Home
NuTone LPN80 Instructions / Assembly
Contents
1. Page 7 Operation To Operate Fan Use an ON OFF switch or speed control to operate this ventilator WARNING Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Cleaning and Maintenance To Clean For quiet and efficient operation long life and attractive appearance remove Grille and vacuum interior of unit with a dusting brush attachment The Motor is permanently lubricated and never needs oiling If the motor bearings are making excessive or unusual noises replace the Motor NuTone LPN80 Installation Guide Troubleshooting Symptom The fan does not run e Check for an open fuse or circuit breaker in the building s service panel e Check that the plug in connection for the Motor is seated firmly in place e Check that the Blower Wheel spins freely Symptom The fan runs erratically e Check that the Blower Wheel is firmly attached to the Motor shaft and both spin freely Symptom The fan seems noisy e Check that the back draft damper in the fan s Duct Connector
2. Instalacion sencilla 2012 Broan NuTone LLC indice Advertencias y precauciones Instalaci n tipica Instalaci n Funcionamiento Limpieza y mantenimiento Resoluci n de problemas Piezas de servicio Garant a 18 18 19 22 23 23 23 24 24 Pagina 18 ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIOS DESCARGAS ELECTRICAS O LESIONES PERSONALES SIGA LAS SIGUIENTES PRECAUCIONES 1 Use la unidad s lo de la manera indicada por el fabricante Si tiene preguntas comuniquese con el fabricante a la direcci n o al n mero telef nico que se incluye en la garant a 2 Antes de dar servicio a la unidad o de limpiarla interrumpa el suministro el ctrico en el panel de servicio y bloquee los medios de desconexi n del servicio para evitar que la electricidad se reanude accidentalmente Cuando no sea posible bloquear los medios de desconexi n del servicio fije firmemente una se al de advertencia como una etiqueta en un lugar visible del panel de servicio 3 Una o m s personas calificadas deben realizar el trabajo de instalaci n y el cableado el ctrico de acuerdo con todos los c digos y normas correspondientes incluidos los c digos y las normas de construcci n espec ficos de protecci n contra ince
3. Page 15 Fonctionnement Pour actionner le ventilateur Utilisez un interrupteur marche arr t ou une commande de vitesse pour actionner le ventilateur AVERTISSEMENT 42 avant de proc der l entretien ou au nettoyage de l appareil coupez l alimentation du panneau lectrique et verrouillez l interrupteur principal afin d emp cher que le courant ne soit accidentellement r tabli S il est impossible de verrouiller l interrupteur principal fixez solidement un message d avertissement par exemple une tiquette sur le panneau lectrique Nettoyage et entretien Pour nettoyer Pour un fonctionnement silencieux et efficace ainsi qu une durabilit et une apparence sup rieures enlevez la grille et nettoyez l int rieur de l appareil avec un aspirateur muni d une brosse pousseter Le moteur est lubrifi en permanence et n a pas besoin d tre huil Si les roulements du moteur sont anormalement bruyants remplacez le moteur NuTone LPN80 Guide d installation D pannage Sympt me Le ventilateur ne d marre pas e V rifiez que le disjoncteur ou le fusible ne sont pas coup s dans le panneau lectrique de I difice e V rifiez que la fiche du moteur est bien branch e et fermement appuy e e V rifiez que la roue ailettes tourne librement Sympt me Le ventilateur tourne de mani re in gale
4. Broan NuTone LLC 926 W State Street Hartford Wisconsin 53027 www nutone com 888 336 3948 Order replacement parts by Part No not by Key No Broan NuTone Canada Inc 1140 Tristar Drive Mississauga Ontario L5T 1H9 www nutone ca 877 896 1119 79040167A Nulone LIRE CES DIRECTIVES ET LES CONSERVER Installateur veuillez laisser ce guide au propri taire Enregistrez votre produit en ligne www broan com register Installation facile O 2012 Broan NuTone LLC LPN80 Ventilateur profil surbaiss GUIDE D INSTALLATION Table des mati res Avertissements et mises en garde 10 Installation type 10 Installation 11 14 Fonctionnement 15 Nettoyage et entretien 15 D pannage 15 Pi ces de rechange 16 Garantie 16 Page 10 AVERTISSEMENT OBSERVEZ LES DIRECTIVES CI DESSOUS AFIN DE R DUIRE LES RISQUES D INCENDIE DE CHOC ELECTRIQUE OU DE BLESSURES CORPORELLES 1 N utilisez cet appareil que de la mani re pr vue par le fabricant Si vous avez des questions communiquez avec le fabricant l adresse ou au num ro de t l phone indiqu s dans la g
