Home
Air King ESB130SH Instructions / Assembly
Contents
1. Models ES80SH ES130SH ES80DH ES130DH IMPORTANT INSTRUCTIONS OPERATING MANUAL Ventilation Products READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE INSTALL OPERATE OR MAINTAIN THE PRODUCT DESCRIBED PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE RETAIN INSTRUCTIONS FOR FUTURE REFERENCE GENERAL SAFETY INFORMATION When using electrical appliances basic precautions should always be followed to reduce the risk of fire electric shock and injury to person including the following TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK AND INJURY TO PERSON OBSERVE THE FOLLOWING a b Use this unit only in the manner intended by the manufacturer lf you have questions contact the manufacturer Before servicing or cleaning the unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK AND INJURY TO PERSON OBSERVE THE FOLLOWING a 6728020 New 3 12 Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire related construction Sufficien
2. une mau vaise manipulation ou op ration de dommages d exp dition d abus de mauvaise utilisation de r paration faite ou tent es non autoris es Cette garantie ne couvre pas les co ts d exp dition pour le retour des produits Air King pour la r paration ou le remplacement Air King payera les frais d exp dition de retour de Air King apr s les r parations ou le remplacement de garantie TOUTES LES GARANTIES EXPRESSES OU TACITES COMPRENANT SANS LIMITATION TOUTE GARANTIE TACITE DE VALEUR MARCHANDE DURENT UN AN DE LA DATE DE L ACHAT ORIGINAL OU JUSQU CE QUE L ACHETEUR ORIGINAL DU PRODUIT VEND OU TRANSF RE LE PRODUIT CELUI QUI SE PRODUIT EN PREMIER ET DANS AUCUN CAS AIR KING N ASSUME AUCUNE RESPONSABILIT EXPRESSE OU TACITE POUR I DES DOMMAGES ACCIDENTELS OU INDIRECTS DE N IMPORTE QUELLE CAUSE OU I LE REPLACEMENT OU LA R PARATION DE TOUS FUSIBLES DISJONCTEURS OU RECEPTACLES DE MAISON MALGR N IMPORTE QUOI L EFFET CONTRAIRE DANS AUCUN CAS LA RESPONSABILIT D AIR KING SOUS UNE GARANTIE EXPRESSE OU TACITE NE DEPASSERA LE PRIX D ACHAT DU PRODUIT ET UNE TELLE RESPONSABILITE SE TERMINERA AVEC L EXPIRATION DE LA P RIODE DE GARANTIE Certains tats et provinces ne permettent pas les limitations de la p riode de garantie ou l exclusion ou la restriction des dommages accidentels ou indirects et par con s quent les pr sentes restrictions ne peuvent pas s appliquer La pr sente garantie vous donne des droits l gaux
3. 581299002 Assembl e du compartiment du fil ES80S ES130D 551299801 3 1 Assembl e de la Soufflante 5S2239008 Faisceau lectrique ES80S ES130S 552239002 4 Assembl e de collier en m tal de 6 po 555299100 Faisceau lectrique ES80S ES130S 582239003 5 4 Vis 5S 1999010 Assembl e du compartiment du fil ES80D ES130D 5S1299803 6 Joint Collet 581202054 Vis 6 de la couverture du fil 5S1999111 7 Joint Ext rieur 581202053 Bouton 581299802 8 Grille 581202048 Vis de la bride 581202049 9 2_ Ressorts de la grille 981202046 Bride du plafond 581202050 10 2 Ecrou de la bride 991202031 Canal de montage 981239021 11 2 Passe fil 581202032 Ecrou du Canal de montage 5S1202041 12 1 Vis 10 de mise la terre 581999002 6728020 New 3 12 WWW AIRKINGLIMITED COM 12 of 12
4. CES INSTRUCTIONS 6728020 New 3 12 WWW AIRKINGLIMITED COM 7 of 12 INSTRUCTIONS D INSTALLATION AVERTISSEMENT vous ASSURER QUE L ALIMENTATION EST COUPEE AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION SECTION 1 Pr paration du Ventilateur d vacuation 1 Sortir le ventilateur de sa boite et confirmer que toutes les pi ces sont pr sentes En plus du ventilateur d vacuation vous devriez avoir 1 Grille 1 Ensemble de clapet attach 4 Supports de montage 1 Bride de montage 1 Feuillet d instructions s curit 2 Choisir un emplacement pour votre ventilateur Pour assurer la meilleure performance du d bit d air et sonore il est recommand que la longueur des conduits et que le nombre de coudes soient gard s au minimum et que des conduits rigides isol s soient utilis s Ce ventilateur n cessitera au moins 20 3cm 8po de d gagement dans le plafond ou le mur et s installe au travers de cloison s che d une paisseur de jusqu 1 9cm 3 4po 3 S lectionner l alv ole d fon able la mieux appropri e et l enlever l aide d un S tournevis a lame plate Figure 1 Figure 1 SECTION 2 Nouvelle Construction 1 Installer les traverses sur le chassis et positionner le ch ssis pr s de la solive Aligner le chassis pour qu il soit a effleurement avec le plafond fini Fixer les extr mit s des traverses avec des clous ou des vis non comprises aux solives et g
