Home

Commercial Electric CER4G24R463WHP Instructions / Assembly

image

Contents

1. BX Cable Plaster Frame 4 Detach the remodel clips from the housing 5 Proceed to the ELECTRICAL CONNECTIONS section 6 Slide the housing through the hole opening as shown Fig 10 amp Fig 11 Plaster Frame Housing 7 Install the ceiling material such as drywall over the housing A template is provided to assist in making the holes in the ceiling material 8 Proceed to the LIGHT BULB AND TRIM INSTALLATION section ALL RIGHTS RESERVED COPYRIGHT COMMERCIAL ELECTRIC 2011 DROP CEILING INSTALLATION NOTE In additional to the main supply cable entering the junction box one more cable may be fed into the junction box to provide electrical power to NOTE Drop Gelling Installations are similar to new construction another light fixture intended to be on the same circuit No more than two installations except the hanger bars are attached to the T bars of a drop cables can be fed into the junction box It is very important that the knockout ceiling grid instead of ceiling joists as described below used for the second cable be adjacent to the knockout used for the first T BAR INSTALLATION Fig 12 cable Avoid using a knockout that is on the opposite side of the first 1 Install a ceiling tile onto the T bar grid at the installation location Using the Knockout Using an opposite knockout may make insertion through the provided template and a keyhole saw make a hole at the desired location in C lling hol
2. des fils d alimentation sur une longueur d environ 1 0 cm 3 8 in l aide des raccords de c ble effectuez les raccordements suivants TO FIL BLANC DU LUMINAIRE TO FIL NOIR DU LUMINAIRE TO FIL VERT DU LUMINAIRE FIL D ALIMENTATION BLANC NEUTRE FIL D ALIMENTATION NOIR CHAUD FIL D ALIMENTATION VERT NU TERRE Veillez a ce qu il n y ait aucun brin ou fil lache 4 Enroulez toutes les connexions avec du ruban isolant pour plus de s curit A NOTER si vous avez des questions concernant l installation lectrique veuillez consulter le code de I lectricit en vigueur dans votre province pour connaitre les m thodes de mise a la terre approuv es 5 Rentrez soigneusement tous les fils l int rieur de la bo te de jonction Fermez le couvercle de la boite de jonction Loquet de m tal Couvercle de la bo te de jonction Entr e d foncable Connecteur de C ble BX c ble BX Fig 13 Bo tier Raccord de c ble NOTER Outre le c ble d alimentation principal la bo te de jonction peut accueillir un second c ble pour alimenter un autre luminaire reli au m me circuit Ne pas relier plus de deux cables une m me bo te de jonction ll est tres important que l entr e d fon able utilis e pour le second c ble sera adjacent au l entr e d foncable utilis pour le premier c ble vitez d utiliser un entr e d fon able qui est sur le c t oppos de la premi re entr
3. Abre la puerta de la caja el ctrica levantando el pestillo de metal 2 Con un destornillador rompe el tap n de una de las entradas redondas en la caja de el ctrica Conecta un cable conector de cable BX o un cable conector de cable NM ROMEX del tama o adecuado en la abertura de la entrada Pasa el cable BX or cable NM ROMEX a trav s del conector dejando 3 7 6 cm de cable holgado dentro de la caja el ctrica Ajusta el conector para asegurar el cable en su sitio 3 Retira al menos 3 7 6 cm del revestimiento exterior del cable y quita la envoltura de papel o pl stico Quita aproximadamente 3 8 1 0 cm de aislamiento de los extremos de los cables de suministro Usando las tuercas de cable haz las siguientes conexiones CABLE DE SUMINISTRO BLANCO AL CABLE BLANCO DE LA NEUTRO L MPARA CABLE DE SUMINISTRO NEGRO AL CABLE NEGRO DE LA L MPARA VIVO CABLE DE SUMINISTRO VERDE AL CABLE VERDE DE LA L MPARA DESNUDO A TIERRA Aseg rate de que no hay hilos o cables sueltos 4 Envuelva todas las conexiones de cables con cinta de aislar para una conexi n m s segura NOTA Si tiene preguntas con respecto a las conexiones el ctricas consulte el c digo el ctrico de su localidad para los m todos aprobados de la conexi n a tierra 5 Con cuidado introduce todos los cables y conexiones de cable en la caja el ctrica Cierre la puerta de la caja el ctrica Pestillo de 1 a metal Cubierta Puerta de Cable BX
