Home

Illumine CLI-EMM022067 Installation Guide

image

Contents

1. tre remplac s Consultez un lectricien professionnel en cas de doute
2. Figure 11 How to Hang Your Ceiling Fan continued i NOTE CEILING COVER SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY RANGER BRACKET HANGER BALL Figure 10 DOWNROD ASSEMBLY SUPPLY GROUND WIRE NOTE CEILING COVER BLACK FAN WIRE QMITTED FOR CLARITY WHITE SUPPLY NEUTRAL GREEN WIRE PR raty FROM ANGER BRACKET GREEN WIRE GROUND FROM HANGER BALL WHITE FAN WIRE BLACK SUPPLY HOT THREADED STUD 2 Figura 11 2 Securely connect the fan motor white wire to the supply white neutral wire using wire connector supplied Figure 11 Securely connect the fan motor black wire to the supply black hot wire using wire connector supplied Figure 11 3 After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and the black leads on the other side of the outlet box How to Wire Your Ceiling Fan continued A WARNING Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until blades are in place Noise and fan damage could result AVERTISSEMENT Effectuez une inspection pour vous assurer que toutes les connexions sont bien serr es y compris la connexion de mise la terre et qu aucun fll nu n est visible pr s des connecteurs l exception du fil de mise la
3. LED display will light up to indicate the new speed selected If airflow is desired in the opposite direction press the button on the remote control The fan must be operating at any speed for the reverse button to function The blades will turn in the opposite direction and reverse the airflow in approximately 30 seconds To turn the downlight on or off press and release the button Figure 16 14 Remote Control Procedures continued Accessory Transmitter Dimming Must Be Turned Off 1 The dimming feature On Off switch for all accessory transmitters must be set to the Off position Follow your accessory transmitter installation instructions to set the dimming switch to the Off position 2 Attempting to use the transmitter dimming feature will cause the light kit 1 25A fuse to blow The fuse will need to be replaced to return the fighting to operation Maintenance IMPORTANT CARE INSTRUCTIONS 44 WARNING for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only Do not use water when cleaning your ceiling fan It maintenance that is needed could damage the motor or the blades and create the possibility of an electrical shock 4 AVERTISSEMENT N utilisez pas d eau lorsque vous nettoyez votre ventilateur de plafond Cela risquerait d endommager le moteur ou les lames et de cr er le risque de choc lectrique When cleaning use only a soft brush or lint free cloth to
4. receiver Preset Memory Feature Your Emerson receiver is equipped with a preset memory feature If the AC supply to the receiver is powered through a wall switch when the switch is turned OFF the control will remember the light intensity and fan speed When the switch is turned back ON the light and fan will resume operation as they were prior to the switch being turned OFF Installation of Battery 1 Remove the battery cover by pressing firmly below the arrow and sliding the cover off the control Figure 14 2 Install two AAA alkaline batteries and reinstall the battery cover CODE SWITCHES BATTERY COMPARTMENT REMOTE CONTROL COVER Figure 14 Installation of Storage Bracket for Remote Control A storage bracket is provided for holding your remote control when not in use lf you desire to use the bracket install it on a wall that is away from excess heat or humidity Figure 15 TO INSTALL BRACKET TO WALL SLIDE THE GOVER UP TO EXPOSE THE SCREW HOLES FOR INSTALLATION WALL BRAGKET SCREW T HOLES 2 i Figure 15 13 Remote Control Procedures continued Setting Operating Frequency of Remote Control Your remote control has code switches which must be set in one of 32 possible code combinations Figure 14 The five levers numbered 1 2 3 4 and 5 on the switches are factory set in the ON up position Change the switch settings as follows Figure 16 1 Slide the five switch levers in the
