Home
Broan 9810WH Instructions / Assembly
Contents
1. 4 Use wire nuts to make connections Insulate all connections with electrical tape SECURING THE HEATER 1 Dress all wiring back to into junction box 2 Locate center holes in housing flange and align with mounting holes in grille 3 Use two provided screws to attach grille to housing OPERATION Turn thermostat fully clockwise to HIGH position Allow heater to run until room is at desired temperature Adjust thermostat as required to maintain desired temperature Turn the thermostat to FULL COUNTERCLOCKWISE position when operation is no longer desired 120vAC GREEN GREEN OR BARE GROUND GROUND FIGURE 4 240vAC GREEN GREEN OR BARE GROUND GROUND O YELLOW RED OR WHITE NO wie Q i O men 0 19 RED CONNECTION O BLACK FIGURE 5 Thermal protector If for any reason temperatures increase beyond normal limits a safety thermal fuse will shut heater off The heater will require servicing by a qualified electrician Check entire installation to determine cause of overheating SERVICE PARTS Key No Part No Description 1 99111432 Grille 2 99360253 Knob 3 52872039 Grille Screw 4 97018465 Heater Assembly 9810WH 97018466 Heater Assembly 9815WH 5 57271000 Thermostat with Mounting Nut 6 33384000 Thermostat Cover 7 33178000 Blower amp Motor 8 98010878 Heat Box 9 35841000 Thermal Fuse 10 99271433 Thermal Protector WARRANTY BROAN NUTONE ONE YEAR LIMITED WARRANTY Broan NuTone warrants to th
2. s wide MOUNTING THE HOUSING Existing Construction 1 Choose heater location Make sure the heater will not be mounted closer than 12 from a vertical surface or 6 from the floor 2 Refer to Figure 2 Make wall cutout next to a wall stud Cutout size 12 s high x 10 s wide with frame 3 Run wiring from circuit breaker or fuse box to heater location 4 Install box connector into wiring entrance hole in housing s junction box 5 Pull wiring through cutout and secure cable to box connector Allow 6 of wiring to make connections 6 Refer to Figure 3 Insert TOP of housing into cutout first so that box connector clears the wall Then insert bottom of housing into cutout The flange must be flush with the wall 7 Use nails or screws to mount one side of housing to wall stud INSTALLATION INSTRUCTIONS READ amp SAVE THESE INSTRUCTIONS NEW CONSTRUCTION B UNIT MOUNTING HOLE TOP AND BOTTOM EXISTING CONSTRUCTION JUNCTION BOX ROUGH IN FRAME WALL STUDS FIGURE 2 FIGURE 3 WIRING CONNECTIONS All wiring must comply with local codes and unit must be properly grounded 1 While making wiring connections support the heater assembly on the bottom of the rough in frame 2 For 120 Volt operation make wiring connections as shown in Figure 4 3 For 240 Volt operation make wiring connections as shown in Figure 5
3. OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties To qualify for warranty service you must a notify Broan NuTone at the address or telephone number below b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date Broan NuTone LLC 926 W State Street Hartford Wisconsin 53027 www broan com 800 558 1711 99044757A DR A INSTRUCCIONES DE INSTALACION Ces jLEA Y CONSERVE ESTAS INSTRUCCIONES Calefactores de pared SERIES 9810WH 9815WH INSTRUCCIONES DE SEGURIDAD _ _ _ _ _ _ _ _ CONSTRUCCI N NUEVA e Lea detenidamente todas las instrucciones y etiquetas del producto antes de ORIFICIO DE MONTAJE comenzar la instalaci n DE LA UNIDAD B PARTE fs PE E SUPERIOR E INFERIOR e El calefactor puede instalarse nicamente en posici n vertical e Instale el calefactor a una altura no menor de 15 cm 6 pulg del piso acabado e No instale el calefactor sobre tinas ni en duchas e Una vez instalado el calefactor debe estar alejado al menos 30 cm 12
4. E INCANDESCENTES FUSIBLES e ae a ge reste FILTROS CONDUCTOS TAPONES DE TECHO O PAREDES Y DEM S ACCESORIOS en Hacor y motor PARA CONDUCTOS Esta garant a no cubre a mantenimiento y servicio normales 8 98010878 Caja del calefactor o b cualesquiera productos o piezas que hayan sido utilizados de forma err nea 9 35841000 Fusible t rmico negligente que hayan causado un accidente o que hayan sido reparados o mantenidos 10 99271433 Protector t rmico inapropiadamente por otras compa as que no sean Broan NuTone instalaci n defectuosa o instalaci n contraria a las instrucciones de instalaci n recomendadas La duraci n de cualquier garant a impl cita se limita a un per odo de un a o como se especifica en la garant a expresa Algunos estados no permiten limitaciones en cuanto al tiempo de vencimiento de una garant a impl cita por lo que la limitaci n antes mencionada puede no aplicarse a usted LA OBLIGACI N DE BROAN NUTONE DE REPARAR O REEMPLAZAR SIGUIENDO EL CRITERIO DE BROAN NUTONE DEBER SER EL NICO Y EXCLUSIVO RECURSO LEGAL DEL COMPRADOR BAJO ESTA GARANT A BROAN NUTONE NO SER RESPONSABLE POR DANOS INCIDENTALES CONSECUENTES O POR DA OS ESPECIALES QUE SURJAN A RA Z DEL USO O DESEMPE O DEL PRODUCTO Algunos estados no permiten la exclusi n o limitaci n de da os incidentales o consecuentes por lo que la limitaci n antes mencionada puede no aplicarse a usted Esta garant a le proporciona derechos legal