4. a con la secci n de INSTALACI N DEL FOCO Y EL ADORNO TODOS LOS DERECHOS RESERVADOS COPYRIGHT O COMMERCIAL ELECTRIC 2011 INSTALACI N EN TECHO FALSO NOTA Las instalaciones de falso techo son similares a las instalaciones de nueva construcci n salvo las barras de suspensi n est n unidos a las barras en T de una rejilla de falso techo en lugar de las vigas del techo como se explica a continuaci n INSTALACI N SOBRE BARRA EN T Fig 12 1 Instala una placa de techo en el sistema de suspensi n en T donde ira la l mpara Usa la plantilla incluida y un serrucho de punta fina para abrir un orificio sitio deseado de la placa de techo 2 Coloca el ensamblaje de la barra de colgar y el marco de yeso sobre la placa de techo Ajusta el ancho de las dos barras para colgar seg n la distancia entre las dos barras en T alineando cada abrazadera de montaje con el tope de la barra en T correspondiente Ejerce presi n sobre todas las abrazaderas de montaje hasta que encajen en la barra en T NOTA Las abrazaderas de montaje tienen orificios que pueden usarse para asegurar las barras para colgar a la barra en T Las piezas necesarias es decir tornillos tuercas hexagonales pueden comprarse por separado B Marco de arra para aii yee Abrazadera de montaje Placa de techo Fig 12 Barra en T Orificio 3 Proceed to Step 3 of the CEILING JOIST INSTALLATION section CONEXIONES EL CTRICAS Fig 13 8 14 1
5. la caja el ctrica Entrada ra Cable E conector de Fig 13 cable BX Tuerca de cable NOTA Adem s del cable principal de suministro se puede conectar otro cable a la caja el ctrica que d electricidad a otra l mpara en el mismo circuito No pueden conectarse m s de dos cables en la caja el ctrica Es muy importante que la entrada utilizado para el segundo cable colindante con la entrada utilizado para el primer cable Evite el uso de un entrada que est en el lado opuesto de la primera entrada El uso de un entrada lo contrario puede hacer la inserci n a trav s del agujero del techo m s dif cil INSTALACI N DEL FOCO Y EL ADORNO Fig 15 16 17 amp 18 1 Siga una de las figuras a continuaci n para instalar el foco y el adorno 2 La instalaci n est completa Reestablezca la energ a el ctrica PET Portafoco A de ji Adorno Fig 16 SOLUCI N DE PROBLEMAS S NTOMA POSIBLE CAUSA SOLUCI N El interruptor de la pared o el Enciende el interruptor o el cortacircuitos est n apagados cortacircuitos Los cables est n flojos o Revisa las conexiones conectados incorrectamente E ibl l mbilla no sirva poe ae ae 5 3 as Reemplaza la bo mbilla Prueba la bombilla en otra l mpara La bombilla est floja Taprieta la bo mbilla en el portabo mbillas La luz no enciende La luz se apaga despu s de alg n tiempo Poco despu s se vuelve a encender La luz contin a es
6. de separaci n de centro a centro Si las vigas est n a menos de 16 40 6 cm de distancia las barras para colgar se deben acortar para ajustarse al espacio angosto Para acortarlas 1 Abre las barras lo m s posible Fig 7 2 Dobla hacia adelante y hacia atr s en el 1 pliegue desde el centro la barra macho 4 Separe los clips de remodelaci n de la cubierta de cada barra para colgar hasta que se separe Dobla la barra hembra hacia 5 Contin a con la secci n de CONEXIONES EL CTRICAS adelante y hacia atr s en la 1 muesca desde el centro hasta que se separe Fig 6 Deslice la cubierta a trav s del orificio del techo Fig 10 amp Fig 11 7 1er Pliegue Doblar Aqui Fig 7 1 Muesca Doblar Aqui 3 Desliza las barras macho y hembra hasta juntarlas y verifica si la barra de colgar est lo suficientemente corta Si no separa las barras macho y hembra y desprende cualquier material de sobra en el pliegue y muesca siguientes Desprende material hasta alcanzar el largo apropiado No desprendas m s de lo necesario 4 Una vez que se ha alcanzado el largo correcto separa las barras macho y hembra Inserta las barras hembra en las gu as del marco de yeso Inserta las 7 Instala el material del techo como por ejemplo drywall sobre la carcasa Se ha barras macho en las barras hembra incluido una plantilla para ayudarte a marcar los orificios en el material del techo 8 Contin
7. lado de adentro de la habitaci n Luego debe pasarse el cableado a trav s del orificio y conectarse a la l mpara Finalmente se introducir la l mpara en la abertura del techo y se fijar en la superficie usando el clips de remodelaci n Para utilizar este producto en aplicaciones de construcci n nueva el marco de yeso de Commercial Electric y el barra de suspensi n de Commercial Electric se debe comprar por separado En una aplicaci n de la nueva construcci n la superficie del techo a n no se ha instalado y las vigas del techo est n expuestos y accesibles ANTES DE EMPEZAR 1 Para garantizar una instalaci n satisfactoria aseg rate de leer estas instrucciones y revisar minuciosamente los diagramas antes de empezar 2 Todas las conexiones el ctricas deben cumplir con las ordenanzas y c digos locales Si no est s familiarizado con los m todos de instalaci n del cableado el ctrico contrata los servicios de un electricista certificado y calificado 3 Antes de comenzar la instalaci n desconecta el suministro de electricidad apagando el cortacircuitos o retirando el fusible en la caja de fusibles Desconectar la electricidad en el interruptor de la pared no ser suficiente para prevenir una descarga el ctrica 4 Verifica que la fuente de electricidad sea adecuada para una carga el ctrica adicional La electricidad debe venir de un solo circuito de 110 120 voltios 60 Hz Un circuito derivado est ndar de 120 volt
