1. use soft brushes or cloths to prevent scratching Cleaning products may damage the finishes Operation Maintenance amp Cleaning continued Reverse Switch To switch the direction of air flow move the reverse switch to the opposite position You will need to remove the light kit glass to do so Hunter fans have the power to cut your cooling costs up to 40 Beat the High Cost of Cooling The air movement created by a Hunter ceiling fan lets you set your thermostat higher and still stay comfortable Every degree you raise the thermostat saves up to 7 on energy costs So you can cut back on expensive air conditioning and save up to 40 on cooling In winter your Hunter fan recirculates warm air and saves up to 10 on heating bills On average at low speed settings Your savings may vary based on climate building type and thermostat setting Save Energy and Money While Protecting the Environment Congratulations You re saving energy and money while protecting the environment by purchasing this ENERGY STAR qualified Hunter ceiling fan With this purchase you are doing your part to protect the environment Your new ceiling fan has earned the ENERGY STAR label because it meets high energy efficiency specifications set by the Environmental Protection Agency EPA ENERGY STAR labeled ceiling fans save energy because they have more efficient fan motors and air delivery due to more aerodynamic blade configurations C
2. Longer Downrod most common If you have a flat ceiling Hang your fan by a standard downrod included Mounting Options Use Standard Mounting or Low Profile Mounting to hang the fan from a flat ceiling Use Angled Mounting to hang the fan from a vaulted or angled ceiling 4 34 O CEILING WALL OPTION 1 Standard Mounting OPTION 2 Angled Mounting 2 3 SLIDE toward ceiling PLACE against wall 1 FOLD on dotted line 34 Use the three steps below to determine if your ceiling angle is greater than 34 Support Structure Ceiling Outlet Box required Angled Mounting Style Standard Mounting Style Support Structure Ceiling Outlet Box required M0074 01 05 14 14 Hunter Fan Company www HunterFan com www HunterFan com 1 888 830 1326 1 888 830 1326 www HunterFan com Ceiling Bracket 5 Refer to warning w 1 on pg 2 To avoid possible electrical shock before installing your fan disconnect the power by turning off the circuit breakers to the outlet box associated with the wall switch location For angled ceilings point opening toward peak If you are unable to do this call Technical Support at 1 888 830 1326 Make sure all four bumpers are still attached Use wood screws included when securing to support structure with approved electrical outlet box Drill 9 64 pilot holes in support structure to aid in securing
3. ceiling bracket with hardware found in the hardware bag Use machine screws provided with outlet box when securing to existing ceiling fan rated outlet box Make sure it is securely installed and is acceptable for fan support of 31 8 kg 70 lbs or less OFF Turn Power 5 M0074 01 05 14 14 Hunter Fan Company www HunterFan com 1 888 830 1326 1 888 830 1326 www HunterFan com Preparation D I S C A R D K E E P Remove the shipping blocks from the motor Save the screws They will be needed for blade iron installation Note Some fans will have a shipping ring instead of shipping blocks Please remove the ring and save the screws Time Saver Tip Get a helper to insert grommets found in the hardware bag into the blades while you re doing the next couple of steps If you are installing multiple remote controlled fans on the same circuit breaker you may need to perform a few extra steps to prevent interference or faulty operation of your remote controls Go to www HunterFan com FAQs and click How do I properly install multiple remote controlled fans for more information 6 M0074 01 05 14 14 Hunter Fan Company 1 888 830 1326 Downrod Slid e Slid e 1 2 3 4 5 6 7 8 9 10 Sold Separately Included Longer Downrod for angled ceilings or ceilings 10 or higher Shorter Downrod for fans ins
4. e with national and local electrical codes ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician c 2 Use only Hunter replacement parts This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications www HunterFan com 1 888 830 1326 Tools Needed Ladder Power Drill optional 9 64 Drill Bit optional Screwdrivers Pliers Wire Strippers If mounting to a support structure you will also need these tools 3 M0074 01 05 14 14 Hunter Fan Company www HunterFan com 1 888 830 1326 4 M0074 01 05 14 14 Hunter Fan Company 1 866 268 1936 If you have an angled ceiling 1 You will need a longer downrod sold separately 2 If your ceiling angle is greater than 34 you will also need an Angled Mounting Kit sold separately Guide Touches BOTH Ceiling amp Wall S I T U A T I O N 1 Guide Touches Wall but NOT Ceiling S I T U A T I O N 2 You need BOTH a Longer Downrod amp an Angled Mounting Kit You need ONLY a
