Home
IHeat S-14 Use and Care Manual
Contents
1. COPPER 240VAC 60AMP 6 2 AHQD 1100 COPPER 240VAC S 9 40AMP 8 2 AHQD 1100 COPPER 240VAC 8 7 30AMP 8 2 AHQD 1100 COPPER 240VAC 8 4 30AMP 8 2 AHQD 1100 COPPER 120VAC IMPORTANT PLEASE READ ALL OF THIS IMPORTANT SAFETY INFORMATION IN THIS BOOKLET This booklet contains important information amp operating instructions for your tankless electric water heater The example general information contained in this booklet is for guidance only Please read it carefully in its entirety and retain it for use later as well Tankless water heaters are safe and can be used with less risk than conventional water heaters This is provided that they are installed used and maintained in good working order using common sense The unit installation must be carried out by qualified personal and in the proper sequence listed in this booklet An example supply list is on the back cover Care taken during the installation will provide a long trouble free life for your heater PLEASE FOLLOW ALL RECOMMENDATIONS AND LOCAL CODE REQUIREMENTS FAILURE TO FOLLOW PROPER PROCEDURE IS HAZARDOUS IT CAN ALSO DAMAGE THE HEATER AND VOID THE WARRANTY TURN OFF ELECTRICAL SUPPLY MAIN AND WATER SUPPLY BEFORE ATTEMPTING ANY INSTALLATION DO NOT TURN ON ELECTRIC OR WATER SUPPLY UNIT INSTALLATION IS PROPERLY COMPLETED DO NOT remove the Heater cover open the unit or break the seal This could
2. Drakken Electric Tankless Water Heater S 16 S 9 S 14 OS7 e S 12 e S 4 TECHNICAL ASSISTANCE PLEASE CALL 1 888 818 4328 Drakken 790 West 20th Street Suite 103 Hialeah Fl 33010 Tel 305 556 5266 Toll Free 1 888 818 4328 PRODUCT MANUAL www drakkenusa com 6 There is overheat protection function While the outlet temperature reaches 158 F 70 C the heater will pause working automatically only after the temperature dropped to 104 F 40 C it will recover to work 7 There is screensaving function the display screen will light off without operation in 30 seconds and the display screen will light up again while there is operation ELECTRICAL INFORMATION VERIFY ALL VOLTAGE amp AMPERAGE INFO LISTED BELOW WITH THE ACTUAL LABEL SPECIFICATIONS ON YOUR UNIT FOR ANY CHANGES OR VARIATIONS ALL SPECIFICATIONS ARE APPROXIMATE AND SUBJECT TO CHANGE WITHOUT NOTICE 12 208 208 38 13 4 220 S 9 220 41 16 240 240 44 11 5 208 29 12 9 220 220 31 15 3 240 240 11 208 3 2 110 S 12 12 4 220 S 4 3 5 120 14 7 240 WIRE GAUGE AND BREAKER SIZE CAN VARY BASED ON A NUMBER OF FACTORS INCLUDING SUPPLIED VOLTAGE AND LENGTH OF CIRCUIT CHECK LOCAL REQUIREMENTS Installation Schematic for S Series Heaters Disconnect 1 2 Ball Valve F Voltage C Wire from main service panel B c D E F 7OAMP 6 2 AHQD 1100 COPPER 240VAC 60AMP 6 2 AHQD 1100
3. Y and damage the Heater DO NOT SOLDER NEAR HEATER INLET OR OUTLET SOLDER ALL CONNECTION PIPES AWAY FROM THE UNIT AND SOLDER THE FINAL JOINT S AT LEAST 12 AWAY FROM THE HEATER NEVER USE PIPE INSULATION OR WRAP OF ANY KIND ON HEATER INLET OR OUTLET PIPES Never use Pipe Dope or Sealants Use Teflon tape only if necessary on heater inlet amp outlet All water heaters require a water supply line shut off valve A second shut off valve on the outlet side will eliminate any back feed of cold water should Heater removal ever be necessary Ball valves are recommended NOTE An expansion tank required by some recent code revisions for tank type water heaters is not usually required for tankless water heater installations Please check with your local codes to verify this It is recommended that a Clear Canister amp Sediment Filter be Installed on the inlet water supply side of the tankless water heater between the Heater inlet and the water supply valve This filter can reduce sediment and debris over a period of time from plugging the inlet fine mesh screen This will also provide cleaner water for showers washers etc These are available from your tankless dealer Flush Incoming supply pipe after soldering amp before connecting Inlet to Heater Avoid having debris such as excess flux or solder from plugging the visible water inlet screen If it becomes restricted the Heater will not operate properly and the screen must be cl
4. and adjust to desired comfort outlet temperature During winter the incoming water supply maybe cooler than in Summer The heaters thermostat control knob maybe readjusted to compensate up to its rated capacity Make sure that all electrical and plumbing connections are securely connected to prevent overheating Contact customer service for customer support about any concern or if any of the following occurs If the unit experience a distinct change in performance the unit is or has been frozen or the Heater is to be operated at pressures above75 PSI Turn off power to Heater immediately if water ceases to flow during use Switch off the heater unit at the Service disconnect and at breaker s when not is use for extended periods or upon any concern This is for all electrical appliances and devices Risk of electrical shock for heater used the first time or not used for a long period let water go through it turn on the power and then operate it according to the manual Operation Instruction Turn on the circuit breaker to bring electrical power to the unit After the unit is supplied with power turn on the water and then the heaters will start work The min water flow to active the unit is 0 53GPM 2L min Turn off the water flow or press POWER the heaters will stop working Press HIGH and LOW to adjust outlet hot water temperature Every time press the key of LOW and HIGH the setting temperature will be 2 F up a