8. pliez ici A 3 Glissez les sections m les et femelles l une dans l autre pour v rifier si la barre de suspension a t suffisamment raccourcie Au besoin s parez de nouveau les deux sections et raccourcissez chacune d entre elles la prochaine rainure ou encoche jusqu ce que vous obteniez la longueur d sir e Prenez garde de ne pas trop raccourcir la barre 4 Lorsque vous avez obtenu la longueur d sir e s parez les sections m les et femelles Glissez les sections femelles dans les guides du cadre sceller Glissez les sections m les dans les sections femelles ection m le r INSTALLATION SUR SOLIVES DE PLAFOND 1 Soulevez le cadre en pl tre et les barres de suspension vers l emplacement d sir entre les deux solives de plafond Ajustez la largeur des deux barres de suspension en fonction de la distance qui s pare les deux solives Placez le luminaire de mani re que les supports des barres de suspension reposent contre le bord inf rieur des solives Enfoncez les clous des barres de suspension dans les solives l aide d un marteau pour fixer le luminaire en place Fig 8 Barre de Clou suspension Bord A de la solive Support de barres de suspension sceller 2 Glissez le cadre sceller le long des barres de suspension jusqu l emplacement d sir Serrer la vis de blocage pas montr du cadre en sceller pour le verrouiller
9. Check the contents of the box You should receive e 1 Housing can e 1 Template junction box e 3 Remodel clips pre e 1 Trim assembly attached to housing e 3 Wire Nuts INSTALLATION amp OPERATION INSTRUCTIONS 4 10 2 CM NON IC RECESSED LIGHTING KIT QUESTIONS CALL TOLL FREE 1 800 345 0542 GETTING STARTED WARNING First disconnect electricity at the circuit breaker or the fuse box Disconnecting power by using the wall switch is not sufficient to prevent electrical shock Choose the location for the fixture s keeping in mind the 6 15 2 cm depth clearance accessibility for the electrical supply and the 1 3 cm clearance from the joists floor boards or any other combustible material REMODEL INSTALLATION MAKING THE HOLE RUNNING THE SUPPLY WIRING TO THE HOLE 1 Cut a 4 Y 10 8 cm hole into the ceiling after choosing the appropriate location A template is provided to assist in making the hole Fig 2 Fig 2 Keyhole saw 2 Clear out any insulation necessary to maintain the 3 7 6 cm spacing specified in the CAUTION section found in the beginning of these instructions See Fig 1 3 Run armored cable BX or non metallic NM cable also known as Romex from your circuit breaker or fuse panel to the 4 10 8 cm hole providing 6 15 2 cm to 8 20 3 cm of slack extending below the hole Cable having up to 12 AWG wiring may be used Fig 3 WARNING Us
10. Commercial Electric MODELS CER4R CER4G10R CER4G24R READ ALL THE INSTRUCTIONS TOOLS amp MATERIALS REQUIRED e Keyhole Saw or 4 10 8 cm Hole Saw e Flathead Screwdriver e Insulated Pliers CAUTION Before assembling your lighting fixture refer to the ELECTRICAL CONNECTIONS section If you feel you do not have electrical wiring experience refer to a do it yourself wiring handbook or have your fixture installed by a qualified licensed electrician NOTE This fixture is a Non IC type housing Do not install insulation within 3 in 7 6 cm of the housing Fig 1 In addition the housing must be installed at least Y 1 3 cm away from any combustible material such as a wood joist or floorboard The ceiling surface is exempt from this requirement and may be in contact with the bottom part of the housing e Ladder BX or NM Cable BX or NM Cable Connectors e Pencil e UL Listed Electrical Tape Insulation 3 in 7 6 cm min gap IMPORTANT NOTE Out of the box this product can be use in REMODEL applications In a remodel application a ceiling surface already exists and there is no access above the surface to the ceiling joists To install this fixture a hole must be made in the existing ceiling from the room side Then electrical wiring must be run to this hole and connected to the fixture The fixture is finally inserted into the ceiling hole which secures itself to the ceiling surface usin
