Home
Ariel BT-150150 Installation Guide
Contents
1. Attention 1 Turn on the power and make sure it won tsurpass the electric current 2 Make sure to fix leakage protection device andthe socket must be connected with earth line 3 Please don t block the water recycle net by any part of your body if that occurs turn off the pumpor power atonce 4 A switch for the supply of the hot cool water must be installed when stop to use this product The water supply switch and the power source switch should be turned off 5 Check the water level if it is 10 20 mm above the spray nozzle before you start the pump or the pump could be damaged 6 Dispose ofthis product according to the locallaw when itis out ofuse 7 Please contact thelocal dealer forhelp if youhave any problem Circuit diagram OJ e Bottom light Ozone Ba Speaker input of CD frequency Electric box Antenna D Water probe Input of control panel O O 5 Black L White N E T Air bubble pump Green G Water pump Heater The related connectionwill not be connected if the unit without bubble system heat pump bottom light installed I Do not dispose this product as unsorted municipal waste Collection of such waste separately for special mE treatment is necessary INSTALLATION INSTRUCTION MASSAGE BATHTUB MODEL WS 150150 Your Dest ela reel Dear user Thank youvery much for
2. 6 Size 1520X 1520 690mm Remark Auto heat system air bubble pump and the bottom water light are the options for the goods 10 The daily maintenance should be cleaned with ordinary detergent and soft cloth Please do not use the detergent which contains acetone or ammonia liquid Ifthere marks or something like glue on the surface of bathtub just polish it with soft cloth dipping with gas If there are scratches on bathtub surface please polish it with 1500 frosted paper dipping with liquid and burnish it with toothpaste It will be shining again after that If there are furring on the surface of bathtub it can be take away by mild acid detergent for example wipe the bathtub with lemon juice or vinegar which be heated Do not wipe the chrome plated spare parts all the time and do not get in touch with chemical detergent etc Otherwise the surface of chrome plated will be destroyed The product should be clean by soft cloth other than coarse cloth To check the water pipe regularly in order to avoid troubles from crack of water pipes or blocked inside If there are something such as hair stuck inside the jets then just to twist out thejets andremove it To clean hydro massage equipment To full fill hot water which is 40 C and pour 2 L detergent start hydro massage function more than 5 minutes then turn offthe massage function and drain out the water Next to full fill cold water and start hydro massage function for 3 mi
3. purchasing our sanitary ware To enable you to use this product safely and effectively please read this installation and operation manual carefully before use Cautions 1 Please ensure that the product installed reliable electric leakage protection device the power plug contains earth line and make sure it is reliable earthing Check the protect system of leakage protection each time before use 2 Before turn on water pump check if the water level over jets 10 to 20 mm or not make sure regular usage of water pump otherwise it will be destroy because of water leakage 3 Do notturn on water pump heat pump or air bubble pump without water 4 People with Hypertension symptom after drink or heart disease are not allowed to use the bathtub Children have a bath must under adult s guidance 5 During use please noticed that don t blocked the jets and avoiding the air adjustment valve overflowing Also keep the bathtub clean and don t let it blocked by hair or mess 6 During use please firstly adjust the water temperature or it will be burned 7 The outdoor spa is designed with ergonomic rise and fall changes are quite big so during use pay more attention of being slipped 8 Please shut down the system when not to use Technical paramete 1 Voltage 220V 60Hz 2 Hydraulic pressure 0 1 0 2Mpa Storage capacity 0 36m Storage capacity 79gallon 3 Power ofthe water pump 750W 4 Power ofthe air pump 200W 5 Power ofthe heat pump 1500W
4. nutes then turn off the massage function and drain out the water at last to dry the bathtub with towel Filter should be clean once a week Keep out from combustibles and goods which over 80 C to avoid fire disaster and damage the product The bathtub should be transported carefully Do not lay heavy things on it and do not bump and shaking the tub If the bathtub has not been used fora long time drain out the water of the bathtub and keep it in a dry and ventilate environment Avoid corrosive gas Troubleshooting 1 Electricity leaki tection devi toff No power or ectricity leaking protection device cuto electricity leaking oe E 1 check andreconnect the wiring system power source whenelectricity line isnot well i i 2 check the power source electricit protection device connected n R is activated 2 Power orelectricity circuit have phenomenon circuit and ground line of electricity leaking 1 check the system whether is on 1 turn onthe system Water Jetsare 2 the impeller of water pump doesn trotate 2 check throughand remove the garbage hich is insideth Switch pi not working 3 water pump is broken which caused by ware ee ae ara ee can be removed working without watercoming in s iictalllanewwateeoune 1 water pump s suctionhas not enough power 1 check the water pump whetheris The intensity of hydro massage 2 air adjustment valveis abnormal working normally 2 change the airadjustment valve cann