5. eiling fan models bearing the ENERGY STAR label move air 14 20 more efficiently than typical ceiling fan models For more information on ENERGY STAR visit www energystar gov www HunterFan com 1 888 830 1326 M0074 01 05 14 14 Hunter Fan Company 17 Troubleshooting Fan doesn t work Make sure power switch is on Pull the pull chain to make sure it is on Push the motor reversing switch firmly left or right to ensure that it is engaged Check the circuit breaker to ensure the power is turned on Make sure the blades spin freely Turn off power from the circuit breaker then loosen the canopy and check all the connections according to the wiring diagram on page 10 Make sure the battery is working Check the plug connection in the switch housing Excessive wobbling Tighten all of the blade and blade iron screws until they are snug Turn the power off support the fan carefully and check that the hanger ball is properly seated Use the provided balancing kit and instructions to balance the fan Remote control of fan is erratic Make sure the battery is installed correctly Install a fresh battery Transmitter only works when held at close range Change battery Noisy operation Tighten the blade and blade iron screws until they are snug Check to see if any of the blades are cracked I
6. f so replace all of the blades If you have multiple remotes or multiple remote controlled fans installed on the same circuit breaker and you are experiencing interference or faulty operation of your remote controls please go to www HunterFan com FAQs and click How do I properly install multiple remote controlled fans for information on how to correct this issue
7. lade to the floor Select a downrod length Assess ceiling angle Must be able to secure the fan to building structure or fan rated outlet box 1 2 3 Standard Downrod for ceilings 8 10 feet high Shorter Downrod for fans installed close to ceiling Longer Downrod for ceilings 10 feet or higher 2 Ceiling angles greater than 34 will require an Angled Mounting Kit See page 4 for details Read and Save These Instructions This product conforms to UL Standard 507 WARNINGS CAUTIONS w 1 To reduce the risk of fire electrical shock or personal injury mount fan directly from building structure and or an outlet box marked acceptable for fan support of 70 lbs 31 8 kg and use the mounting screws provided with the outlet box w 2 To avoid possible electrical shock before installing or servicing your fan disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the service panel w 3 To reduce the risk of fire electrical shock or motor damage use only Hunter Speed Controls w 4 To reduce the risk of personal injury do not bend the blade brackets when installing the blade brackets balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades c 1 All wiring must be in accordanc
8. of the upper switch housing then wrap keyhole slots around the screws and twist counterclockwise Screw two housing assembly screws from the hardware bag halfway into the motor housing It does not matter which two screw holes you choose Insert the third screw found in the hardware bag into place and then tighten all three screws Make sure the upper switch housing is securely attached to the mounting plate Failure to properly secure all 3 assembly screws could result in the switch housing fixture falling Switch Housing 13 M0074 01 05 14 14 Hunter Fan Company www HunterFan com 1 888 830 1326 Switch Housing continued Make sure the lower switch housing is securely attached to the upper switch housing Failure to properly secure all three assembly screws could result in the switch housing falling Connect the plugs from the upper and lower switch housings Make sure to line up the colored markings on the connectors Lift the lower switch housing until its screw holes are aligned with the screw holes in the upper switch housing Install the three switch housing screws found in the hardware bag Tighten all three screws CONGRATUALTIONS YOU RE DONE 14 M0074 01 05 14 14 Hunter Fan Company www HunterFan com 1 888 830 1326 Within 3 minutes of restoring power to the fan press both the Fan Off button and the High button for at least 4 seconds Your fan
9. res apart with the grounded wires on one side of the outlet box and the ungrounded wires on the other side of the outlet box Refer to CAUTION c 1 on pg 2 Using an orange wire connector from the hardware bag connect the 3 grounding wires green green yellow stripe or bare copper coming from the ceiling downrod and hanging bracket F R O M R E C E I V E R F R O M C E I L I N G F R O M C E I L I N G B R A C K E T green yellow stripe grounding green yellow stripe green yellow stripe black blue yellow blue Note To connect the wires hold the bare metal leads together and place a wire connector over them then twist clockwise until tight Using the orange wire connectors from the remote control hardware bag connect the blue wire from the receiver to the blue wire or possibly black with white stripe wire from the fan Connect the yellow wire from the receiver to the black wire from the fan F R O M F A N F R O M F A N F R O M R E C E I V E R Using the orange wire connectors from the hardware bag connect the black wire ungrounded from the ceiling to the black wire from the receiver Connect the white wire grounded from the ceiling to both the whi