11. TLANTA GA 30339 ALL RIGHTS RESERVED COPYRIGHT COMMERCIAL ELECTRIC 2011 Commercial Electric MODELOS CER4R CER4G10R CER4G24R LEER TODAS LAS INSTRUCCIONES HERRAMIENTAS Y MATERIALES NECESARIOS e Escalera e Serrucho de Punta Fina o Broca Alicate Aislado e Cable BX o NM Sierra de 4 Y 10 8 cm e Lapiz e Conectores de Cable 3 Destornillador de Cabeza e Cinta Aislante con BXoNM Plana Clasificaci n UL PRECAUCI N Antes de ensamblar tu l mpara consulta la secci n de CONEXIONES EL CTRICAS Si crees que no tienes experiencia con cableado el ctrico consulta el manual hazlo t mismo sobre cableado o p dele a un electricista calificado y certificado que instale tu l mpara NOTA Esta l mpara tiene una carcasa de tipo No IC No instalar aislamiento a menos de 4 10 2 cm de la carcasa Fig 1 Adem s la carcasa debe instalarse a un m nimo de 1 27 mm de cualquier material inflamable como vigas de madera o tableros de piso La superficie del techo es una excepci n a este requisito y puede entrar en contacto con la parte inferior de la carcasa 3 7 6 cm de espacio Aislamiento m nimo NOTA IMPORTANTE Fuera de la caja este producto se puede utilizar en aplicaciones de remodelaci n En usos para remodelaci n ya existe una superficie de techo y no hay acceso a las vigas del techo de la parte superior Para instalar esta l mpara se debe abrir un orificio en el techo ya existente desde el
12. a bo te ce produit peut tre utilis dans des applications remodeler Par plafond existant on entend un plafond cloisonn qui n offre aucun acces aux solives situ es derri re la cloison du plafond Pour installer ce luminaire il faut d couper un orifice dans la cloison du plafond puis passez les fils d alimentation dans l orifice pour les relier a la bo te de jonction du luminaire La niche est ensuite ins r e dans orifice du plafond ou elle se fixe en place gr ce a des fixations qui exercent une pression sur le dessus de la cloison Pour utiliser ce produit dans les applications de nouvelle construction un cadre en pl tre de Commercial Electric et un kit de barre de suspension de Commercial Electric doivent tre achet s s par ment Dans une nouvelle construction la surface du plafond n a pas encore t install et les solives du plafond sont encore expos s et accessibles AVANT DE COMMENCER 1 Afin d installer le luminaire ad quatement veuillez lire toutes les instructions et examiner attentivement les sch mas avant de commencer 2 Tous les raccordements lectriques doivent tre conformes aux normes et r glements locaux de m me qu au code national de l lectricit Si vous ne connaissez pas les principes de raccordement d une installation lectrique veuillez utiliser les services d un lectricien qualifi 3 Avant de commencer l installation couper l alimentation au niveau du disjoncteur ou en ret
13. and determine if the hanger bar has been shortened enough If not separate the male and female bars and break off additional material at the next crease and notch Continue to break off material until proper length is achieved Do not break off any more material than necessary 4 Once proper length is achieved separate the male and female bars Slide the female bars into the guides of the plaster frame Slide the male bars into the female bars CEILING JOIST INSTALLATION 1 Raise the plaster frame and hanger bar assembly to the desired location between the two ceiling joists Adjust the width of both hanger bars to the distance between the joists Position the assembly so that the mounting clips of the hanger bars cup underneath the bottom edges of the joists Hammer down the nails of the hanger bars into the joists to secure the assembly into place Fig 8 Mounting Clip Plaster Bottom Frame edge of Fig 8 joist 2 Slide the plaster frame along the hanger bars to the desired position Tighten the locking screw not shown of the plaster frame to lock it in place 3 Run armored cable BX or non metallic NM cable also known as Romex from your circuit breaker or fuse panel to the plaster frame hole providing 6 15 2 cm to 8 20 3 cm of slack extending below the hole Cable having up to 12 AWG wiring may be used Fig 9 WARNING Use cables having wires rated 90 C or more
