Broan 128 Installation Guide
Contents
1. ruidosos y o desequilibrados mantenga la unidad de energ a alejada de roc os de yeso polvo de construcci n etc Para m s informaci n y requisitos lea la etiqueta de especificaci n sobre el producto PLANIFICACION DE LA INSTALACION Este calentador ha sido dise ado para proporcionar calefac ci n adicional desde una pared en una construcci n nueva o una ya existente El calentador se puede poner en funcionamiento desde una pared usando el termostato de tensi n de l nea Broan Modelo 86 Adquiera los controles en forma separada Planifique proporcionar al calentador la tensi n de l nea y cable de energ a el ctrica apropiados NOTA La energ a se puede tomar de un circuito cercano lo que depender del vatiaje requerido del calentador y amperaje nominal del circuito El calentador se puede convertir a mitad de vatiaje para evitar sobrecargar dichos circuitos INSTALLER Leave This Manual With The Homeowner HOMEOWNER Use and Care Information on Page 3 INSTALADOR Deje este manual con el due o de casa DUENO DE CASA Informaci n del uso y mantenimiento en la p gina 3 BOLD ratings are factory wired See OPTIONAL WIR ING CONVERSION section for wattage and voltage conversion instructions Follow these basic steps when installing this heater Nail housing to studs Connect power cable Fasten heater assembly and grille to housing FIG 1 PREPARE THE HOUSING t Remove the re
2. 120VCA A 240VCA WHITE WIRES BLACK WIRE from motor CABLES BLANCOS CABLE NEGRO del motor THERMAL OVERLOAD SOBRECARGA TERMICA CONVERTED 240 VAC HEATER CALENTADOR CONVERTIDO 240 VCA LINE IN LINEA DE ENTRADA 240VCA 1 Desconecte del motor UNO de los dos 2 cables negros que tienen terminal aislada 2 Desconecte los dos 2 cables blancos con terminales aisladas No saque el cable blanco debajo del entace de cable pl stico 3 Conecte el cable negro al cable blanco NOTA cuando el calentador se convierte de 120 VCA a 240 VCA no es posible convertir a medio vatiaje COMPLETANDO LA INSTALACION CONSTRUCCIONES NUEVAS 1 Una cubierta de caja se incluye para evitar que el polvo de construcci n roc os de yeso pintura etc da en el calentador Doble las aletas en la cubierta y emp jela dentro de la caja de calentador NOTA la cubierta se puede poner en su lugar antes o despu s de reinstalar el conjunto del ventilador 2 Quite la cubierta antes de la operaci n TODAS LAS INSTALACIONES 3 Fije el conjunto del calentador con el tornillo de retenci n y enchufe el conjunto de cables preconfigurado al enchufe 4 Fije la rejilla al calentador con dos 2 tornillos que se incluyen 5 Conecte la potencia en la entrada de servicio Ponga el termostato en su graduaci n m s alta y compruebe que el elemento de calor y el soplador se enciendan P ngalo despu s en su g
3. 18 18 x 3 8 Ph Pan Head 5 Required Tornillo phillips 8 18 x 3 8 cabeza grande se requieren 5 99270741 Heating Element Model 120 Elemento de calor Modelo 120 99270725 Heating Element Model 124 Elemento de calor Modelo 124 99270742 Heating Elernent Model 128 Elemento de calor Modelo 128 93270619 Wire Clamp Sujetador de cable 97008682 Partition Plate Assembly Conjunto de placa separadora 99260428 Nut 16 32 x 5 16 Keps 2 Required Tuerca keps 16 32 x 5 16 se requieren 2 97008856 Plug Assembly Conjunto de enchufe 97008678 Overload Wire Assembly Conjunto del cable de sobrecarga j Screw 8 18 x 5 8 Ph Pan Head Tornillo 8 18 x 5 8 cabeza grande 97013821 Grille Includes Parts Bag Rejilla incluye Bolsa de piezas A Grille Screw 2 Required Tornillo de rejilla Se requieren 2 93270493 Wire Tie Lazo de cable 99140470 Screw 8 18 x 3 8 Ph Truss Head ps de enlace 8 18 x 3 8 97008724 Parts Bag contains Key Nos 3 20 amp 21 Bolsa de piezas incluye Numeros de codigos 3 20 y 21 Standard hardware may be purchased locally Herrajes estandar pueder comprarse localmente Not shown No ilustrad Always order replacement parts by PART NO NOT by KEY NO Encargue siempre piezas de reemplazo por N MERO DE PIEZA y NO por N MERO DE C DIGO 99042424E
