1. Installer Installation Date Place of Purchase Model Number 5084461 New 3 12 WWW AIRKINGLIMITED COM 4of8 INSTRUCTIONS IMPORTANTES MODE D EMPLOI Mod le AK80H Ventilation Products Ventilateur d Evacuation LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D ASSEMBLER INSTALLER OPERER OU DE R PARER LE PRODUIT DECRIT PROT GEZ VOUS M ME ET LES AUTRES EN OBSERVANT TOUTE L INFORMATION DE S CURIT FAILLIR A SE CONFORMER AUX INSTRUCTIONS PEUT R SULTER EN BLESSURE PERSONNELLE GRAVE ET OU EN DOMMAGE LA PROPRI T CONSERVER CES INSTRUCTIONS POUR R F RENCES FUTURES INSTRUCTIONS G N RALES DE S CURIT Lors de l utilisation d appareils lectriques des pr cautions de base doivent toujours tre suivies pour r duire les risques d incendie de choc lectrique et de blessures corporelles incluant ce qui suit AVERTISSEMENT POUR R DUIRE LES RISQUES D INCENDIE DE CHOC ELECTRIQUE OU DE BLESSURES PERSONNELLES OBSERVER CE QUI SUIT a Utiliser cette unit seulement de la mani re pour laquelle le fabricant l a con u Si vous aviez des questions veuillez contacter le fabricant b Avant d effectuer un service ou de nettoyer l unit couper l alimentation lectrique dans le panneau de distribution et verrouiller le dispositif de d connexion afin d viter que l alimentation ne revienne accidentellement Lorsque le dispositif ne p
2. Model AK80H IMPORTANT INSTRUCTIONS OPERATING MANUAL Ventilation Products READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE INSTALL OPERATE OR MAINTAIN THE PRODUCT DESCRIBED PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE RETAIN INSTRUCTIONS FOR FUTURE REFERENCE GENERAL SAFETY INFORMATION When using electrical appliances basic precautions should always be followed to reduce the risk of fire electric shock and injury to person including the following TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK AND INJURY TO PERSON OBSERVE THE FOLLOWING a b Use this unit only in the manner intended by the manufacturer lf you have questions contact the manufacturer Before servicing or cleaning the unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK AND INJURY TO PERSON OBSERVE THE FOLLOWING a 5084461 New 3 12 Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire related construction Sufficient air is needed for proper co
3. 1 Fan does not operate when the switch is on 2 Fan is operating but air moves slower than normal Obstruction in the exhaust ducting Suggested Remedy A fuse may be blown or a circuit tripped Replace fuse or reset circuit breaker Connector plug from motor is not plugged in Turn off power to unit Remove Grill and plug motor into receptacle in housing Restore power to unit Wiring is not connected properly Turn off power to unit Check that all wires are connected Motor has stopped operating Replace motor Check for any obstructions in the ducting The most common are bird nests in the roof cap or wall cap where the fan exhausts to the outside 3 Fan is operating louder than normal Motor is loose 5084461 New 3 12 Fan blade is hitting housing of unit Turn off power to unit Remove grill and check that all screws are fully tightened Restore power to unit Call your dealer for service WWW AIRKINGLIMITED COM 3 of 8 LIMITED WARRANTY WHAT THIS WARRANTY COVERS This product is warranted against defects in workmanship and or materials HOW LONG THIS WARRANTY LASTS This warranty extends only to the original purchaser of the product and lasts for five 5 years from the date of original purchase or until the original purchaser of the product sells or transfers the product whichever first occurs WHAT AIR KING WILL DO During the warranty period Air King will at its sole option r
