Home
American Standard 2000.100.002 Installation Guide
Contents
1. American Standard Installation Instructions CERAMIX 2000 10X Centerset Lavatory Faucet with 2000 16X Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain a feature found only on American Standard faucets Certified to comply with ANSI A112 18 1 Speed Connect Drain M968760 Rev 1 3 Fewer parts installs in less time Never needs adjustment Guaranteed to seal properly the first time every time Your new American Standard faucet is designed to work only with the Speed Connect drain Heplful tips for removing your current drain can be found in the Troubleshooting section of these instructions To ensure that your installation proceeds smoothly please read these instructions carefully before you begin Recommended tools EN Screwdriver Channel Locks Turn off hot and cold water INSTALL FAUCET MMT Auen Before beginning Seat SEAL 1 into under side of FAUCET BASE 2 Feed FAUCET SUPPLIES 3 MOUNTING STUD 4 and DRAIN CABLE ASSEMBLY 8 through ESCUTCHEON 9 optional and the mounting hole of lavatory or mounting surface Fig A From below push GASKET 7 and RETAINING WASHER 5 onto MOUNTING STUD 4 Secure Faucet with MOUNTING NUT 6 pulling faucet to front of sink so SUPPLIES 3 rests against LOS Before final tightening make sure collar on MOUNTING NUT 6 is seated into RETAINING WASHER 5 Fig B Adjust Faucet so that it is c
2. GE SCREWS M952430 0070A CABLE ASSEMBLY M962457 YYYOA FLANGE ASSEMBLY 023529 0070A CARTRIDGE KIT M962525 YYYOA M922872 0070A LIFT ROD CAM SEAT INSERT 3 M952425 YYYOA 3 M962430 0070A M961745 0070A DRAIN ASSEMBLY ae aM ASSEMBLY MANIFOLD KIT 5 M913207 0070A TAILPIECE INSERT M919660 0020A 6 TAILPIECE NOT INCLUDED Sa A919661 0020A 911708 0070A EN TAILPIECE oe SEAL A922869 YYYOA AERATOR M962458 0070A DRAIN MOUNTING KIT M962492 0070A MOUNTING KIT 066116 YYYOA DRAIN STOPPER M907671 YYYOA ESCUTCHEON COMPLETE DRAIN ASSEMBLY 066117 YYYOA M953450 YYYOA 2 FLANGE KIT M961747 YYYOA LIFT ROD m 072574 0070A 066118 0070A j ae ROD PIVOT ROD KIT M961711 0070A 3 TAILPIECE INSERT 070847 0070A CLIP HOT LINE FOR HELP For toll free information and answers to your questions call 070532 0040A gt 1 800 442 1902 TAILPIECE 2 Weekdays 8 00 a m to 6 00 p m EST yA IN CANADA 1 800 387 0369 TORONTO 1 905 306 1093 POP UP DRAIN ASSEMBLY X Weekdays 8 00 a m to 7 00 p m EST BEFORE 01 07 IN MEXICO 01 800 839 12 00 Product names listed herein are trademarks of American Standard Inc OAmerican Standard Inc 2002 M968760 Rev 1 3
3. RASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE M968760 Rev 1 3 Speed Connect Drain Troubleshooting Guide If sink does not hold water even though Stopper is in the down position e Follow CABLE ADJUSTMENT PROCEDURE If Sroppar does not raise up fully or sink drains too slowly e Follow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper e Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain e Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode CABLE ADJUSTMENT PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam in the illustration Fig B Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go At this point the Stopper should be in the UP position Fig B C Push DOWN on the Lift Knob to make sure it is fully down Fig C Re attach the Cable to the Drain Body Connection 2 by threading the Cable Connector 1 clockwise onto the Drain Body Connection 2 and hand tighten Fig A CM A MT C STOPPER REMOVAL PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component lab
4. eaks Tighten if necessary 1 SERVICE IF FAUCET DRIPS HOT LIMIT SAFETY STOP m If faucet drips operate handle several times from By restricting handle rotation and limiting the amount of hot off to on Do not apply excessive force water allowed to mix with the cold the HOT LIMIT SAFETY E Clo ged CARTRIDGE inlets may cause reduced flow STOP reduces risk of accidental scalding To set the maximum in full on hot or cold To clean inlets first turn off hot water temperature of your faucets all you need water supply then to do is adjust the setting on the HOT LIMIT SAFETY STOP m Remove HANDLE 1 CAP 2 SCREWS 3 and E Remove necessary trim parts Use a flat blade screwdriver or CARTRIDGE 4 Clean inlets and MANIFOLD 5 pull forward with your fingers to rotate red HOT LIMIT SAFETY m Reassemble CARTRIDGE 4 alternately tightening STOP Follow Step A or B to adjust max min discharge temperature O being the hottest to 7 the coldest na Replace CAP 2 and HANDLE 1 temperature setting ig ADJUSTMENT WHEN WATER IS TOO HOT A POINTER ON HOT LIMIT STOP Mr PRY RED RING FORWARD AND ROTATE COUNTER gr ADJUSTMENT WHEN WATER IS TOO COLD B PRY RED RING FORWARD AND ROTATE CLOCKWISE RED RING HOT LIMIT SAFETY STOP 1 2 CARE INSTRUCTIONS DO SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER DRY WITH A SOFT COTTON FLANNEL CLOTH DO NOT DO NOT CLEAN THE PRODUCT WITH SOAPS ACID POLISH AB