5. pour la ventilation continue connectez le fil blanc du ventilateur au fil neutre blanc de la source d alimentation Connectez le fil de terre de la maison au fil vert du bo tier du ventilateur Connectez le fil noir du ventilateur au fil noir chaud de la source d alimentation Le ventilateur fonctionnera vitesse r duite continuellement et augmentera de vitesse lors d une l vation d humidit Vous pouvez utiliser un commutateur de priorit manuelle non inclus pour fournir la fonction manuelle ARR T au ventilateur Figure 9 Alimentation provenant de la r sidence REMARQUE Les fils du r ceptacle du ventilateur pourraient n cessiter d tre tir s l ext rieur du compartiment pour le raccordement Tirer uniquement les trois fils laches l ext rieur du compartiment Des fils additionnels y sont pr sents 4 Regrouper soigneusement les fils l int rieur du compartiment pour le raccordement et replacer le couvercle du compartiment en le fixant avec la vis qui fut enlev e pr c demment SECTION 6 Compl tion de l installation 1 WWW AIRKINGLIMITED COM Si l assemblage de la soufflante du ventilateur a t enlev durant le processus de raccordement r installer la soufflante en inversant les instructions l tape 1b de la Section 4 C blage Branchez le cordon de connexion rapide 3 broches du moteur dans le r ceptacle situ sur le c t du couvercle du compartime
6. unit poss de un panneau d acc s lat ral pour le c blage qui ne requiert pas l enl vement de l assemblage de la soufflante du ventilateur Si vous choisissez de raccorder l unit par l int rieur vous aurez besoin d enlever l assemblage de la soufflante et le compartiment de c blage int rieur Les deux m thodes sont galement efficaces 1a Compartiment de Cablage Ext rieur Enlever la vis du couvercle du compartiment c blage et mettre ce couvercle dans un endroit fiable Figure 5 Couvercle du Compartiment de Cablage WWW AIRKINGLIMITED COM 8 of 12 1b Compartiment de Cablage Int rieur Enlever les trois vis retenant en place l assemblage de la soufflante et soulever pour sortir l assemblage hors du ch ssis Figure 6 Enlever la vis du couvercle du compartiment c blage et mettre ce couvercle dans un endroit fiable Figure 7 Raccord crou Hexagonal Figure 6 REMARQUE Si le raccord du moteur de ventilateur est raccord au r ceptacle du ch ssis le d brancher afin que l assemblage de la soufflante soit compl tement enlev Bouton de point de consigne d humidit Couvercle du Compartiment de Cablage Figure 7 REMARQUE La configuration du compartiment de fil d pendra du mod le UNIT S UNE VITESSE mod les ES80SH et ES130SH 2a Pour un bon fonctionnement le ventilateur de d tection d humidit 2b 6728020 New 3 12 exigera un interrupte
7. ION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION SECTION 1 Preparing the Exhaust Fan 1 Unpack fan from the carton and confirm that all pieces are present In addition to the exhaust fan you should have 1 Grill 1 Damper Assembly attached 4 Mounting Rails 1 Mounting Flange 1 Instruction Safety Sheet 2 Choose the location for your fan To ensure the best air and sound performance it is recommended that the length of ducting and the number of elbows be kept to a minimum and that insulated hard ducting be used Larger duct sizes will reduce noise and airflow restrictions This fan will require at least 10 of clearance in the ceiling or wall and will mount through drywall up to 3 4 thick 3 Select the most convenient electrical S knockout and remove using a straight blade screw driver Figure 1 Figure 1 SECTION 2 New Construction 1 Install the rails on the housing and position the housing next to the joist Line up housing so that it will be flush with the finished ceiling Secure the ends of the rails with screws or nails not included to the joists and slide the housing into the final position Figure 2 N Mounting Rails SECTION 3 Existing Construction 1 Set housing in position between the joist and trace an outline onto the ceiling material Figure 3 Set housing aside and cut opening being careful not to cut or damage any electrical or oth
8. SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD Some states and provinces do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so these exclusions or limitations may not apply to you This warranty gives you specific legal rights You may also have other rights which vary from state to state and province to province Proof of purchase is required before a warranty claim will be accepted CUSTOMER SERVICE Toll Free 800 465 7300 Our Customer Service team is available to assist you with product questions service center locations and replacement parts They can be reached Monday through Friday 8am 4pm Eastern Please have your model number available as well as the type and style located on the label inside of your product Please do not return product to place of purchase www airkinglimited com PARTS FOR DISCONTINUED OBSOLETE AND CERTAIN OTHER PRODUCTS MAY NOT BE AVAILABLE DUE TO SAFETY REASONS MANY ELECTRONIC COMPONENTS AND MOST HEATER COMPONENTS ARE NOT AVAILABLE TO CONSUMERS FOR INSTALLATION OR REPLACEMENT Installer Installation Date Place of Purchase Model Number 6728020 New 3 12 WWW AIRKINGLIMITED COM Sof 12 REPLACEMENT PARTS DIAGRAM SINGLE SPEED UNITS Description Replacement Part Description Replacement Part Fan Housing 981239009 1 14 ga Ground Wire 981999003 Mounting Rails 951299002 1 Wire Compartme
9. ablir le courant SECTION 8 Utilisation et entretien AVERTISSEMENT VOUS ASSURER QUE L ALIMENTATION EST COUP E AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION 1 Nettoyage de la grille Retirer la grille et utiliser un d tergent doux tel que du liquide pour la vaisselle puis s cher l aide d un chiffon doux NE JAMAIS UTILISER D ABRASIF OU DE POUDRE RECURER S cher compl tement la grille avant de la r installer Pour r installer la grille vous r f rer la Section 6 Compl tion de l installation 2 Nettoyage de l assemblage du ventilateur Nettoyer toutes les parties l aide d un chiffon sec ou passer d licatement l aspirateur sur le ventilateur NE JAMAIS IMMERGER LES PARTIES LECTRIQUES DANS L EAU 10 of 12 Guide de d pannage Trouble Cause Possible Solution Sugg r e 1 Le ventilateur ne fonctionne pas lorsque Un fusible peut tre grill ou un disjoncteur Remplacer le fusible ou r initialiser le disjoncteur l interrupteur est la position en marche peut tre d cle nch La fiche de raccord du moteur n est Couper l alimentation l unit Retirer la grille et brancher le moteur dans pas connect e le r ceptacle dans le cabinet Remettre l alimentation sur l unit Le c blage n est pas raccord correctement Couper l alimentation de l unit V rifier que tous les fils sont raccord s La moteur est terminee Remplacez la moteur 2 Le ventilat
10. all the blower by reversing the directions in Section 4 Wiring Step 1b 2 Plug the fan s 3 pin quick connect motor cord into the receptacle located on the side of the wire compartment cover Plug the 2 pin quick connect motor cord into the receptacle from the capacitor on single speed models ES80SH ES130SH or on the side of the wire compartment on dual speed models ES80DH ES130DH These cords will only fit one way into the receptacles Figure 10 SINGLE SPEED UNITS 8 H DUAL SPEED UNITS Ae 3 Install the ceiling mounting flange to cover any gaps which exist between the housing and the finished ceiling Line up the slots in the ceiling mounting flange with the screws on the inside of the housing and press flange in place so it is tight against the ceiling Tighten both screws inside the housing Install drywall screws not included through the holes in the flange and into the ceiling Install as many drywall screws needed to ensure the flange fits tightly against the ceiling Figure 11 WWW AIRKINGLIMITED COM 3 of 12 Ceiling Mounting Flange Figure 11 4 Install the grill by squeezing the two ends of the springs together and installing them up into the slots on the fan s housing Push the grill up into position Figure 12 5 Restore power and test your installation 6728020 New 3 12 SECTION 7 Setting the Humidistat This fan is equipped with a humidity sensor that automatic