4. vous r f rer la Section 6 Compl tion de l installation 2 Nettoyage de l assemblage du ventilateur Nettoyer toutes les parties l aide d un chiffon sec ou passer d licatement l aspirateur sur le ventilateur NE JAMAIS IMMERGER LES PARTIES ELECTRIQUES DANS L EAU Remplacer le fusible ou r initialiser le disjoncteur Couper l alimentation l unit Retirer la grille et brancher le moteur dans le r ceptacle dans le cabinet Remettre l alimentation sur l unit Couper l alimentation de l unit V rifier que tous les fils sont raccord s Remplacez la moteur 2 Le ventilateur fonctionne mais l air circule plus lentement que la normale 2 Obstruction dans les conduits d vacuation V rifier pour toute obstruction dans les conduits Les plus courantes sont des nids d oiseau dans le chapeau de toit ou mural l o le ventilateur s vacue vers l ext rieur 3a Le moteur est l che 3 Le ventilateur fonctionne de mani re plus bruyante que la normale 5084461 New 3 12 3b L h lice du ventilateur frotte contre le cabinet de l unit Couper l alimentation l unit Retirer la grille et v rifier que toutes les vis sont compl tement serr es Remettre l alimentation sur l unit Appeler votre marchand pour un service WWW AIRKINGLIMITED COM 7 0f8 GARANTIE LIMIT E QUE COUVRE CETTE GARANTIE Ce produit est garanti contre tout vice de fabrication ou de mati re COMBIEN DE T
5. OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION SECTION 1 Preparing the Exhaust Fan 1 Unpack fan from the carton and confirm that all pieces are present In addition to the exhaust fan you should have 1 Grill 1 Damper Assembly attached 4 Mounting Rails 1 Instruction Safety Sheet 2 Choose the location for your fan To ensure the best air and sound performance it is recommended that the length of ducting and the number of elbows be kept to a minimum and that insulated hard ducting be used Larger duct sizes will reduce noise and airflow restrictions This fan will require at least 8 of clearance in the ceiling or wall and will mount through drywall up to 3 4 thick The fan mounts between 16 or 24 on center joists using the 4 S provided mounting rails 3 Select the most convenient electrical knockout and remove using a straight blade screw driver Figure 1 SECTION 2 New Construction Figure 1 1 Install the side rails on the housing and position the housing next to the joist Line up housing so that it will be flush with the finished ceiling Secure the ends of the rails with screws or nails not included to the joists and slide the housing into the final position Figure 2 Mounting Rails Figure 2 SECTION 3 Existing Construction 1 Set housing in position between the joist and trace an outline onto the ceiling material Figure 3 Set housing aside and cut opening
6. PAS DISPONIBLES POUR DES RAISONS DE S RET BEAUCOUP DE COMPOSANTS LECTRONIQUES ET LA PLUPART DES COMPOSANTS DES CHAUFFAGES NE SONT PAS LA DISPOSITION DES CONSOMMATEURS POUR L INSTALLATION OU LE REMPLACEMENT de pi ce Description de remplacement Cabinet du ventilateur 5S1202001 Traverses de Montage 581299002 Collet 581299003 Clapet 581299004 Assembl e de la Soufflante 582202001 Roue de la Soufflante 582202003 Compartiment de Cablage 581202004 Vis 6 par 3 8 po 581999010 Vis 8 par 5 8 po 581999011 Grille 581202005 Ressorts de la grille 581202006 Vis 10 32 par 3 8 po de mise a la terre 581999002 Fil de mise a la terre de calibre 14 581999003 Vis 6 par 3 8 po 581999010 Couvercle de Cable Externe 581202007 Bouton 581299802 Harnais du Capuchon du Moteur 589202502 im ms mi hea i a a a a a i aa a a a Installateur Date d installation Endroit de l achat Num ro de mod le 5084461 New 3 12 WWW AIRKINGLIMITED COM 8of8
7. to see the humidity sensor set point In cases where the ambient humidity level of the room rises higher than the preset level the fan will turn on even if the room is not occupied This helps prevent conditions that lead to mold growth CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT 1 To set the desired humidity level of the room remove the grill and locate the dehumidistat dial located on the wire compartment cover 2 Set the dial to the relative humidity you want the fan to maintain usually between 50 amp 80 Moist climates will require higher settings than dry climates When the humidity level of the room is below this setting the fan will remain off When the humidity level rises about this setting the fan will turn on and run until the humidity level falls below this setting 3 Reinstall the grill and restore power SECTION 8 Use and Care CAUTIONS make SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT 1 Cleaning the Grill Remove grill and use a mild detergent such as dishwashing liquid and dry with a soft cloth NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS Completely dry grill before reinstalling Refer to instructions in Section 5 Finishing the Installation to reinstall grill 2 Cleaning the Fan Assembly Wipe all parts with a dry cloth or gently vacuum the fan NEVER IMMERSE ELECTRICAL PARTS IN WATER Troubleshooting Guide Trouble Probable Cause
