1. W 83039C16 D16 H15 L6 We are dedicated to providing the finest quality crystal chandelier for our customers Our master craftsmen and designer pride themselves on their attention to detail prompt efficient service is our priority Enclosed are detailed instructions on how to properly install your chandelier Please read all instructions carefully and thoroughly If you have any questions please fell free to call our toll free DHANDELIER HOTLINE AT 1 859 411 8999 C US Crystal Dressing Instructions CANOPY PARTS LIST W83039C16 When dressing the chandelier with the crystals please remember Existing Electrical Box to wear either rubber or cotton gloves So as to prevent any damage or smudging on the crystals Crossbar Screws 14mmX6 Crossbar Screws x 2 not srpplied Lamp pole l4mX3 LD 40mmxX 1 Wy AN 40mmX1 A NO Quantity A 7strings Wire Connector 7strings strings QO de Shrinkable tube 14mmx7 amp 14mmX4 14mmX2 gb strings a 7strings 7 Cable tie 6strings lstring Ground Wire our 7strings strings CANOPY INSTALLATION DIAGRAM Frame Parts List 03 Crossbar 04 Canopy GoTo 05 Chains 02 Lamp pole 01 Lamp Body WARNING Crystal Dressing Diagram CONTENTS ARE FRAGILE HANDLE WITH CARE The metal frame and crystal components of this chandelier are very delicate Please excersise extreme Caution during unpacking and installation
2. When dressing the chandelier WARNING with the crystals please remember to wear either rubber or cotton After passing the main eiectrical wire through the 10mm pipe gloves So as to prevent any and connecting the pipe to the main body top connector place damage or smudging on the crystals all remaining pieces as shown in nurmerical order and in the orientation depicted Refer to the parts list to avoid confusion between parts The part Numbers coincide CAUTION 1 Rated 110v 130v 60Hz bulb E12 40W maximum 2 Care Should be taken to avoid damage to the surface of lighting and wire wearing gloves is recommended when installing 3 Connect black or red wire of the lighting to live wire and white or blue wire to neutral wire and double colored or bare copper wire to ground wire 4 Never install lighting on damp ceiling the room should be dry and well ventilated 5 Keep lighting away from acid alkali and other corrosive chemical or gas clean the lighting with Clean soft cloth only DA 6 Installation must be carried out by qualified electrician only FON NVAVAW 7 si T Disconnect the power before installing Ceaning and replacing W Sins Fa lighting 8 Never cover the lighting when power is connected L RS aS AN I WSL ne ANZ WIA ZEN MSA H WYW Z5o amp WW WA MN SA V7 WWW w WY LOS 9 Firmness must be secured when installing ceiling tube chain pipe and other connecting parts 10 Care
3. e installed by a licensed electrician and in accordance with the National Electrical Code and the appropriate local electrical codes Make sure that the elecrtrical supply to the chandellier is turned off at the main fuse or circuit breaker before doing any installation World wide lighting shall not be responsible for unprofessional wiring Frame Assembly Instructions Installation Please read all instructions carefully Before you proceed to install make sure that the power supply is turned off and remains off until installation is complete please note that each part has been assigned a number please proceed in a numerical order Install Lamp Pole 02 on Lamp Body 01 Install Crossbar 03 with J Box and then Fixed the Canopy 04 Join the Lamp Body 01 and Crossbar 03 with Chains 05 Make sure the positive and negative charges of wire and Lamp Body 02 match correctly screw the connect point with the junction cap Make sure the main wire is enough long and keep the rest wire in the 4 J box As the crystal pressing instruction hang the crystal parts Install lighting Source
4. should be taken to avoid damage when installing glass LAN parts ORY i LAAN 11 A11 electrical components must be installed by a licensed YOO AN 2 WS s AN T KX WOOY electrician and in accordance with the National Electrical Code C WAY Ah ARSA S NS AN j Woy and the appropriate local electrical codes Make sure that CN g Oy the elecrtrical supply to the chandellier is turned off at the D ROY main fuse or circuit breaker before doing any installation Worldwide lighting shall not be responsible for unprofessional wiring F Frame Assembly Diagragram CANOPY INSTALLATION INSTRUCTIONS Please read all instructions carefuly Before you proceed to eu install make sure that the power supply is turned off and off until installation is complete Please note that each part has been asigned a letter Please proceed in an alphabetical order A Existing Electrical Box B Crossbar C Crossbar Screws D Metal Plate E Crossbar Bracket F Neutral Conductor G Hot Wire H Junction Caps I Ground Wire J Wire OXA dl RY H F Attach the Crossbar B to the existing electrical box Ausing the two crossbar screws E which are not supplied and should already be in your box gp as LIN ASAN ja eo A M db d a ASA Wy KEN as Gis gD Ir ON 7 ED gt LS Wy W V VV JER lt gt D gt AVIA SO RY LEX IS NYY AAAAN de gt Wy W V AA lt WW ASON oh ASS we MAIN ZX MAN WW ADA WW WW MANN SO V7 W
5. y WAAAY WARNING CONTENTS ARE FRAGILE HANDLE WITH CARE The metal frame and crystal components of this chandelier are very delicate Please excersise extreme Caution during unpacking and installation WARNING After passing the main eiectrical wire through the 10mm pipe and connecting the pipe to the main body top connector place all remaining pieces as shown in nurmerical order and in the orientation depicted Refer to the parts list to avoid confusion between parts The part Numbers coincide CAUTION 1 Rated 110v 130v 60Hz bulb E12 40W maximum 2 Care Should be taken to avoid damage to the surface of lighting and wire wearing gloves is recommended when installing 3 Connect black or red wire of the lighting to live wire and white or blue wire to neutral wire and double colored or bare copper wire to ground wire 4 Never install lighting on damp ceiling the room should be dry and well ventilated 5 Keep lighting away from acid alkali and other corrosive chemical or gas clean the lighting with Clean soft cloth only 6 Installation must be carried out by qualified electrician only T Disconnect the power before installing Ceaning and replacing lighting 8 Never cover the lighting when power is connected 9 Firmness must be secured when installing ceiling tube chain pipe and other connecting parts 10 Care should be taken to avoid damage when installing glass parts 11 All electrical components must b