Home
Saniflo 017 Use and Care Manual
Contents
1. SANTOR IMPORTANT DO NOT RETURN ANY MERCHANDISE TO THE VENDOR NE PAS RETOURNER DE MARCHANDISE AU VENDEUR For Customer Service Returns or Technical Questions please call Saniflo s technical support toll free at 800 571 8191 USA or 800 363 5874 CDN Pour le service client les retours ou toute question technique merci d appeler le service technique de Saniflo au num ro suivant 800 571 8191 USA ou 800 363 5874 CDN The user should retain these instructions for future reference A lire attentivement et conserver a titre d information This product must be installed in strict accordance with local plumbing codes Product should be installed by a licensed plumber Le produit doit tre install dans le respect des r glements sanitaires locaux Le produit doit tre install par un plombier qualifi C US PE AN Ni A IC AN DN USA M NY INSTALLATION AND MAINTENANCE INSTRUCTIONS INSTRUCTIONS D INSTALLATION ET DE MAINTENANCE SANN TOP SANITOP PAGE 1 1 32 Pvc NOTE Please refer to section 2 1 Merci de vous conf rer la section 2 1 SANITOP SANITOP PAGE 2 PERFORMANCE feet pieds feet pieds 12 e 240 270 300 feet pieds VERTICAL DISTANCE DISTANCE VERTICALE A 90 min 14 US gallon min FLOW RATE DEBIT Floor Mounting Brackets SANITOP Type ST SFA SANIFLO 120 V 60 Hz 5 0A
2. outlet pipe to a sanitary sewer or soil stack Safety note For safety the macerating unit should never be activated with the lid removed EJ INSTALLATION 2 1 PREPARING THE MACERATING UNIT The plastic discharge elbow check valve assembly should be inserted long end into the rubber hose located on the top of the lid The step down rubber fitting should then be inserted at the discharge side of the elbow assembly and secured with the provided metal clamps The step down rubber fitting may need to be cut depending on the discharge pipe diameter Three metal clamps should be used to secure all fittings 2 2 CONNECTION TO A SINK e To connect to a sink use the elbow connector provided with the system Connect this fitting to the top inlet of the case and secure with clamps e f the inlet for the sink is not used plug the unused inlet with a blanking plug provided after greasing the joint 2 3 WATER CLOSET ASSEMBLY The tank comes with the fill and flush valve assembled however please ensure that all screws nuts etc are tightened 2 4 SYSTEM ASSEMBLY Sanitop See page 2 drawing 7a 1 Place the macerating unit in the desired spot and connect all inlet and outlet waste piping to the unit See Connection to discharge pipe work 2 Place the spigot outlet of the toilet bowl firmly against the white accordion connector and mark the floor through the holes in the bowl 3 Remove bowl and bore two holes approximately
3. 2 1 4 deep with a 5 16 masonry drill bit Insert plastic plugs into holes If the floor is wood bore a pilot hole with a 1 4 drill bit 4 Place the bowl in front of the macerating unit and pull the accordion gasket all the way onto the rear spigot outlet Attach with supplied gear clamp Check that gasket and clamp are even all around 5 Move the bowl over the holes in floor Slip the plastic china protectors over the lag screws Tighten lag screws do not over tighten and snap plastic cover caps in place 6 Locate the tank to bowl kit and place foam gasket on the spud of the flush valve and over nut Place tank on top of the bowl Insert screws and gasket through the tank and tighten nuts underneath Do not overtighten as this may damage the china The system is supplied with fixing lugs to prevent it from moving during use To optimize the latest technical developments concerning soundproofing incorporated into this unit it is important to e position the WC pan so that it is not in contact with a partition or wall of the room e place the WC pan on a perfectly level surface to ensure that the resilient mounts are fully efficient e fix the discharge pipe correctly with distances of not more than 3ft 1m between the fastenings 2 5 CONNECTION TO WATER SUPPLY Connect the water supply hose to the fill valve 2 6 CONNECTION TO THE DISCHARGE PIPE WORK These macerating units have an elbow and a step down bushing simp
