Home

none XXDG-BN-WD Instructions / Assembly

image

Contents

1. Recessed outlet box Figure 3 Outlet box Figure 4
2. install the supplementary mounting means and use only the hardware provided with the fan 12 Warning TO REDUCE THE RISKS OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer B Before installing servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally 13 Warning To reduce the risk of fire electrical shock or personal injury mount to outlet box marked acceptable for fan support and use screws provided with outlet box EE JUNCTION BOX MOUNTING OPTIONS Secure the outlet box directly to the bullding structure Use appropriate fasteners and building materials The outlet box and its support must be able to fully support the moving weight of the fan at least 45 Ibs Use a UL Listed metal outlet box Do not use Figure 1 a plastic outlet box l Figures 1 2 and 3 are examples of different ways to mount the outlet box Note You may need a longer down rod to maintain proper blade clearance when installing on a steep sloped ceiling Fig 3 Outlet box Figure 2 To hang your fan where there is an existing Sasmmuw a4 AN MAXIMUM 24 ANGLE fixture but no ceiling joist you may need an installation hanger bar as shown in Fig 4 Provide strong Ceiling hanger bracket
3. READ AND SAVE THESE INSTRUCTIONS FAN RATING AG 110V 60Hz TOOLS AND MATERIALS REQUIRED Philips screw driver l Standard flat head screw driver N 11 mm wrench 9 Step ladder Wire cutters PACKAGE CONTENTS Unpack your fan and check the contents You should have the following items Hanger bracket assembly Ball Coupling cover Fan motor assembly Metal blades with cages decorative or safety 2 or Wood blades 2 Receiver with 6 wire nuts Transmitter holder 2 mounting screws Allen wrench Package Mounting hardware wood screws 2 screws 2 lock washers 2 washers 2 star washers 2 wire nuts 3 j Downrod oap if blades are metal and accompanied by safety cages see Diagram e i To reduce the risk of injury to persons install fan so that blades are at least 7 0 Ft above the floor in the US and 8 3 Ft 2 5 M above the floor In Canada If blades are metal and accompanied by decorative cages See Diagram e ii or unguarded wooden blades See Diagram e ili To reduce the risk of injury to persons install fan so that blades are at least 10 0 Ft above the floor in the US and 10 0 Ft 3 05 M above the floor in Canada Gir fn e ii FREE e j ji READ AND SAVE THESE SAFETY AND INSTALLATION INSTRUCTIONS Consult a licensed electrician if unsure of any point below mentioned DANGER WARNING CAUTION High voltage and moving parts around motors
4. and motor driven equipment can cause serious or fatal injuries Always disconnect power source at main switch before wiring servicing or cleaning unit Do not rely on fan control device to prevent unexpected start up or electrical shock In addition power supply must have fuses or circuit breakers for short circuit protection All electrical wiring must conform to national and local electrical codes such as NEC OSHA etc Fan should be secure in its electrical grounding to avoid possible electrical shock Fan should not be used in any wet or hazardous location defined by article 500 of the NEG In addition its ambient temperature should not exceed 104 degrees Fahrenheit Power supply should conform to voltage rating of 120V Before applying power visually re inspect the installation Make sure that all ques ane PENE devices are securely In place and all visible screws and bolts are ightened Warning to reduce the risk of fire electrical shock or personal injury mount hanging bracket to outlet box marked Acceptable for fan support and a hanging weight of 45 Lbs Do not mount fan to sheet rock or drywall type materials and use only the screws provided with the outlet box Caution to reduce the risk of injury to persons install fan so that bottom edges of fan blades are to be In Canada to satisfy CSA requirements at least 8 3 Ft 2 5 M above the floor and all objects in room if safety cages are utilized 10 0 F
5. tif safety cages are not utilized In the US to satisfy UL requirements at least 7 0 Ft above the floor and all objects in room if safety cages are utilized 10 0 Ft if safety cages are not utilized To reduce the risk of personal injury do not bend blades or any other part of fan when cleaning Do not insert foreign objects in between rotating tan blades or in space surrounding entire rotating fan unit Fan must be turned off at power at supply source before installation cleaning or servicing 10 Instructions for Supply Connections Conductor of a fan identified as grounded conductor to be connected to a grounded conductor of a power supply conductor of fan identified as ungrounded conductor to be connected to an ungrounded conductor of a power supply conductor of fan identified for equipment grounding to be connected to an equipment grounding conductor After making the wire connections in junction box the splices should be turned eee and pushed carefully into the outlet box The wires should be spread apart with the grounded conductor and the fan grounding conductor on one side of the junction box and the ungrounded conductor on the other side of the outlet box Be sure that all wiring connections are properly insulated from each other and any surrounding metal parts For safety and best operating results we recommend that you have a qualified electrician assemble and install your fan 41 To reduce the risk of personal injury

Download Pdf Manuals

image

Related Search

Related Contents

ステンレスポット PWM-B  MANUAL DEL USUARIO  Origin Storage Internal Notebook Keyboard - Spanish  anual del usuavio vealizado para el Decannto de AdluiviLstvaci6  Lenovo ThinkCentre M93p  V7 Projector Lamp for selected projectors by INFOCUS, GEHA, DUKANE, ANDERS  Nokia N800    CypLite Fiber Laser Cutting Head User Manual  - inotec  

Copyright © All rights reserved.
Failed to retrieve file