5. cause DEATH OR JNJURY and will VOID THE WARRANTY There are no user serviceable parts inside DO NOT Install Heater in a shower or anywhere it can be reached or adjusted by anyone while using water DO NOT Operate the unit if water ceases to flow during use Contact technical support for this or any other issue of concern on the web at www drakkenusa com or call 305 556 5266 or 1 888 818 4328 Although installation is simple DO have a licensed Plumber amp Electrician perform the installation COMPLY WITH LOCAL CODES AND PERMITTING PLUMBING INFORMATION 36 Inches of 36 Inches of copper Minimum copper Minimum Turn off Main Electrical Supply water main amp hot water supply before attempting the installation All plumbing should be completed before proceeding to electrical wiring connections Use 1 2 Copper Water Pipe for the Heaters inlet amp outlet lines If you have 3 4 or other size water pipe reduce to 1 2 before entering the inlet and enlarge from the outlet Use compression fittings to connect to Heater amp do not over tighten NEVER CONNECT HEATER DIRECTLY TO ANY TYPE OF CPVC PLASTIC PVC OR WATER SUPPLY PIPE If the location has PVC CPVC or other plastic pipe always install 36 of copper pipe to inlet and from outlet of heater to insulate Heater from any plastic pipe Make a U or L shape if necessary to equal 36 on inlet amp outlet Not using copper pipe will VOID THE WARRANT
6. clothes dryer etc The Heater must have a Service Disconnect that the electric pigtail can Be hard wired into Models with an amperage of 40 amps or less may not Require a Service Disconnection Check with your Code Inspector to verify what is required The Heater unit must be hard wired not a plug or socket outlet NOTICE REMARK e This appliance is not intended for use by persons including children with reduce physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Never install any stop valve in the outlet pipe line When you change the quick connect hose do not use the old hose again The max water pressure of the quick connect hose is 0 6 MPa The unit must be installed to independent breaker as per electrical diagram Do not let the children play with the unit i CIRCUIT BREAKER DOUBLE POLE The electric heating elements operate at a constant temperature hot water at your chosen temperature setting It is the rate of the water passing through the heater unit which determines the water temperature at any given setting The slower the flow less volume the hotter the water becomes the faster the flow gallons per minute equals cooler water Press POWER switch key to turn on off the heaters press the key of HIGH and LOW to adjust outlet temperature Test water
7. eaned MOUNTING ELECTRIC TANKLESS WATER HEATER Using the template which has been included in the package place template on the mounting surface make sure mounting surface is solid and secure and ensure when placing the template on the mounting surface that the placement is level prior to marking the screw positions After leveling mark the holes provided on the template onto the mounting surface Place wall anchors and or screws depending on the material of the surface then mount the unit upright as seen on the figure below We recommend that this product be installed in an upright position with the inlet and outlet water connections on the left side and right side unit using 1 2 compression fitting or NPT fitting Recommended Clearances Clearance to combustible materials should be kept at a minimum of 24 inches away from the unit and the outlet water connections MOUNTING BRACKETS ON BOTH SIDES 1 2 COMPRESSION 1 2 COMPRESSION FITTING 5 4 im ELECTRIC CONDUIT 10 Complete all Plumbing connections and test for leaks Operate a Nearby hot water tap to remove air from water line to avoid a Heater dry start e WATER OUTLET PRESSURE RELIEF VALVE JHEAT PADPLUS V G WATER INLET Lt J azea VALVE WIRE FROM MAIN SERVICE PANEL ELECTRICAL INFORMATION The following example information is for guidance only Please verify all supplied information with your local Building Code Inspector before proceedi
8. nd down in degree fahrenheit display status or 1 C up and down in celsius degree display status Temperature setting arrange is from 82 F 27 C to 140 F 60 C turn off the heater then press the key of HIGH or LOW to convert the temperature display between degree fahrenheit and degree celsius Page 3 Page 4 Page 5
9. ng with any installation Your requirements may differ from this supplied information WARNING PLEASE READ ALL INFORMATION The site locations Main Electrical Supply must be adequate to supply the Heaters electrical load requirement and all other existing circuits If your Main Electric Service panel has a rating below the required load amperage for this Heater unit and the existing circuits and or if there is no spare breaker space then the installation will not be possible It will re quire an upgraded Electric Service and a higher amperage Service Panel to service the location Before beginning any installation or attempting any Electrical connection make sure that the Main Electrical Supply Panel and any supply line breaker s are switched to the off position Be certain and test to verify that there is no electric current before attempting installation The Electric supply line wire Circuit Breaker and Service Disconnect if required must all be sufficient for the load Voltage and Amperage Deter mine the permissible circuit length and verify the correct wire and breaker size The Service Disconnect and electrical connections should be placed above or to one side of the heater Make sure that all electrical and plumbing connections are connected securely to prevent overheating The Heater must be connected to its own independent dedicated and PROPERLY GROUNDED electric circuit Heater MUST NOT share any Other circuit i e oven
Download Pdf Manuals
Related Search
Related Contents
ローレット木目25シングルセット Télécharger le PDF - Notaires de France Philips 5000 series Blu-ray Disc/ DVD player BDP5406 平成25年 4月 (PDF形式: 2,623KB) Rio Audio Rio 800 User's Manual 株式会社マミロボット・ジャパン Free Life With Innovative Technology L14 - Drive Programming with the New PowerFlex® 520 REGOLATORE AUTOMATICO DI RIFASAMENTO Manuale d`Uso Copyright © All rights reserved.
Failed to retrieve file