4. 3 10 HP IP44 SANITOP SANITOP PAGE 3 SCHEMATIC DIAGRAM SANITOP SCHEMA DU SANITOP Parts Description 1 Case 10 Impeller PLUS TOP 20b Elbow clip 34 Tie wrap 48 Cable grip 33 1 2a Lid 11 Pump cover plate 25 Discharge elbow 35 Pan gasket 50 Spring clip assembly 2b Lid seal 12 Pump cover feet 26 Three outlet pipe 36 Screw clamp 90 110 56 Case feet 3 Motor 14 Pressure chamber 28a Discharge hose clip 25 40 37 1 1 2 Blankingplug 58 Plastic cap 4 Long grille 15 Membrane 28b Discharge valve hose clip 38 Condenser 45pf 61 Lateral grille absorber 5 Blade 17 Micro switch 32 55 39 Horseshoe clip 62 Upper grille absorber 7 Short discharge pipe 18 Cable insulator 31a 46 46 Rubber elbow AO Push rod 63 Lateral motor absorber 8 Long elbow 20a Ring for pump cover plate connector A1 Pressure chamber base 64 Fixation leg Composants de l appareil 1 Boitier 10 Turbine 20b Collier de maintien 35 Manchette WC 48 Serre cdble 33 1 Ja Ebiv rela 11 Fond de pompe 25 Coude d vacuation 36 Collier 90 110 50 Agrafe db Jeinkdisssuvatele 12 Pieds du fond de pompe 26 Manchon trois sorties 37 Bouchon 1 1 2 56 Pieds du bo tier 28a Collier coude 38 Condensateur 45 uF 58 Capuchon 3 Moteur 14 Chambre de pressostat d vacuation 25 40 39 Collier en forme 61 Amortisseur lat ral panier ki Foner ui 28b Collier coude clapet de fer cheval 62 Amortisseur sup rieur Couteau 17 Micro interrupteur d vacuation 32 55 40 Tige poussoir panier 7 Mini durite 18
5. Cela est ill gal et constitue un danger pour la sant Seuls les bran chements directs dans les syst mes de d chets sanitaires sont acceptables GEL Assurez vous que tout tuyau susceptible de geler est bien isol ou chauff Dans les immeubles non chauff s la toilette la tuyauterie et l ensemble broyeur pompe doivent tre prot g s contre le gel avec de l antigel de v hicule de plaisance ou vid s compl tement ELECTRICIT Avant d entreprendre des travaux d en tretien ou de d pannage il faut d bran cher l appareil de la source d alimentation en lectricit Le syst me de broyage doit tre prot g par un coupe circuit en cas de d faut de mise la terre du neutre FA GUIDE DE D PANNAGE PROBL ME Le moteur tourne normalement mais l eau s vacue lentement de la cuvette chasse d eau incompl te Les d chets s accumulent dans la cuvette Le syst me de broyage ne d marre pas L eau ne s evacue pas Le moteur ronronne mais ne tourne pas L eau ne s evacue pas L eau s evacue lentement et le moteur fonctionne par intermittence L eau s evacue du cabinet mais le moteur fonctionne tres longtemps et le rupteur thermique est active Apres l vacuation le moteur redemarre plusieurs fois avant de s arr ter completement Le moteur tourne bruyamment sans s arr ter ni pomper Apr s l vacuation le moteur tourne s arr te et red mar
6. Isolant du c ble 31a Coude 46 46 41 Base de la chambre 63 Amortisseur moteur 8 Long coude 20a Joint de fond de pompe 34 Tie wrap de pressostat 64 Patte de fixation SANITOP EE INTRODUCTION This macerator is manufactured in a factory which is quality certified to ISO 9001 2000 accredited by AFAQ This equipment benefits from the latest technological innovations concerning soundproofing To benefit fully from the advantages provided by this new generation of appliances it is important to comply with the installation instructions 1 1 GENERAL DESCRIPTION The macerating unit is a residential pumping system for a toilet and a sink The system is comprised of three major components the macerating unit which connects to the outlet of a rear spigot outlet toilet The toilet bowl The toilet tank The macerating unit also consists of three major parts the container which houses the operating mechanism a pressure chamber which automatically activates and deactivates the induction motor which drives the cutting blade and the impeller The macerating unit can simultaneously receive wastewater from a sink and a toilet only one water closet per unit Macerating units are designed for the disposal of human waste toilet paper and water They are not intended to be used for the disposal of kitchen waste neither are they intended to be used for the disposal of waste water from such pump appliances as dishwashers and clothes washer
