Home
Dale Tiffany FTH10016 Instructions / Assembly
Contents
1. 5 SPRINGDALE ASSEMBLY INSTRUCTIONS Important Safety Instructions Power at the Fuse Box should be disconected before installing this fixture The Fixture ground wire bare or green installed wire is NOT connected to current carrying supply wires The insulation on any of the wires must not be damaged during installation No rough or sharp edges are in contact with any of the wires Fixture wires are connected to the proper house supply wires We recommend professional installation by a licensed electrician Do not use light bulb s with wattage greater than those APX WT 10 LBS specified for this fixture Power is off when installing light Listed bulb s into the fixture Insure the outlet box is well mounted to the building structure and will be able to support the weight of the fixture The use of a crossbar is recommended O Read directions and follow steps 1 13 2 Carefully unpack and layout the parts as shown in illustration and read all instructions before starting 3 Follow numbered steps on diagram Screw Crossbar 3 to Ceiling Outlet Box with Ceiling Screws 4 attach Threaded Rod 5 to Crossbar 3 Screw Nut 6 and Loop 7 to Threaded Rod 5 6 4 Raise Canopy 8 and tighten Loop Collar 9 connect fixture 0 chain 10 to the loop with desire length of chain 11 12 t 5 After connecting chain loosen Loop Collar 9 and low
2. FT H 1 0 0 1 6 Listed No debe haber bordos rugosos o filosos en contacto con alguno de los cables N Los cables de la l mpara se deben conectar a los cables aproximada 10 libras de suministro correctos de la casa Recomendamos instalaci n profesional por un electricista licenciado No utilice bombillas de un vataje mayor al especificado de las bombillas para esta l mpara El suministro debe O Lea las instrucciones y siga los pasos 1 13 estar cortado durante la instalaci n en la l mpara 2 Desempaquete y presente cuidadosamente las piezas 3 4 6 Aseg rese de que la caja de salida est bien montada en la estructura de la construcci n y de que pueda sostener Lebel ite p 5 el peso de la l mpara El uso de una abrazadera de montage a las indicaciones de la ilustraci n es recomendado Seguir los pasos en el diagrama atornille la abrazadera 3 a la caja el ctrica con los tornillos 4 colocar la tuerca roscada 5 ST a la abrazadera de montage 3 colocar la tuerca 6 y el enganche de anillo 7 a la tuerca roscada 5 Levantar la base 8 para apretar el enganche de anillo 9 conectar la cadena de la l mpara 10 al enganche de anillo colocando la cadena al tama o que se desea 11 12 Despues de conectar la cadena suelta al enganche de anillo 9 y bajar la base 8 sobre la cadena Colocar las cables de la l mpara 13 atraves de la cadena G iss el enganche de anillo la base el o
3. H TIN Brazo de la FTH10016 ADVERTENCIAS PARA EVITAR EL RIESGO DE Tubo Perillas DESCARGA ELECTRICA ASEGURESE DE DESCONECTAR aia LA ALIMENTACI N DURANTE LA INSTALACI N O X SERVICIO DE ESTE APARATO 9 Levante la l mpara al techo y entrelace el cable el ctrico a trav s del tubo roscado en el soporte de montaje Totaly 10 Rosque el tubo en la base de la l mpara y su remate 11 Rosque los brazos de la l mpara en el ensamble de la l mpara Pantalla y la base de la l mpara con las perillas decorativas 12 Coloque la pantalla en el portal mpara y f jela con la tuerca para pantalla S Repita para las otras 2 pantallas y portalamparas anillo de Hum 13 Coloque bulbos de 60 vatios en los z calos sretiuts Bulbo Usar 3 60 vatios maximo Tipo A bulbos Bulbos no incluidos LISTA DE COMPONENTS Disefio Componentes Cantidad Pantallas 3 pes anillo de enchufe 3 pcs Perillas 6 pes decorativas Brazos de la l mpara PIEZAS DE REPUESTO Revision 03 22 11 DESEMPAQUETE TODOS LOS COMPONENTES Y REVISE LAS PIEZAS Made in China Hecho en China ANTES DE LA ASAMBLEA
