1. 15 To set the desired fan speed press one of the four buttons to operate your fan on from low to high speeds 16 To turn the light on and off press and release the LIGHT button To set the light intensity press and hold the LIGHT button The light will turn on at the light intensity previously selected Figure 20 Operation of Your Reverse Switch IMPORTANT Fan installation must be completed including the installation of the fan blades before testing of the controls 17 Restore electrical power to the outlet box by turning the electricity on at the main fuse box 18 All fans are shipped from the factory with the reverse switch positioned to the left circulate air downward If airflow is desired in opposite direction turn your fan OFF and wait for the blades te stop turning then slide the reverse switch to the right position and turn fan on again Figure 21 19 The fan blades will turn in the opposite direction and reverse the airflow Reverse Switch information Season Rotation Direction Switch Position Summer Counter Clockwise Left Winter Clockwise Right 12 FAN LIGHT WALL CONTROL WITH FACE PLATE Figure 19 POWER INDICATOR LIGHT BUTTON ee HIGH TO Low oe i Olf BUTTONS BUTTON f ON OFF SWITCH OFF N Figure 20 REVERSE SWITCH Je Figure 21 Please call Emerson technical support at 1 800 654 3545 if you have any questions about in
2. Figura 11 4 amp WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard A WARNING To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket How to Wire Your Ceiling Fan lf you feel that you do not have enough electrical wiring knowledge or experience have your fan installed by a licensed electrician 44 WARNING To avoid possible electrica shock be sure electricity Is turned off at the main fuse box before wiring NOTE If you are not sure If the outlet box is grounded contact a licensed electrician for advice as It must be grounded for safe operation a WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution agalnst possible electrical shock CAUTION To reduce the risk of electrical shock disconnect the electrical supply circuit before Installing the fan light kit or receiver 1 Position the supply wires to the leit side of the outlet box Figure 12 position the fan wires to the right side Partially insert the remote control receiver flat side up until one end rests on the hanger ball as shown in Figure 12 NOTE Make all wirlng connections using wire connec
3. Figure 13 d Securely connect the fan motor white wire to the receiver white TO MOTOR N wire e Securely connect the fan motor black wire to the receiver red TO MOTOR L wire f Securely connect the fan motor blue wire to the receiver blue FOR LIGHT wire Installation of Glass Shade 1 Instali two 60 watt maximum candelabra base light bulbs included into the light fitter sockets Figure 14 n WARNING Over lamping the fan will result in the light buibs belng automatically shut off Use only 60 watt maximum candelabra light bulbs Turn off the electricity before replacing the light bulbs 2 Place the glass into the opening in the fight kit LIGHT KIT assembly aligning the three flat areas on the top ASSEMBLY edge of the glass with the three light kit tips on the SOCKET 2 light kit assembly and turn the glass bowl clockwise LIGHT KIT until it is secure Figure 15 ASSEMBLY 4 WARNING Figure 14 To avold possible fire hazard do not exceed wattage indicated on the light kit assembly NOTE It is advisable to periodically check that the glass is seated fully clockwise in the light kit assembly LIGHT KIT ASSEMBLY FLAT AREA 3 GLASS BOWL Figure 15 10 80 WATT Max CANDELABRA BASE LIGHT BULB 2 Using Your Ceiling Fan 4s WARNING To avoid possible fire or shock make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling
4. cover and the ceillng 1 Push the wires and connectors up into the outlet box while inserting the receiver fully into the hanger bracket 2 Position the antenna wire on top of the receiver 3 Screw the two threaded studs supplied into the tapped holes in the hanger bracket 4 Lift the ceiling canopy up to the threaded studs and turn until studs protrude through the holes in the ceiling canopy Figure 16 5 Secure the ceiling canopy in place by sliding lockwashers over the threaded studs and installing the two knurled knobs supplied Figure 16 Tighten the knurled knobs securely until the ceiling canopy fits snugly against the ceiling and the hole in the ceiling canopy is clear of the downrod General This control is designed to operate only one ceiling fan 6 Before disconnecting power ensure that the fan is set at the highest speed NOTE Electric connectlons should be in accordance with the Natlonal Electrical Codes and all Local Codes Before starting disconnect power to the circuit at the fuse box or circuit breaker panel 7 Remove the faceplate and screws from the existing wall switch Pull switch out from wall outlet box Figure 17 8 Disconnect wire from existing fan wall switch Setting Operating Frequency of Wall Control Your wall contro has code switches which must be set in one of 32 possible code combinations The five levers numbered 1 2 3 4 and 5 on the switches are factory set