7. care 5 4 CAUTIONARY NOTE Do not immerse unit totally in water Do not let water enter the electrical cord entrance opening 5 5 REASSEMBLY OF THE LID When replacing the lid grease the rubber gasket lightly with soapy water or dishwasher liquid Do not use Vaseline as this may expand the neoprene materials The gasket must be inside the lid first Start by pushing the lid down at the cord side first then work your way around and tap on the lid with a rubber mallet or bloc NS US KJ ADVICE PIPE SUPPORTS All on pipe work must be supported In accordance with the pipe manufacturer s recommendations Avoid dipping or trapping which may cause the build up of residual solids and sub sequent blockage BENDS Where ee long sweeping bends should be used Do not use short elbows If sweeping 90 elbows are not available use two 45 elbows to make a 90 turn VERTICAL INSTALLATION FIRST lf vertical lift is required this must precede the horizontal pipe run DIRECTLY VERTICAL All vertical lifts should rise as directly above the unit as possible allowing only for the need to clear the toilet tank Any initial horizontal pipe run from the unit prior to a vertical lift should not exceed 12 18 inches EASY ACCESS The unit should be accessible and removable in the event of maintenance being required During the installation TA a full port ball valve should be installed at the base of any ver
8. composants en plastique et en n opr ne de la soupape de remplissage et de la soupape de chasse d eau ce qui peut causer des fuites En cas de panne de courant n utilisez pas le cabinet ni les autres appareils sanitaires qui y sont reli s car ils ne fonctionneront pas tant que le courant n aura pas t r tabli L appareil s utilise comme un cabinet ordinaire et ne demande pas d entretien s il est utilis normalement Cependant il n est pas mauvais de nettoyer l ensemble broyeur pompe une fois par ann e N utilisez pas de javellissant Veillez a ce qu il n y ait pas d eau qui p n tre dans l ouverture du cordon lectrique L appareil se met automatiquement en marche d s que la chasse d eau est tir e ou que le lavabo se vide Il cesse de fonctionner lorsque son contenu a t pomp et vacu Si vous pr voyez de ne pas utiliser le cabinet pendant une longue p riode vacances panne de courant entretien etc fermez l admission d eau du r servoir et tirez la chasse d eau pour vider l appareil Il ne faut jamais laisser l eau du r servoir fuir dans la cuvette Dans les r gions ou il y a risque de gel le cabinet doit tre protege adequatement contre le gel Cela signifie vider tous les tuyaux le reservoir du cabinet la cuvette et le reservoir du systeme Pour proteger le systeme de broyage contre le gel il suffit de verser 1 litre d antigel pour appareils de plomberie dans le r servoir et de tirer la cha
9. d une douche un d une baignoire Ne connectez l appareil qu a une prise de courant prot g e par un coupe circuit en cas de d faut de mise la terre du neutre Attention risque de choc lectrique cet appareil est muni d une prise de terre GFI afin de r duire le risque d lectro cution V rifiez que votre appareil est branch sur un circuit lectrique avec prise de terre 2 9 RACCORDEMENT A UN SYST ME D A RATION Sanitop voir page 2 dessin 7c Cet appareil doit tre ventil Il est concu pour tre adapt a deux syst mes de ventilation Pour cela il poss de 2 orifices sur le dessus 1 calotte de 1 1 2 po et un