5. Funcionamiento Para accionar el ventilador Para accionar este ventilador utilice el interruptor de encendido apagado o el control de velocidad ADVERTENCIA antes de realizar el servicio o de limpiar la unidad corte el suministro el ctrico en el panel de servicio y bloquee el servicio desconectando los medios que evitan que se conecte la energ a en forma accidental Cuando no se puedan bloquear los medios que desconectan el servicio coloque un dispositivo de alarma importante como por ejemplo una etiqueta en el panel de servicio Limpieza y mantenimiento Para limpiar Para lograr un funcionamiento silencioso y eficiente larga vida y una apariencia atractiva retire la rejilla y aspire el interior de la unidad con el accesorio del cepillo para sacudir polvo El motor est permanentemente lubricado y nunca necesitar ponerle aceite Si los cojinetes del motor hacen ruidos excesivos o inusuales reemplace el motor NuTone LPN80 Gu a de instalaci n Resoluci n de problemas S ntoma el ventilador no funciona e Compruebe si hay un fusible o interruptor de circuitos abierto en el panel de servicio del edificio Compruebe que la conexi n enchufable del motor est firmemente asentada en su lugar Compruebe que la rueda del ventilador gira libremente S ntoma el ventilador funciona err ticamente e Compruebe que la rueda del ventilador est firmemente acoplada al eje del motor y que ambas giren li
6. Cuando se instale en una pared o un cielo raso con pendiente el conector del conducto debe apuntar hacia arriba 3 Para evitar da os a los cojinetes del motor y rotores ruidosos o desbalanceados mantenga la unidad de potencia protegida contra rociados de yeso polvos de construcci n etc 4 Lea la etiqueta de especificaciones del producto para ver informaci n y requisitos adicionales NO USAR EL PRODUCTO EN UN REA DE COCINA No instale el equipo sobre o dentro de esta rea Equipo de cocina Piso TAPA DE TECHO con CABLE R Mantenga e Se fija a vigas 2 x 4 pulg o a EL CTRICO Y cortos los montantes de pared o viguetas de REN Se cielo raso de mayor tama o Selle las SEK conductos separaciones alrededor de la cubierta CONDUCTO REDONDO Selle con CL TAPA DE Se compra por separado Viguetas Viguetas I Vigas cinta las uniones REDONDOS de los conductos PARED con regulador de tiro integrado SE MUESTRA LA INSTALACION EN EL CIELO RASO Pagina 19 NuTone LPN80 Gu a de instalaci n Instalaci n Herramientas necesarias Materiales necesarios e Destornillador el ctrico con punta Phillips e Se recomienda el conducto met lico redondo de 4 pulg 10 2 cm e Destornillador Phillips para obtener el mejor desempe o Es aceptable usar otros conductos e Desforrador de aislamiento de cables pero se puede afectar el desempe o Tapa de techo o tapa de p
7. e V rifiez que la roue ailettes est solidement fix e l arbre du moteur et que les deux tournent librement Sympt me Le ventilateur semble bruyant e V rifiez que le clapet l arri re du raccord de conduit pivote librement Les vis utilis es pour fixer le conduit au raccord peuvent emp cher le clapet de s ouvrir correctement e V rifiez que le clapet antirefoulement du capuchon mural ou de toit pivote librement Ces clapets sont parfois peints par erreur ce qui les emp che de s ouvrir ou obstru s par des d bris d oiseaux ou d insectes Page 16 Pi ces de rechange N de rep re N de pi ce Description 77001277 79140014 77001282 Ensemble de raccord de conduit Ressort de grille 2 inclus Ensemble de grille comprend 2 ressorts 77001297 Condensateur 77001298 79110158 Ensemble de panneau de c blage R ducteur de 10 2 cm 7 6 cm 4 po 3 po Tige de suspension Plaque ouverture pr amorc e Ensemble de ventilateur 77001299 77001300 77001279 Veuillez commander les pi ces par N de pi ce et non par N de rep re NuTone LPN80 Guide d installation Garantie GARANTIE LIMIT E D UN AN BROAN NUTONE Broan NuTone garantit l acheteur original que les produits vendus en vertu de la pr sente sont libres de tout vice de mat riau ou de fabrication pour une p riode d un an compter de la date d achat originale CETTE GARANTIE NE COMPORTE AUCUNE AUTRE GARANT