8. un endroit fiable Figure 5 Couvercle du Compartiment de C blage b Compartiment de C blage Int rieur Enlever le vis retenant en place l ensemble venturi du ventilateur et soulever pour sortir l assemblage hors du ch ssis Figure 6 Enlever la vis du couvercle du compartiment c blage et mettre ce couvercle dans un endroit fiable Figure 7 Venturi Figure 6 Bouton de point de consigne d humidit Couvercle du Compartiment de C blage WWW AIRKINGLIMITED COM 6 of 8 REMARQUE Si le raccord du moteur de ventilateur est raccord au r ceptacle du ch ssis le d brancher afin que l ensemble venturi du ventilateur soit compl tement enlev 2 Pour un bon fonctionnement le ventilateur de d tection d humidit exigera un interrupteur 3 voies non inclus Faites passer le c blage entre le ventilateur et l emplacement du commutateur Assurez vous de laisser suffisamment de c blage dans chaque bo te pour faire les connexions la bo te de commutation connectez le fil noir de la maison la borne commune du commutateur Connectez le fil noir du ventilateur l une des bornes commut es sur le commutateur Cette position activera le mode automatique et le ventilateur s activera apr s une l vation d humidit Connectez le fil rouge du ventilateur l autre borne commut e sur le commutateur Cette position activera le mode manuel et activera le vent
9. EMPS CETTE GARANTIE DURE Cette garantie se rapporte seulement l acheteur original du produit et dure pendant cinq 5 ann es de la date de l achat original ou jusqu ce que l acheteur original du produit vend ou transf re le produit celui qui se produit en premier QUE FERA AIR KING Au cours de la p riode de garantie Air King son choix r parera ou remplacera n importe quelle partie ou pi ces qui s av rent d fectueuses ou remplacera le produit entier par le m me mod le ou un mod le comparable CE QUE CETTE GARANTIE NE COUVRE PAS Cette garantie ne s applique pas si le produit tait endommag ou arr te de fonctionner en raison d un accident d une mauvaise manipulation ou op ration de dommages d exp dition d abus de mauvaise utilisation de r paration faite ou tent es non autoris es Cette garantie ne couvre pas les co ts d exp dition pour le retour des produits Air King pour la r paration ou le remplacement Air King payera les frais d exp dition de retour de Air King apr s les r parations ou le remplacement de garantie TOUTES LES GARANTIES EXPRESSES OU TACITES COMPRENANT SANS LIMITATION TOUTE GARANTIE TACITE DE VALEUR MARCHANDE DURENT UN AN DE LA DATE DE L ACHAT ORIGINAL OU JUSQU CE QUE L ACHETEUR ORIGINAL DU PRODUIT VEND OU TRANSFERE LE PRODUIT CELUI QUI SE PRODUIT EN PREMIER ET DANS AUCUN CAS AIR KING N ASSUME AUCUNE RESPONSABILIT EXPRESSE OU TACITE POUR I DES DOMMAGES ACCIDENTELS OU INDIREC
10. TS DE N IMPORTE QUELLE CAUSE OU II LE REPLACEMENT OU LA R PARATION DE TOUS FUSIBLES DISJONCTEURS OU RECEPTACLES DE MAISON MALGR N IMPORTE QUOI LEFFET CONTRAIRE DANS AUCUN CAS LA RESPONSABILITE D AIR KING SOUS UNE GARANTIE EXPRESSE OU TACITE NE DEPASSERA LE PRIX D ACHAT DU PRODUIT ET UNE TELLE RESPONSABILITE SE TERMINERA AVEC L EXPIRATION DE LA P RIODE DE GARANTIE Certains tats et provinces ne permettent pas les limitations de la p riode de garantie ou l exclusion ou la restriction des dommages accidentels ou indirects et par cons quent les pr sentes restrictions ne peuvent pas s appliquer La pr sente garantie vous donne des droits l gaux sp cifiques et peut tre certains autres droits qui peuvent varier selon la province La preuve d achat est exig e avant qu une r clamation de garantie ne soit accept e SERVICE LA CLIENT LE Sans frais 800 465 7300 Notre quipe de service la client le est disponible pour vous aider avec des questions sur le produit les adresses des centres de service et les pi ces de rechange Vous pouvez la rejoindre du lundi au vendredi de 8h 00 16h 00 HNE Veuillez avoir le num ro du mod le disponible ainsi que le genre et le style qui se trouvent sur l tiquette l int rieur de votre produit Veuillez ne pas renvoyer le produit l endroit de l achat www airkinglimited com IL SE PEUT QUE LES PIECES POUR LES PRODUITS DISCONTINUES OBSOLETES ET AUTRES PRODUITS NE SOIENT
