Home

ViaVolt V48 Use and Care Manual

image

Contents

1. the unit is unplugged and cool before replacing any bulbs or otherwise handling the lamp or its components 5 Make sure you have the correct lamp for your ballast the wattage on the lamp must match the ballast wattage in order for it to operate effectively 6 When using a 240V plug use the one included with the unit or purchased at a retailer DO NOT make any changes to the power cord This will void the warranty and may result in serious injury or death POWER USAGE A light system will increase your average electricity bill by 10 to 20 a month the exact amount will vary based on the size of the system the prevailing rates for electricity in your area and the number of hours you choose to operate it To figure how much amperage your unit is using simply use the following formula Wattage divided by Voltage Amperage The average household circuit breaker is rated at 15 amps In other words if the total amperage drawn from that circuit exceeds 15 amps the circuit breaker will trip Most rooms share one or perhaps two circuits per room If you have a 1000 watt unit running off a 120 volt circuit it will draw approximately 9 amps 1000 watts 110 volts 9 1 amps Example If your charge for 1 kilowatt hour in your area is 6 cents per kW h a 1000 watt fixture will use 1 1 kW per hour Lets say you burn your light 14 hours per day 14 hours x 066 06 x 1 1 92 cents per day If you burn it 30 days per month the cost w
2. But first make sure to check for excessive heat at the canopy of your plants Place your hand directly over your plants If your hand gets hot you need to move your lamp up higher If the light source is too close to your plants the leaves will burn Be sure to adjust the height of your light system as your plants grow Air cooled reflectors like the Air Cooled Deluxe allow you to place higher wattage lamps closer to plants with minimal heat by attaching an inline fan T5 fluorescent fixtures can be placed closer to the plant canopy than H I D fixtures because they produce little to no heat gt Light Coverage aL Recomendad distanoa fram plants H I D Average Coverage Area by Wattage 0 100 175 watts cover about a 2 x 2 area O 250 watts cover about a 3 x 3 area 0 400 watts cover about a 4 x 4 area O 600 watts cover about a 6 5 x 6 5 area O 1000 watts covers about a 8 x 8 area TROUBLESHOOTING GUIDE If Your Fixture Does Not Work 1 Check the electrical source Make sure the unit is plugged in and that the breaker is not tripped 2 If the electrical source is fine unplug the unit from the power source before inspecting the lamp Then check the lamp Make sure the lamp is inserted correctly and is not visibly damaged 3 For T5 Fluorescent fixtures Check to ensure the lamps are properly locked into the socket Turn lamps 1 4 turn in either direction to confirm 4 Try another lamp if you have one Make sure
3. URCHASE OFTHIS PRODUCT WHETHER SUCH CLAIM IS BASED ON WARRANTY CONTRACT TORT INCLUDING NEGLIGENCE OR STRICT LIABILITY AND RETURN FORM Include the following if returning a Proof of purchase o This completed form o RMA on the outside of the box o Extended warranty receipt INCLUDING CLAIMS FOR PERSONAL INJURY OR DEATH OR OTHERWISE IN NO EVENT WILLTHE COLLECTIVE LIABILITY OF VIAVOLT OR ITS MANUFACTURER EXCEED THE AMOUNT YOU HAVE PAID FORTHE PURCHASE OF THE PRODUCT OUT OF WHICH LIABILITY AROSE THESE LIMITATIONS SHALL APPLY NOTWITHSTANDING ANY FAILURE OF ESSENTIAL PURPOSE OF ANY REMEDY SOME STATES AND OR JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SOTHE ABOVE EXCLUSION MAY NOT APPLY TO YOU WARRANTY SERVICE If the product will not work after you have read the troubleshooting guide and practiced the troubleshooting options you are advised to return the ViaVolt light system to the retailer you purchased it from The dealer will be able to examine the light and test its components If they are not able to repair the light they will return it to us for examination and repair replacement Do not attempt to repair any product on your own as serious injury or death may result If the retailer is not able to help you and the light is still under manufacturers warranty you may contact us for technical support In some cases you will be issued an RMA return merchandise aut
4. WARRANTY INFORMATION ViaVolt warrants the original purchaser of this product against defects in material and workmanship under normal use for 2 years on the ViaVolt Ballast and 2 years on the ViaVolt T5 Fluorescent System from the date of purchase During the warranty period ViaVolt will at our option and without charge repair or replace this product if the unit or any of it s components fail or malfunction VIAVOLT AND ITS MANUFACTURER EXPRESSLY DISCLAIM ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR USE AND ALL OTHER OBLIGATIONS OR LIABILITIES ONTHE PART OFTHE SELLER EXCEPT WHERE PROHIBITED BY APPLICABLE LAW THIS WARRANTY SHALL NOT APPLY TOTHIS PRODUCT OR ANY PART THEREOF WHICH HAS BEEN USED OTHER THAN IN ACCORDANCE WITHTHE MANUFACTURER S INSTRUCTIONS OF USE DAMAGED BY ACCIDENT ABUSE MISUSE MODIFICATION NEGLIGENCE ALTERATION OR MISAPPLICATION VIAVOLT MAKES NO WARRANTY WHATSOEVER WITH RESPECT TO ACCESSORIES OR PARTS NOT SUPPLIED BY VIAVOLT THIS WARRANTY SHALL APPLY ONLY TOTHE UNITED STATES INCLUDING ALASKA HAWAII AND TERRITORIES OFTHE UNITED STATES AND CANADA LIMITATION OF LIABILITY TOTHE MAXIMUM EXTENT ALLOWED BY LAW VIAVOLT AND ITS MANUFACTURER SHALL NOT BE LIABLE FOR ANY SPECIAL CONSEQUENTIAL EXEMPLARY OR INCIDENTAL DAMAGES INCLUDING LOST OR ANTICIPATED REVENUES OR PROFITS RELATINGTO THE SAME ARISING FROM ANY CLAIM RELATING TO THE P