5. deseada Para detener el FIGURA 5 funcionamiento del termostato g relo a la posici n TOTALMENTE EN SENTIDO CONTRARIO A LAS AGUJAS DEL RELOJ Protector t rmico Si por cualquier motivo la temperatura sobrepasa los l mites normales un fusible t rmico de seguridad apagar el calefactor En ese caso un electricista calificado deber examinar el calefactor Inspeccione la instalaci n completa para determinar la causa del sobrecalentamiento 240 V CA 60 Hz GARANTIA PIEZAS DE REPUESTO GARANT A BROAN NUTONE LIMITADA POR UN A O Broan NuTone garantiza al consumidor comprador original de sus productos que dichos Clave n Pieza n Descripci n productos carecer n de defectos en materiales o en mano de obra por un per odo de un a o a partir de la fecha original de compra NO EXISTEN OTRAS GARANTIAS 1 99111432 Rejilla EXPLICITAS O IMPLICITAS INCLUYENDO ENTRE OTRAS GARANT AS IMPL CITAS 2 99360253 Perilla DE COMERCIALIZACI N O APTITUD PARA UN PROPOSITO PARTICULAR 3 52872039 Tornillo de la rejilla Durante el per odo de un a o y a su propio criterio Broan NuTone reparar o 4 97018465 Montaje del calefactor 9810WH reemplazar sin costo alguno cualquier producto o pieza que se encuentre defectuosa 97018466 Montaje del calefactor 9815WH bajo condiciones normales de servicio y uso 5 57271000 Termostato con tuerca de montaje LA PRESENTE GARANT A NO CUBRE LOS TUBOS FLUORESCENTES NI SUS 3 ARRANCADORES BOMBILLAS DE HAL GENO
6. BROAN Wall Heaters 9810WH 9815WH SERIES SAFETY INSTRUCTIONS e Carefully read all instructions and product labels before beginning installation e Only mount the heater in a vertical position Mount the heater at least 6 above the finished floor e Do not mount the heater over a bathtub or in a shower stall enclosure e When mounted the heater should not be closer than 12 to an adjacent wall e Do not block the wall heater i e by mounting under a towel rack behind a door etc ELECTRICAL SPECIFICATIONS NOTE See wiring label on heater housing The heater may be wired for either 120V or 240V operation and requires a separate circuit UNIT DIMENSIONS Housing 12 2 high x 101 2 wide x 3 s deep Grille 14 4 high x 11 wide x 1 deep Wall Cutout 12 s high x 10 s wide MOUNTING THE HOUSING New Construction Refer to Figure 1 1 Choose heater location Make sure the heater will not be mounted closer than 12 from a vertical surface or 6 from the floor 2 Using nails or screws mount one side of housing to wall stud The flange must be flush to the stud 3 Run wiring from circuit breaker or fuse box to heater location 4 Install box connector into wiring entrance hole in housing s junction box 5 Pull wiring through entrance hole and secure cable to box connector Allow 6 of wiring to make connections 6 Finished wall opening should be 12 s high x 10
7. ables por el orificio de entrada y fije el cable al conector de caja Deje unos 15 cm 6 pulg de cable para poder hacer las conexiones S ii DELA Y IZE 4 5nd g 31 6 La abertura de pared terminada debe tener las siguientes dimensiones PARED 32 cm 12 pulg de alto x 27 cm 10 pulg de ancho ARMAZON DE MONTAJE EN PARED MONTANTES MONTAJE DE LA CUBIERTA PEPARED FIGURA 2 Construcci n existente 1 Elija la posici n del calefactor Aseg rese de que el sitio donde se instalar el calefactor est alejado al menos 30 cm 12 pulg de una superficie vertical y a una altura no menor de 15 cm 6 pulg del piso 2 Vea la figura 2 Haga el recorte de la pared al lado de un montante de la pared Tama o del recorte 32 cm 12 pulg de alto x 27 cm 10 pulg de ancho con el armaz n 3 Tienda los cables del interruptor autom tico de circuitos o de la caja de fusibles al sitio de instalaci n del calefactor 4 Instale el conector de la caja en el orificio de entrada del cableado de la caja de conexiones de la cubierta 5 Haga pasar los cables por el recorte y fije el cable al conector de caja Deje unos 15 cm 6 pulg de cable para poder hacer las conexiones CAJA DE 6 Vea la figura 3 Inserte primero la PARTE SUPERIOR de la cubierta en el recorte de manera que MONTAJE el conector puede pasar por la pared Luego inserte la parte inferior de la cubierta en el recorte EN PARED La b