4. NOTE Use other housing knockout when wiring units in parallel FIG 8 2 Connect black to black white to white Use ground ing clip to attach green or bare wire to housing Replace wiring cover FIG 9 OPTIONAL WIRING CONVERSIONS FIGS 10 11 12 1 Conversion to half wattage FIG 10 The heater will produce less heat and use less electricity if converted to half wattage Disconnect ONE of the two 2 black wires with insulated terminals from the motor 2 120 VAC to 240 VAC Conversion FIGS 11 3 12 Factory wired 120 VAC Models 120 and 124 ONLY These heaters can be converted to operate on 240 VAC 1 Disconnect ONE of the two 2 black wires with insulated terminals from the motor 2 Disconnect the two 2 white wires with insulated terminals from each other Do not remove the white wire from beneath plastic wire tie 3 Connect the black wire to the white wire NOTE When heater is converted from 120 VAC to 240 VAC half wattage conversion is not possible MEASURING GUIDES MEASURING GUIDE GUIA DE MEDIDA GROUNDING CLIP SUJETADOR PARA CONEXION A TIERRA La tabla abajo demuestra el grado para cada modelo MODELOS VOLTIOS AMPS VATIOS BTU HR 8 33 4 16 1000 500 3413 1707 4 16 1000 3413 3 61 750 2560 12 5 6 25 1500 750 5120 2560 5 25 1500 5120 5 41 1125 3840 6 33 4 16 2000 1900 6827 3413 7 21 3 61 15001750 5
5. 120 2560 El cableado viene de f brica para las corrientes nominales en letras oscuras Secci n CONVERSIONES DE CA BLEADO ORIGINAL encontrar las instrucciones de vatiaje y conversi n de tensi n Al instalar este calentador siga estos pasos b sicos Clave la caja en las vigas Conecte el cable de potencia Fije el conjunto del calentador y la rejilla a la caja FIG 1 PREPARACION DE LA CAJA Saque el tornillo de retenci n desenchufe el conjunto de cables preconfigurado y saque de la caja el conjunto del calentador FIG 2 2 Saque la cubierta de la caja FIG 3 INSTALACION DEL CALENTADOR VIGAS DE 40 64 CM DE CENTRO SOLAMENTE NOTA sit e la caja a no menos de 15 24 cm 6 pulg del piso o cualquier pared adyacente t Elija cu l lado de la caja se va a montar directamente a una viga de la pared Despu s meta un soporte de montaje desde el lado opuesto dentro del canal en la parte superior de la caja FIG 4 2 Use la gu a de medida que est en el lado de la caja para colocar sta a nivel con la pared terminada Pase dos 2 clavos por los agujeros en el costado de la caja y cl velos en la viga de la pared FIG 5 3 Extienda los soportes de montaje nivele la caja y clave a la otra viga FIG 6 VIGAS DE 60 96 CM 24 PULG DE CENTRO 1 Elija cu l lado de la caja se va a montar directamente a la viga de la pared Desde este lado meta un soporte de montaje hasta lo m s pr