5. ot be adjusted 3 jets or nozzles are blocked 3 remove things which are blocking the jets 1 seal ring is broken 1 chang seal ring Water leaks from 2 screws doesn t lock tightly 2 lock thescrews tightly the pipes 3 pipes doesn t seal properly 3 re seal the silicone 4 water pipe isbroken 4 change water pipe 1 Re connect the power source andcheck the electricity leaking switch button 2 change anew control panel Lighting is off 1 Electricity line didn t connect to power source Control panel o electricity leaking protectiondevice cut offpower dogstiiwork 2 power buttonis not working 1 voltage isabnormal l please use itat the normal situation Jets shower can 2 Switch cannotbe work of voltage 2 check andchange the switch not be work 3 control panel cannotbe work ae 3 maintain and changethe control panel 4 water inelectromagnetism valve is be blocked 4 get rid ofmess of thejets 1 The bulb is broken 1 change a new bulb 2 power lineis disconnected 2 re connect the circuit No lighting 3 control panel isbroken 3 maintain orchange control panel l speaker is broken 1 change a new speaker Radio is off 2 power lineis disconnected 2 reconnect the circuit 3 control panel is broken 3 maintain orchange control panel Cold water pipe O Hot water pipe 770 1520 Shower ca Shower chain Red pipe hot water pipe blue pipe cold water pi
6. pe Yi Earth line SIZE 1520 x 1520 x 690mm 1 pillow 2 nozzle 3 control panel 4 air conditioning 5 drainage switch 6 drainage T water jet 8 water jet 9 water in 10 shower 11 tap 12 switch 13 cold hot water switch 14 air bubble jet 15 bottom light 5 Bubble Press W to start the air bubble pump then the symbol will be shown onthe screen The bubble jets spurt out air bubble Press againto screen a oaae turn offthe bubble frequency backward bottom light volume up heater volume down air bubble pump 6 Heater water pump switch Press eao to startthe heater then the symbol will be shown on the radio CD on off screen The heater could keep temperature of waterin the bathtub Press The related buttonshas no effectif the unit it again to turn off the heater ithout bubble system heat pump bott n ae I The remote control iswaterproof and dampproof Remark The massage bathtub has installed water probe If it is 2 The usage of remote control and the function of control panel is basicallythe same oe waterless or the water lower than the top of probe the air bubble pump R tie control P r irea b ara 3 Lay the remote controlwith care and don tthrow it oo E y water pump and heater will not work 1 Start Press Guon button to start the system and LCD with display function At the 7 Ozone same time all functions will standby Press LOK to start ozone di
7. sinfection and press it again to turn off 66 22 Repress button to shut down the system the function This function should be used after bath 2 Fill water Turn onthe cold or hot water switch to fill water into the bathtub Turn the cool or hot water switch to adjust the water filling speed and water temperature Turn the shift switch to use shower head or faucet to fill water Stop to fill water when the water level 1s 10 20mm above the massage nozzle 8 Radio CD Press Ela to open the radio at the same time the symbol appears on the screen Press una CNY between 87 5MHz to 108 0MHz to search the channel and press it again to search different channels Press way to the turn down volume and press Gary to turn up the 3 Bottom light volume The volume will be shown on the screen and the adjustable Press to turn on the bottom lights then the symbol will be shown on range is 0 40 the screen Press again to turn offthe bottom lights Press again toturn offthe radio and turn on the CD At the same time the symbol will appear on the screen Press it again to turn off the 4 Hydraulic massage adoa CD After system startup water in bathtub exceeds the head level then press button to start water pump and meanwhile waterpump symbol f shall be l l 9 Power off displayed on LCD Repress button to stop waterpump function Press to stop all functions Turn the drainage to let ou
8. t the water turnoff the power source and the water supply
Download Pdf Manuals
Related Search
Related Contents
Máquina de cortar Philips Cordless phone answer machine GPS Draft cycling computer User Manual Introduction Getting Started Development of a low power hand-held device in a low User Manual - Visual Plus 取扱説明書 - Cateye Télécharger la fiche USER`S MANUAL - Pdfstream.manualsonline.com スプリンクラーヘッド格納箱EP 取扱説明書 Planar Systems PL2410W Copyright © All rights reserved.