14. e cables having wires rated 90 C or more Ceiling 4 Proceed to the ELECTRICAL CONNECTIONS section MOUNTING THE HOUSING TO THE CEILING 1 Slide the housing through the hole opening Fig 4 Hole Ceiling Remodel clip ALL RIGHTS RESERVED COPYRIGHT O COMMERCIAL ELECTRIC 2011 2 When the foot of each remodel clip touches the ceiling push the remodel clip through the I shaped opening Fig 5 Housing Remodel clip is Fig 5 3 Continue pushing the clips through until they snap into position The foot of each clip will hook the edge of the hole preventing the housing from sliding further into the hole Fig 6 4 Proceed to the LIGHT BULB AND TRIM INSTALLATION section NEW CONSTRUCTION INSTALLATION HANGER BAR PREPARATION The hanger bars are designed for joists that are spaced 16 40 6 cm to 26 66 0 cm center to center apart lf the joists are less than 16 40 6 cm apart the hanger bars must be shortened to accommodate the narrower space To shorten them 1 Spread the bars as wide as possible Fig 7 2 For each hanger bar bend the male bar back and forth at the 15t crease from the center until it splits Bend the female bar back and forth at the 1st notch from the center until it splits Fig 7 1st Crease Bend Here 1st Notch Bend Here Fig 7 3 Slide the male and female bars together
15. e d foncable En utilisant une entr e d fon able contraire peut rendre l insertion dans le trou au plafond plus difficile INSTALLATION DE L AMPOULE ET DE LA GARNITURE Fig 15 16 17 amp 18 1 Suivez l une des figures ci dessous pour installer ampoule et de la garniture 2 L installation est termin e R tablissez l alimentation lectrique ee Douille den iP Garniture Ampoule re Douille Ampoule 4 Garniture D PANNAGE SYMPT ME CAUSE POSSIBLE SOLUTION Ouvrez l interrupteur ou le disjoncteur V rifiez les connexions Ml lectriques La lumi re ne s allume pas L ampoule est grill e V rifiez l ampoule en l ins rant dans un luminaire qui fonctionne Remplacez l ampoule Serrez l ampoule dans la douille L ampoule est mal viss e Le capteur thermique est d teindre en raison de la chaleur excessive Espace de suite toute l isolation d au moins 7 6 cm 3 in du bo tier comme indiqu dans la Fig 1 The thermal sensor is triggering due to excessive heat COMMERCIAL ELECTRIC 2455 PACES FERRY RD NW ATLANTA GA 30339 TOUS DROITS RESERVES COMMERCIAL ELECTRIC 2011
16. e more difficult the ceiling tile 2 Place the plaster frame hanger bar assembly onto the ceiling tile into the LIGHT BULB AND TRIM INSTALLATION Fig 15 16 17 amp 18 newly created hole making sure the bottom of the plaster frame feeds en through the hole Adjust the width of both hanger bars to the distance Polo oe of the figures below to install the trim and light bulb between the two T bars aligning each mounting clip with the top of its 2 Installation is complete Restore electrical power corresponding T bar Press down on all mounting clips until they snap onto the T bar NOTE Holes are provided on the mounting clips that can be used to secure the hanger bars to the T bar Parts l e screws hex nuts can be purchased separately for this purpose Plaster Hanger ama Mounting clip Fig 12 Ceiling tile 3 Proceed to Step 3 of the CEILING JOIST INSTALLATION section T bar Hole ELECTRICAL CONNECTIONS Fig 13 amp 14 1 Open the junction box s door by pulling on its metal tab 2 Break off one of the round knockouts from the junction box using a screwdriver Secure an appropriately sized BX or NM Romex cable connector to the knockout opening Feed the BX or NM Romex cable through the connector providing 3 7 6 cm of slack inside the junction box Tighten the connector to secure the cable in place 3 Remove at least 3 7 6 cm of the cable s outer sheath and remove the plastic or paper over
17. en place 3 Passez un c ble arm BX ou un c ble non m tallique NM galement appel cable Romex du disjoncteur ou de la bo te de fusibles jusqu l orifice de cadre en pl tre en laissant d passer une longueur de 15 24 cm 6 in 20 32 cm 8 in hors de l orifice Vous pouvez utiliser un c ble de calibre 12 AWG ou moins Fig 9 MISE EN GARDE utilisez des fils d alimentation con us pour r sister a une temp rature de 90 et plus 4 D tachez les fixations du bo tier 5 Consultez la section CONNEXIONS ELECTRIQUES 6 Faites glisser le bo tier dans le orifice comme indiqu Fig 10 amp Fig 11 sceller 7 Installez les cloisons du plafond ex cloison s che par dessus la niche Utilisez le gabarit fourni pour pratiquer les ouvertures n cessaires dans la cloison du plafond 8 Consultez la section INSTALLATION DE L AMPOULE ET DE LA GARNITURE TOUS DROITS R SERV S COMMERCIAL ELECTRIC 2011 INSTALLATION DANS UN PLAFOND SUSPENDU A NOTER les installations dans plafond suspendu sont similaires aux installations nouvelles constructions a l exception des barres de suspension sont attach s a la T barres d une grille de plafond suspendu au lieu de solives de plafond comme d crit ci dessous INSTALLATION SUR LE BARRE ENT Fig 12 1 Installez un carreau pour plafond sur les barres en T l endroit d sir l aide du gabarit et d un passe partout pratiquer une
