Home

Worldwide Lighting W83117C20-GT Instructions / Assembly

image

Contents

1. REW aaee ne aeaa aan COLLAR CHAIN j Frame Assembly Instructions 8 Install scrolls into washer with screws provided Install arms into large arm washer Line up holes in arms with dimple in washer Use lock washer and nut to secure arms in place Connect bare ground wires in each arm to bare ground wire in center column Use electrical tape to secure wire nuts NO MORE THAN 5 WIRESPER WIRE NUT Sufficient quantities of jumper wires and wire nuts are provided 9 Connect white arm wires to neutral column wire ribbed or marked is neutral Connect black arm wires to power wire in column Carefully press wires as cloes as possible to the underside of washer 10 Attach light assembly with lock washer and coupling with pipe Install 5 C7 bulbs Attach glass assembly with rosette and round nut 11 Install bobeches and bulbs connect power and test the fixture BEFORE trimming If any of the bulbs do NOT light DISCONNECT POWER Double check the wire connections The end WARNING CONTENTS ARE FRAGILE HANDLE WITH CARE The metal frame and crystal components of this chandelier are very delicate Please excersise extreme Caution during unpacking and installation WARNING After passing the main eiectrical wire through the 10mm pipe and connecting the pipe to the main body top connector place all remaining pieces as shown in nurmerical order and in the orientation depicted Refer to the parts list to avoid confusion b
2. W 8d311 7C20 CL D20 H19 L6 We are dedicated to providing the finest quality crystal chandelier for our customers Our master craftsmen and designer pride themselves on their attention to detail prompt efficient service is our priority Enclosed are detailed instructions on how to properly install your chandelier Please read all instructions carefully and thoroughly If you have any questions please fell free to call our toll free DHANDELIER HOTLINE AT 1 890 411 8999 ON Crystal Dressin Instructions A Al B 14mmX1 PRE 2 X 14mmX3 14mmX1 OO A 2 5 X 14mmX10 When dressing the chandelier with the crystals please remember to wear either rubber or cotton gloves So as to prevent any damage or smudging on the crystals B1 C 14mmX 1 epee 14mmX5 an F G i 14mmX3 14mmX1 AN ARN MA 40mmX 1 40mmxX 1 va a M6 strings C 24strings E 6 strinss _ B 6 strings D 6 strings F 1 strinss CANOPY PARTS LIST Existing Electrical Box Crossbar Screws Crossbar Screws x 2 not srpplied Canopy Glass Saucer Chains Wire Connector Shrinkable tube Cable tie Ground Wire CANOPY INSTALLATION DIAGRAM GROUND WIRE _ NS me LARGE HEX J NUTS CEILING Ee T ED A A A A A A A A A A A A A A A A A AG 7 Ye H WASHER LOCK NUTS RUNNING THREAD CEILING i LOOP CANOPY TT CRYSTAL COVER EEEE EEEE SC
3. be responsible for unprofessional wiring Installation Please read all instructions carefully Before you proceed to install make sure that the power supply is turned off and remains off until installation is complete please note that each part has been assigned a number please proceed in a numerical order
4. etween parts The part Numbers coincide CAUTION 1 Rated 110v 130v 60Hz bulb E12 40W maximum 2 Care Should be taken to avoid damage to the surface of lighting and wire wearing gloves is recommended when installing 3 Connect black or red wire of the lighting to live wire and white or blue wire to neutral wire and double colored or bare copper wire to ground wire 4 Never install lighting on damp ceiling the room should be dry and well ventilated D Keep lighting away from acid alkali and other corrosive chemical or gas clean the lighting with Clean soft cloth only 6 Installation must be carried out by qualified electrician only 7 Disconnect the power before installing Ceaning and replacing lighting 8 Never cover the lighting when power is connected 9 Firmness must be secured when installing ceiling tube chain pipe and other connecting parts 10 Care should be taken to avoid damage when installing glass parts 11 All electrical components must be installed by a licensed electrician and in accordance with the National Electrical Code and the appropriate local electrical codes Make sure that the elecrtrical supply to the chandellier is turned off at the main fuse or circuit breaker before doing any installation Worldwide lighting shall not be responsible for unprofessional wiring Crystal Dressing Diagram When dressing the chandelier with the crystals please remember to wear either rubber or cotton
5. gloves So as to prevent any damage or smudging on the crystals ZRNI RO OSD SKN J a w Al ZENo N a A A R aa Fa G w Gr G C 7A f oe a _ 4y iy G Cea FIN D1 CTS P hh EENS V A NVV VY WAAAY ne SOO COO OODI XK IX 74584 Mh nee AN WA Frame Assembly Diagragram I TS Ss S eg an a SSS i AC gt S Sas Ns ES ae r ae ET IL rere CANOPY INSTALLATION INSTRUCTIONS MAKE SURE POWER IS DISCONNECTED Attach washer to supporting member in ceiling sufficient to support weight of fixture Slip screw collar prismatic cover and metal canopy over chain Determine the suspension length of the fixture and cut chain if necessary Use two connecting links to attach chain to chandelier loop and ceiling loop Insert stem wire through chain and ceiling loop Connect wires Fixture MUST be grounded Check distance from ceiling to loop to assure canopy assembly will be flush against ceiling Attach canopy to ceiling with screw collar WARNING CONTENTS ARE FRAGILE HANDLE WITH CARE The metal frame and crystal components of this chandelier are very delicate Please excersise extreme Caution during unpacking and installation WARNING After passing the main eiectrical wire through the 10mm pipe and connecting the p
6. ipe to the main body top connector place all remaining pieces as shown in nurmerical order and in the orientation depicted Refer to the parts list to avoid confusion between parts The part Numbers coincide CAUTION 1 Rated 110v 130v 60Hz bulb E12 40W maximum 2 Care Should be taken to avoid damage to the surface of lighting and wire wearing gloves is recommended when installing 3 Connect black or red wire of the lighting to live wire and white or blue wire to neutral wire and double colored or bare copper wire to ground wire 4 Never install lighting on damp ceiling the room should be dry and well ventilated 5 Keep lighting away from acid alkali and other corrosive chemical or gas clean the lighting with Clean soft cloth only 6 Installation must be carried out by qualified electrician only 7 Disconnect the power before installing Ceaning and replacing lighting 8 Never cover the lighting when power is connected 9 Firmness must be secured when installing ceiling tube chain pipe and other connecting parts 10 Care should be taken to avoid damage when installing glass parts 11 All electrical components must be installed by a licensed electrician and in accordance with the National Electrical Code and the appropriate local electrical codes Make sure that the elecrtrical supply to the chandellier is turned off at the main fuse or circuit breaker before doing any installation World wide lighting shall not

Download Pdf Manuals

image

Related Search

Related Contents

  6768 - MAN MP2100 TH FI USR PT Miolo  User Manual HealthPro® Series HealthPro® Series  盘古I3-B 3D打印机使用手册  NIGHT VISION BINOCULARS  103074 - Online  LauraM_manual_EN  Dvico Slim S1 Duo 1TB    

Copyright © All rights reserved.
Failed to retrieve file