11. being careful not to cut or damage any electrical or other hidden utilities Install the side rails on the housing and position the housing in the previously cut hole so that it is flush with the finished ceiling Secure the ends of the rails to the joists Figure 2 Joist Figure 3 SECTION 4 Ducting CAUTIONS ALL DUCTING must COMPLY WITH LOCAL AND NATIONAL BUILDING CODES 5084461 New 3 12 1 Connect the ducting to the fan s duct collar Figure 4 Secure in place using tape or screw Clamp Always duct the fan to the outside through a wall or roof cap Duct Collar SECTION 5 Wiring CAUTIONS make SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION CAUTIONS att ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE WITH LOCAL CODES ORDINANCES OR NATIONAL ELECTRICAL CODE IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN NOTE This unit includes a side access panel for wiring that does not require the removal of the fan s blower assembly If you choose to wire the unit from the inside you will need to remove the blower assembly and internal wiring compartment Both methods are equally effective ja External Wire Compartment Remove the wire compartment cover screw and place cover in a secure place Figure 5 Wire Compartment Cover 1b Internal Wire Compartment Remove the screw holding the venturi in place Lif
12. epair or replace any part or parts that prove to be defective or replace the whole product with the same or comparable model WHAT THIS WARRANTY DOES NOT COVER This warranty does not apply if the product was damaged or failed because of accident improper handling or operation shipping damage abuse misuse unauthorized repairs made or attempted This warranty does not cover shipping costs for the return of products to Air King for repair or replacement Air King will pay return shipping charges from Air King following warranty repairs or replacement ANY AND ALL WARRANTIES EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY LAST ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS THE PRODUCT WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACMENT OR REPAIR OF ANY HOUSE FUSES CIRCUIT BREAKERS OR RECEPTACLES NOTWITHSTANDING ANYTHING TO THE CONTRARY IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD Some states and provinces do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damag
13. es so these exclusions or limitations may not apply to you This warranty gives you specific legal rights You may also have other rights which vary from state to state and province to province Proof of purchase is required before a warranty claim will be accepted CUSTOMER SERVICE Toll Free 800 465 7300 Our Customer Service team is available to assist you with product questions service center locations and replacement parts They can be reached Monday through Friday 8am 4pm Eastern Please have your model number available as well as the type and style located on the label inside of your product Please do not return product to place of purchase www airkinglimited com PARTS FOR DISCONTINUED OBSOLETE AND CERTAIN OTHER PRODUCTS MAY NOT BE AVAILABLE DUE TO SAFETY REASONS MANY ELECTRONIC COMPONENTS AND MOST HEATER COMPONENTS ARE NOT AVAILABLE TO CONSUMERS FOR INSTALLATION OR REPLACEMENT Description Replacement Part Fan Housing 581202001 Mounting Rails 581299002 Collar 581299003 Damper 581299004 Blower Assembly 582202001 Blower Wheel 582202003 Wire Compartment Assembly 581202004 6 x 3 8 Screw 581999010 8 x 5 8 Screw 5819990114 Grill 581202005 Grill Springs 581202006 WO CO N or B co Po 10 32 x 3 8 Ground Screw 551999002 14 ga Ground Wire 581999003 6 x 3 8 Screw 551999010 External Wire Cover 551202007 Knob 591299802 Motor Cap Harness 589202502