18. g special remodel clips provided To use this product in NEW CONSTRUCTION applications a Commercial Electric plaster frame and Commercial Electric hanger bars must be purchased separately In a new construction application the ceiling surface has not yet been installed and the ceiling joists are still exposed and accessible BEFORE YOU BEGIN 1 To ensure the success of the installation be sure to read these instructions and review the diagrams thoroughly before beginning 2 All electrical connections must be in accordance with local code and ordinances If you are unfamiliar with methods of installing electrical wiring secure the services of a qualified licensed electrician 3 Before starting the installation disconnect electricity at the circuit breaker or the fuse box Disconnecting power by using the wall switch is not sufficient to prevent electrical shock 4 Check if the power source is suitable for the added electrical load Power should be supplied by a 110 120 volt 60 Hz single circuit A standard 120 volt 15 amp branch circuit is designed to carry a maximum load of 1800 watts We recommend that the total wattage of all the lights and appliances on that circuit not exceed 80 or 1440 watts of the maximum electrical capacity 5 This fixture is designed to be used on ceiling surfaces that are 3 8 1 0 cm 1 2 1 3 cm or 5 8 1 6 cm thick It cannot be used on any other ceiling thickness UNPACK THE FIXTURE
19. ios y 15 amperios est dise ado para soportar una carga m xima de 1800 vatios Recomendamos que el vataje total de todas las luces y electrodom sticos del circuito no exceda el 80 de la capacidad el ctrica m xima o 1440 watts 3 Esta l mpara est dise ada para ser usada en superficies de techo con un grosor de 3 8 1 0 cm Y 1 3 cm o 5 8 1 58 cm No puede usarse en techos de otro grosor DESEMPACAR LA LUMINARIA Revisa el contenido de la caja Debes tener 1 Plantilla 3 Clips de remodelaci n pre adjunta a la cubierta 3 Tuercas de cable e 1 Cubierta lata caja el ctrica e 1 Adorno INSTRUCCIONES DE INSTALACI N Y FUNCIONAMIENTO JUEGO DE LUMINARIA EMPOTRADA TIPOS NO IC DE 4 10 2 CM PREGUNTAS LLAMA GRATIS AL 1 800 345 0542 COMENCEMOS ADVERTENCIA Primero desconecta la electricidad en el cortacircuitos o en la caja de fusibles Desconectar la electricidad en el interruptor de la pared no ser suficiente para prevenir una descarga el ctrica Elige el lugar donde ira n la s l mpara s tomando en cuenta que debe n contar con 6 15 24 cm de espacio de profundidad tener acceso al suministro el ctrico y estar a 72 1 27 mm de las vigas tableros de piso cualquier otro material inflamable REMODELAR LA INSTALACI N ABRIR EL ORIFICIO PASAR EL CABLEADO DE SUMINISTRO POR EL ORIFICIO 1 Una vez que has elegido el lugar adecuado corta una abert
20. irant le fusible correspondant dans la bo te a fusibles La mise hors tension laide de l interrupteur du luminaire n est pas suffisante pour liminer le risque de d charge lectrique 4 V rifiez que la source d alimentation supporte la charge lectrique suppl mentaire L alimentation doit tre fournie par un circuit simple de 110 120 V 60 Hz Un circuit de d rivation standard de 120 V 15 A est con u pour une charge maximale de 1 800 W La puissance totale recommand e de toutes les lampes et autres dispositifs branch s sur ce circuit ne doit pas d passer 80 de la capacit lectrique maximale soit 1 440 W 5 Ce luminaire est con u pour une installation sur une cloison de plafond d une paisseur de 1 0 cm 3 8 in 1 3 cm Y in ou 1 6 cm 5 8 in Le luminaire ne peut pas tre install sur un plafond d une autre paisseur D BALLER LE LUMINAIRE V rifiez le contenu de la boite Vous devriez y trouver e 1 bo tier niche bo te de jonction e 1 garniture e 1 gabarit e 3 raccords de c ble e 3 fixations pour r novation pr fix sur le bo tier MODE D INSTALLATION ET D EMPLOI POUR LUMINAIRE ENCASTRE DE 7 6 CM 4 IN POUR PLAFOND NON ISOLE LISEZ TOUTES LES INSTRUCTIONS DES QUESTIONS APPELEZ SANS FRAIS AU 1 800 345 0542 POUR COMMENCER MISE EN GARDE coupez tout d abord l alimentation lectrique au niveau du disjoncteur La mise hors tension l aide de l interrupteur mural n est