6. EADO ELECTRICO OBTENGA LOS SERVICIOS DE UN ELECTRICISTA COMPETENTE AL HACER EL CABLEADO LIMPIEZA O DAR SERVICIO A ESTA UNIDAD DESCONECTE LA POTENCIA Y ASEGURE EL PANEL DE SERVICIO EL NO HACERLO PUEDE HACER POSIBLE QUE OTRAS PERSONAS O EL TERMOSTATO ACTIVE LA ENERGIA EN FORMA INESPERADA LO QUE PUEDE CAUSAR UN GOPE ELECTRICO MORTAL Para evitar descarga el ctrica NO instale la unidad en una ba era o recinto de ducha ni en ning n lugar donde pueda entrar en contacto con el agua NUNCA coloque un interruptor en un lugar que pueda ser alcanzado desde una ba era o ducha NO instale esta unidad en un rea donde se almacenen o usen productos qu micos u otros productos inflamables De lo contrario pueden producirse explosiones e incendios CUIDADO 1 Este producto SOLAMENTE se puede instalar horizon talmente en una pared NO LO MONTE EN NINGUNA OTRA POSICION Instale el calentador por lo menos a 15 24 cm 6 pulg de distancia del piso o de alguna superficie vertical adyacente NO COLOQUE el calentador detr s de una puerta muebles cortinas etc donde el flujo de aire a la unidad se encuentre restringido Proporcione un circuito el ctrico de capacidad nominal al calentador a fin de impedir la desconexi n de disyuntores o quemado de fusibles V ase el diagrama abajo NO CONECTE EL CALENTADOR A UN VARIADOR DE LUZ O UN CONTROL DE VELOCIDAD Para evitar da os al cojinete del motor e impulsores
7. MODELS 120 124 amp 128 REGISTER HEATERS WARNING 1 ALL ELECTRICAL WORK MUST BE DONE IN ACCORDANCE WITH LOCAL OR NATIONAL ELECTRICAL CODE AS APPLICABLE FOR SAFETY THIS PRODUCT MUST BE GROUNDED IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN 2 WHEN WIRING SERVICING OR CLEANING THIS UNIT TURN OFF POWER AND LOCK OUT SERVICE PANEL FAILURE TO DO SO COULD ALLOW OTHERS OR THERMOSTAT TO TURN ON POWER UNEXPECTEDLY WHICH MAY CAUSE FATAL ELECTRICAL SHOCK 3 To avoid electrical shock DO NOT install unit in a tub or shower enclosure or any location where it may come in contact with water NEVER place a switch where it can be reached from a tub or shower 4 DO NOT install this unit in an area where chemicals or other flammables are stored or used Explosion and fire may result CAUTION 1 This product may ONLY be installed horizontally in a wall DO NOT MOUNT IN ANY OTHER POSITION 2 Install heater at least 6 from floor or any adjacent vertical surface 3 DO NOT locate heater behind a door furniture drapes etc where the air flow to the unit would be restricted 4 Provide heater with an appropriately rated electrical circuit to prevent tripped breakers or blown fuses See chart below 5 DO NOT CONNECT HEATER TO DIMMER SWITCH OR SPEED CONTROL 6 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray const
8. PTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN NU TONE SHALL NOT BE LJABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING QUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not al tow the exclusion or limitation of incidental or consequential dam ages so the above ation or exclusion may not apply to you arranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties To qualify for warranty service you must a notify Broan NuTone at the address or telephone number below b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date Broan NuTone LLC 926 W State Street Hartford Wisconsin 53027 vwww broan com 800 568 1711 DISCONNECT FOR HALF WATTAGE p DESCONECTE PARA MEDIO VATIAJE BLACK A NEGRO THERMAL OVERLOAD SOBRECARGA TERMICA FACTORY WIRED HEATER FULL WATTAGE CALENTADOR CABLEADO DE FABRICA VATIAJE COMPLETO PA a 1 WHITE WHITE paa al LINE IN LINEA DE ENTRADA FIG 10 HALF WATTAGE CONVERSION CONVERSI N DE MEDIO VATIAJE 2 BLACK WIRES connected to motor 2 CABLES NEGROS conectados al motor FIG 11 120VAC TO 240VAC CONVERSION CONVERSION DE
