1. To install the stopper in Locked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the Sink and the American Standard logo is facing front Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig G Re install the Cam into the Drain rotating the Cam if necessary to make sure it is fully inserted Fig J U LOOP TOWARD REAR OF SINK Re install the Cam Cap making sure the guide teeth are facing Core outward If the Cam Cap does not snap into place then rotate DRAIN the Cam to make sure it is fully inserted Fig K Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Locked Mode Troubling Shooting Guide to complete installation Stopper will be Vandal Proof in Locked mode and not be removable Unlocked Mode Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H Re install the Cam into the Drain rotating the Cam if necessary to make sure it is fully inserted Fig J LOOP TOWARD FRONT OF SINK Re install the Cam Cap making sure the guide teeth are facing Gyan outward If the Cam Cap do
2. 1 and FOAM GASKET 2 from drain body Fig A E Thread LOCKNUT 3 clockwise to bottom of drain body Push GASKET 4 down against LOCKNUT 3 Fig B INSTALL DRAIN FROM BELOW FIXTURE From under side of SINK install DRAIN BODY 1 up through drain outlet Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 2 must face towards the rear of the SINK Install FOAM GASKET 3 and FLANGE 4 onto drain body from above SINK and tighten FLANGE 4 firmly FLANGE GASKET AND POP UP KNOB Check DRAIN FLANGE in SINK to ensure that WHITE FOAM GASKET 3 is fully compressed and not visible Fig A POP UP KNOB 1 must be fully down Fig B a N VUK KG WHITE FOAM GASKET NOT VISIBLE NU Tighten LOCKNUT 1 firmly with Adjustable Wrench or Channel Locks DRAIN FLANGE M968876 Rev 1 2 F ATTACH CABLE CONNECTOR m Thread CABLE CONNECTOR 1 clockwise onto DRAIN BODY CONNECTION 2 and hand tighten Fig A Your new POP UP DRAIN installation is now complete Fig B Note Tailpeice on pop up drain is 1 1 4 0 D Fig B CHECK OPERATION OF POP UP Operate LIFT KNOB 1 to verify that STOPPER 2 opens and closes Note If STOPPER 2 does not open and close properly then refer to the troubleshooting section of these instructions 9 MAKE WATER SUPPLY AND WASTE CONNECTIONS NOTE FLEXIBLE SUPPLIES OR BULL NOSE RISERS NOT INCLUDED AND MUST BE PURCHASED SE
3. from OFF to ON position Do not force handles they turn only 90 To Change Direction Of Handle Rotation Proceed As Follows E Turn VALVE to OFF position E Loosen SET SCREW 2 and pull HANDLE 1 off Remove ADAPTER SCREW 4 and pull ADAPTER 3 off VALVE STEM 5 Cer SS E Turn ADAPTER 8 90 so that flat within ADAPTER 8 catches a different flat on the VALVE STEM 5 E Replace ADAPTER 3 ADAPTER SCREW 4 and HANDLE 1 Tighten SET SCREW 2 To Clean Aerator m AERATOR 6 may accumulate dirt causing distorted and reduced water flow Remove AERATOR 6 and rinse clean 1 2 CARE INSTRUCTIONS DO SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER DRY WITH A SOFT COTTON FLANNEL CLOTH DO NOT DO NOT CLEAN THE PRODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE M968876 Rev 1 2 Speed Connect Drain Troubleshooting Guide If sink does not hold water even eur Stopper is in the down position e Follow CABLE ADJUSTMENT PROCEDURE If Stopper does not raise up fully or sink drains too slowly e Follow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper e Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain e Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode CABLE ADJUSTMENT PROCEDURE Disconnect the Cable from the Drain by threading the
4. Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam in the illustration Fig B Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go At this point the Stopper should be in the UP position Fig B C Push DOWN on the Lift Knob to make sure it is fully down Fig C Re attach the Cable to the Drain Body Connection 2 by threading the Cable Connector 1 clockwise onto the Drain Body Connection 2 and hand tighten Fig A STOPPER REMOVAL PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam and Cam Cap in the illustration Fig B Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain Fig D Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal Fig E The Stopper can now be removed by lifting it out of the Drain Fig F REMOVE CAM CAP M968876 Rev 1 2 STOPPER INSTALLATION PROCEDURE The Stopper can be installed two ways Locked Mode Stopper cannot be removed or Unlock Mode Stopper is removable Locked Mode Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig G
5. Installation Instructions COLONY SOFT Centerset Lavatory Faucet 2275 409 with Speed Connect Drain 2275 509 Congratulations on purchasing your American Standard faucet with the Speed Connect drain a feature found only on American Standard faucets Speed Connect Drain e Fewer parts installs in less time e Never needs adjustment e Guaranteed to seal properly the first time every time Your new American Standard faucet is designed to work only with the Speed Connect drain Certified to comply with ANSI A112 18 1 To ensure that your installation proceeds smoothly please read these M968876 Rev 1 2 instructions carefully before you begin Recommended tools y 4 Te See ee OD Screwdriver Channel Locks Adjustable Wrench Plumbers Putty or Caulking Tubing Cutter INSTALL FAUCET Apply a bead of putty along the edge of the underside of the FAUCET 1 Insert FAUCET 1 and CABLE CONNECTOR 2 through center hole of mounting surface Fig A From under side of mounting surface thread the two MOUNTING NUTS 3 onto FAUCET SHANKS 4 Fig B Center FAUCET 1 and hand tighten MOUNTING NUTS 3 to secure FAUCET 1 HAND TIGHTEN 2 POP UP DRAIN m Remove CLEAR PLASTIC COVER 1 m Remove CARDBOARD SPACER 2 from under DRAIN POP UP 3 E Tighten TAILPIECE 4 on DRAIN BODY before installing DRAIN BODY Fig B 3 REMOVE FLANGE E Thread FLANGE 1 counter clockwise and remove FLANGE
6. PARATELY Connect water supply to INLET SHANKS 1 with 1 2 IPS FLEXIBLE SUPPLIES 2 or 3 8 0 D BULL NOSE RISERS 3 Use adjustable wrench to tighten connections Do not over tighten Be careful not to kink copper supply when bending f amp Use tubing cutter to cut to proper length r 3 3 8 0 D BULL NOSE Connect HOT water supply to inlet of left SHANK and COLD A RISERS water supply to right SHANK using sealant appropriate connectors and COUPLING NUTS 2 COUPLING NUT WITH Connect 1 1 4 O D TAILPIECE 4 on POP UP wage ed eee DRAIN to p trap SUPPLIES 2 COMPRESSION NUT FLEXIBLE SUPPLIES 3 8 COMPRESSION CONNECTION M968876 Rev 1 2 1 0 TEST INSTALLED FITTING m With HANDLES 1 in OFF position turn on WATER SUPPLIES 2 and check all connections for leaks Ensure that AERATOR 8 is tightened completely Operate HANDLES 1 to allow water flow CHECK DRAIN CONNECTIONS Operate POP UP KNOB 4 and fill lavatory with water Check that DRAIN STOPPER 5 makes a good seal and retains water in SINK If DRAIN STOPPER 5 does not seal properly please refer to Troubleshooting section in these instructions TE mr ASD Release POP UP KNOB 4 down and check all drain connections and P trap for leaks m Tighten if necessary 4 P TRAP If Faucet Drips Proceed As Follows E Turn VALVE to OFF position E f spout drips operate HANDLES 1 several times
7. es not snap into place then rotate DRAIN the Cam to make sure it is fully inserted Fig K Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Unlocked Mode Troublingshooting Guide to complete installation Stopper will be in Unlocked mode and removable INSTALL CAM CAP MS68876 Rev 1 2
Download Pdf Manuals
Related Search
Related Contents
ST7110-30A Series User Manual Sanyo UPF234943L User's Manual Mitsubishi Electronics LOSSNAY LGH-100RX4-E User's Manual LaCie USB Speakers Design By Neil Poultan User's Manual Philips 12499ECO User's Manual Citizen Systems Citizen CT-S801 User's Manual Batibook Maison à ossature bois Fascicule 家電延長保証制度保証規約 Copyright © All rights reserved.