11. ally turns the fan on or to high speed on dual speed models when humidity is above set point and off or back to low speed on dual speed models when humidity is at or below set point If the fan is operating too long or not enough first check to see the humidity sensor set point In cases where the ambient humidity level of the room rises higher than the preset level the fan will turn on even if the room is not occupied This helps prevent conditions that lead to mold growth CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT 1 To set the desired humidity level of the room remove the grill and locate the dehumidistat dial located on the wire compartment cover 2 Set the dial to the relative humidity you want the fan to maintain usually between 50 amp 80 Moist climates will require higher settings than dry climates When the humidity level of the room is below this setting the fan will remain off When the humidity level rises about this setting the fan will turn on and run until the humidity level falls below this setting 3 Reinstall the grill and restore power SECTION 8 Use and Care CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT 1 Cleaning the Grill Remove grill and use a mild detergent such as dishwashing liquid and dry with a soft cloth NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS Completely dry grill before reinstalling Refer to instru
12. can Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et de celles des autorit s locales du code c Lors de coupe ou de per age des murs et plafonds ne pas endommager le filage lectrique et autres utilit s cach es d Les ventilateurs avec conduits doivent toujours tre vacu s vers l ext rieur e Si cette unit doit tre install e au dessus d une baignoire ou d une douche elle doit tre marqu e comme appropri pour l application et tre reli e un GFCI disjoncteur de fuite la terre circuit lectrique prot g f Cette unit doit tre mise la terre g Pour viter des dommages aux roulements des moteurs et ou des h lices bruyantes ou d s quilibr es emp cher la poussi re de cloison s che poussi re de construction etc d atteindre l unit de puissance h NE JAMAIS placer un interrupteur un endroit qui puisse tre atteint de la baignoire ou de la douche i Appropri pour l usage avec le dispositif de commande lectronique de vitesse j N installez pas sur des plafonds thermiquement isol s une valeur plus grande que R40 AVERTISSEMENT POUR USAGE DE VENTILATION GENERALE EXCLUSIVEMENT NE PAS UTILISER POUR EVACUER DU MATERIEL ET DES VAPEURS DANGEREUSES OU EXPLOSIVES AVERTISSEMENT NE PAS UTILISER DANS LES CUISINES k Bien lire toutes les instructions avant d installer ou d utiliser le ventilateur d vacuation CONSERVER
13. ctions in Section 5 Finishing the Installation to reinstall grill 2 Cleaning the Fan Assembly Wipe all parts with a dry cloth or gently vacuum the fan NEVER IMMERSE ELECTRICAL PARTS IN WATER WWW AIRKINGLIMITED COM 4 of 12 Troubleshooting Guide Trouble Probable Cause Suggested Remedy 1 Fan does not operate when the switch is on A fuse may be blown or a circuit tripped Replace fuse or reset circuit breaker Connector plug from motor is not plugged in Turn off power to unit Remove Grill and plug motor into receptacle in housing Restore power to unit Wiring is not connected properly Turn off power to unit Check that all wires are connected Motor has stopped operating Replace motor 2 Fan is operating but air moves slower than normal Obstruction in the exhaust ducting Check for any obstructions in the ducting The most common are bird nests in the roof cap or wall cap where the fan exhausts to the outside 3 Fan is operating louder than normal Motor is loose _ Turn off power to unit Remove grill and check that all screws are fully tightened Restore power to unit Fan blade is hitting housing of unit Call your dealer for service LIMITED WARRANTY WHAT THIS WARRANTY COVERS This product is warranted against defects in workmanship and or materials HOW LONG THIS WARRANTY LASTS This warranty extends only to the original purchaser of the product and lasts for five 5 y