5. in the ON up position Figure 18 Change the switch settings as follows 9 Slide the five switch levers in the wall control to your choice of ON up or down positions Use a ball point pen or small screwdriver and siide the levers firmly up or down 10 When the power is restored after installation push and hold the fan off bution for 3 to 5 seconds to set the code in the receiver CEILING COVER THREADED STUDS 2 LOCKWASHERS 2 KNURLED KNOBS 2 Figure 16 OUTLET SWITCH BOX Figure 17 WALL CONTROL CODE SWITCHES We Figura 18 11 The sixth switch marked ON and is for dimming contro of lights Set switch to ON to allow for dimming of the lights NOTE Use wire connectors supplied to secure electrical connections Using Your Ceiling Fan continued 12 Connect one black wire of wall control to the hot wire Securely connect wires with wire connectors supplied Figure 19 13 Connect one black wire of wall switch to the load black wire in wall box Securely connect wires with wire connector supplied 14 Screw wall control into wall bex and install decorator style faceplate included Leave wall control in OFF mode until fan installation is completed Operation of Your Wall Control Your wall control has full control of your fan and light NOTE Prior to operation of the fan and light from the wall control set the fan speed to HIGH and turn the light ON
6. How to Hang Your Ceiling Fan WARNING CEILING Z The fan must be hung with at least 7 of clearance from floor to blades Figure 9 IE AT rie 4 WARNING The outlet box and joist must be securely mounted and capable of supporting at least 50 Ibs Use only a U L outlet box listed as Acceptable for Fan Support of 22 7 kg 50 Ibs or less a WARNING To reduce the risk of fire electric shock or personal injury mount fan to outiet box marked Acceptable for Fan Support of 22 7 kg 50 Ibs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrictan if in doubt TWO SCREWS SUPPLIED WITH OUTLET BOX 1 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 10 Figure 10 4 WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall NOTE CEILING COVER SU FOR CLARITY pe 2 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was di just attached to the outlet box Figure 11 Be sure y HANGER BALL the groove in the balt is lined up with tab on the nes etintiey hanger bracket Figure 10
7. stallation and operation of this ceiling fan
8. tors supplied Make sure that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire 4 WARNING Check to see that all connections are tight Including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan unill blades are in place Noise and fan damage could result 2 Refer to Figure 12 and 18 and connect the receiver wires to the supply wires and the fan motor wires as follows a Securely connect the green grounding wires from the hanger ball and the hanger bracket to the supply grounding conductor this may be a bare wire or a wire with green insulation b Securely connect the supply white neutral wire to the receiver white AC IN N wire c Securely connect the supply black wire hot wire to the receiver black AC IN L wire SUPPLY WHITE WIRE NEUTRAL RECEIVER WHITE WIRE RECEIVER BLACK WIRE SUPPLY BLACK Qi WIRE HOT a AANS RECEIVER GROUND WIRE ESA Ar 4 RED WIRE RECEIVER BLUE WIRE GREEN GROUND WIRE FROM HANGER BALL ANTENNA GREEN GROUND WIRE rea FROM HANGER BRACKET FAN LAUR 1 1 4 THREADED FAN BLUE WIRE STUD 2 FAN WHITE WIRE Figure 12 STANDARD ON OFF WALL SWITCH OR OPTIONAL a WALL CONTROL _ BLACK VOLT SUPPLY WHITE GROUND fe TWO CONDUCTOR CABLE WITH GROUND GREEN WIRE GROUND FROM HANGER BALL AND HANGER BRACKET

Download Pdf Manuals

image

Related Search

Related Contents

brochure - Robot U  Mode d`emploi Scie murale EX Indice 005  USER'S MANUAL BM155  Belkin F1DW101AEAAU User's Manual  Tripp Lite Modular Serial Adapter Straight-Through Wiring (DB9 F to RJ45 F)  Service Manual Marine  Emerson CSB400 Drawings & Schematics  クラッチセンタースプリング 取扱説明書  Samsung SM-A700F מדריך למשתמש  CAPITULO I - Argentina Compra  