Home

Aston SPSS303 Instructions / Assembly

image

Contents

1. ASTON CERA Bringing Serenity to Your Home and Tranquility to Your Every Day Life INSTALLATION AND OWNER S MANUAL AY Shower Panel Model Number SPSS303 Please carefully read these instructions before you begin to install the products 04 11 Rev B P N 100014 04 TABLE OF CONTENTS Before Use Safety Instructions Installation Instructions Operation Troubleshooting Care and Maintenance Warranty Before Use Thank for purchasing an Aston shower panel We hope that this unit provides you with years of satisfying service This instruction manual explains the benefits of using a shower panel and provides installation operation and care instructions for your new Aston shower panel Please read this manual carefully because it contains information and instructions about the safe installation and operation of the shower panel If you do not follow certain conditions of installation and maintenance your warranty may be affected The Aston Shower Panel can convert any shower into a spa experience right in your own home The unit is designed to work with your current plumbing supply lines with standard line pressure and flow rates Modification to your current shower setup can have you enjoying within just a short time the overhead rain shower the shower wand or the soothing body spay jets IMPORTANT This unit is intended for replacement of your current mixing valve setup If you plan to use your
2. shower is above the level of the vacuum break QO e 1550mm 61 Q 195mm 7 165mm 6 1 L Installation Instructions E Plumbing requirements e Water Pressure 60 80 psi for both hot and cold supply lines e Flow rate 9 20 gpm gallons per minute If your water supply is not capable of supplying these minimum requirements please consult a plumber to investigate the addition of a booster pump or enlarging the supply lines The following basic tools are required for installation e Drill with screwdriver attachments Masonry or tile drill bits u S V Caulk gun VI 3 foot level Tape measure Phillips head screw driver Bathroom rated silicone sealant Adjustable wrench Pipe cutter Teflon Tape Items required but not supplied e Supply line connection fittings standard male 3 8 compression threads Optional supply line cut off valves with standard male 3 8 compression threads 5 16 diameter drill bit appropriate for your wall surface Ya diameter drill bit appropriate for your wall surface MPORTANT The approach to this installation assumes that you are remodeling your bathroom The Aston shower panel will replace any existing mixing valve setup The only items needed for operations are separate hot and cold water supply lines If you are considering using your existing mixing valve setup you need to consider using one of Aston s retrofit unit
3. measurement X c Next measure from the top of the notch located on the top strap to the most outside measurement of the bottom of the shower panel and note this reading as measurement Y d Measuring up from the reference mark made earlier when the shower panel was on the wall measure up the distance Y which was the distance from the top of the notch located in the top strap to the bottom outside of the shower panel and make a mark at this location on the center line e Take one of the mounting brackets and center the top mounting hole over the center line and the mark you just made measuring the distance Y The bracket must be flat against the wall with the mounting holes pointing toward the bottom of the shower after aligning mark both hole locations f Measure from the top mounting hole straight down the distance X you measured earlier which is the mea surement between the two notches in the mounting straps Mark this location on the center line g Take the remaining brackets and align the top mount ing hole with mark you just made ensuring that it is vertical and on the center line and mark both holes You now have both mounting location marked h Using the appropriate drill bit for your wall surface drill each hole location with a 5 16 diameter drill bit NOTE If your surface is prone to cracking or chipping then it is recommended that you pilot drill first
4. ack to the OFF position Body jets 1 Rotate the diverter valve to the body jet position 2 Turn the ON OFF valve to the ON position 3 Set the thermostatic valve 4 When finished rotate the ON OFF valve back to the OFF position Shower wand 1 Rotate the diverter valve to the shower wand position 2 Turn the ON OFF valve to the ON position 3 Set the thermostatic valve 4 When finished rotate the ON OFF valve back to the OFF position Troubleshooting No warm water or A Verify that you have A Connect the hot and cold either hot or cold connected the hot and cold supply lines to the correct water only supply to the correct location location on the Thermostatic on the Thermostatic valve valve A colored dot on the valve If the check valves are indicates the hot and cold sticking or stuck attempt to connection red hot blue free up if not possible cold contact mfg Disconnect the supply lines C Open fully all shut off valves from the Thermostatic valve D Possible issue with the and look at the check valves thermostatic valve contact to see for any obstruction or the mfg stuck valve C If you are using shut off valves for the supply lines verify they are fully open Not enough pressure A Verify your line pressure is A Low water pressure consult for body jets 60 80 psi if not consult a a plumber about the showerhead or shower plumber about the possible possib