8. e original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan NuTone will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS TUBES HALOGEN AND INCANDESCENT BULBS FUSES FILTERS DUCTS ROOF CAPS WALL CAPS AND OTHER ACCESSORIES FOR DUCTING This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan NuTone faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN NUTONE S OBLIGATION TO REPAIR OR REPLACE AT BROAN NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF
9. es espec ficos y usted puede tambi n tener otros derechos los cuales var an de estado a estado Esta garant a reemplaza todas las garant as anteriores Para calificar para la garant a de servicio usted debe a notificar a Broan NuTone al domicilio o al n mero de tel fono que se menciona abajo b dar el n mero del modelo y la identificaci n de la pieza y c describir la naturaleza de cualquier defecto en el producto o la pieza En el momento de solicitar servicio cubierto por la garant a usted debe de presentar un comprobante con la fecha original de compra Broan NuTone LLC 926 W State Street Hartford Wisconsin 53027 www broan com 800 558 1711 99044757A
10. pulg de una pared adyacente e No obstruya el calefactor por ejemplo evite instalarlo debajo de barras de toallas detr s de puertas etc ESPECIFICACIONES EL CTRICAS NOTA Consulte la etiqueta de cableado que se encuentra en la cubierta del calefactor El calefactor puede conectarse para funcionar con 120 V o con 240 V y requiere un circuito separado DIMENSIONES DE LA UNIDAD A FIGURA 1 Cubierta 31 7 cm 12 pulg de alto x 26 7 cm 10 pulg de ancho x 8 6 cm CONSTRUCCI N 3 pulg de profundidad EXISTENTE Rejilla 37 5 cm 14 pulg de alto x 29 4 cm 11 6 pulg de ancho x 2 5 cm 1 pulg de profundidad Recorte de la pared 32 cm 12 pulg de alto x 27 cm 10 pulg de ancho CAJA DE CONEXIONES MONTAJE DE LA CUBIERTA HONTE BEL Construcci n nueva SALETAST OR Vea la figura 1 1 Elija la posici n del calefactor Aseg rese de que el sitio donde se instalar el calefactor est alejado al menos 30 cm 12 pulg de una superficie vertical y a una altura no menor de 15 cm 6 pulg del piso 2 Fije un lado de la cubierta al montante de la pared con clavos o tornillos La brida tiene que estar al ras con el montante 3 Tienda los cables del interruptor autom tico de circuitos o de la caja de fusibles hacia el sitio de instalaci n del calefactor 4 Instale el conector de caja en el orificio de entrada del cableado de la caja de conexiones de la cubierta 5 Haga pasar los c
11. rida tiene que estar al ras con la pared 7 Fije un lado de la cubierta al montante de la pared con clavos o tornillos CONEXIONES DE LOS CABLES t20Vca Todo el cableado debe cumplir con los c digos locales y la unidad CABLE DE CABLE DE TIERRA debe estar puesta a tierra correctamente TIERRA VERDE VERDE O DESNUDO 1 Al hacer las conexiones el ctricas apoye el montaje del calefactor en la parte inferior de la armaz n empotrada 2 Para el funcionamiento con 120 V haga las conexiones indicadas BLANCO en la figura 4 3 Para el funcionamiento con 240 V haga las conexiones indicadas en la figura 5 4 Haga las conexiones con tuercas de alambre A sle todas las conexiones con cinta el ctrica FIJACI N DEL CALEFACTOR 1 Empuje y arregle todos los cables de vuelta hacia la caja q o gt e A gt FIGURA 4 60 Hz 240 V CA A CABLE DE TIERRA de conexiones MEERA VERDE VERDE O DESNUDO 2 Ubique los orificios centrales en la brida de la cubierta y alin elos O con los orificios de montaje de la rejilla AMARILLO ROJO O BLANCO 3 Sujete la rejilla a la cubierta con los dos tornillos suministrados sanco 4 SIN CONEXION FUNCIONAMIENTO 0 l ROJO SIN CONEXION Gire el termostato completamente en sentido de las agujas del reloj a la posici n alta HIGH D jelo funcionar hasta que la habitaci n C necro llegue a la temperatura deseada Ajuste el termostato de ser necesario para mantener la temperatura
Download Pdf Manuals
Related Search
Related Contents
Operating instructions Door Station Stainless Steel - Page 1 La signification humaine du suicide Genius LuxeMate 635 Laser Harbor Freight Tools 1/4 in. 2.4 Amp Trim Router Product manual Dean & Deluca BK1814 User's Manual HP LaserJet CM4730 All-In Cables Direct B6-505B networking cable HTS8160B/12 Philips SoundBar HD home theater Bedienungsanleitung Amici X6 Espressomaschine Copyright © All rights reserved.
Failed to retrieve file