trou de petite dimension L appareil doit tre reli a un syst me d a ration comme l exigent les codes locaux Placez le coude fourni sur la calotte et serrez le avec un collier fourni Connectez ensuite votre tuyauterie d a ration Tous les appareils connect s au syst me doivent aussi tre ventil s Attention N utilisez pas une vanne d admission d air ni un event a ressort car ces m canismes sont a sens uniques La pression d air doit demeurer uniforme a l int rieur et a l ext rieur de l ensemble broyeur pompe NOTE Le trou de plus petit diam tre doit tre bouch par le capuchon fourni i 2 10 MISE EN MARCHE DE L APPAREIL 1 Avant la mise en marche assurez vous que le cabinet ne contient pas de r sidus suite l installation Ouvrez la soupape d arr t et attendez que
10. de fabrication 3 La garantie ne couvre pas les frais de branchement et rebranchement de l installation c a d les frais de main d ceuvre qui sont la charge du client 4 La garantie ne couvre pas les frais d exp dition ou de transport quand une piece ou des pi ces de l appareil doit vent tre repare e s a l usine 5 En aucun cas la Compagnie ne sera tenue responsable des dommages accessoires ou indirects pertes ou blessures de quelle que nature que ce soit r sultant de l utilisation du produit ou de l un de ses compos ants 6 La garantie est transf rable seulement si l appareil demeure a l endroit ou il fut install initialement Sauf pour ce qui est des termes de cette garantie limit e la Compagnie n accepte aucune autre garantie implicite ou explicite ayant trait au produit ou a tout composant y aff rent incluant sans toutefois s y limiter toute autre garantie implicite quant a la valeur marchande ou l adaptabilit de ce produit a une fin particuliere Pour le service et d autres demandes de renseignements veuillez appeler a l une des adresses indiqu es ci des SOUS Etats Unis Canada SFA SANIFLO INC SFA SANIFLO INC 105 Newfield Avenue Suite A 1 685 Speedvale Avenue West Edison NJ 08837 Guelph Ontario N1K 1EG Num ro sans frais 800 571 8191 Num ro sans frais 800 363 5874 Anglais Num ro sans frais 800 877 8538 Francais T l phone 132 225 6070 Telephone 919 824 1134 T l copieu
11. de l avis de la Compagnie se trouve d fectueux ou ne r pond pas a la performance demand e du fait d un d faut de fabrication ou de mat riau Si le remplacement doit s op rer il sera seulement valable pendant les 180 premiers jours a compter de la date d achat Les r parations sous garantie seront applicables apr s cette date jusqu a la date de fin de garantie TERMES ET CONDITIONS Les conditions de la garantie sont e Le produit doit tre install conform ment selon l usage d crit dans les manuels ci joint e Le produit doit tre connect a une prise lectrique monophas e de 120V 60Hz et ne doit tre le sujet d aucune n gligence accident ou exposition a des produits ou des substances nuisibles e Le pr tendu d faut ou faute doit tre rapport soit a l installateur soit la Compagnie pendant la p riode de couverture de la garantie e La p riode de couverture de la garantie est valable 2 ans ECHANGE DE PIECE OU DE PRODUIT Le produit pourra tre chang sans frais uniquement au point de vente ou il a t achet sous reserve des conditions suivantes e Le client doit avoir une autorisation de retour chez le fabricant afin de valider l change e Le client doit produire une preuve d achat afin de valider l change RESTRICTIONS 1 Les m canismes de chasse et de remplissage du r servoir sont garantis par le fabricant d origine seulement 2 La porcelaine est garantie seulement contre les d fauts