14. ears from the date of original purchase or until the original purchaser of the product sells or transfers the product whichever first occurs WHAT AIR KING WILL DO During the warranty period Air King will at its sole option repair or replace any part or parts that prove to be defective or replace the whole product with the same or comparable model WHAT THIS WARRANTY DOES NOT COVER This warranty does not apply if the product was damaged or failed because of accident improper handling or operation shipping damage abuse misuse unauthorized repairs made or attempted This warranty does not cover shipping costs for the return of products to Air King for repair or replacement Air King will pay return shipping charges from Air King following warranty repairs or replacement ANY AND ALL WARRANTIES EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY LAST ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS THE PRODUCT WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACMENT OR REPAIR OF ANY HOUSE FUSES CIRCUIT BREAKERS OR RECEPTACLES NOTWITHSTANDING ANYTHING TO THE CONTRARY IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT AND ANY SUCH LIABILITY
15. er hidden utilities Install the rails on the housing and position the housing in the previously cut hole so that it is flush with the finished ceiling Secure the ends of the rails to the joists Figure 3 6728020 New 3 12 SECTION 4 Ducting CAUTION ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES 1 Connect the ducting to the fan s duct collar Figure 4 Secure in place using tape or screw clamp Always duct the fan to the outside through a wall or roof cap Ducting Duct l Collar SECTION 5 Wiring CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION CAUTION ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE WITH LOCAL CODES ORDINANCES OR NATIONAL ELECTRICAL CODE IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN NOTE This unit includes a side access panel for wiring that does not require the removal of the fan s blower assembly If you choose to wire the unit from the inside you will need to remove the blower assembly and internal wiring compartment Both methods are equally effective 1a External Wire Compartment Remove the wire compartment cover screw and place cover in a secure place Figure 5 Wire Compartment Cover WWW AIRKINGLIMITED COM 2 of 12 1b Internal Wire Compartment Using a 7 16 socket remove the two hex nuts holding the blower assembl
16. eur fonctionne mais l air circule Obstruction dans les conduits d vacuation V rifier pour toute obstruction dans les conduits Les plus courantes sont plus lentement que la normale des nids d oiseau dans le chapeau de toit ou mural l o le ventilateur s vacue vers l ext rieur 3 Le ventilateur fonctionne de mani re plus Le moteur est l che Couper l alimentation l unit Retirer la grille et v rifier que toutes les bruyante que la normale vis sont compl tement serr es Remettre l alimentation sur l unit L h lice du ventilateur frotte contre le cabinet de l unit Appeler votre marchand pour un service GARANTIE LIMIT E QUE COUVRE CETTE GARANTIE Ce produit est garanti contre tout vice de fabrication ou de mati re COMBIEN DE TEMPS CETTE GARANTIE DURE Cette garantie se rapporte seulement l acheteur original du produit et dure pendant cinq 5 ann es de la date de l achat original ou jusqu ce que l acheteur original du produit vend ou transf re le produit celui qui se produit en premier QUE FERA AIR KING Au cours de la p riode de garantie Air King son choix r parera ou remplacera n importe quelle partie ou pi ces qui s av rent d fectueuses ou remplacera le produit entier par le m me mod le ou un mod le comparable CE QUE CETTE GARANTIE NE COUVRE PAS Cette garantie ne s applique pas si le produit tait endommag ou arr te de fonctionner en raison d un accident d