5. athroom location will void the Warranty All Products are intended for single family residential use only Use of a Product or Products in any non residential non single family setting including but not limited to Rental Commercial or Institutional Properties as defined below will void the Warranty e Rental Property any property rented for profit e Commercial Property hotel motel units apartment buildings multi family dwellings health clubs fitness centers nail salons beauty spa centers time shares bed and breakfast inns private clubs or lodges and the like e Institutional Properties hospitals nursing homes assisted living centers or communities and the like The Warranty does not cover neglect misuse or abuse non authorized modification poor installation accidents normal wear and tear Acts of God excessive heat or other causes beyond the control of Aston Global The Warranty does not cover reimbursement of any labor costs incurred in the removal disassembly reassembly or installation of the Product s including replacement Products issued under the Warranty Aston Global will not be liable for any injuries to any person sustained during the delivery installation or repair of its Products Aston Global will not be liable for and will not reimburse any damages to property resulting from improper installation or use of the Products including but not limited to flooring subfloor tile walls sheet rock conc
6. dware stores or home centers Wiping the unit down with a dry cloth after each use will help keep the stainless from spotting or showing watermarks Showerhead and body jets Based on your water chemistry it may become necessary to clean the showerhead or body jets due to hard water buildup of calcium lime or rust To clean the showerhead or body jets Unscrew the affected jet or showerhead and clean or soak it with a mild solution of vinegar and water 50 50 or commercially available hard water cleaner such as CLR Warranty PLEASE READ THESE WARRANTY TERMS AND CONDITIONS CAREFULLY BEFORE USING YOUR ASTON GLOBAL BATHROOM PRODUCT BY USING THE PRODUCT YOU ARE CONSENTING TO BE BOUND BY THE FOLLOWING WARRANTY TERMS AND CONDITIONS Aston Global Inc Limited Lifetime Warranty Shower Panels Aston Global Inc Aston Global extends the following non transferable limited warranty the Warranty for its bathroom products Product or Products solely to the original purchaser the Owner or Customer of the Product from Aston Global or an authorized reseller Proof of purchase is required to exercise this Warranty The Warranty begins on the date of purchase either from the Aston Global warehouse location or an authorized reseller s location Limited lifetime warranty for shower panel structure and base only This limited lifetime warranty only applies to the structural support and surfaces of the showe
7. e installation does require some understanding of simple plumbing techniques If you are unfamiliar or have question please contact your dealer or a qualified plumber You will need to consider several factors when planning for your installation location While all installations are unique the following are general guidelines 1 The unit is designed for indoor use ONLY 2 Flexible supply hoses are provided We recommend that you consider installing individual cut off valves for the hot and cold water supplies Before starting the installation please ensure that you have inspected all components of the unit and check for broken or damaged sections If you find damage please contact your dealer or the manufacturer Ui as Pil M5x30 M4x20 il 8mm Water supply flex hose F1 2 X3 8 comp Anchors 6 mm Installation Instructions Overhead rain showerhead Body spray jets Diverter ON OFF valve Thermostatic valve gt This vacuum break is a back flow preventer to reduce the risk of backflow occurring and contaminating the drinking water supply Seating and unseating of the diaphragm are accomplished by the presence or absence of water pressure from the supply line The vacuum break has been specifically designed to emit a small amount of water a During the opening and eG of the shower control valves and b upon turning off the shower when the hand