8. 4 Ducting S on EY 4 to 3 Reducer provided Tape i Insert tab into slot in housing Page 5 NuTone LPN80 Installation Guide Installation Connect Wires e Run 120VAC electrical wiring to the installation location e Use proper UL approved connectors to secure wiring to the Knockout Plate e Connect wires as shown in wiring diagram Attach cable clamp to Knockout Plate Knockout Plate may be oriented as desired ON OFF SWITCH i 120 VAC WHT EINE IN GRD GRD o AR J SWITCH BOX UNIT DNI GROUND green or bare WHITE RECEPTACLE ON OFF SWITCH 20000 gt purchase separately SWITCH BOX KNOGKOUT PLATE 120 VAC LINE IN Page 6 NuTone LPN80 Installation Guide Installation 5 Insert Mask and Finish Wall or Ceiling Mask protects unit during construction Remove before installing Grille Squeeze grille springs and insert into slots in housing EN D 4 ji A D
9. du ruban MURAL avec s par ment conduit clapet int gr INSTALLATION DANS UN PLAFOND Page 11 N ulone LPN80 Guide d installation Installation Outils requis Mat riel requis e Tournevis lectrique pointe cruciforme e Conduit rond de 10 2 cm 4 po recommand pour un meilleur e Tournevis cruciforme rendement D autres types de conduits sont acceptables mais e Pince d nuder les fils peuvent affecter le rendement e Pince coupante Capuchon de toit ou mural clapet int gr recommand Ruban pour sceller les raccords du conduit Vis cloisons s ches vis t le ou suspendre Fils lectriques et fournitures conformes au code local 1 Sortir de l emballage de l emballage D tacher le masque y Voir tape 5 y Page 12 N ulone LPN80 Guide d installation Installation 2 Installer dans le mur ou le plafond Suspendre en 3 points y Vis travers le bo tier du c t oppos 8 D 332 Ss gt 7 N 7 a NX gr N 7 DS S Serrer la vis dans le Y EQ 4 boitier pour assurer le montage Plafond Conduit de o cm 3 po D Ml de 10 2 cm 7 6 cm Stor 3 po fourni Ruban Ins rer la languette dans la fente du bo tier LB NuTone LPN80 Guide d installation Page 13 Installation Connecte
10. est branch sur un circuit de d rivation prot g par un disjoncteur de fuite la terre 8 Cet appareil doit tre reli une mise la terre ISOLANT Peut tre plac sur le bo tier de NuTone LPN80 Guide d installation ATTENTION 1 Pour ventilation g n rale uniquement N utilisez pas cet appareil pour vacuer des mati res ou des vapeurs dangereuses ou explosives 2 Lorsque install dans un mur ou un plafond en pente le raccord du conduit doit tre tourn vers le haut 3 Pour viter d endommager les roulements de moteur de d s quilibrer les pales ou de les rendre bruyantes d barrassez l appareil de la poussi re de pl tre de construction etc 4 Veuillez lire l tiquette de sp cifications du produit pour obtenir plus de renseignements notamment sur les exigences NE PAS INSTALLER DANS UNE ZONE DE CUISSON Ne pas installer au dessus ou l int rieur de cette zone 45 Appareil de cuisson Plancher CAPUCHON Instal lation type ventilateur et autour DE TOIT j avec clapet BOITIER DE int gr e Se fixe aux montants de 2 po x 4 po VENTILATEUR int gr ou plus des murs ou aux solives du Z plafond CABLE CEs Utilisez des DALIMENTATION SSX conduits les x PS plus courts S25 P possible Scellez l cart NT Y autour du bo tier lt lt gt Solives Solives en Fermes GONERIT REND Scellez les CAPUCHON S joints avec Vendu
