Home
Emberglow CSO24NG Installation Guide
Contents
1. 7 TO 1 2 GAS LINE LEFT SIDE al KNOCKOUT j 13 PLUG FLARED END RIGHT SIDE KNOCKOUT TO 14 PL UG BURNER BAR 7 REF DUAL BURNER Z21 84 PART NUMBER QTY PART NUMBER QTY PART NUMBER QTY 18 SET 24 SET 30 SET 1 6 LOGS 1 1 1 7 GRATE WIP 200 90556 1 WIP 200 90566 1 WIP 200 90680 1 8 BURNER PAN WIP 200 90502 1 WIP 200 90504 1 WIP 200 90506 1 9 DUAL BUNER BAR WIP 190 90521 1 WIP 190 90523 1 WIP 190 90525 1 10 3 4 BURNER SUPPORT SPACER RMH 120 00420 1 RMH 120 00420 1 RMH 120 00420 1 11 3 8 BRASS ORIFICE ELBOW WIP 120 00350 1 WIP 120 00350 1 WIP 120 00350 1 12 3 8 LOCKNUT RMH 120 00963 1 RMH 120 00963 1 RMH 120 00963 1 13 VALVE X X X X X X 14 DAMPER STOP CLAMP RMH 120 00100 1 RMH 120 00100 1 RMH 120 00100 1 15 3 8 FLARED TUBING WIP 120 90426 1 WIP 120 90426 1 WIP 120 90426 1 16 GRANULES WIP 130 00010 1 WIP 130 00010 1 WIP 130 00010 2 17 GLOWING EMBERS WIP 130 00300 1 WIP 130 00300 1 WIP 130 00300 2 18 BACK LOG STANDOFFS WIP 190 90560 2 WIP 190 90560 2 WIP 190 90560 2 19 TAPE SEALANT RMH 120 00180 1 RMH 120 00180 1 RMH 120 00180 1 20 INSTRUCTION MANUAL RMH 130 00588 1 RMH 130 00588 1 RMH 130 00588 1 21 WASHER RCODZ00145A 1 RCOPZ00007A 1 RCOPZ00007A 1 WARNING Improper use or installation may cause Carbon Monoxide Poisoning Carbon Monoxide is an colorless and odorless gas and is a by product of combustion Caution must be taken to insure thefireplace is properly vented when logs are in use To avoid havi
2. open position anytime the unit is in operation C Prior to connecting the gas log set make sure that the gas supply to the fireplace is completely shut off MASONRY FIREPLACE FIREPLACE Figure 2 Damper stop clamp D Prefabricated fireplace Refer to the manufactures fireplace instruction manual for specific information regarding the running of a gas line into that particular model A typical installation involves the insertion of a 1 2 inch gas pipe through the gas line tube provided by the man ufacturer from outside the fireplace The Knockout on the inside of the fireplace is removed as the gas pipe is punched through the fireplace See Figure 3 E Masonry fireplace A 1 2 inch gas supply line must be provided to the firebox Most install ations require drilling an access hole through the masonry wall The supply line should be secured and sealed by mortar within the access hole The supply line should also have a _ shutoff valve either in the wall or inside the fireplace see Figure 4 GAS SUPPLY TT va GAS ON OFF BURNER PAN VALVE INSIDE GAS SUPPLY FIREBOX LINE 4 a VALVE REPACK MOUNTED IN WALL INSULATION REPACK INSULATION GAS SUPPLY LINE 4 INSIDE Pi FIREPLAGE nd Sul PLY Figure 3 Gas line installation Prefabricated Fireplace Figure 4 Gas line installation Masonry Fireplace GAS LOG INSTALLATION See Figure 7 Parts List as a guide to reference part numbers BURNER PAN INSTA
3. side Place Cross Log 6 from the center 11 to the right side LOG PLACEMENT MODEL MO24NG Continued Place Cross Log 7 atop the center Left 4 to the center right 5 logs LOG PLACE MENT MODEL SH18NG gt Soup 4 de mn Log Identification Back Log Stand Offs in place Place main front log 1 onto Place shorter back log 2 onto front area of the grate raised area of the grate Place Cross Log 5 at the center Place Cross Log 6 from the center to the right side 13 LOG PLACEMENT eee 1 Log Identification Back Log Stand Offs in place Place main front log 1 Place shorter back log 2 onto front area of the grate onto raised area of the grate Place Cross Log 5 at the center right Place Cross Log 6 at the right side 14 LOG PLACEMENT MODEL SH24NG Continued Place cross log 7 atop cross log 6 and to front center as shown 15 MAINTENANCE Very little maintenance is required The carbon deposit resulting from combustion is natural and adds to the realistic appearance of the set If carbon becomes excessive it can be lightly brushed or vacuumed away TROUBLE SHOOTING Problem Cause Corrective Action 1 No Ignition Valve not fully in on position turn valve to on position gas line obstruction inspect supply lines tube for kinks or obstructions 2 Inadequate flame Valve partially closed open valve fully gas line partial obstruction inspect burner
4. tube for kinks or obstructions log arrangement incorrect rearrange logs to specified pattern WES AES Mel il Warranty shall apply t All logs are guaranteed for three years against manufacturer s defects The burner assembly system is guaranteed for a period of 3 years from the date of purchase and will be replaced for freight costs only Pilot valves and thermocouples are guaranteed for a period of one 1 year under the original manufacturers warranty General Warranty This warranty does not apply in the case of improper installation neglect accident misuse or as a result of modifications of the original product All costs for removal and re installation are the expressed responsibility of the purchaser For repair replacement or service to defective part s please contact our Customer Service Hotline number below Thereafter with valid warranty registration and proof of purchase call the Customer Service Hotline for authorization to ship defective part prepaid and insured in original carton to Sure Heat Manufacturing E 1861 West Oak Partway Marietta GA 30062 Goods returned improperly packaged are the sole responsibility of f purchaser It is agreed that any repair or replacement is the exclusive remedy from Sure Heat Manufacturing In no case shall amp E Sure Heat be liable for any consequential damage or breach of this or any other warranty expressed or implied IE whatsoever This limitation as to conseq