14. eut tre verrouill fixer solidement un avis d avertissement tel qu une tiquette au panneau de distribution AVERTISSEMENT POUR R DUIRE LES RISQUES D INCENDIE DE CHOC ELECTRIQUE OU DE BLESSURES PERSONNELLES OBSERVER CE QUI SUIT a Le travail d installation et le c blage lectrique doivent tre effectu s par une des personne s qualifi e s en conformit avec tous les codes et normes applicables incluant la construction relative aux incendies b De l air en quantit suffisante est requis pour la bonne combustion et l vacuation de gaz par le conduit chemin e provenant d quipement de br lage au combustible pour pr venir un refoulement Suivre les directives du fabricant de l quipement de chauffage et les normes de s curit telles que celles publi es par la National Fire Protection Association NFPA et de la American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et de celles des autorit s locales du code c Lors de coupe ou de per age des murs et plafonds ne pas endommager le filage lectrique et autres utilit s cach es d Les ventilateurs avec conduits doivent toujours tre vacu s vers l ext rieur e Si cette unit doit tre install e au dessus d une baignoire ou d une douche elle doit tre marqu e comme appropri pour l application et tre reli e un GFCI disjoncteur de fuite la terre circuit lectrique prot g f Cette unit d
15. he fan Connect the ground wire from the house to the green wire from the fan housing Figure 8 Use approved methods for all connections Supply from house NOTE The fan s receptacle wires might need to be pulled outside compartment for connection Only pull the three loose wires outside of compartment Additional wires will be present 4 Carefully tuck wire back inside wire compartment and replace wire compartment cover securing with the screw that was removed earlier SECTION 6 Completing the Installation 1 Ifthe fan s blower assembly was removed during the wiring process reinstall the blower by reversing the directions in Section 5 Wiring Step 7b 2 Connect the wire harness by plugging the 3 pin quick connect end into the receptacle located on the side of the wire compartment cover Confirm that the 5 pin quick connect end is plugged into the receptacle from the blower assembly These cords will only fit one way into the receptacles Figure 9 3 Install the grill by squeezing the two ends of the springs together and installing them up into the slots on the fan s housing Push the grill up into position Figure 10 4 SECTION 7 Setting the Humidistat This fan is equipped with a humidity sensor that automatically turns the fan on when humidity is above set point and off when humidity is at or below set point If the fan is operating too long or not enough first check
16. ilateur Connectez correctement le fil de terre et neutre le cas ch ant installez le commutateur et le couvercle 3 Apartir de l endroit o vous avez choisi d acc der la bo te de jonction du ventilateur connectez le fil blanc de la maison au fil blanc du ventilateur Connectez le fil de la position automatique sur l interrupteur mural au fil noir du ventilateur connectez le fil de la position manuelle sur l interrupteur au fil rouge du ventilateur Connectez le fil de terre de la maison au fil vert du bo tier du ventilateur Figure 8 Utiliser des m thodes approuv es pour toutes les connexions Alimentation provenant de la r sidence REMARQUE les fils du r ceptacle du ventilateur pourraient n cessiter d tre tir s l ext rieur du compartiment pour le raccordement Tirer uniquement les trois fils laches l ext rieur du compartiment Des fils additionnels y sont pr sents 4 Regrouper soigneusement les fils l int rieur du compartiment pour le raccordement et replacer le couvercle du compartiment en le fixant avec la vis qui fut enlev e pr c demment SECTION 6 Compl tion de l installation 1 Sil assemblage de la soufflante du ventilateur a t enlev durant le processus de raccordement r installer la soufflante en inversant les instructions l tape 1b de la Section 5 C blage 2 Connectez le faisceau lectrique en branchant l extr mit de 3 broches de c