11. IE EXPRESSE OU TACITE Y COMPRIS MAIS SANS S Y LIMITER LES GARANTIES TACITES DE VALEUR MARCHANDE OU DADAPTATION A UN USAGE PARTICULIER Durant cette p riode d un an Broan NuTone r parera ou remplacera gratuitement a sa discr tion tout produit ou toute pi ce jug s d fectueux dans des conditions normales d utilisation CETTE GARANTIE NE SAPPLIQUE PAS AUX TUBES FLUORESCENTS ET AUX DEMARREURS NI AUX AMPOULES HALOGENES OU INCANDESCENTES FUSIBLES FILTRES CONDUITS CAPUCHONS DE TOIT CAPUCHONS MURAUX ET AUTRES ACCESSOIRES POUR CONDUITS Cette garantie ne couvre pas a les frais d entretien ou de service normaux ni b tout produit ou toute pi ce soumis un abus une n gligence un accident un entretien ou une r paration inad quats autres que ceux effectu s par Broan NuTone une mauvaise installation ou une installation contraire aux instructions recommand es La dur e de toute garantie tacite est limit e la p riode d un an stipul e pour la garantie expresse Certains territoires ou provinces interdisant de limiter la dur e d une garantie tacite la limitation ci dessus peut ne pas s appliquer votre situation LOBLIGATION POUR BROAN NUTONE DE REPARER OU DE REMPLACER LE PRODUIT A SA DISCRETION CONSTITUE LE SEUL RECOURS DE LACHETEUR EN VERTU DE LA PRESENTE GARANTIE BROAN NUTONE NE PEUT ETRE TENUE RESPONSABLE DES DOMMAGES INDIRECTS OU CONSECUTIFS NI DES DOMMAGES INTERETS PARTICULIERS DECOULANT DE LUTILI
12. N A COOKING AREA Do not install above or inside this area Cooking Equipment Floor ROOF CAP with built in wall studs or ceiling joists ca FAN gt lt HOUSING POWER Keep duct CABLE runs short gt lt Joists I Joists Trusses Seal gaps around 7 Housing ROUND Seal duct Purchase joints with ROUND Y WAEA separately tape ELBOWS qi uilt in amper CEILING INSTALLATION SHOWN Page 3 NuTone LPN80 Installation Guide Installation Tools needed Materials needed e Power screwdriver with a Phillips bit e 4 round metal ducting recommended for best performance e Phillips screwdriver Use of other ducting is acceptable but may impact performance e Wire insulation stripper Roof cap or wall cap built in damper recommended e Wire cutter Tape to seal duct connections Drywall screws sheet metal screws or wire Electrical wiring and supplies per local code requirements 1 Remove from Packaging lt s Punch out Mask from packaging See Step 5 Page 4 N ulone LPN80 Installation Guide Installation 2 Install in Wall or Ceiling E Wire _ 3 places 2 Screw through housing on opposite side Al 2 N Y NX QS 4 L7TAX Tighten Screw into housing to secure mounting 3 Install Ducting 3 Ducting 3 2 Y Tape
13. Nulone READ AND SAVE THESE INSTRUCTIONS Installer leave this guide with homeowner Register your product online at www broan com register Easy installation O 2012 Broan NuTone LLC LPN80 Lo Profile Ventilation Fan INSTALLATION GUIDE Table of Contents Warnings and Cautions Typical Installation Installation Operation Cleaning and Maintenance Troubleshooting Service Parts Warranty E O Page 2 WARNING amp TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty 2 Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 3 Installation work and electrical wiring must be done by a qualified person s in accordance wit
14. SATION OU DU RENDEMENT DU PRODUIT Certains territoires ou provinces ne permettant pas la limitation ou l exclusion des dommages indirects ou cons cutifs la limitation ci dessus peut ne pas s appliquer votre situation La pr sente garantie vous conf re des droits sp cifiques reconnus par la loi D autres droits pourraient galement vous tre accord s selon la l gislation locale en vigueur La pr sente garantie remplace toutes les autres garanties pr c dentes Pour vous pr valoir de cette garantie vous devez a aviser Broan NuTone l adresse ou au num ro de t l phone indiqu s ci dessous b donner le num ro de mod le du produit et le num ro d identification de la pi ce et c d crire la nature de la d fectuosit du produit ou de la pi ce Lors de votre demande de garantie vous devez pr senter une preuve de la date d achat originale Broan NuTone LLC 926 W State Street Hartford Wisconsin 53027 www nutone com 888 336 3948 Broan NuTone Canada Inc 1140 Tristar Drive Mississauga Ontario L5T 1H9 www nutone ca 877 896 1119 79040167A Nulone LEA Y CONSERVE ESTAS INSTRUCCIONES Aviso al instalador deje esta gu a con el due o de la casa Registre su producto en l nea en www broan com register LPN80 Ventilador de bajo perfil GUIA DE INSTALACION
