Home

Global Water G5CTRO Use and Care Manual

image

Contents

1. e uM 59965999999990 Se See See Sere eee eT e087 Feed Waterin 00 0 LPL SR RELA SRL AL SL SSSA ER SSE SSE RSI REE REEDS SOS SCS SSR SS SHES SSF e STS Sere eee ere ree N I III L ELELLERSLELELL EL LLLO CeCe SIF eer eee ere e8 8 4 dd SE Tee TIS Sere eee ere ee FESO CS STS TSS KTR Se Tee Te ee eee md U DILID init UL SA LEE ELA IRAP pa 9999919999 Ttt See eee eer eer e reeset 1 4 Flastic Tube al Figure 4 Water Cooler Connections 9 Page Feed Water Connections To connect the feed water use the supplied self piercing saddle valve to connect to the cold water supply line under the sink Attach the 1 4 inch tubing to the compression fitting on the side of the valve Clamp the saddle valve over copper or plastic feed line cold water only Turn the handle on the valve until the needle stem pierces the tube Then retract the needle 1 2 turns to start water flow See Photo inset Valve with Piercing Point A I 1 4 Line to Cooler Copper Water Line Saddle Valve 10 Page Drain Connection Applies to models with Reverse Osmosis RO only The drain line in the back Fig 4 must be hooked to the drain line ahead of the normal sink water trap See Figure 5 below Place the 2 part drain saddle on the drain pipe before the drain trap Allow proper space for the drilling operation Tighten the saddle bolts evenly on
2. qu E o 4f et OA lE D ai MODEL G5CT COUNTER TOP OPERATION MANUAL Please read these instructions completely before operating this unit Table of Contents TOQUE Olum ORE pg 3 aisle ziii ofer pg 4 Description Model G5CT Counter Top eene pg 5 OOperati6llo suu 1 000101012121 1 Wap RR pg 6 7 Positioning the COO ON doro En ve etit Do eerte Pu bt dem pg 8 Water Cooler COMNECHIONS iod iere ipii oue mutita a Da inet pg 9 reed Water 0 0 Sees Gb h Qaya ei dde pg 10 Drain CORN EE UO 1 1 1 1 a bia bise dvds dud pg 11 EZ CODBeCLIOTIS oui cmi ibat RE PO a ua a cipe s haba pg 12 Start DEUS hie 1 xu Dum evade SEOs o pg 13 Eu Sidi err pg 14 Cleaning and Mairtehnali6e s u u bou eats REFS Ip Quy udi dietus pg 15 SaHilblZablO l 0 p g 16 Filter Replacements aee itd eas E ER u u A Grete pg 17 Reverse Osmosis Membrane Replacement pg 18 Troubleshooting ca u 2 ire uu de i i No v C Eve d Odo tons G una rH d s pg 19 SDE CINICA TIONS CESS OS SERS pg 20 AI CE pg 21 List of Figures Figure 1 Assembly Drawing Model G5CT pg 5 Figure 2 Faucet Operation pg 6 Figure 3 Hot Cold Power On Off Switch pg 6 Fi
3. The RO assembly is comprised of a 5 micron sediment filter a carbon GAC 10 micron filter CSM RO membrane and a post carbon filter to improve taste The RO filter assembly requires a drain line connection to be installed which removes rejected water to the sewer The F assembly is comprised of sediment and carbon filter system but not the RO membrane therefore it does not require a drain line connection CAUTION The filter version F must be used only with softened water or water that has less than 3 5 grains of hardness to prevent scaling and premature burnout of the heating elements Please read all the instructions in this manual before operating this unit 3 Page Receiving the Cooler Unpacking Global Water products are shipped completely assembled and ready to operate Remove the top of the box and slide the water cooler out and save the box and packing materials Inspection Inspect the cooler for shipping damage Look at the exterior panels to see if they have been dented or damaged Check the dispensing spigots in the front Open the bottom panel to assure that the filter system is intact Look at the back of the cooler to see if the compressor is secure and has not broken from the mounting Inspect filter system to see that nothing is damaged or dislodged from shipping Description Model G5CT The G5CT Model provides water at 3 different temperatures dispensed from three spigots hot cold and