9. dores de pueden convertir para que funcionen en 240 VCA COMPLETE THE INSTALLATION NEW CONSTRUCTION 1 A housing mask has been provided to keep construction dust drywall spray paint etc from damaging heater Bend the flaps on the mask and push it into the heater housing NOTE Mask can be put in place before or after heater assembly is reinstalled 2 Remove mask before operation ALL INSTALLATIONS 3 Secure heater assembly with retaining screw and plug wiring harness into receptacle 4 Fasten grille to heater with two 2 screws provided FIG 13 5 Turn on power at service entrance Turn thermostat to its highest setting and make sure heating element and blower come on Then turn it to its lowest setting and make sure element and blower shut off USE AND CARE WARNING DISCONNECT ELECTRIC POWER AT SERVICE ENTRANCE BEFORE CLEANING OR SERVIC ING UNIT THERMAL OVERLOAD PROTECTOR If heater fails to operate when thermostat is turned to its highest setting Turn power off at service entrance Remove grille and press button marked RESET CLEANING Clean the heater assembly using the round brush tool on your vacuum cleaner Remove large accumulations of dust lint etc that might impede the flow of air through the heater Such blockage will lower its efficiency and create a possible overheating condition To clean grille use a soft cloth which has been moi
10. nes de instalaci n recomendadas como se especifica en ta garant a expresa Algunos estados no pe piador de ventanas casero UIDADO LAS PIEZAS METALICAS Y ELECTRICAS UNCA SE DEBEN SUMERGIR EN AGUA ADA POR UN A O de sus productos les o en mano de al de compra NO GARANTIA BROAN NUTONE LIM nes normales de servicio y uso A PRESENTE GARANT A NO CUBRE LOS TUBOS FLUORESCENTES NI SUS ARRANCADORES BOMBILLAS DE HALOGENO E INCANDESCENTES FUSIBLES FILTROS CONDUCTOS TAPO Y DEM S ACCESORIOS PARA CONDUCTOS Esta garant a no cubre a r ES DE TECHO O PAREDES iento y servicio normales o b cualquier producto o piezas que adas de forma err nea n a se limita a un per odo de un a o iten imitaciones en cuanto al tiempo de expiraci n de una garantia implicita o que la limitaci n antes mencionada puede no aplicarse a usted EXCLUSIVO RECURSO LEGAL DEL COMPRA OBLIGACION DE BROAN NUTONE DE REPARAR O REEMPLAZAR UIENDO EL CRITERIO DE BROAN NUTONE DEBERA SER EL UNICO Y OR BAJO ESTA GARANTIA BROAN NUTONE NO SERA RESPONSABLE POR DA OS INCIDENTALES CONSIGUIENTES O POR DANOS ESPECIALES QUE SURJAN A RA Z DEL USO O DESEMPE O DEL PRODUCTO Algunos estados no permiten la n o limitaci n de da os incidentales o consiguientes por lo que la itaci n antes mencionada puede no aplicarse a usted Esta garant a le proporciona derechos legales especiticos y usted puede tambi n tener
11. ofundo que se pueda dentro del canal en la parte superior de la caja NOTA sit e la caja cuando menos 15 24 cm 6 pulg del piso y cualquier pared cercana 2 Use la gu a de medida que est en un costado de la caja para colocar sta para que quede a nivel con la pared terminada Pase dos 2 clavos por los agujeros en el lado de la caja y cl velos en la viga de la pared FIG 7 3 Fije los dos 2 soportes de montaje juntos con el tornillo que se incluye Nivele la caja y cl vela a la viga opuesta tal como se muestra CABLEANDO EL CALENTADOR TODAS LAS INSTALACIONES 1 Traiga el cable de energ a el ctrica por la abertura del disco removible en una esquina de la caja y fije con el conector apropiado Deje 15 24 cm 6 pulg de cable dentro de la caja NOTA use otro disco removible cuando cablee unidades en paralelo FIG 8 2 Conecte negro a negro blanco a blanco Use el sujetador para conexi n a tierra para fijar el alambre verde o descubierto a la caja Coloque de nuevo la cubierta de cableado FIG 9 CONVERSIONES DE CA BLEADO OPCIONALES FIGS 10 11 12 1 Conversi n a medio vatiaje FIG 10 El calentador produce menos calor y usa menos electricidad si se convierte a medio vatiaje Desconecte del motor UNO de los dos 2 cables negros que tienen terminals aisladas 2 Conversi n de 120 VCA a 240 VCA FIGS 11 y 12 Solamente modelos 120 y 124 cableados de f brica para 120 VCA Estos calenta