15. arantie 2 Avantde proc der l entretienouaunettoyage del appareil coupez l alimentation du panneau lectrique et verrouillez l interrupteur principal afin d emp cher que le courant ne soit accidentellement r tabli S il est impossible de verrouiller l interrupteur principal fixez solidement un message d avertissement par exemple une tiquette sur le panneau lectrique 3 La pose de l appareil et les travaux d lectricit doivent tre effectu s par des personnes qualifi es conform ment la r glementation en vigueur notamment les normes de la construction ayant trait la protection contre les incendies 4 Pour viter les refoulements l apport d air doit tre suffisant pour br ler les gaz produits par les appareils combustion et les vacuer dans le conduit de fum e chemin e Respectez les directives du fabricant de l appareil de chauffage et les normes de s curit notamment celles publi es par la National Fire Protection Association NFPA l American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et les codes des autorit s locales 5 Veillez ne pas endommager le c blage lectrique ou d autres quipements non apparents lors de la d coupe ou du per age du mur ou du plafond 6 Les ventilateurs canalis s doivent toujours rejeter lair l ext rieur 7 Cet appareil peut tre install au dessus d une baignoire ou d une douche uniquement dans le plafond s il
16. ared se recomienda el regulador integrado Cinta para sellar las conexiones de los conductos e Cortador de cables Tornillos para placa de yeso para chapa met lica o cable Cableado el ctrico y suministros de acuerdo con los requisitos del c digo local 1 Retire del empaque lt s Perfore la cubierta del empaque Vea el paso 5 Pagina 20 NuTone LPN80 Gu a de instalaci n Instalaci n 2 Instale en la pared o el cielo raso Cable 3 lugares A ARRIBA y 6 OBIEN Tornillo a trav s de la cubierta al lado opuesto JEO g as NN S Apriete el tornillo en la caja para asegurar el montaje Cielo raso 3 Instale los conductos Conducto de 3 pulg 7 6 cm 2 a Cinta Conducto Se incluye el de 4 pulg reductor de 10 2 cm 4 a 3 pulg 10 2 a de cm Cinta ES a E iia Inserte la pesta a en la ranura de la cubierta KZ SB Pagina 21 N ulone LPN80 Gu a de instalaci n Instalaci n Conecte los cables e Coloque el cable el ctrico de 120 VCA hasta el lugar de la instalaci n e Use conectores adecuados y aprobados por UL para asegurar el cableado a la placa de agujero ciego e Conecte los cables tal como se ilustra en el diagrama de cableado Conecte los cables Fije la abrazadera d
17. bremente S ntoma el ventilador parece ruidoso Compruebe que el regulador de contratiro en el conector de conductos del ventilador pivotee libremente Los tornillos empleados para fijar el conducto al conector podr an impedir que se abra el regulador Compruebe que el regulador de contratiro en la pared o tapa de techo pivotee libremente A veces a estos reguladores se les tapa con pintura por error o est n obstruidos por desechos de aves e insectos Pagina 24 N ulone LPN80 Gu a de instalaci n Piezas de servicio Garant a 6 GARANT A LIMITADA DE UN A O DE BROAN NUTONE Broan NuTone garantiza al consumidor comprador original de sus productos que dichos productos estar n libres de defectos en materiales o mano de obra durante un per odo de un a o a partir de la fecha de compra original NO EXISTEN OTRAS GARANT AS EXPLICITAS O IMPL CITAS INCLUYENDO ENTRE OTRAS GARANT AS IMPL CITAS DE COMERCIALIZACI N O APTITUD PARA UN PROPOSITO PARTICULAR Durante este per odo de un a o Broan NuTone a su criterio reparar o reemplazar sin cargo alguno cualquier pieza o producto que se encuentre defectuoso bajo condiciones normales de uso y servicio LA PRESENTE GARANT A NO CUBRE TUBOS O ARRANCADORES DE LAMPARAS FLUORESCENTES BOMBILLAS HALOGENAS E INCANDESCENTES FUSIBLES FILTROS CONDUCTOS TAPAS DE TECHO O DE PARED Y DEMAS ACCESORIOS DE CANALIZACION Esta garant a no cubre a mantenimiento y servicio normales
