Home

Barclay Products TKCTRN60-SN4 Installation Guide

image

Contents

1. holding riser pipe of Converto shower if previously purchased The headless set screw is used for attaching the riser pipe to the tee 4 14 09 P 847 244 1234 www barclayproducts com
2. Tub Wall Mounted fA Cat No Faucet with Hand Shower 4602 BARCLAY INSTALLATION INSTRUCTIONS Parts Included e 1 Valve Body w Elephant Spout 1 Shower Head 1 Hose 1 Cradle 4 Washers 2 Adjustable Swivel Mounts e 2 Metal Washers 2 Large Locknuts 2 Connector Nuts 2 Threaded Nipples Tools Needed e Adjustable Wrench Slip Joint Pliers Pipe Putty or Teflon Pipe Tape NOTE Handles are identified HOT and COLD The hot handle must be to the left and cold to the right Be sure the water supply is turned off before starting installation Cushion the wrench or slip joint pliers with an old cloth to protect the finish of the fixture shower head hose ol Shower Assembly amp Tub Mount Instructions washer 1 Align the valve assembly with the swivel mounts and secure with Ma S the nuts on the swivel mounts Rubber washer must be in place i i 1 per side Tighten with a wrench Note Mounts may be positioned up or down depending how high hose you would like the spout placed and the hole spacing 2 Apply teflon tape to both ends of the hot and cold supply nipples Thread the tapered ends of the nipples into the swivel mounts on the outside of the tub Thread the large locknuts and metal washers onto the other ends of the nipples and secure the shower set to the tub Position the threaded hose outlet to the left or right 3 Install a washer in the cradle nut and thread the cradle on
3. flange B Measure the distance from the center of the wall flange to the ceiling Important From this measurement deduct one 1 2 This will give you the length of the ceiling support rod needed If the ceiling support rod must be shortened cut the non threaded end of the rod to the length desired by using a hacksaw Attach the flange with a set screw to the non threaded end and then attach the ceiling support rod to the ceiling tee 2 3 Screw the wall support rod 6 to the wall tee 5 Place wall support into flange previously mounted on wall see 2A Determine if the wall support rod should be shortened The wall tee 5 should be approximately even with the front rim of the tub when viewed from the side If necessary cut the non threaded end of the support rod 4 Again place the wall support rod 6 into the flange which is attached to the wall The ceiling flange should now be touching the ceiling Mark the location of the holes of the ceiling flange on the ceiling with a pencil Drill holes where marked on the ceiling Remove the ceiling flange from the ceiling support rod 3 Install the ceiling flange using the wood screws If necessary use plastic expansion plugs not provided It is important that the ceiling flange be mounted as securely as possible 5 Insert wall support rod into wall flange and ceiling support rod into flange then tighten the set screws securely Note Wall support tee 5 has additional hole through tee for
4. n shoe Cleaning Instructions 5 Trim bottom of tube 1 to fit into Tee 5 Wipe this whole set off with warm water and a 6 Trim tube 11 to fit soft cloth DO NOT use soaps cleansers or brass cleaners as they will disintegrate the 7 Tighten the nuts protective lacquer coating and leave the brass exposed causing it to tarnish NOTE Please seek professional help if you have copper plumbing in your home 1 8 08 P 847 244 1234 www barclayproducts com Rectangular Cat No LA Shower Rod Unit PSDA BARCLAY INSTALLATION INSTRUCTIONS Parts Included e 2 Curtain Frame Sections 1 Wall Tee 1 Ceiling Tee e 1 Wall Support 10 Long 1 Ceiling Support 30 Long 2 Flanges e 4 Wood Screws 10 Set Screws w Heads 1 Headless Set Screw ie 3 Tie _ a he i iat Side Wall Support ogo 1 Connect both halves of the curtain frame 1 using the ceiling tees and wall tees as shown above In order to insure a solid fit the tees fit snugly over the frame tube Install 4 set screws in each tee 2 Remove wall support 6 ceiling support 3 and 2 flanges 4 from the carton Determine the correct length of the support rods as follows A Hold one flange 4 to the wall at desired height from the inside of the tub and centered over the tub Mark the position of the holes to be drilled Fasten the flange to the wall with the wood screws keeping the set screw hole on the top side of the