8. e overhead shower e The body jets e The shower wand To operate the diverter valve rotate to the device you wish to use you will feel a click for each location IMPORTANT Based on typical residential water pressure and flow rates all components within the shower will not work at the same time e g overhead shower and body jets together therefore the diverter will only operate one device at a time ON OFF Valve The valve will turn the water ON or OFF for the shower panel You can also adjust the water flow between full ON and the OFF position Turn the valve to the ON position to send water to your selected device Return the valve to the OFF position to stop the flow of water Thermostatic faucet The unit is equipped with a thermostatic faucet for setting the mix between hot and cold water The temperature markings are for reference only as the unit does not elevate the water temperature beyond the temperature of your hot water heater Set the thermostatic faucet to your preferred temperature and your unit will operate at this same temperature with each use unless you change the setting To operate the faucet press the release button and turn it in the direction of your desired temperature Operation Overhead rain showerhead 1 Rotate the diverter valve to the Overhead Rain Shower 2 Turn the ON OFF valve to the ON position 3 Set the thermostatic valve 4 When finished rotate the ON OFF valve b
9. existing setup then consider using one of Aston s retrofit shower panels Aston shower panels come equipped with many enhanced features as standard equipment thus eliminating the need to make costly upgrades Overhead rain shower Handheld shower wand Thermostatic valve Body jets Multi position diverter valve ON OFF Valve Two stainless steel braided flexible connection hoses Safety Instructions Please read and follow all safety Instructions 1 WARNING Read and follow all instructions 2 WARNING Use this unit only for the intended purpose described in this manual do not use attachments not recommended by the manufacturer 3 WARNING Never drop or insert any objects into any opening 4 WARNING Observe reasonable time limits when using this product Long exposures at high temperatures can cause high body temperatures Symptoms may include dizziness nausea fainting drowsiness and reduced awareness These effects could possibly lead to drowning 5 WARNING The water jets produce a stream of water with relatively high pressure Prolonged exposure of high pressure water to a localized area of the body may cause bruising Installation Instructions Please read and follow the installation instructions and guidelines in this section Failure to follow the recommended instructions and installation techniques may lead to possible damage to the unit or the surrounding area and can affect warranty claims ATTENTION Th
10. g straps are above the corresponding mounting brackets Ensure that the flexible supply lines are with in the shower panel enclosure Slide the unit down until it rests on the mounting brackets 4 Next seat the shower panel onto the mounting brackets AD by pulling down on the shower panel until it is seated on S the brackets You will feel a slight movement downward and then the unit stops moving you will have properly seated the unit on the mounting brackets A TT TA R Tg E A E j J Installation Instructions 4 Using bathroom rated caulk or sealant and a caulk gun run a bead of sealant all the around the unit where it is in contact with the shower wall 5 Wipe away any excess using the excess to fill any cracks or voids in the joint Mounting the shower wand holder Based on your unit you may have separate shower wand holder to mount The mounting of this holder will be similar to the mounting of the shower panel mounting brackets Use the following steps to mount the shower wand holder 1 Locate the package containing the shower wand holder and mounting hardware 2 Choose your location for the shower wand based on which the desired height 3 Place the shower wand holder in your mounting location and mark the mounting holes 4 Next using the appropriate drill bit for your wall surface drill each hole location with a Ys diameter drill bit NOTE If your surface is prone to cracki
11. le use of a booster wand addition of a booster pump pump B Verify the diverter is in the B Turn the diverter valve to the proper position not half way correct location you will feel in between 2 locations a Click for each location C Clogged or dirty flow C Remove and clean the flow restrictor restrictor and replace D Clogged or dirty jets D Clean dirty body jets showerhead or shower showerhead or shower wand wand with mild vinegar and water solution A Loose jet faces A Remove and reinstall jet B Loose hose clamps face C Loose supply connection B Tighten loose hose clamps C Tighten loose connection fittings D If leaks persist contact mfg Care and Maintenance ee ee ee Ee a re As with any other luxury item maintenance and care are critical to the long lasting quality and enjoyment of your shower panel The proper care and maintenance outlined in this section are necessary to ensure the longevity of the unit Damage caused by not following the care and maintenance guidelines in this section is not covered under the manufacturer s warranty The shower panel is constructed from durable 304 Stainless Steel With proper care the unit will maintain a clean look and finish for years IMPORTANT Never use an abrasive cleaner such as Comet or Ajax to clean the stainless steel surface as this will scratch the surface and dull the finish You can use any commercially available stainless steel clean available through har