18. cho al servicio de la garant a usted debe a 77001298 Conjunto del panel de cableado notificar a Broan NuTone a la direcci n y n mero de tel fono que aparecen abajo b proporcionar el n mero de modelo y la identificaci n de la pieza y c describir la naturaleza de cualquier defecto en el producto o pieza En el momento de solicitar el servicio cubierto por la garant a debe presentar un comprobante de la fecha original de compra Broan NuTone LLC 926 W State Street Hartford Wisconsin 53027 www nutone com 888 336 3948 79110158 Reductor de 4 a 3 pulg 10 2 a 7 6 cm 77001299 Barra de suspensi n 77001300 Placa de agujero ciego 77001279 Conjunto del ventilador 0 J O O1 ND D Pida las piezas por numero de pieza no por numero de clave Broan NuTone Canada Inc 1140 Tristar Drive Mississauga Ontario L5T 1H9 www nutone ca 877 896 1119 79040167A
19. el cable a la placa de agujero ciego La placa de agujero ciego se puede orientar como se desee E l l INTERRUPTOR DE ENCENDIDO APAGADO BLANCO NEGRO l LINEA DE ENTRADA BLANCO l DE 120 VCA TIERRA TIERRA l e J CAJA DEL INTERRUPTOR UNIDAD NEGRO TIERRA verde o desnudo BLANCO RECEPT CULO INTERRUPTOR DE ENCENDIDO APAGADO CAJA DEL 2000 gt se compra por separado INTERRUPTOR PLACA DE D AGUJERO CIEGO L NEA DE ENTRADA DE 120 VCA Pagina 22 N ulone LPN80 Gu a de instalaci n Instalaci n 5 Inserte la cubierta protectora y d acabado a la pared o al cielo raso La cubierta protectora protege la unidad durante la construcci n Qu tela antes de instalar la rejilla Comprima los resortes de la rejilla e inserte en las ranuras de la cubierta Pagina 23
20. h all applicable codes and standards including fire rated construction codes and standards 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors 7 Acceptable for use over a tub or shower in the ceiling only when connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit 8 This unit must be grounded O Typical Installation INSULATION Place around and over Fan Housing e Attaches to 2 x 4 or greater NuTone LPN80 Installation Guide CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 When installed in a wall or slope ceiling the duct connector must point up 3 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 4 Please read specification label on product for further information and requirements NOT FOR USE I
21. ndios 4 Es necesario suficiente aire para que se lleve a cabo una combusti n y una extracci n adecuadas de los gases a trav s del tubo de humos chimenea del equipo quemador de combustible con el fin de evitar el contratiro Siga las directrices y las normas de seguridad del fabricante del equipo de calefacci n como las publicadas por la Asociaci n Nacional de Protecci n contra Incendios National Fire Protection Association NFPA la Sociedad Americana de Ingenieros de Calefacci n Refrigeraci n y Aire Acondicionado American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE y las autoridades normativas locales 5 Al cortar o perforar a trav s de la pared o del techo tenga cuidado de no da ar el cableado el ctrico ni otros servicios ocultos 6 Los ventiladores en conductos siempre deben ventearse hacia el exterior 7 Esta unidad puede instalarse sobre una tina o ducha en el cielo raso solamente siempre que se conecte a un GFCI interruptor accionado por p rdida de conexi n a tierra en un circuito de derivaci n protegido 8 Esta unidad debe estar conectada a tierra Instalaci n t pica NuTone AISLAMIENTO Coloque alrededor y sobre la cubierta del ventilador CUBIERTA DEL VENTILADOR LPN80 Gu a de instalaci n PRECAUCI N 1 S lo para usarse como medio de ventilaci n general No debe Usarse para la extracci n de materiales o vapores peligrosos o explosivos 2