21. l ensamblaje de modo que las abrazaderas de Cubierta montaje de las barras para colgar queden debajo de los bordes inferiores de las vigas Martilla los clavos de las barras para colgar en las vigas para fijar el ensamblaje en su sitio Fig 8 Clip de remodelaci n Otro extremo Fig 5 3 El clip finalmente entrar a presi n en la posici n cerrada El pie enganchara el Fig 8 Borde borde de la abertura del agujero Fig 6 ES inferior de acode laviga Abrazadera Cubierta de montaje yeso 2 Desliza el marco de yeso a lo largo de las barras para colgar hasta la posici n deseada Apriete el tornillo de sujeci n no se muestra de la estructura de yeso para Clip de que encaje en su posici n remodelaci n 3 Pasa el cable blindado BX o el cable no met lico NM tambi n conocido como Romex a trav s del cortacircuitos o panel de fusibles hasta el orificio del marco de yeso dejando entre 6 15 2 cm y 8 20 3 cm de cable sobrante extendido por debajo del orificio Puedes usar cables con un m ximo de 12 AWG de cableado Fig 9 ADVERTENCIA Usa cables con clasificaci n de 90 C o mayor Cable blindado Fig 6 Agujero Otro extremo 4 Contin a con la secci n de INSTALACI N DEL FOCO Y EL ADORNO CONSTRUCCI N NUEVA LA INSTALACI N PREPARACI N DE LA BARRA PARA COLGAR Las barras para colgar est n dise adas para montarse entre vigas con 16 40 6 cm a 26 66 0 cm
22. ond Fixation Boitier TOUS DROITS RESERVES COMMERCIAL ELECTRIC 2011 2 Lorsque le pied de chacune des fixations touche le plafond poussez les fixations a travers les encoches en l jusqu ce qu elles s enclenchent Fig 5 Boitier Fixation Pied Fig 5 3 Continuez a pousser les fixations a travers jusqu ce qu ils s enclenchent Le pied de chaque fixation s agrippera au bord du trou emp chant ainsi le bo tier de s enfoncer plus loin Fig 6 Plafond 4 Consultez la section INSTALLATION DE L AMPOULE ET DE LA GARNITURE L INSTALLATION DE NOUVELLE CONSTRUCTION PR PARATION DU SUPPORT DE FIXATION Les barres de suspension sont con ues pour les solives de plafond espac es de 40 6 cm 16 in 66 0 cm 26 in d un centre l autre Si les solives sont install es moins de 40 6 cm 16 in les unes des autres les barres de suspension doivent tre raccourcies Pour ce faire vous devez 1 Allongez les barres au maximum Fig 7 2 Pliez la section m le de chacune des barres de suspension d avant en arri re au niveau de la premi re rainure partir du centre jusqu ce que la barre se sectionne en deux Pliez la section femelle d avant en arri re au niveau de la premi re encoche partir du centre jusqu ce que la barre se sectionne en deux Fig 7 1 e rainure pliez ici Section femelle Fig 7 1 encoche
23. ouverture dans le plafond l emplacement d sir 2 Placez le cadre sceller et le barres de suspension sur la carreau pour plafond Ajustez la largeur des barres de suspension de la niche pour qu elle corresponde la distance entre les deux barres en T en alignant chacune des supports avec le dessus de la barre en T correspondante Appuyez sur toutes les fixations jusqu ce qu elles s enclenchent sur la barre en T NOTER les fixations comportent des trous pour permettre de fixer les barres de suspension aux barres en T Des pi ces ex vis crous hexagonaux peuvent tre achet es s par ment cette fin Barres de pus Support de suspension barres de suspension Barre en T Fig 12 Carreau pour Orifice plafond RACCORDEMENTS LECTRIQUES Fig 13 amp 14 1 Ouvrez le couvercle de la bo te de jonction en soulevant le loquet de m tal 2 Enfoncez une des entr es d fon ables de la bo te de jonction l aide d un tournevis Fixez un connecteur de c ble BX ou un connecteur de c ble NM ROMEX de taille ad quate dans l ouverture de l entr e d fon able Passez le c ble BX or c ble NM ROMEX dans le connecteur en laissant d passer une longueur de 7 62 cm 3 in l int rieur de la bo te de jonction Serrez le connecteur pour fixer le c ble en place 3 Retirez la gaine du c ble sur une longueur d au moins 7 62 cm 3 in et enlevez le plastique ou l enveloppe de papier D nudez l extr mit
24. pas suffisante pour liminer les risques de d charge lectrique Choisissez l emplacement du luminaire en tenant compte du d gagement minimal requis de 15 24 cm 6 in de l acc s a une source d alimentation lectrique et du d gagement minimal de 1 27 cm 1 in par rapport aux solives au bois du plancher ou toute autre mati re combustible L INSTALLATION DE REMODELER D COUPAGE DE L ORIFICE ET PASSAGE DES FILS D ALIMENTATION 1 D coupez un orifice de 10 8 cm 4 in dans la cloison du plafond l emplacement d sir Utilisez le gabarit fourni pour tracer un cercle au plafond Fig 2 Fig 2 Scie a guichet 2 Retirez l isolant de mani re a permettre un d gagement de 7 6 cm 3 in tel qu indiqu dans la partie MISE EN GARDE au d but du mode d installation Voir Fig 1 3 Passez un c ble arm BX ou un c ble non m tallique NM galement appel cable Romex du disjoncteur ou de la bo te de fusibles jusqu Porifice de 10 8 cm 4 in en laissant d passer une longueur de 15 2 cm 6 in 20 3 cm 8 in hors de Porifice Vous pouvez utiliser un c ble de calibre 12 AWG ou moins Fig 3 MISE EN GARDE utilisez des fils d alimentation concus pour r sister a une temp rature de 90 et plus Fig 3 Plafond 4 Consultez la section CONNEXIONS ELECTRIQUES INSTALLATION DE LA NICHE AU PLAFOND 1 Faites glisser le boitier dans le orifice Fig 4 Orifice Plaf