12. ng or chipping then it is recommended that you pilot drill first using a smaller drill bit and then step up to the final size 5 Install the plastic wall anchors provided into the drilled holes ae 6 Mount the shower wand holder using the screws provided a 4x20 with either a Phillips screwdriver or a drill with a Phillips bit pee i 7 Using bathroom rated caulk or sealant and a caulk gun run a inl bead of sealant all the around the shower wand holder where arn iol j it is in contact with the shower wall NG x 8 Wipe away any excess using the excess to fill any cracks or all voids in the joint Installing the shower wand and hose 1 The shower wand hose has two tapered ends One end has an O ring around the outside Install this end onto the shower wand Install the rubber gasket provided before screwing the wand and the hose together 2 The remaining hose end goes onto the outlet spout for the shower wand Install the rubber gasket provided between the hose the outlet spout 3 Place the shower wand into the wand holder The O ring will help hold it in place Operation Before operating this unit ensure you have read and understand all of the warnings and safety statements in this manual If you do not understand any of these warnings or statements please contact your dealer or the manufacturer for an explanation Diverter valve The diverter valve is used to control the flow of water to the following devices e Th
13. r panel against failure due to materials or workmanship for the life of the product The Limited lifetime warranty does not apply to jets fittings tubing clamps thermostatic valve diverter valve shower wand showerhead shower wand hose typical wear items due to daily use such as o rings washers and gaskets 2 year limited parts only warranty This warranty applies to all plumbing components including jets tubing fittings shower head shower wand shower wand hose and supplied connection hoses Only the plumbing fixture components such as faucets diverter valves and Thermostatic valves will be replaced not the entire fixture items Included are valve cartridge check valves and knobs Aston Global warrants the listed items to be free from manufacturing and material defects for the period of the warranty stated Typical wear items due to daily use such as o rings washers and gaskets are not covered by this 2 year limited parts warranty If a part is determined to be covered by the above Warranty Aston Global will ship the replacement part to Customer by either ground shipping or US postal service Increased costs for expedited delivery if requested by Customer are the responsibility of Customer Parts not currently in stock may require up to a 6 week delivery time after placement of order Warranty Limitations Exceptions and Disclaimers All Products are for indoor use only installation outdoors or any other non standard b
14. rete board paint plumbing fixtures and ceilings The Customer accepts any and all responsibility for repair or replacement of any component on the Product Warranty Dee ee a a a a ee ea Limitations THIS LIMITED WARRANTY TAKES THE PLACE OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED IN FACT OR AT LAW INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE NO DEALER DISTRIBUTOR SERVICE COMPANY OR OTHER PARTY IS AUTHORIZED TO CHANGE MODIFY OR EXTEND THE TERMS OF THIS WARRANTY IN ANY MANNER WHATSOEVER Disclaimers Aston Global and it representatives shall not be liable for any injury loss cost or other damages whether incidental or consequential arising out of any defect covered by this Limited Warranty including and without limitation loss of use of the Product and cost for removal of defective Product even if Aston Global has been advised of the possibility of such damage The liability of Aston Global under this Warranty if any shall not exceed the Original amount paid for the Product covered by the Warranty Coverage under this Warranty shall commence as of the original date of purchase and the duration of such coverage shall not extend for any reason whatsoever beyond the stated time period The Customer is required to provide adequate access the Product for any repair or inspection Aston Global shall not be liable for expenses or damage which may include but are limited to wa