17. lack wire from the fan connect the wire from the manual On position on the switch to the red wire from the fan Connect the ground wire from the house to the green wire from the fan housing Figure 8 Use approved methods for all connections Supply from house TWO SPEED UNITS models ES80DH and ES130Dh 3 Continuous Ventilation For two speed fans wired for continuous ventilation connect the White wire of the fan to the White Neutral wire from the power source Connect the ground wire from the house 6728020 New 3 12 to the green wire from the fan housing Connect the Black wire of the fan to the Black wire Hot from the power source The fan will operate on low speed continuously and boost to high upon a rise in humidity A manual override switch not included can be used to provide a manual fan Off function Figure 9 Supply from house Ground White Hot Black NOTE The fan s receptacle wires might need to be pulled outside compartment for connection Only pull the five loose wires outside of compartment Additional wires will be present NOTE Unit must be grounded according to all local and national codes 4 Carefully tuck wire back inside wire compartment and replace wire compartment cover securing with the screw that was removed earlier SECTION 6 Completing the Installation 1 If the fan s blower assembly was removed during the wiring process reinst
18. lisser le chassis a sa position finale Figure 2 Solive oS Traverses de Montage SECTION 3 Construction Existante 1 Placer le chassis en position entre les solives et tracer un contour sur le mat riau du plafond Figure 3 Mettre le chassis de c t et d couper l ouverture en prenant soin de ne pas couper ou endommager des c bles lectriques dissimul s ou autres utilit s Installer les traverses sur le ch ssis et positionner le ch ssis dans le trou perc pr c demment afin qu il soit effleurement avec le plafond fini Fixer les extr mit s des traverses aux solives Figure 2 6728020 New 3 12 SECTION 4 Conduits AVERTISSEMENT TOUS LES CONDUITS DOIVENT TRE CONFORMES AUX CODES DU B TIMENT LOCAUX ET NATIONAUX 1 Raccorder le conduit au collet de conduit du ventilateur Figure 4 Fixer en place l aide de ruban ou de serre joint Toujours vacuer le ventilateur vers l ext rieur au travers de chapeau mural ou de toit Conduits Collet du Cr SECTION 5 C blage AVERTISSEMENT VOUS ASSURER QUE L ALIMENTATION EST COUP E AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION AVERTISSEMENT TOUTES LES CONNEXIONS DOIVENT TRE FAITES EN CONFORMIT AVEC LES CODES LECTRIQUES LOCAUX OU NATIONAUX SI VOUS N TES PAS FAMILIER AVEC LES M THODES D INSTALLATION DE C BLAGE LECTRIQUE RECOURREZ AUX SERVICES D UN ELECTRICIEN QUALIFI REMARQUE Cette
19. nt Assembly ES80S ES130S 981299801 Blower Assembly 582239008 1 Wire Harness ES80S 582239002 6 Metal Collar Assembly 989299100 Wire Harness ES130S 982239003 Screws 951999010 1 Wire Compartment Assembly ES80D ES130D 551299803 Collar Gasket 551202054 1 Wire Cover Screw 6 551999111 Outlet Gasket 581202053 1 Knob 581299802 Grill 951202048 1 Flange Screw 981202049 Grill Springs 981202046 Ceiling Flange 981202050 Flange Nut 991202031 Mounting Channel 981239021 Grommets 981202032 Mounting Channel Nut 981202041 10 Ground Screw 551999002 1 2 3 4 5 6 7 8 9 6728020 New 3 12 WWW AIRKINGLIMITED COM 6of12 INSTRUCTIONS IMPORTANTES MODE D EMPLOI Mod les ES80SH ES130SH ES80DH ES130DH Ventilation Products Ventilateur d Evacuation LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D ASSEMBLER INSTALLER OPERER OU DE R PARER LE PRODUIT DECRIT PROT GEZ VOUS M ME ET LES AUTRES EN OBSERVANT TOUTE L INFORMATION DE S CURIT FAILLIR A SE CONFORMER AUX INSTRUCTIONS PEUT R SULTER EN BLESSURE PERSONNELLE GRAVE ET OU EN DOMMAGE LA PROPRI T CONSERVER CES INSTRUCTIONS POUR R F RENCES FUTURES INSTRUCTIONS G N RALES DE S CURIT Lors de l utilisation d appareils lectriques des pr cautions de base doivent toujours tre suivies pour r duire les risques d incendie de choc lec