10. talled close to ceiling Standard Downrod for ceilings 8 10 high Option 1 Option 2 Option 3 skip to next page If you need a different downrod length follow these steps Steps 1 5 to remove standard downrod pipe Steps 6 10 to reassemble with new pipe Included pre assembled www HunterFan com 7 M0074 01 05 14 14 Hunter Fan Company KEEP 8 3 8 C U T amp S T R I P not to scale Remove the pre installed setscrew so that the downrod can be inserted Hand tighten the downrod at least 4 5 full turns until it stops The wires can be cut but leave at least 8 extending from the top of the downrod Downrod continued 8 3 8 Tighten the setscrew with pliers DO NOT HAND TIGHTEN If the setscrew is not tightened securely the fan may fall K E E P 1 888 830 1326 www HunterFan com 8 M0074 01 05 14 14 Hunter Fan Company 1 888 830 1326 9 M0074 01 05 14 14 Hunter Fan Company www HunterFan com Downrod continued DO NOT PICK THE FAN UP BY THE CANOPY OR WIRES Place the downrod ball into the slot in the ceiling bracket Put the wires and downrod through the canopy Let the canopy sit loosely on top of the fan www HunterFan com 1 888 830 1326 Wiring Turn the splices upward and push them carefully back through the hanger bracket into the outlet box Spread the wi
11. te wire from the receiver and the white wire from the fan F R O M C E I L I N G black ungrounded white grounded black white F R O M F A N white 10 M0074 01 05 14 14 Hunter Fan Company www HunterFan com 1 888 830 1326 11 M0074 01 05 14 14 Hunter Fan Company Canopy Lift the canopy into place so that the screw holes are aligned Position the canopy so that when lifted into place the canopy fits into the hanging bracket as shown Screw Holes Insert the two canopy screws found in the hardware bag Note Fan style may vary www HunterFan com 1 888 830 1326 M0074 01 05 14 14 Hunter Fan Company Blades Your blades are shielded with Dust Armor which is a nanotechnology coating that repels dust For cleaning the fan use soft brushes or cloths to prevent scratching Cleaning agents may damage the finishes 12 Insert grommets found in the hardware bag into the holes in the blades then secure each blade to a blade iron with screws found in the hardware bag Remember the screws that you kept after removing the shipping blocks page 6 You need them for this step Lightly attach the blade irons to the motor with the blade iron armature screws then securely tighten after both screws are attached www HunterFan com 1 888 830 1326 Feed the wire plug through the center hole
12. will turn on low to indicate successful syncing If it does not turn off power to your fan wait 1 minute then try again If using the transmitter with multiple fans repeat this process for each fan Note The remote must be paired before the fan will operate Fan Off High To install the transmitter cradle remove the two screws holding your switch cover plate Do not remove the cover plate Orient the cradle by lining up the two mounting holes with those on the cover plate Insert and tighten the screws Do not over tighten The Fan Off button only turns the fan off To turn the fan on press one of the fan speed buttons High Medium Low Operation Maintenance amp Cleaning ON Turn Power To access the battery compartment remove the small Phillips head screw that secures the battery door to the transmitter assembly The battery should be installed with the positive side up Replace with a CR2032 battery when necessary Phillips Head Screw Battery Door ooo oo o Low Medium High Fan Off If you are installing multiple remote controlled fans on the same circuit breaker go to www HunterFan com FAQs and click How do I properly install multiple remote controlled fans for more information 15 M0074 01 05 14 14 Hunter Fan Company www HunterFan com 1 888 830 1326 16 M0074 01 05 14 14 Hunter Fan Company 16 For cleaning the fan
13. www HunterFan com 1 888 830 1326 PAG E 7 PAG E 13 PAG E 10 PAG E 5 PAG E 6 30 inches 7 feet PAG E 2 What to Expect with Your Installation Ceiling Bracket Ladder PAG E 3 Tools Needed Wiring Canopy Operation Maintenance amp Cleaning Blades Troubleshooting Downrod Switch Housing Preparation Table of Contents PAG E 11 PAG E 12 PAG E 4 Mounting Options PAG E 15 PAG E 17 Congratulations on purchasing your new Hunter ceiling fan It will provide comfort and performance in your home or office for many years This installation and operation manual contains complete instructions for installing and operating your fan We are proud of our work and appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world To register your fan please visit www HunterFan com register Save your receipt for proof of purchase 1 M0074 01 05 14 14 Hunter Fan Company www HunterFan com 1 888 830 1326 M0074 01 05 14 14 Hunter Fan Company 1 888 830 1326 1 888 830 1326 What to Expect with Your Installation Know your wiring If you are unfamiliar with wiring use a qualified electrician You may need a friend to help you Check box to see fan weight Assess location 30 inches from blade tip to nearest wall or obstruction 7 feet from bottom edge of b
Download Pdf Manuals
Related Search
Related Contents
Marmitek FD10 MODO DE EMPLEO Behringer DX626 Quick Start Guide XCELLENCE SERIES Samsung 197 Lts Nevera una puerta gris RA21PD Manual de Usuario iStream 2 Issue 3 - Europe 860E Users Manual User Manual - Billiger.de Guide pratique Druck DPI 800/802 - GE Measurement & Control Functional Specifications for an Infant Monitoring System Copyright © All rights reserved.