15. s designed for this purpose These installation instructions assume you have already completed the following work e Rough plumbing e Finished shower walls are in place Installation Instructions WARNING Turn off the hot and cold water supply to the shower or bathroom where the installation of the shower panel is to take place Connect to supply lines The connection between the shower panel and the supply lines is made with the use of two flexible hoses supplied with the unit The connection to the hot and cold supply lines is not supplied The hoses use standard female 3 8 compression threads with appropriate washers for connections We recommend that you use separate cut off valves for the hot and cold water supply lines Although not necessary this will aid in any future service of the unit Based on your installation purchase the appropriate fitting and valves that will provide male 3 8 compression threads to attach to the flexible hoses You must complete the supply connections before continuing installation of the shower panel Mounting the shower panel brackets When placing the shower panel onto the wall consider the following Consider the relationship of the height of the overhead rain shower to body jets for all persons using the shower We recommended that you set the shower panel at a height that will allow persons of various heights to enjoy both the overhead shower and the body jets Remember you will al
16. so need to consider covering up the connection points for the hot and cold water supplies with the shower panel To locate the shower panel use the following steps You will need a tape measure and pencil or other marking device NOTE You may need a second person to help you up hold the unit while you make the measurements used for installation eae ease 1 Locate the hardware package containing the mounting brackets FT COT TT wall anchors and screws as you will need these items for the Hj Ht next steps 2 Draw a center line on the wall indicting where the center of the shower panel will be placed Typically this will be at the center of the plumbing supply lines 7 Installation Instructions 3 While holding the shower panel at your desired height and location on the center line make a small mark on the wall at the bottom and center of the shower panel This will give you the bottom of the shower panel and is the reference point for making all other measurements for locating the mounting brackets 4 Lay the unit on the ground with the back of the unit facing up and locate the two hanging straps built into the unit 5 Use the following instructions to located the mounting brackets a Units with two notched straps will use two mounting brackets 1 on the top strap and 1 on the bottom strap b Measure the distance between the top and bottom strap between the notches not the strap itself note this measurement as
17. ter damage removal of any and all common building product such as tile flooring wood sheet rock plumbing fixtures concrete board vanities bathtubs and toilets or any other custom items Legal This Warranty gives you specific legal rights You may also have other rights which vary from state to state Some states do not allow limitations of implied warranties so some limitations may not apply to you Aston Global offers free phone support for the life of the Product to the original Owner which is non transferable The Warranty applies only to Products manufactured on or after September 1 2010 This Warranty may not be combined with any other warranty offered by Aston Global ANTON LEEB Customer Service 877 424 9699 Aston Global Inc 1501 10th St Suite 150 PLANO TX 75074 If further assistance is needed or you have a question please visit our web site at www astonglobalinc com
18. using a smaller drill bit and then step up to the final size Installation Instructions Connecting the supply lines y i Install the plastic wall anchors provided into the drilled holes j Attach the mounting brackets to the wall using the JN screws provided with either a Phillips screwdriver or a drill with a Phillips bit O The connection between the shower panel and the supply lines is made with the use of two flexible hoses supplied with the unit The connection to the hot and cold supply lines is not supplied The hoses use standard female 3 8 compression threads with appropriate washers for connections We recommend that you use separate cut off valves for the hot and cold water supply lines Although not necessary this will aid in any future service of the unit Based on your installation purchase the appropriate fitting and valves that will provide male 3 8 compression threads to attach to the flexible hoses You must complete the supply connections before continuing installation of the shower panel Hanging the shower panel After you have completed your leak check hang your shower panel on the mounting brackets Use the following steps to hang the shower panel 1 2 3 Place the shower panel on the wall so that the mountin

Download Pdf Manuals

image

Related Search

Related Contents

Herunterladen - Technische Dokumentation  PDFファイル  Signal Generators Programming Guide  Series 6200 Ca-Calc Combustion Analyzers Operation and  Home Theatre System  User Manual - ValueStore.us  En savoir plus - Académie de Nancy-Metz  Emerson 500-1500VA Quick Start Guide  Tech Craft TRK50B User's Manual  詳しくはこちら - フルブラスト  