5. INSTALLATION amp OPERATION MANUAL DECORATIVE VENTED GAS FIREPLACE LOG TIERED DUAL BURNER LOG SET Models BRO18NG BRO24NG CSO24NG CSO30NG MO18DBNG MO24DBNG SH18NG SH24NG Burner set for use with all styles and sizes of SureHeat Dual Burner Natural Gas Log Sets WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS e Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions e If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference SHM INTERNATIONAL 2012 aie Complies with ANSI Z21 84 i Laboratores Inc DUAL BURNER PART LIST Figure 1 GRANULES HEAVY WEIGHT BAG GLOWING EMBERS LIGHT WEIGHT BAG 1 6 NUMBER OF LOGS ARE DETERMINED BY THE SIZE AND MODEL CHOSEN SETS RANGE FROM 4 TO 9 LOGS 18
6. LACEMENT MODEL BRO24 Log Identification Back Log Stand Offs in place Place log 1 onto back right Place Y shaped log 2 onto left area of the grate of the grate ahead of raised area Place log 3 onto back left area of Place log 4 at the front right of the the grate perpendicular to log 1 grate with the split area to the flame Place log 5 on to log 2 and brace it Place log 6 atop logs 5 and 4 on the grate finger left of center as shown LOG PLACEMENT MODEL BRO24 Continued Place the two small logs 7 and 8 in front of the grate as shown LOG PLACEMENT MODEL CSO24 CSO30 Log Identification Back Log Stand Offs in place Place Right front log 1 onto Place left front log 2 onto front area of the grate front area of the grate Place back log 3 onto Place Cross Log 4 at the center left raised area of the grate Place Y shaped Cross Log 5 at right Place Cross Log 6 from front left to lay on log 5 as shown LOG PLACEMENT MODEL CSO24 CSO30 Continued Place Cross Log 8 at the top center across logs 5 and 7 Place log 8 in front of the set on the pireplace floor Make sure it is in front of the burner pan 10 LOG PLACE MENT MODEL MO24NG Back Log Stand Offs in place Log Identification Place Main Front Log 1 onto Place shorter back log 2 onto front area of the grate Back Log Stand Offs Place Cross Log 5 at the right
7. LLATION NOTE Use pipe compound on all male threads to seal joints A Determine if the fireplace has a right or left hand gas line feed The circular Dimpled hole covering must be knocked out on the appropriate side right or left of the burner pan NOTE Brace panon workbench when removing burner knock out Strike knock out plug with a punch or drift p Locate 3 8 locknut Part 12 and washer Part 21 and KNOCKOUT attach them to the 3 8 brass ori fice elbow Part 11 Do KNOCK OUT PLUGS not fasten the locknut on the flared end MORRERON BURNER PAN C Slide the 3 4 burner support spacer Part 10 over the Figure 5 Burner bar placement Dual Burner bar Part 9 and move spacer to opposite side of the gas inlet connection See Figure 5 D Secure the intake end of the Dual burner bar Part 9 to the burner pan Part 8 through the knock out hole selected right or left hand with the 3 8 brass orifice elbow Part 11 3 8 locknut Part 12 and washer Part 21 previously assembled in Step B See Figure 6 E Tighten elbow until firmly attached to the Dual burner bar Then firmly tighten the attached lock nut on the elbow to Figure 6 Burner bar connection seal the burner bar to the wall of the burner pan CONNECTING GAS SUPPLY TO BURNER ASSEMBLY Natural Gas applications installed without a Safety Pilot Kit LP NG Safety Pilot Kit available at your local store If a Safety Pilot Kit
8. he burner pan filling the entire pan See Figure 7A B Spread glowing embers Part 17 evenly over the top of the granules covering the entire surface area concentrating on the front and sides of the burner pan for the most realistic burning effect C Place log grate Part 7 over the burner pan aligning as shown See Figure 7B D Attach back log Standoff Part 18 to the back part of the grate Figure 7 A amp B Granule and See Figure 7B Grate Placement NOTE A hammer may be used to tap the back log stand off in place It may be necessary to squeeze the back log stand off with pliers after attaching to the grate Figure 8 Lighting the log set LIGHTING YOUR GAS LOG SET Manual Valve only A Open chimney flue damper to the full open position B Be sure gas supply is shut off C Lay match on top of embers and granules near gas burner input Do not hold match in hand See Figure 8 D With match burning slowly turn on gas LOG PLACE MENT MODEL BRO18NG Back Log Stand Offs in place Place log 1 onto back left area of Place log 3 at the front right of the the grate perpendicular to log 2 grate with the burned area to the flame Place Y shaped log 4 onto left Place log 5 atop log 4 brace on of the grate ahead of raised area left center grate finger Place log 6 atop logs 1 and 3 Place the two small logs 7 and 8 in front of the grate as shown LOG P