12. olros derechos los cuales var an de estado a estado Esta eemplaza todas las garant as anteriores car en la garant a de servicio usted debe a notificar a Broan dom o al n mero de tel fono que se menciona abajo b dar el n mero del modeto y la identificaci n de la pieza y c describir la naturaleza de cualquier defecto en el producto o pieza En el momento de solicitar servicio cubierto por la garant a usted debe de presentar evidencia de la fecha original de compra Broan NuTone LLC 926 W State Street Hartford Wiscon vwww broan com 00 558 1711 SERVICE PARTS PIEZAS DE SERVICIO MODELS 120 124 128 MODELOS 120 124 y128 4 13 A E s Eta KEY NO PART NO DESCRIPTION DESCRIPCION NUMERO NUMERO DE CODIGO DE PIEZAS 1 97008853 Housing Caja 2 98003038 Mounting Bracket 2 Required Soporte de montaje se requieren 2 3 id 8 18 Sheet Metal Nut 2 Required Tuerca de l mina de metal 8 18 se requieren 2 4 99390015 Grounding Clip Fijador de conexi n a tierra 5 97005422 Receptacle Assembly Conjunto de enchufe 6 98006975 Wiring Cover Cubierta de cableado 7 99020130 Blower Wheel Rueda del soplador 8 99080248 Motor Models 120 and 124 Motor Modelos 120 y 124 99080252 Motor Model 128 Motor Modelo 128 99270735 Tab Adaptor Adaptador de leng eta 99030194 Thermal Overload Sobrecarga t rmica 99271091 Guard Protector 98006974 Element Bracket Elemento de soporte 99150491 Screw
13. raduaci n m s baja y compruebe que el elemento y el soplador se apaguen USO Y MANTENIMIENTO P S prendido en su graduaci n m s alt ADVERTENCIA DESCONECTE LA POTENCIA EN LA ENTRADA DE SERVICIO Y ASEGURE EL PANEL ANTES DE HACER LA LIMPIEZA O DAR SERVICIO A LA UNIDAD ROTECTOR DE SOBRECARGA TERMICA i el calentador no funciona cuando el termostato est apague la energ a en la entrada de servicio Quite la rejilla y oprima el bot n marcado RESET LIMPIEZA Li mpie el conjunto de calentador usando el cepillo redondo de su aspiradora Saque las acumulaciones grandes de polvo pelusa etc que puedan impedir el flujo de aire por el calentador Ese bloqueo disminuir la eficiencia y crear una posible condici n de sobrecalentamiento Para limpiar la rejilla use un trapo suave humedecido con C N Broan NuTone garantiza al consumidor comprador ori que dichos productos carecer n de defectos obra por un periodo de un a o a partir de la EXISTEN OTRAS GARANTIAS EXPLICITAS O IMPLICITAS INCLUYENDO PERO NO LIMITADAS A GARANTIAS IMPLICITAS DE COMERCIALIZACION 0 APTITUD PARA UN PROPOSITO PARTICULAR Durante el per odo de un a o y a su propio criterio Broan NuTone reparar o reeraplazar sin costo alguno cualquier producto o pieza que se encuentre defectuosa b accidente o que hayan sido reparadas por otras compa as que no sean Broan NuTone O instalaci n contraria a las instruccio