4. ambient The assembly drawing is shown in Figure 1 Water flows from the filter system into the ambient tank and the cold water tank simultaneously The cold tank then feeds the hot tank which is heated by internal heaters The level in the cold water tank is controlled by a float valve mechanism which controls a 4 way auto shut off valve on the water feed line to maintain a constant level of filtered water Both models are available with reverse osmosis RO or standard filter F versions 4 Page Description Model G5CT Counter To Lid of Cup Holder IC Board Control Panel Gold Water Tank Drip Tray Hot Water Tank Figure 1 Assembly Drawing Model G5CT Counter Top 5 Page Operation When installation is complete the unit will fill up with water and shut off when the tanks are full Plug the unit in to an outlet and press the cold hot faucets until a steady stream of water comes out Figure 2 Faucet operation Make sure the tanks are filled with water before continuing to cold power switch the next step hot power switch Turn on the hot cold switches located on the back of the cooler Both hot cold elements will begin chilling and heating the water inside the unit Indicator lights will also illuminate of the front of the cooler Figure 2 Hot and cold power on off switch 6 Page Operation Cont To dispense water from the Hot faucet press the safety lock on
5. both sides Using the opening in the drain outlet saddle as a guide drill a 1 4 hole in the drain pipe Clean any debris out of the drain saddle connection Connect the drain line to the cooler using the 1 4 black tubing supplied i M amp y VERTICAL SINK f MOUNT L DRAN LINE a oe I FROMAIR GAP do o5 vy m ud AIR GAP ONLY BN me DISPOSAL b f gi b Ae B ad Qr recen I lt 4 DO NOT INSTALL HERE S ergo T 5 OT INSTALLHERE s 34 HORIZONTAL j SZ Zf wow 3 Er e hha ue gt E MAXIMUM DISPLACEMENT 8 if ke FROM TOP CENTERS RII 534 Z S lis Horizontal Drain Line Vertical Drain Line 0 Locate drain hole as close as possible to top of pipe Locate drain hole on a straight length of drainpipe next to between 45 and top and as far as practical from P S trap between trap and sink garbage disposal Figure 5 Drain Connections for RO models 11 Page EZ Connections The standard tubing connections on the water coolers are EZ connect fittings Use the tubing and follow the instructions below in fig 7 to make the connections If you cut the tubing make sure it is a square cut fits squarely in the fitting and seals properly Cut the tube square Stainless Steel Teeth Cut the tube square It is essential that the outside diameter is free of score marks and that burrs a
6. ce and then press the hot water button below it C HEATING CHLUNG Het Water Button Room Water Button Cold Water Button Cold Power Indicator Hot Power Indicator t a E HEATING CHILLINS Heating System Indicator Chilling System Indicator 7 Page Positioning the Cooler 1 It is not recommended to install this cooler in an area were water may cause severe or costly damage 2 Do not position the cooler where it can be hit or bumped by Vacuum cleaners or floor waxing machines This can cause breaks in the waterline connection fittings and compressor tubing Leave a space no less than Keep the machine away from 15cm between the wall and sunlight heat and wetness dispenser Be sure to use single outlet socket with correct power voltage Plug the power cord directly into electrical socket 8 Page Water Cooler Connections When you receive the water cooler the water connections on the back have of the cooler have tube plugs in them These tube sections must be removed before making all your connections To remove the tube sections see figure 7 Disconnect The 1 4 plastic tubing should be used for making the Feed Water The drain connection for RO models will come off the separate filter pack If hard copper tubing is used for the Feed Water and Drain connections the bulkhead fittings must be changed to a metal fitting ON A nM o 2 2 2
7. d Stage carbon filter P N TWSET 3rd Stage post carbon filter f Twist new filters on the housing brackets g Open ball valve and let water flow through filters when the cooler is full empty out the water into a bucket This will eliminate the first batch of water which is full with carbon fines h After the cooler fills up again turn on the power to the cold and hot tanks Wait a few minutes to assure there are no leaks and close the filter door 17 Page Reverse Osmosis Membrane Replacement RO versions RO every 3 years a Use the same procedure as above sec a c b Remove the RO stage from the clips Disconnect the white tubing from the RO housing cap c Remove the cap from the housing by unscrewing it d Using a pair of pliers remove the RO element from the housing by grasping the tube end and pulling it out e Use RO filter replacement P N CSM50 50gpd Insert the element into the housing with double o ring end going in first toward the bottom of the housing Make sure the o rings are sealed Replace the cap Reconnect the white tubing Proceed as in above sec g O Ring Seals N Membrane Housing Figure 8 RO Membrane Installation 18 Page Trouble Shooting Guide CAUSE SOLUTION Cold Water not cold enough Hot Water doesn t flow out of spigot Panel not lit No hot water at start up No electric current flowing The cooler is placed too close to the wall Wire Condenser on backs