4. OID RISK OF ELECTRICAL SHOCK a ee E os BE SURE TO SHUT OFF POWER WHILE INSTALLING OR SERVICING THIS FIXTURE ay G D 9 Raise the fixture to the ceiling and weave the electrical wire Socket pS though the threaded tube on the mounting bracket 10 Thread the tube into the fixture canopy and fixture cap 11 Screw the fixture arms onto the fixture assembly and fixture canopy with the decorative knobs 12 Place shade onto the socket and secure with shade nut Socket Gir Repeat for other 2 shades and sockets Ring ss 13 Insert 60Watt bulbs into sockets QQ y ieee Bulb FOR RETURN S PURPOSES s PLEASE RETAI AL 2 PACKAGING TO MINIMIZE DAMAGE Uses 3 maximum 60Watt Type A Bulbs Bulbs not included COMPONENT LIST Components Shades Socket Rings Decorative Knobs Fixture Arms SPARE PARTS Revision 03 22 11 LAYOUT ALL COMPONENTS AND REVIEW PARTS BEFORE ASSEMBLY Made in China Hecho en China E SPRINGDALE Lt G H T INSTRUCCIONES DE ASAMBLEA Instrucciones de seguridad importantes Se debe desconectar la alimentaci n en la caja de fusibles antes de instalar esta l mpara El conductor de tierra de la l mpara desnudo o verde instalado NO debe estar conectado a conductores de suministro que lleven corriente c Ninguno de los cables debe sufrir da o en el aislamiento durante la instalaci n
5. er 8 gt Canopy 8 over chain 6 Thread Fixture Wires 13 through Chain pass Loop Collar Canopy Loop and Threaded Rod Connect Supply Wire with Fixture Wire using Wire Nut Connectors 17 Please see connection procedures below U I Connect the positive smooth wire of the fixture with DS Black supply wire with wire nut connector 17 Screw the 1 AS connector clockwise until you feel a firmness II Connect the negative ribbed wire from the fixture to the white supply wire from the outlet box in the same manner 111 Try gently to pull the connector off the wires If you can pull the connector off carefully re do the step above and check again for a firm connection IV Separately wrap the wires connections using electrical tape one inch below and include the connector V If your outlet box is provided with a grounding wire green or bare copper only attach this wire and the bare copper wire from the fixture to the green ground screw by wrapping both wires under the head of the screw and tightening screw If outlet box is not provided with grounding wire attach only the bare copper wire from the fixture to the green grounding screw Tuck all wires into Ceiling Outlet Box 7 Secure Canopy by screwing Loop Collar onto Loop 8 Follow Diagram on back side for fixture assembly instructions PA gt Y N conector h decables E SPRINGDALE sr H T I N Chain FTH10016 lee Fixture Ar WARNING TO AV
6. tro enganche de anillo lt y la tuerca roscada Conectar las cables del suministra el ctrico a los cables de la lampara utilizando los conectores de cable 17 Vea por favor conexi n procedimientos abajo I Conecte el cable liso positivo de la l mpara con el cable de suministro negro con conector de empalme pl stico 17 Rosque el conector en direcci n de las manecillas del reloj hasta que sienta firmeza Il Conecte el cable estriado negativo de la l mpara con el cable de suministro blanco de la caja de distribuci n a VPP conector de cables de la misma forma Ill Tratar de jalar un poco las conexi nes de los cables para asegurar que estan bien colocadas Si se salen los cables al jalar el conector se devera cuidadosamente volver a conectar y apretar el conector firme a los cables IV Envolver por separado las conexi nes de los cables utilizando cinta adhesiva para conductos el ctricos envolviendo hasta una pulgada de largo los cables incluyendo el conector V Si la caja el ctrica provee de cable de tierra color verde o color cobre conectar el cable de tierra de la caja el ctricia y el cable de tierra de la l mpara al tornillo verde de la abrazadera de montage juntando todos los cables y conectores 7 Asegure la base atornillando el enganche del anillo al anillo 8 Seguir el diagrama del lado de atras para seguir las instrucciones del ensamblado de la l mpara a G SPRINGDALE
Download Pdf Manuals
Related Search
Related Contents
Versamax I/O and Industrial Networking Application Guide TV PH14 GAME IBM System x 3500 M4 En téléchargeant ce document, vous souscrivez aux WYDOT TRAFFIC STUDIES MANUAL March 2011 Acesso ao Portal Protheus CAMARJ (PDF Eurofase 12615-018 Installation Guide User Guide - TFT レカロ ヤングスポーツ 適合記号の見方 Copyright © All rights reserved.