14. ruc tion dust etc off power unit 7 Please read specification label on product for further information and requirements PLAN THE INSTALLATION This heater is intended to be used to supply supple mental heat from a wall location in new or existing construction The heater can be operated using the Broan Model 86 Line Voltage Thermostat from a wall location Purchase the control separately Plan to supply the heater with proper line voltage and appropriate power cable NOTE Power can be tapped from a nearby circuit depending on the heater wattage required and the amperage rating of the circuit Heater can be converted to half wattage to avoid over loading such circuits The table below lists the ratings for each model MODELS VOLTS ames WATTS BTUJHR 8 33 4 16 1000 500 341311707 4 6 1000 3413 3 61 750 2560 5120 2569 12 5 6 25 1500 750 6 25 1500 5120 5 44 1125 3840 6 33 4 16 2000 1000 721 3 61 1500 750 6827 3413 5120 2560 FIG 1 DRYWALL meee PARED DE pr WALL YESO STUD VIGA DE LA PARED HOUSING CAJA DEL CALENTA MODELOS 120 124 Y 128 CALENTADORES DE REJILLA ADVERTENCIA 1 TODO EL TRABAJO ELECTRICO DEBE REALIZARSE DE ACUERDO CON LOS CODIGOS ELECTRICOS LOCALES Y O NACIONALES CORRESPONDIENTES PARA SU SEGURIDAD ESTE PRODUCTO DEBE SER CONECTADO A TIERRA Si USTED NO ESTA FAMILIARIZADO CON LOS METODOS DE INSTALACION DEL CABL
15. st ened with household window cleaner CAUTION METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER BROAN NUTONE ONE YEAR LIMITED WARRANTY Broan NuTone warrants to the or ginal consumer purchaser of its products that such products will be free from defects in materials or workmanship tor a period of one year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRAN IES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan NuTone will at its option repair orreplace without charge any product or part which is found to be efective under normal use and service HIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS TUBES HALOGEN AND INCANDESCENT BULBS FUS ES FILTERS DUCTS ROOF CAPS WALL CAPS AND OTHER AC CESSORIES FOR DUCTING This warranty does not cover a nor mal maintenance and service or b any products or parts which have been subjeet to misuse negligence accident improper main tenance or repair other than by Broan NuTone faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is limited to the one year pe riod as specified for the express warranty Some states do not al ation on how long an implied warranty lasts so the above n may not apply to you NUTONE S OBLIGATION TO REPAIR OR REPLACE AT BROAN NUTONE S O
16. taining screw unplug wiring harness and lift heater assembly from housing FIG 2 2 Slide the wiring cover out of housing FIG 3 INSTALL THE HEATER 16 ON CENTER STUDS ONLY NOTE Locate housing at least 6 from the floor and any adjacent walls 1 Choose which side of housing will be mounted di rectly to a wall stud Then insert a mounting bracket from the opposite side into the channel at the top of the housing FIG 4 2 Use measuring guide on side of housing to posi tion housing so that it will be flush with finished wall Drive to 2 nails through the holes on side of housing and into stud FIG 5 3 Extend mounting bracket level housing and nail to other stud FIG 6 24 ON CENTER STUDS ONLY 1 Choose which side of housing will be mounted di e push a mounting bracket as tar as possible into the channel at the top of the housing NOTE Locate housing at least 6 from the floor and any adjacent walls 2 Use measuring guide on side of housing to posi tion housing so that it will be flush with finished wall Drive two 2 nails through the holes in side of housing and into stud FIG 7 3 Secure the two 2 mounting brackets together with screw supplied Level housing and nail to opposite stud as shown WIRE THE HEATER ALL INSTALLATIONS 1 Feed electrical power cable through open knockout in corner of housing and attach with appropriate connector Allow 6 of wire inside of housing