5. the bulb pins into the light socket holes Install the remaining three GU24 fluorescent bulbs in the same manner Place the glass bowl into the opening in the lower housing assembly aligning the three flat areas on the top edge of the glass with the three raised dimples on the lower housing assembly and turn the glass bowl clockwise until it stops Figure 13 RAISED DIMPLES OF LIGHT KIT HOUSING FLOURESCENT LAMP PLUG 4 FLAT AREA OF GLASS BOWL NOTE periodically check that the glass bowl is seated fully clockwise in the lower housing assembly Figure 13 12 Remote Control Procedures General Your Emerson Ceiling Fan Light Remote Control consists of hand held transmitter and a receiver which is mounted under the fan ceiling cover The remote control is designed to separately control your ceiling fan speed and light intensity The remote control transmitter is powered by two AAA alkaline batteries included To prevent possible damage if the batteries should leak be sure to remove the batteries when the conirol is not to be used for an extended period of time Code switches in the transmitter and receiver may be set In 32 different positions If your fan and light go on and off without using your control you may be getting interference from other remote units such as garage door openers car alarms or security systems To remedy this situations simply change the combination code in your transmitter and
6. How to Hang Your Ceiling Fan 4 WARNING CELING The fan must be hung with at least 7 of clearance from floor to blades Figure 8 n AVERTISSEMENT Le ventilateur doit tre suspendu de fa on que les pales FLOOR solent au moins a sept pleds 2 10 m du sol Figure 8 Figure 8 4 WARNING The outlet box and Joist must be securely mounted and capable of supporting at least 50 Ibs Use only a U L outlet box listed as Acceptable for Fan Support SUSPLIED WITH 4 AVERTISSEMENT OUTLET BOX Le bo tier de prises de courant et la poutrelle dolvent avoir t mont es solidement et tre capables de Figure 9 supporter au moins 50 Ibs 22 5 kg Utilisez seulement un bo tier de prises de courant homologu U L comportant les termes Acceptable pour le A WARNING raccordement d un ventilateur Hanger bracket must seat firmly against outlet box If the outlet box Is recessed remove wal board until bracket contacts box If bracket and or outlet box are A WARNING not securely attached the fan could wobble or fall To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with n AVERTISSEMENT outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan Le support de suspension doit reposer fermement support and may need to be replaced Consult a contre le boitier de prises de cou
7. avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Accessories WARNING To reduce the risk of fire electric shock or personal SW605 Wall Transmitter injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplled with SR650 Wall Handheld Transmitter outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan WARNING support and may need to be replaced Consult a qualified electrician if in doubt The use of any other control not specifically approved for this fan could result in fire shock and personal injury 1 Downrod Extension Kits see store or catalog 2 Accessory Ceiling Fan Controls SR600 Handheld Transmitter a AVERTISSEMENT Pour r duire le risque d Incendie de choc lectrique ou Aa AVERTISSEMENT de blessures ne montez le ventilateur que dans un bo tier de prises de courant comportant les termes L utilisation de toute autre commande non approuv e sp cifiquement pour ce ventilateur risquerait de causer un incendie une d charge lectrique ou des blessures 15 Acceptable pour le raccordement d un ventilateur et utilisez les vis fournies avec le bo tier La plupart des bo tiers de prises de courant utills s couramment pour le raccordement de luminaires ne sont pas acceptables pour le raccordement de ventilateurs et devront peut tre
8. rant Si le boitier de qualified electrician If in doubt prises de courant est encastr retirez le panneau de rev tement jusqu a ce que le support entre en contact i avec le bo tier SI le support et ou te bo tier ne sont pas Aa AVERTISSEMENT solidement attach s le ventilateur risqueralt d oscilter ou m me de tomber Pour r duire le risque d incendie de choc lectrique ou de blessures montez le ventilateur sur un bo tier de prises de courant comportant les termes Acceptable 2 Carefully lift the fan and seat the hanger pour le raccordement d un ventilateur et utilisez les ball downrod assembly on the hanger bracket that vis fournies avec le boitier La plupart des boitiers de was just attached to the outlet box Figure 10 Be prises de courant utilis s couramment pour le sure the groove in the ball is lined up with tab on raccordement de luminaires ne sont pas acceptables the hanger bracket Figure 9 pour le raccordement de ventilateurs et devront peut tre tre remplac s Consultez un lectricien professionnel en cas de doute 4 WARNING AT LEAST 7 Failure to seat tab in groove could cause damage to 1 Securely attach the hanger bracket to the outlet box electrical wires and possible shock or fire hazard using the two screws supplied with the outlet box Figure 9 a AVERTISSEMENT Si vous n installez pas la languette dans la rainure vous risquez d endommager les fils lectriques et de ca