5. eled as Cam and Cam Cap in the illustration Fig B Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain Fig D Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal Fig E The Stopper can now be removed by lifting it out of the Drain Fig F AG _ REMOVE REMOVE CAM CAP M968760 Rev 1 3 STOPPER INSTALLATION PROCEDURE The Stopper can be installed two ways Locked Mode Stopper cannot be removed or Unlock Mode Stopper is removable Locked Mode Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig G To install the stopper in Locked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the Sink and the American Standard logo is facing front Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig G Re install the Cam into the Drain rotating the Cam if necessary A to make sure it is fully inserted Fig J LOOP TOWARD REAR OF SINK Re install the Cam Cap making sure the guide teeth are facing Cy outward If the Cam Cap does not snap into place then rotate DRAIN the Cam to make sure it is fully inserted Fig K Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Locked Mode Troubling Shooting Guide to complete installation Stopper will be Vandal Proof i
6. entered Tighten MOUNTING NUT 6 to complete faucet mounting INE ES Se SS COLLAR ON PA MOUNTING NUT 2 POP UP DRAIN m Remove CLEAR PLASTIC COVER 1 m Remove CARDBOARD SPACER 2 from under DRAIN POP UP 3 m Tighten TAILPIECE 4 on DRAIN BODY before installing DRAIN BODY Fig B Wi 3 REMOVE FLANGE E Thread FLANGE 1 counter clockwise and remove FLANGE 1 and FOAM GASKET 2 from drain body Fig A m Thread LOCKNUT 3 clockwise to bottom of drain body Push GASKET 4 down against LOCKNUT 3 Fig B INSTALL DRAIN FROM BELOW FIXTURE REAR From under side of SINK OF SINK Tighten LOCKNUT 1 firmly with Adjustable install DRAIN BODY 1 up Wrench or Channel Locks through drain outlet Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 2 must face towards the rear of the SINK Install FOAM GASKET 3 and FLANGE 4 onto drain body from above SINK and tighten FLANGE 4 firmly FLANGE GASKET AND POP UP KNOB Check DRAIN FLANGE in SINK to ensure that WHITE FOAM GASKET 3 is fully compressed and not visible Fig A i WHITE FOAM POP UP KNOB 1 must be fully down Fig B GASKET DRAIN NOT VISIBLE FLANGE M968760 Rev 1 3 7 ATTACH CABLE CONNECTOR m Thread CABLE CONNECTOR 1 clockwise onto DRAIN BODY CONNECTION 2 and hand tighten Fig A Your new POP UP DRAIN installation is now complete Fig B Note Tailpeice on p
7. n Locked mode and not be removable Unlocked Mode Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H Re install the Cam into the Drain rotating the Cam if necessary to make sure it is fully inserted Fig J LOOP TOWARD FRONT OF SINK Re install the Cam Cap making sure the guide teeth are facing Da outward lf the Cam Cap does not snap into place then rotate DRAIN the Cam to make sure it is fully inserted Fig K Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Unlocked Mode Troublingshooting Guide to complete installation Stopper will be in Unlocked mode and removable INSTALL CAM CAP M968760 Rev 1 3 An rican Standard CHAMIX y Center Set Lavatory Faucet Replace the YYY with with Pop up Drain appropriate finish code CHROME MODEL NUMBERS a 2000 10X WHITE CHROME 2 000 Pi 1 6X BLACK NICKEL POLISHED BRASS M961741 YYYOA SATIN HANDLE KIT SATIN POL BRASS CHROME POL BRASS A907086 YYYOA 030126 0070A CAP NA HANDLE INDEX SET M962456 YYYOA STOPPER ASSEMBLY 918633 0070A CARTRID
8. op up drain is 1 1 4 O D Fig B CHECK OPERATION OF POP UP Operate LIFT KNOB 1 to verify that STOPPER 2 opens and closes Note If STOPPER 2 does not open and close properly then refer to the troubleshooting section of these instructions 9 MAKE WATER SUPPLY AND WASTE CONNECTIONS m Connect FLEXIBLE SUPPLIES 1 2 directly to wall supplies Connection on fitting supplies are 3 8 compression Connect left SUPPLY 1 to Hot Marked with a Red Band and right supply to COLD 2 wall supply Faucet supplies are 20 long from faucet base Note If additional supply length is required installer must purchase additional parts separately Important If SUPPLY HOSES 1 2 are to long loop as illustrated to avoid kinking Connect 1 1 4 O D tailpiece on POP UP DRAIN to n waste outlet Ox 20 BLUE BAND 3 8 COMPRESSION M968760 Rev 1 3 1 0 TEST INSTALLED FITTING With HANDLE 1 in OFF position turn on WATER SUPPLIES 2 and check all connections for leaks m Remove AERATOR 3 Operate HANDLE 1 to flush water lines thoroughly Replace AERATOR 3 CHECK DRAIN CONNECTIONS Operate POP UP KNOB 4 and fill lavatory with water Check that DRAIN STOPPER 5 makes a good seal and retains water in SINK If DRAIN STOPPER 5 does not seal properly please refer to Troubleshooting section in these instructions Release POP UP KNOB 4 down and check all drain connections and P trap for l
Download Pdf Manuals
Related Search
Related Contents
JVC RX-E111RSL User's Manual 取扱説明書 Rhythm Turn User Manual Zanussi ZCE7610 User's Manual PowerPoint プレゼンテーション User manual - ESPrit/22 sound processor and accessories Presentación - Asociación XBRL España Copyright © All rights reserved.
Failed to retrieve file