5. screws Use anchors if necessary d Slide threaded end of top supply tube into tube fasteners 6 Assemble supply tube into top of stop valve Tighten screws on tube fastener Cleaning Instructions Wipe this whole set off with warm water and a soft cloth DO NOT use soaps cleansers or brass cleaners as they will disintegrate the protective lacquer coating and leave the brass exposed causing it to tarnish NOTE The Gold Nuts are extra pieces for use with your plumbing They are not necessarily needed for your installation Please seek professional help if you have copper plumbing in your home 3 22 12 P 847 244 1234 www barclayproducts com Leg Tub Cat No 4 Drain 9999 BARCLAY INSTALLATION INSTRUCTIONS Parts Included e Top Overflow Tube 1 Bottom Shoe 2 Top Waste Flange 3 Face Plate 4 Exposed Tee 5 e Face Sponge Gasket 6 e Waste Gasket 7 Lift Stop 8 2 1 1 2 Nut and Washers 9 Face Plate Screw 10 1 1 2 x 6 Tube 11 1 1 2 O D Escutcheon 12 Tools Needed e Wrench Pliers Teflon Tape use as a sealant on all male threaded tubing Tube Cutter Plumbers Putty To Assemble Tubes 1 Assembled 3 and 8 screw into 2 7 is on top of 2 beneath the tub Place a bead of plumbers putty around bottom of 3 to seal to tub and protect from leaks Then tighten 3 into 2 2 Assemble overflow Follow diagram 3 Set 1 in place 4 Place Tee 5 o
6. ted to a Stop Valve 14 Screws 14 Anchors e e 2 Connecting Nuts and 2 Flat Rubber Washers 2 Flat Floor Flanges 2 Wall Mounts 2 Wall Support Tubes 2 Tube Fasteners e Tools Needed e Wrench Pliers Teflon Tape use as a sealant on all male threaded tubing This water supply tube kit includes the parts listed above ONLY The faucet in your bathtub should be purchased previously and separate from this kit This should NOT be used with faucets that use shower risers and shower rods or with leg tubs that have factory drilled holes Wall Supports 1 First be sure to shut off the the water supply Remove old water supply tubing Place a flat rubber washer onto the upper end of each supply tube 2 Screw flat floor flange on to 5 shaft with stop valve attached Be sure to leave enough thread to go through floor to attach to your plumbing 3 Screw flange back down till level with floor Attach to floor with provided screws 4 If rubber washers are inside connecting nuts remove them Slide connecting nut over the thread end of the supply tubes and up over the fittings So that the fittings are completely inside the connecting nuts Place washers deep inside of connect nuts 5 When fastening supply tube to wall mounts a Attach wall mount flanges to the wall support tubes b Attach tube fasteners to wall support tubes and tighten screws c Decided where supports will be attached to the wall and fasten with provided
7. to the valve l i valve assembly assembly Tighten with a wrench 4 Install washers on the hose ends and attach the hose to the cradle and shower head handle DO NOT OVERTIGHTEN 5 Attach cold water supply pipe to cold water side of valve assembly Same with hot on other side To Connect Shower Set to Tubes NOT INCLUDED 1 First remove the round rubber washer from the end of each water supply tube and dispose of them 2 Put the cone washers on the tub and connect the end of each water supply tube Then slide the 1 2 connecting nuts over the opposite ends of the supply tubes and up to the cone washers 3 Twist the connecting nuts over the cone washers and thread the nuts onto the nipples 4 Connect the other ends of the water supply tubes to your house water lines Consult your local plumber for assistance NOTE Please seek professional help if you have copper plumbing in your home Cleaning Instructions Wipe this whole set off with warm water and a soft cloth DO NOT use soaps cleansers or brass cleaners as they will disintegrate the protective lacquer coating and leave the brass exposed causing it to tarnish 2 13 08 P 847 244 1234 www barclayproducts com Freestanding Bath Cat No Supplies 4502 PL BARCLAY ASSEMBLY INSTRUCTIONS These instructions are for assembly of bath supplies ONLY not for connection to water supply Parts Included e Left Supply Tube Right Supply Tube 2 Shafts each connec

Download Pdf Manuals

image

Related Search

Related Contents

Desa GWN10 User's Manual  Betriebsanleitung  HP Grill Accessory B User's Manual  Samsung B100 Uživatelská přiručka  Manual - Northern Tool + Equipment  Respiratory (PDF 16MB)  Smeg CSU2001B1 Instructions for Installation and Use    REVELPROG IS - User Manual ()  instailatiûnandgperaï`ing instructions montage et mode d`emploi  