20. nt de fil Branchez le cordon de connexion rapide 2 broches du moteur dans le r ceptacle du condensateur pour les mod les une vitesse ES80SH ES130SH ou sur le c t du compartiment de fil pour les mod les deux vitesses ES80DH ES1 30DH Ces cordons ne peuvent tre ins r s que dans un seul sens dans les r ceptacles Figure 10 UNIT S UNE VITESSE al a UNITES A DEUX VITESSES 9 of 12 3 Installer la bride de montage du plafond pour couvrir tout espacement qui existe entre le chassis et le plafond fini Aligner les fentes dans la bride de montage du plafond avec les vis l int rieur du chassis et presser la bride en place de sorte qu elle soit bien serr e contre le plafond Serrer les deux vis l int rieur du chassis Installer des vis pour cloison s che non comprises au travers des trous dans la bride et dans le plafond Installer autant de vis pour cloison s che que requis pour assurer que la bride s ajuste solidement contre le plafond Figure 11 Bride de Montage du Plafond 4 Installer la grille en pressant ensemble les deux extr mit s des ressorts et en les installant dans les fentes du chassis du ventilateur Pousser la grille en position Figure 12 5 Restaurer l alimentation et tester votre installation 6728020 New 3 12 WWW AIRKINGLIMITED COM SECTION 7 R glage de l humidostat Ce ventilateur est quip d un capteur d humidit
21. qui allume automatiquement le ventilateur ou hausse la vitesse pour les mod les deux vitesses lorsque l humidit est sup rieure au point de consigne ou baisse la vitesse pour les mod les deux vitesses lorsque l humidit est inf rieure ou gale au point de consigne Si le ventilateur fonctionne trop longtemps ou pas assez v rifiez d abord le point de consigne du capteur d humidit Dans le cas o le niveau d humidit ambiante de la pi ce s l ve plus haut que le niveau pr r gl le ventilateur s allumera m me si la salle n est pas occup e Ceci aide viter les conditions qui m nent la croissance de moisissures AVERTISSEMENT VOUS ASSURER QUE L ALIMENTATION EST COUP E AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION 1 Pour r gler le niveau d sir d humidit de la salle enlevez la grille et localisez le cadran de l humidostat situ sur le couvercle du compartiment de fil 2 R glez le cadran l humidit relative que vous vous voulez que le ventilateur maintienne habituellement entre 50 et 80 Les climats humides exigeront des r glages plus lev s que les climats secs Lorsque le niveau d humidit de la salle est inf rieur a ce r glage le ventilateur restera teint Lorsque le niveau d humidit monte a ce r glage le ventilateur s allumera et fonctionnera jusqu a ce que le niveau d humidit tombe au dessous de ce r glage 3 R installer la grille et r t
22. sp cifiques et peut tre certains autres droits qui peuvent varier selon la province La preuve d achat est exig e avant qu une r clamation de garantie ne soit accept e SERVICE LA CLIENT LE Sans frais 800 465 7300 Notre quipe de service la client le est disponible pour vous aider avec des questions sur le produit les adresses des centres de service et les pi ces de rechange Vous pouvez la rejoindre du lundi au vendredi de 8h 00 16h 00 HNE Veuillez avoir le num ro du mod le disponible ainsi que le genre et le style qui se trouvent sur l tiquette l int rieur de votre produit Veuillez ne pas renvoyer le produit l endroit de l achat www airkinglimited com IL SE PEUT QUE LES PIECES POUR LES PRODUITS DISCONTINUES OBSOLETES ET AUTRES PRODUITS NE SOIENT PAS DISPONIBLES POUR DES RAISONS DE S RET BEAUCOUP DE COMPOSANTS LECTRONIQUES ET LA PLUPART DES COMPOSANTS DES CHAUFFAGES NE SONT PAS LA DISPOSITION DES CON SOMMATEURS POUR L INSTALLATION OU LE REMPLACEMENT Installateur Date d installation Endroit de l achat Num ro de mod le 6728020 New 3 12 WWW AIRKINGLIMITED COM 110f12 DIAGRAMME DES PIECES DE REMPLACEMENT Qty Description Replacement Part F Description Replacement Part 1 1 Cabinet du ventilateur 581239009 Fil de mise la terre de calibre 14 551999003 2 4 _ Traverses de Montage
23. t air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities d e Ducted fans must always be vented to the outdoors If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit This unit must be grounded To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit NEVER place a switch where it can be reached from a tub or shower Suitable for use with electronic speed control device Do not install into ceilings thermally insulated to a value greater than R40 CAUTION FOR GENERAL VENTILATING USE ONLY DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS WARNING DO NOT USE IN KITCHENS k Read all instructions before installing or using exhaust fan SAVE THESE INSTRUCTIONS WWW AIRKINGLIMITED COM 1 of 12 INSTALLATION INSTRUCTIONS CAUT