25. te ciclo indefinidamente Espacio a la basura cualquier aislamiento por lo menos 3 7 6 cm de la vivienda como se muestra en la Fig 1 El sensor t rmico se apaga por exceso de calor COMMERCIAL ELECTRIC 2455 PACES FERRY RD NW ATLANTA GA 30339 TODOS LOS DERECHOS RESERVADOS COPYRIGHT O COMMERCIAL ELECTRIC 2011 Commercial Electric MODELES CER4R CER4G10R CER4G24R OUTILS ET MATERIAUX NECESSAIRES e Echelle e Cable BX ou NM e Connecteurs de c ble BX ou NM e Scie guichet ou scie emporte pi ce de 10 8 cm 4 in e Tournevis t te plate e Pinces isolantes MISE EN GARDE Avant de commencer assembler votre luminaire consultez les directives la partie RACCORDEMENTS ELECTRIQUES Si vous ne connaissez pas les principes de raccordement d une installation lectrique consultez un manuel d installation lectrique ou utilisez les services d un lectricien qualifi Crayon Ruban isolant homologu UL NOTER ce luminaire comporte une niche con ue pour les plafonds non isol s Ne pas installer d isolant a moins de 7 6 cm 3 in de la niche Fig 1 De plus la niche doit tre install e une distance d au moins 1 27 cm 2 in de toute matiere combustible tels une solive ou un plancher en bois La cloison du plafond est exclue de cette r gle et peut tre en contact avec la partie inf rieure de la niche 7 6 cm 3 in minimum l espace NOTE IMPORTANTE Hors de l
26. ura de 4 10 8 cm en el techo Se ha incluido una plantilla para ayudarte a abrir el orificio Fig 2 ig EZ ZT Orificio Fig 2 X ze Y Serrucho de punta fina SA NE 2 Descarta cualquier aislamiento de modo que dejes los 3 7 62 cm de espacio especificados en la secci n de PRECAUCI N que est al principio de estas instrucciones Ver Fig 1 3 Pasa el cable blindado BX o el cable no met lico NM tambi n conocido como Romex a trav s del cortacircuitos o panel de fusibles hasta el orificio de 4 Y 10 8 cm dejando entre 6 15 2 cm y 8 20 3 cm de cable sobrante extendido por debajo del orificio Puedes usar cables con un m ximo de 12 AWG de cableado Fig 3 ADVERTENCIA Usa cables con clasificaci n de 90 C o mayor 4 Contin a con la secci n de CONEXIONES EL CTRICAS MONTAR LA CARCASA EN EL TECHO 1 Deslice la cubierta a trav s del orificio del techo Fig 4 Orificio Techo Clip de remodelaci n Cubierta TODOS LOS DERECHOS RESERVADOS COPYRIGHT O COMMERCIAL ELECTRIC 2011 2 Cuando la cubierta est casi completamente insertada empuje los clips de INSTALACI N EN VIGAS DEL TECHO remodelaci n a trav s de la abertura de la ranura en I Fig 5 o 1 Alza ensamblaje del marco de yeso y barra para colgar hasta la posici n deseada entre las dos vigas del techo Ajusta el ancho de las dos barras para colgar seg n la distancia entre las vigas Coloca e
27. wrap Strip approximately 3 8 1 0 cm of insulation Socket from the ends of all supply wires Using wire nuts make the following wire Light Lad 19 connections 4 Fig 17 bulb WHITE SUPPLY WIRE NEUTRAL TO WHITE FIXTURE WIRE BLACK SUPPLY WIRE HOT TO BLACK FIXTURE WIRE GREEN BARE SUPPLY WIRE GRND TO GREEN FIXTURE WIRE Be sure that there are no loose strands or loose wires 4 Wrap all wire connections with electrical tape for a more secure connection NOTE If you have electrical questions consult your local electrical code for approved grounding methods 5 Carefully stuff all wires and wire connections into the junction box Close the junction box s door Metal tab TROUBLESHOOTING al Junction SYMPTOM POSSIBLE CAUSE SOLUTION box ach door able Wall sw itch or circuit breaker is _ Knockout off Turn on switch or circuit breaker BX Cable nig Housing connector ees eile ee Check w ire connections The light does not turn on Light bulb may be dead Test light bulb in a know n working light Replace light bulb fixture Light bulb is loose Tighten light bulb in socket The light is turning off after being on for some time Soon after The thermal sensor turning off it turns back on The due to excessive heat light continues this cycle indefinitely Space aw ay any insulation at least 3 7 6 cm fromthe housing as show n in Fig 1 COMMERCIAL ELECTRIC 2455 PACES FERRY RD NW A