8. gure 4 Water Cooler Connections eese pg 9 Figure 5 Drain Connections for RO Models pg 11 Figure 6 Filter Configuration Model FP pg 13 Figure 7 Back View of Coolers nennen pg 14 Figure 8 RO Membrane Installation a pg 18 2 Page Introduction Congratulations on your purchase of our revolutionary Bottle less Water Cooler Our coolers are all designed to replace the conventional 5 gallon water bottle while eliminating the hassles of deliveries lifting bottles and eliminating plastic bottles from landfills Our coolers are designed to produce pure great tasting water for the whole family that is clean and safe to drink Our coolers are connected to your city or well water supply to efficiently filter out tastes and odor and to remove microscopic contaminants by using reverse osmosis purification technology We manufacture a wide range of models to fit any home or office application The G5CT Counter Top has 3 temperature faucets cold water is chilled around 442F hot water is heated at 1802F and ambient All Global Water models are manufactured and marked as RO or F assemblies The RO assembly utilizes CSM Reverse Osmosis water purification technology which produces pure safe water from city or well water
9. ical float valve to control flow to the tank The unit does not have to be plugged in to start water flow Water will flow into the ambient cold and then the hot tank as well Let cooler tanks fill with the filtered water until full about 1 hours for the RO version about 10 15 minutes for the F version Observe the water level when full and see that water input to the tank stops when it is full Adjustable Hot Cold Cold Water Thermostat Switches 1000 Models Warmer Colder Water In Connection From Supply Drain Water Figure 7 Back view of the Cooler Water Connections Model G5CT 14 Page Cleaning and Maintenance Cold Water Tank Lid 1 Please make sure the machine is completely disconnected from electricity before cleaning ni Hee UIT Remove the top cover by water stop bolt unscrewing the screws of left and right side plates 3 Pull out water stop Open the interior lid of cold bolt which can water tank shown by the completely drain out arrows and take off the water in cold water insulator board Press cold and hot water tanks and hot water buttons to let water drain out completely 15 Page Sanitize Fill main water tank with water Add 1 2 teaspoons of liquid chlorine bleach Let stand for 5 10 minutes Drain the water then let water from filters refill tank and drain a second time Remember to drain from dispensing spigots also Note Upon completion of cleaning wa
10. ide is dusty Compressor does not have enough refrigerant Air may be trapped in the line Controls not set Hot tank overheat protection sensor tripped Make sure the cooler is plugged in and check for improper connections Provide a minimum of 5 space between wall and back of dispenser Clean wire condenser every three months Place cooler in a well ventilated area Adjust thermostat Hold the spigot down for 30 seconds to relieve air Turn cold temperature switch on at back Check that the power cord is in the socket and turn on the cold hot buttons on the back of the cooler to the on position 1 Unplug cooler 2 Let sensor cool down for 1 hour 3 Reach through cooling grill with pencil or narrow screwdriver to press nude color reset button on upper sensor located on the hot tank Note In the event of problems beyond the scope of the troubleshooting described in the manual please call your selling dealer 19 Page Specifications Ambient Tank Capacity Cold Tank Capacity Power Consumption Hot Water 500W ola Water 100w Electric Power Cord Length 20 Page Warranty All Global Water products are warranted to be free from defects in materials and workmanship under normal use within the condition of operation listed for a period of 1 year from date of purchase The compressor has a 3 year warranty There is no liability assumed by the company for damage d