22. ni b ning n producto o piezas que se hayan sometido a uso inadecuado negligencia accidente mantenimiento o reparaci n inadecuada no hecha por Broan NuTone instalaci n incorrecta o instalaci n en contra de las instrucciones de instalaci n recomendadas La duraci n de cualquier garant a impl cita se limita a un per odo de un a o como se especifica en la garant a expresa Algunos estados no permiten limitaciones en cuanto al tiempo de vencimiento de una garant a impl cita por lo que la limitaci n antes mencionada podr a no aplicarse a usted LA OBLIGACI N DE BROAN NUTONE DE REPARAR O REEMPLAZAR A CRITERIO DE BROAN NUTONE SERA EL UNICO Y EXCLUSIVO RECURSO DEL COMPRADOR BAJO ESTA GARANT A BROAN NUTONE NO SER RESPONSABLE POR DA OS INCIDENTALES RESULTANTES O ESPECIALES QUE SURJAN DEL USO O DESEMPENO DEL PRODUCTO O EN RELACI N CON ESTE Algunos estados no permiten la exclusi n o limitaci n de da os incidentales o resultantes por lo Clave N Pieza N Descripci n que la limitaci n antes mencionada podr a no aplicarse a usted Esta garant a le otorga derechos legales espec ficos y usted podr a tener otros derechos que var an de un estado a otro Esta garant a sustituye todas las garant as anteriores 77001277 Conjunto del conector de conductos 79140014 Resorte de la rejilla se incluyen 2 77001282 Conjunto de la rejilla incluye 2 resortes de la rejilla 77001297 Capacitor Para tener dere
23. pivots freely Screws used to attach the ducting to the Duct Connector may be preventing the damper from opening e Check that the back draft damper in the wall or roof cap pivots freely These dampers are sometimes mistakenly painted shut or obstructed by bird and insect debris Page 8 NuTone LPN80 Installation Guide Service Parts Warranty 6 BROAN NUTONE ONE YEAR LIMITED WARRANTY Broan NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan NuTone will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS TUBES HALOGEN AND INCANDESCENT BULBS FUSES FILTERS DUCTS ROOF CAPS WALL CAPS AND OTHER ACCESSORIES FOR DUCTING This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan NuTone faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is limited to
24. r les fils e Acheminer un fil lectrique de 120 VCA jusqu au site d installation e Utiliser les connecteurs homologu s UL pour fixer le fil ouverture pr amorc e fournie e Connecter les fils tel qu illustr dans le sch ma de c blage Connecter les fils Fixer la pince du c ble l ouverture pr amorc e La plaque peut tre orient e dans le sens voulu BO TE D INTERRUPTEUR APPAREIL NOIR BLANC FIL DE TERRE vert ou fil nu PRISE INTERRUPTEUR BO TE COS vendu s par ment D INTERRUPTEUR OUVERTURE PR AMORC E ALIMENTATION 120 VCA NuTone LPN80 Guide d installation Page 14 Installation 5 Ins rer le masque et finir le mur ou le plafond Ce masque prot ge l appareil durant la construction Le retirer avant d installer la grille Pincer les ressorts de la grille et les ins rer dans les fentes du bo tier E D y V
25. the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN NUTONE S OBLIGATION TO REPAIR OR REPLACE AT BROAN NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you PM This warranty gives you specific legal rights and you may also Key No PartNo Description have other rights which vary from state to state This warranty 77001277 Duct Connector Assembly supersedes all prior warranties 79140014 Grille Spring 2 included 77001282 Grille Assembly includes 2 grille springs 77001297 Capacitor 77001298 Wire Panel Assembly To qualify for warranty service you must a notify Broan NuTone at the address or telephone number below b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date 79110158 4 to 3 Reducer 77001299 Hanger Bar 77001300 Knockout Plate 77001279 Blower Assembly J O O1 ND D
Download Pdf Manuals
Related Search
Related Contents
HP F325 Setup Guide Instrucciones de operación PT EK Water Blocks EK-UNI Holder 50/70 Dell PowerConnect W-Airwave 8.0 User's Manual User manual v1.1 - Online database 2 - INCOE® Corporation - Des Moines Radio Amateurs Association Parasitismo associado à traça-da-uva, Lobesia botrana (Dennis Gardena 8899-20 Copyright © All rights reserved.
Failed to retrieve file