5. ath for which ViaVolt s manufacturer and resellers expressly disclaim any and all liability 000 All American Parts ViaVolt MULTI VOLT REMOTE BALLAST SETUP 1 Remove the ballast from its box along with all additional parts 2 The ViaVolt ballast system comes with a 120 volt power cord and a voltage selector plate Set the voltage selector plate to the 120 volt option in order to utilize the provided cord To change the voltage simply pull the warning plate out and twist 180 Fig 1 and 2 To use the 240 volt option you must purchase the 240 volt power cord separately 3 Securely screw your lamp into the socket Then make sure the lamp cord is plugged into the ballast 4 Power up the system by plugging the power cord into the proper NEMA configured receptacle 5 You should use a properly rated cord 120 or 240 volt for the power type that you are using or you will short circuit the ballast and void the warranty a 3 A ayi ie s i a pee wey aw EETA TFT SEGUE Ti Faj ININE YM Fig 2 ViaVolt T5 FLUORESCENT SETUP 1 Remove theT5 system from its box along with all additional parts 2 Hang the unit to a secure surface using the V hangers provided optional light hanger systems can be purchased separately Never stand underneath the unit 3 Install lamps examine the label to determine the correct lamp into the system Insert both ends of the lamp into the lamp sockets a
6. horization number to return the unit for factory repair Complete the warranty form below and return the light with all original packaging your receipt of purchase and a valid RMA to the address below Please pack and ship the light in its original packaging If it is damaged in shipment we cannot be responsible and the warranty may be voided Once we receive RMA package it will be repaired or replaced and shipped back to you Please note if an additional warranty was purchased and include the extended warranty sales receipt with your return Return Merchandise Authorization Number Required Contact Name Address Phone Email Address Please give a brief description of your technical issue SEND TO Viagrow 2561 West Point Ave College Park GA 30337 678 510 0032 All American Parts IMPORTANT PRODUCT INFORMATION READ IMMEDIATELY SAFETY FIRST Failure to observe the following safety warnings may result in serious injury or death Use all ViaVolt products only as directed Failure to observe these safety warnings will result in a waiver of any and all liability on the part of ViaVolt its manufacturer and resellers and will void all warranties to the extent permitted by law WARNINGS AND INSTRUCTIONS FOR USE 0 DO NOT plug or unplug a lamp cord while the ballast is turned on O ALWAYS unplug the ballast from the power source before connecting or disconnecting any lighting device to ballast
7. ill be 30 x 92 per day 27 60 per month If you burn 400 watt lamps you will use 46 46 of 1 kW hour So it will cost 06 kW x 46 028 or 2 8 cents per hour x 14 hours per day 39 cents per day x 30 days per month 11 70 month 1000w fixtures use 1100 watts per hour 400 watt fixtures use 460 watts per hour 250 watt fixtures use 295 watts per hour and 175 watt fixtures use 210 watts per hour The reason the ballast uses more watts than the lamp rating is because of ballast inefficiency and heat loss RETURNING UNITS Please contact your retail store for returns Keep all original packaging and your receipt all returns need to be in the original packaging in order to avoid product damage during shipping Any damage to products not in their original packaging will not be covered under warranty If returning by retail store is not an option please contact ViaVolt to obtain an RA
8. moving ballast or otherwise touching or handling ballast or its components O DO NOT use with generators Warranty will be voided DO NOT hang by power cord or lamp cord NEVER stand beneath the ballast DO NOT make contact with the socket interior while the power is switched on O NEVER put hands or any other objects in the interior of the ballast O DO NOT operate this or any lighting system in wet areas O DO NOT plug this system into a receptacle other than what is instructed on the ballast O DO NOT open or rewire the components of the light system It will void the warranty and may Cause serious injury or death O f any part of the lamp is damaged replace lamp immediately O Disconnect the unit from a power source before replacing lamps or any other parts O When replacing lamps make sure the lamp has had time to cool before touching O Make sure power cord and lamp cord are connected securely to the unit O Keep away from children O Glass is required for reflectors using metal halide MH lamps for UL listing to apply Glass is not required for high pressure sodium HPS lamps to be UL listed O Always use a three prong timer rated for 15 amps or more with light systems 0 Do not operate lamps that are a different wattage than the ballast specifies O Read all instructions completely before attempting to power on unit Failure to follow the warnings and instructions for use may result in serious injury or de
9. nd rotate the lamp 90 in either direction Fig 3 4 ViaVolt T5 units can be daisy chained together Do not exceed 7 5 amps on any fixtures chained together Do not daisy chain more fixtures than what is recommended Chaining more fixtures together than recommended will void the warranty Always unplug T5 systems from the power source prior to moving connecting chaining disconnecting or otherwise handling lighting systems 5 Finally connect T5 system to a power source LANIP INFORMATION Proper Lamp Care Lamps should be replaced yearly to maintain optimum lumen output If a lamp fails to reach full brightness please contact your retailer to purchase a new lamp Fluorescent Fixtures If there are lamps that will not fire try swapping them for lamps from other sockets that are working to determine if you need lamp replacement Never remove install or swap bulbs while unit is connected to a power source ABOUT HID AND T5 FLUORESCENT LANIPS O0 It may take HIDs orT5 fluorescents 10 15 minutes to reach full brightness O HID lights will decrease in output during the life of the lamp O During an HID lamp s first several uses intensity of the light fluctuates but afterwards it will continue at an even output for the remainder of its life with a gradual degredation REFLECTOR MOUNTING Generally the proper hanging height of an H I D lamp should be somewhere between 12 48 depending on the wattage