11. it at least 10 minutes after the power cord is plugged in before turning on the Hot and Cold Water buttons 3 Pull out water stop bolt to drain out water from water tanks Water Stop Bolt EI cun pipe gn n i A em m 1 a CE SC m TNR no RS lt _ lt mi i ko EVO IEEE M 16 Page Filter Replacement The filter elements must be replaced at regular intervals to maintain the quality of the water The GSCTF has 3 stages of mechanical filtration 1st stage 5 micron sediment filter 2nd stage activated carbon filter and a 4 stage post carbon filter The filter elements in all stages must be replaced every 6 months The G5CTRO model has the 3 stages of filtration plus an additional Reverse Osmosis membrane filter The 3 pre filters must be replaced every 6 months The Reverse Osmosis membrane must be replaced every 3 years Replacement Procedures Filtration Versions F G5CTF Coolers a TURN OFF POWER TO HOT COLD ELEMENTS b Swing open the front hinged cover c Close the ball valve to stop water flow through the filters d Place a towel under the filters to catch water The filters will have water in them which will run out when the filters are unlocked e Twist the filters to remove them from their housings f These filters are disposable encapsulated filters Remove and discard the entire filter body Replacement filters are sold as a set 1st Stage sediment filter 2n
12. nd sharp edges be removed before inserting into fitting For soft thin walled plastic tubing we recommend the use of a tube insert Insert tube Fitting grips before it seals Ensure tube is pushed into the tube stop Push up to tube stop Push the tube into the fitting to the tube stop The collet gripper has stain less steel teeth which hold the tube firmly in position while the O ring pro vides a permanent leak proof seal Pull to check secure Pull on the tube to check it is secure It is good practice to test the system prior to leaving site and or before use Push in collet and remove tube Push Collect in Disconnect To disconnect ensure the system is depressurized before removing fitting Push in collet squarely against face of fitting With the collect held in this position the tube can be removed 12 Page Start Up Flush If you order our ro model you will receive a large white tank and a separate box that containers the filter pack Unpack both of these and set them up near the cooler Our f models do not have the tank Now you have to connect the water line to the filter pack which can be found on water feed connections page When the water runs off the last filter connect one tube to the white tank and the other tube to the back of the cooler To flush the filters disconnect the tube from the 2nd stage carbon filter circle in figure below and place a cup or pan right underneath the hole t
13. o catch water Open ball valve inside the cooler 1 4 turn handle in line with tube is on and let water flow through filters into the bucket or pan Split this line to the cooler and to the tank Water Line Mur vari ie SS AC at TDI S a W iY 7 i a ra A Connect the black tube for reverse osmosis to the drain This can be found on Figure 5 to push out air and carbon fines When water runs clear turn off ball valve and re connect the tube to the filter Turn on the water to the filter system by opening the ball valve inside the cooler 1 4 turn handle in line with tube is on Check all connections to assure there are no leaks Figure 6 Filter configuration 13 Page Tank Flush Flush tanks out by draining all water through the 1 drain plug located on the back of the cooler and drain water through the dispensing spigots Fill and empty the tanks 3 times with the filtered water this ensures great tasting water When the tank has filled again with filtered water the cooler is ready to dispense water You may now turn on the Hot and Cold buttons on the back of the machine NOTE You should always turn on the Hot and Cold elements when they have water inside the tanks CAUTION DO NOT TURN ON HOT OR COLD POWER CONTROLS YET Remove the top cover of the cooler by removing 2 screws from back of top cover Pull the cover off exposing the main tank This model uses a mechan
14. ue to water leakage or other secondary effects from any component defect Labor is not covered in this warranty The warranty applies when Conditions of Operation below are met Conditions of Warranty Water System Pressure 35 100psi Temperature 40 100degrees F Water PH range 4 10 Max TDS 1500 PPM Turbidity lt 1 0 NTU Water Hardness 20gpg Iron 0 1 mg l Manganese 0 1 mg l Hydrogen Sulfide 0 00 mg l For filter only systems F models water hardness must be less than 3 5 grains or 60 mg liter 21 Page C r LAY BNL yl Cleaner Healthier Water 2031 SW 315 Ave Hallandale Florida 33009 www GlobalWaterInc com Tel 786 235 2518 Fax 786 207 2570 Email GlobalWaterFlorida Gmail com 22 Page

Download Pdf Manuals