready to operate Sim ply remove the packaging and then care fully roll the unit from the box Connecting to water Move the cooler to an area where it can be filled with water and drained The cooler should be located on level ground Connect to a water supply using a commercial grade garden hose supplied by customer Simply attach the hose to the adapter located on the left side of the unit see figure 1 Verify water tight connections by visually examining the hose connection and the drain plug The Port A Cool Jetstrream 1600 also features the filler cap option see Figure 1 above that holds 40 gallons of water for increased portability CAUTION Water inlet pressure should be limited to a maximum 50 PSI Connecting to a power supply When making electrical connections insure that local and national codes are adhered to Use only with GFCI Protected Receptacles Please refer to the Barcode Product Label on the side of the unit for specific electrical requirements LOCATION OF COOLER Always make sure the unit is operated on a level surface When using the cooler indoors the best location is near a partially opened window or door where hot outdoor air can be drawn into the unit The Port A Cool Jetstream 1600 is portable but use caution when rolling the unit to avoid splashing and spilling of water Cool air can best be directed through the space by using a partly opened window or door ideally one that is situated
Download Pdf Manuals