24. trique et de blessures corporelles incluant ce qui suit AVERTISSEMENT POUR R DUIRE LES RISQUES D INCENDIE DE CHOC ELECTRIQUE OU DE BLESSURES PERSONNELLES OBSERVER CE QUI SUIT a Utiliser cette unit seulement de la mani re pour laquelle le fabricant l a con u Si vous aviez des questions veuillez contacter le fabricant b Avant d effectuer un service ou de nettoyer l unit couper l alimentation lectrique dans le panneau de distribution et verrouiller le dispositif de d connexion afin d viter que l alimentation ne revienne accidentellement Lorsque le dispositif ne peut tre verrouill fixer solidement un avis d avertissement tel qu une tiquette au panneau de distribution AVERTISSEMENT POUR R DUIRE LES RISQUES D INCENDIE DE CHOC ELECTRIQUE OU DE BLESSURES PERSONNELLES OBSERVER CE QUI SUIT a Le travail d installation et le c blage lectrique doivent tre effectu s par une des personne s qualifi e s en conformit avec tous les codes et normes applicables incluant la construction relative aux incendies b De l air en quantit suffisante est requis pour la bonne combustion et l vacuation de gaz par le conduit chemin e provenant d quipement de br lage au combustible pour pr venir un refoulement Suivre les directives du fabricant de l quipement de chauffage et les normes de s curit telles que celles publi es par la National Fire Protection Association NFPA et de la Ameri
25. ur 3 voies non inclus Faites passer le c blage entre le ventilateur et l emplacement du commutateur Assurez vous de laisser suffisamment de c blage dans chaque bo te pour faire les connexions la bo te de commutation connectez le fil noir de la maison la borne commune du commutateur Connectez le fil noir du ventilateur l une des bornes commut es sur le commutateur Cette position activera le mode automatique et le ventilateur s activera apr s une l vation d humidit Connectez le fil rouge du ventilateur l autre borne commut e sur le commutateur Cette position activera le mode manuel et activera le ventilateur Connectez correctement le fil de terre et neutre le cas ch ant installez le commutateur et le couvercle partir de l endroit o vous avez choisi d acc der la bo te de jonction du ventilateur connectez le fil blanc de la maison au fil blanc du ventilateur Connectez le fil de la position automatique sur l interrupteur mural au fil noir du ventilateur connectez le fil de la position manuelle sur l interrupteur au fil rouge du ventilateur Connectez le fil de terre de la maison au fil vert du bo tier du ventilateur Figure 8 Utiliser des m thodes approuv es pour toutes les connexions Alimentation provenant de la r sidence UNIT S DEUX VITESSES mod les ES80DH et ES130DH 3 Ventilation continue Pour les ventilateurs deux vitesses c bl s
26. y in place Lift up on the assembly and slide it out of the tabs on the housing Figure 6 Remove the wire compartment cover screw and place the cover in a secure place Figure 7 Plug Hex Nuts Figure 6 NOTE If the fan motor plug is connected to the fan housing receptacle unplug so the blower assembly can be completely removed Humidity Set Point Knob Wire Compartment Cover NOTE Wire compartment configuration will be dependent on model SINGLE SPEED UNITS models ES80SH and ES130SH 2a For proper operation the humidity sensing fan will require a 3 way switch not included Run wiring between the fan and the switch location Make sure you leave enough wiring in each box to make the connections At the switch box connect the black wire from the house to the common terminal of the switch Connect the black wire from the fan to one of the switched terminals on the switch This position will energize the automatic mode and the fan will energize upon a rise in humidity Connect the red wire from the fan to the other switched terminal on the switch This position will activate the Manual On feature and energize the fan Properly connect the ground and neutral if applicable mount the switch and the cover 2b From where you have chosen to access the fan s junction box connect the white wire from the house to the white wire from the fan Connect the wire from the automatic position on the wall switch to the b