9. remote control to your choice of ON up or down positions Use a ball point pen or small screwdriver and slide the levers firmly up or down 2 Restore electrical power to the ceiling fan at the circuit breaker panel or fuse box 3 Within 1 minute of restoring electricity push and hold the remote control OFF button for 3 to 5 seconds to set the code in the receiver The fan s lights will blink several times to confirm the fan is programmed NOTE The ceiling fan receiver will not respond to transmitter commands if the transmitter s frequency switch settings are changed without reprogramming the receiver Program the receiver to the new frequency by repeating the Setting Operating Frequency of Remote Control and High Speed Conditioning instructions High Speed Conditioning IMPORTANT The following steps must be completed immediately following the frequency programming of the ceiling fan 1 Press the speed button until all 6 LED indicators are lit Let the fan operate on high speed for 2 minutes without interruption 2 After 2 minutes press the reverse button and allow the fan to operate uninterupted for 2 minutes at high speed 3 High speed conditioning is now complete Operating Your Ceiling Fan To turn on or shut off the ceiling fan press and release the button To set the desired fan speed press the button to decrease the speed and the to increase the speed The
10. terre Ne mettez pas le ventilateur en marche avant que les pales ne soient leur place Ceci causeralt un fonctionnement tr s bruyant et risquerait d endommager le ventilateur Screw the two threaded studs supplied into the tapped holes in the hanger bracket Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure 12 Secure the ceiling cover in place by sliding lockwashers over the threaded studs and Installing the two knurled knobs supplied Figure 12 Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod CEILING COVER THREADED STUD LOCKWASHERS 2 KNURLED KNOB Figure 12 To avoid possible fire or shock make sure that the electrical wires are completely Inside the outlet box and not pinched between the ceiling cover and the ceiling AVERTISSEMENT Pour ne pas risquer d incendie ou de choc lectrique assurez vous que les fils lectriques sont compl tement l int rieur du bo tier de prises de courant et qu ils ne sont pas pinc s entre le rev tement de plafond et le plafond Installing Lamps and Glass Globe Carefully position one of the GU24 fluorescent bulbs supplied into the light fitter socket aligning the two pins on the bottom of the bulb into the socket holes Twist the bulb clockwise approximately 1 16 turn to engage
11. user ventuellement une d charge lectrique ou un incendie 10 44 WARNING To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket 44 AVERTISSEMENT Pour ne pas risquer d incendie ou de choc lectrique ne pincez pas les fils entre l ensemble de tige cylindre de suspension et le support If you feel that you do not have enough electrical wiring knowledge or experience have your fan installed by a licensed electrician 4 WARNING To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring NOTE If you are not sure if the outlet box is grounded contact a licensed electrician for advice as it must be grounded for safe operation 4 AVERTISSEMENT Pour ne pas risquer de choc lectrique assurez vous que l lectricit est coup e au niveau du disjoncteur bo tier de fusibles avant de r aliser le raccordement REMARQUE si vous ne savez pas vraiment si le bo tler de prises de courant est mis la terre contactez un lectricien professionnel pour lui demander conseil te ventilateur doit tre mis la terre pour pouvoir fonctionner sans danger 1 Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket io the grounding conductor of supply this may be a bare wire or wire with green colored insulation Securely connect wires with wire connectors supplied