9. is to be used please refer to seperate instructions included with the kit A Place burner pan assembly in the center of the fireplace B Attach 3 8 Flare X 1 2 NPT gas valve Part 13 to the 1 2 inch gas eae stub already in fireplace Be certain connections are tight and use pipe compound on all male NPT pipe threads to seal joints C Attach 3 8 flared tubing Part 15 to burner pan assembly Attach opposite end to gas apo line by carefully b nding the flared tubing as needed to make the connection Avoid kinking the tubing while bending If tubing must be cut use a tubing cutter Flare the cut end of tube with a flaring tool NOTEAgood method of bending the tube is to fill it with sand bending the tube as needed to make the connection This method will eliminate kinking in the line Once the tube is in the desired configuration be sure to empty the tube completely of any sand before tube is connected to the gas supply line and burner assembly D Be certain all connections are tight Only use pipe compound on all male NPT pipe threads Test all connections with a soapy water solution and with the gas supply turned on If bubbles appear on any connection tighten and re test Once it is determined there are no leaks whatsoever turn off gas supply and move to next assembly step GRANULE EMBER AND GRATE PLACEMENT A Spread granules Part 16 over the installed burner pan Granules should be sloped to the same angle as t
10. ng potentially dangerous fumes enter the living area be sure the chimney is drawing pro perly and has sufficient draft WARNING Do not burn wood solid fuels or other material in any fireplace fitted with a gas log set Do not store gasoline ammable vapors and liquids in the vicinity of this or any other appliance Do not place clothing or other flammable material on or near the appliance Children and adults should be alearted to the hazards of high surface temperature and should be kept clear to avoid burns or clothing ignition Young children should be carefully supervised when they are in the same room as the appliance Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water A fireplace screen must be in place when appliance is operating Unless other provisions are made for combustion air the fireplace screen must have provisions for combustion air e Installation of this Energy Efficient Gas Log Set and provisions for combustion and ventilation air must conform with the National Fuel Gas Code ANSI Z21 84 and appliance local codes e This gas log set is only to be installed and burned in a fully vented fireplace with a fully functional damper and chimney that is free of any obstructions The fireplace must be constructed of non combustible materials and approved
11. to burn wood To operate this gas log set the fireplace damper must be fully opened and locked e The smallest or minimum dimension of the chimney flue must be 8 inches in diameter Do not use an Energy efficient Gas Log Set if it is smaller than 8 inches Do not use an Energy Efficient Gas Log Set if fumes from the burner emerge into the room when the damper is fully open This indicates that there is not adequate draft for this log set and it must not be used until the fireplace draft is corrected This appliance must be installed with a Damper Stop Clamp Part 14 When operating this gas log set the flue damper must be fully open The nominal inlet gas pressure for this appliance is 7 water column for natural gas This appliance must also be disconnected from th e gas supply system by closing its individual manual shutoff valve during any pressure testing at pressure equal to or less than 1 2 PSIG FIREPLACE PREPERATION A Professionally clean chimney and fireplace floor of any PART NO 14 combustible material to limit the smell from the system B Open fireplace damper fully and install Damper Stop Clamp with 1 4x2 set screw Part 14 This clamp is Designed to allow any pilot combustion by products to vent See Fig 2 Should the Damper Stop Clamp sup plied not fit a permenant damper stop clamp must be installed that will keep the damper open at a distance of not less than 1 1 2 The damper must be in the fully
12. uential damages shall not apply in states where prohibited Purchased From 0 Date Size 18 Name a ie a Please photocopy and return to SHM International within 14 days of purchase If you have other questions please contact the Customer Service Hotline 800 229 5647 OMVVL2012A Rev 1 11 2012