17. la meilleure performance du d bit d air et sonore il est recommand que la longueur des conduits et que le nombre de coudes soient gard s au minimum et que des conduits rigides isol s soient utilis s Ce ventilateur n cessitera au moins 20 3cm 8po de d gagement dans le plafond ou le mur et s installe au travers de cloison s che d une paisseur de jusqu 1 9cm 3 4po Le ventilateur s installe entre 40 6cm ou 61cm 16po ou 24po au centre des solives l aide des quatre 4 traverses de montage incluses 3 S lectionner l alv ole d fon able la mieux appropri e et l enlever l aide d un tournevis lame plate Figure 1 S SECTION 2 Nouvelle Construction Figure 1 1 Installer les traverses sur le chassis et positionner le ch ssis pr s de la solive Aligner le ch ssis pour qu il soit effleurement avec le plafond fini Fixer les extr mit s des traverses avec des clous ou des vis non comprises aux solives et glisser le ch ssis sa position finale Figure 2 Traverses de Montage SECTION 3 Construction Existante 1 Placer le ch ssis en position entre les solives et tracer un contour sur le mat riau du plafond Figure 3 Mettre le ch ssis de c t et d couper l ouverture en prenant soin de ne pas couper ou endommager des c bles lectriques dissimul s ou autres utilit s Installer les traverses sur le ch ssis et positionner le ch ssis dans le trou perc p
18. mbustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities d e Ducted fans must always be vented to the outdoors If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit This unit must be grounded To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit NEVER place a switch where it can be reached from a tub or shower Suitable for use with electronic speed control device Do not install into ceilings thermally insulated to a value greater than R40 CAUTION FOR GENERAL VENTILATING USE ONLY DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS WARNING DO NOT USE IN KITCHENS k Read all instructions before installing or using exhaust fan SAVE THESE INSTRUCTIONS WWW AIRKINGLIMITED COM 1of8 INSTALLATION INSTRUCTIONS CAUTIONS make sure POWER IS SWITCHED
19. oit tre mise la terre g Pour viter des dommages aux roulements des moteurs et ou des h lices bruyantes ou d s quilibr es emp cher la poussi re de cloison s che poussi re de construction etc d atteindre l unit de puissance h NE JAMAIS placer un interrupteur un endroit qui puisse tre atteint de la baignoire ou de la douche i Appropri pour l usage avec le dispositif de commande lectronique de vitesse j N installez pas sur des plafonds thermiquement isol s une valeur plus grande que R40 AVERTISSEMENT POUR USAGE DE VENTILATION GENERALE EXCLUSIVEMENT NE PAS UTILISER POUR EVACUER DU MATERIEL ET DES VAPEURS DANGEREUSES OU EXPLOSIVES AVERTISSEMENT NE PAS UTILISER DANS LES CUISINES k Bien lire toutes les instructions avant d installer ou d utiliser le ventilateur d vacuation CONSERVER CES INSTRUCTIONS 5084461 New 3 12 WWW AIRKINGLIMITED COM 5of8 INSTRUCTIONS D INSTALLATION AVERTISSEMENT vous ASSURER QUE L ALIMENTATION EST COUPEE AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION SECTION 1 Pr paration du Ventilateur d vacuation 1 Sortir le ventilateur de sa boite et confirmer que toutes les pi ces sont pr sentes En plus du ventilateur d vacuation vous devriez avoir 1 Grille 4 Traverses de Montage 1 Ensemble de clapet attach 1 Feuillet d instructions s curit 2 Choisir un emplacement pour votre ventilateur Pour assurer
20. onnexion rapide dans la prise situ e sur le c t du couvercle du compartiment de fil Assurez vous que l extr mit de 5 broches de connexion rapide est branch e dans la prise du ventilateur Ces fils ne peuvent tre ins r s que dans un seul sens dans les prises Figure 9 Trouble Cause Possible 1 Le ventilateur ne fonctionne pas lorsque l interrupteur est la position en marche peut tre d cle nch 1b La fiche de raccord du moteur n est pas connect e 1d La moteur est terminee 1a Un fusible peut tre grill ou un disjoncteur 1c Le c blage n est pas raccord correctement 3 Installer la grille en pressant ensemble les deux extr mit s des ressorts et en les installant dans les fentes du ch ssis du ventilateur Pousser la grille en position Figure 10 Figure 10 4 Restaurer l alimentation et tester votre installation SECTION 7 R glage de l humidostat Ce ventilateur est quip d un capteur d humidit qui allume automatiquement le ventilateur ou hausse la vitesse pour les mod les deux vitesses lorsque l humidit est sup rieure au point de consigne ou baisse la vitesse pour les mod les deux vitesses lorsque l humidit est inf rieure ou gale au point de consigne Si le ventilateur fonctionne trop longtemps ou pas assez v rifiez d abord le point de consigne du capteur d humidit Dans le cas o le niveau d humidit ambiante de la pi ce s l ve plu
21. r c demment afin qu il soit effleurement avec le plafond fini Fixer les extr mit s des traverses aux solives Figure 2 Solive Figure 3 SECTION 4 Conduits AVERTISSEMENT rous LES CONDUITS DOIVENT TRE CONFORMES AUX CODES DU B TIMENT LOCAUX ET NATIONAUX 5084461 New 3 12 1 Raccorder le conduit au collet de conduit du ventilateur Figure 4 Fixer en place l aide de ruban ou de serre joint Toujours vacuer le ventilateur vers l ext rieur au travers de chapeau mural ou de toit Conduits Collet du Conduit SECTION 5 Cablage AVERTISSEMENT vous ASSURER QUE L ALIMENTATION EST COUPEE AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION AVERTISSEMENT toutes LES CONNEXIONS DOIVENT TRE FAITES EN CONFORMIT AVEC LES CODES LECTRIQUES LOCAUX OU NATIONAUX SI VOUS N TES PAS FAMILIER AVEC LES M THODES D INSTALLATION DE CABLAGE LECTRIQUE RECOURREZ AUX SERVICES D UN ELECTRICIEN QUALIFI REMARQUE cette unit poss de un panneau d acc s lat ral pour le c blage qui ne requiert pas l enl vement de l assemblage de la soufflante du ventilateur Si vous choisissez de raccorder l unit par l int rieur vous aurez besoin d enlever l assemblage de la soufflante et le compartiment de c blage int rieur Les deux m thodes sont galement efficaces ta Compartiment de C blage Ext rieur enlever la vis du couvercle du compartiment c blage et mettre ce couvercle dans
22. s haut que le niveau pr r gl le ventilateur s allumera m me si la salle n est pas occup e Ceci aide viter les conditions qui m nent la croissance de moisissures AVERTISSEMENT vous ASSURER QUE L ALIMENTATION EST COUPEE AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION 1 Pour r gler le niveau d sir d humidit de la salle enlevez la grille et localisez le cadran de I humidostat situ sur le couvercle du compartiment de fil 2 R glez le cadran l humidit relative que vous vous voulez que le ventilateur maintienne habituellement entre 50 et 80 Les climats humides exigeront des r glages plus lev s que les climats secs Lorsque le niveau d humidit de la salle est inf rieur ce r glage le ventilateur restera teint Lorsque le niveau d humidit monte ce r glage le ventilateur s allumera et fonctionnera jusqu ce que le niveau d humidit tombe au dessous de ce r glage 3 R installer la grille et r tablir le courant SECTION 8 Utilisation et entretien AVERTISSEMENT vous ASSURER QUE L ALIMENTATION EST COUPEE AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION 1 Nettoyage de la grille Retirer la grille et utiliser un d tergent doux tel que du liquide pour la vaisselle puis s cher l aide d un chiffon doux NE JAMAIS UTILISER D ABRASIF OU DE POUDRE RECURER S cher compl tement la grille avant de la r installer Pour r installer la grille
23. t the venturi up and at an angle to slide it out of the housing Figure 6 Remove the wire compartment cover screw and place the cover in a secure place Figure 7 Venturi Figure 6 Humidity Set Point Knob Wire Compartment Cover NOTE If the fan motor plug is connected to the fan housing receptacle unplug so the blower assembly can be completely removed WWW AIRKINGLIMITED COM 20f8 2 For proper operation the humidity sensing fan will require a 3 way switch not included Run wiring between the fan and the switch location Make sure you leave enough wiring in each box to make the connections At the switch box connect the Black wire from the house to the common terminal of the switch Connect the black wire from the fan to one of the switched terminals on the switch This position will energize the automatic mode and the fan will energize upon a rise in humidity Connect the Red wire from the fan to the other switched terminal on the switch This position will activate the Manual On feature and energize the fan Properly connect the ground and neutral if applicable mount the switch and the cover 3 From where you have chosen to access the fan s junction box connect the white wire from the house to the white wire from the fan Connect the wire from the automatic position on the wall switch to the black wire from the fan connect the wire from the manual On position on the switch to the red wire from t