12. might be stuck to the case very tightly during assembly soapy water is used which dries up in time lf required to remove motor from the case unscrew motor retai ning screws if any Also release the insulator cable to the lid Lift out motor assembly Do not attempt to dismantle the motor assembly itself as it is clipped together These clips may break off when trying to unclip them In addition to damaging the clips the motor seals may be damaged when the lid is removed from the motor housing The motor is filled with dielectric oil do not remove it or replace with regular oil Please note the distributor purposely does not keep seals bearings or oil in stock 5 3 SANITOP FUNCTION CHECKUP IMPELLER Invert motor to gain access to pump chamber at the base Unclip pump cover plate from motor housing Unscrew the pump impeller counter clockwise releasing it from the spindle block the spindle to unscrew Clean pump chamber and discharge elbow and pipe work to ensure no blockage exists Check that drive shaft rotates freely Also check that the air relief hole in the wall of the chamber is clear CUTTER BLADE The blades can be easily removed if they ever require replacement Simply remove the retaining circlip on top of the blade rotor assembly and lift rotor blade assembly off the spindle The blades can now be slid sideways removed and replaced Safety note The blades are sharp and should be handled with extreme
13. thermique interne n a pas t activ attendez environ 20 minutes pour que l appareil se remette en marche 3 Syst me hydraulique Assurez vous que le tuyau d vacuation et le tuyau d a ration ne sont pas bouch s Si l ensemble broyeur pompe tourne par intermittence sans que la chasse d eau ait t actionn e ni que de l eau ait t vacu e v rifiez si l eau du r servoir ne coule pas dans la cuvette si l eau ne retourne pas dans l appareil parce que le clapet antiretour a t mal pos ou si le coude d vacua tion n a pas t mal install Si l ensemble broyeur pompe est muni d un clapet antiretour externe assurez vous que le du clapet est propre et l g rement enduit de graisse de silicone 4 2 D POSE POUR PETITE INTERVENTION tant donn que l appareil est reli une source d alimentation en lectricit et en eau il est important de v rifier les points suivants avant de le r parer d placer 1 Fermez l arriv e d eau et fermez le robinet vanne facultatif sur le tuyau de sortie 2 D branchez lectriquement l appareil 3 Videz le plus possible l eau de la cuvette du cabinet et du reservoir de chasse 4 S parez le cabinet de l appareil Enlevez la cuvette du cabinet et mettez la de c t en l appuyant contre un mur pour l emp cher de basculer L utilisation d un aspirateur pour d chets humides peut tre utile pour enlever l eau r siduaire 6 Au
14. 1 2 x 3 4 into the 1 1 2 hub of the Y fitting 3 Screw male adapter MPT x Hub 3 4 x 3 4 sweat into the bushing when discharge piping is in copper buy brass adapter when in CPVC buy CPVC adapter a When in copper solder a length of pipe to the male adapter first allow to cool then screw assembly into female bushing into the branch socket When soldering pipe systems together wind a wet rag around the plastic to keep it cool Maintain at least a distance of 6 between the plastic and the piece soldered Use Teflon tape or 100 Teflon dope on male thread Any other dope product will deteriorate plastic material b When using CPVC material use glue to glue the CPVC pipe into the ABS fitting Caution Do not use ABS glue on CPVC materials as the plastic will not bond 2 8 CONNECTION TO ELECTRICAL SUPPLY All wiring should be in accordance with the applicable electrical code in your territory The macerating system requi res a single phase 120 volt 15 Amp supply When installed in a bathroom the receptacle should be 40 inches away in a straight line from a shower or bathtub Connect only to receptacle protected by a ground fault circuit interrupter GFCI Warning risk of electric shock this pump is suplied with a grounding conductor and grounding type attachment plug to reduce the risk of electrical shock Be certain that it is connected only to a properly grounded type receptacle 2 9 CONNECTION TO A VEN
15. T SYSTEM Sanitop See page 2 drawing 7c The macerating unit must be vented It has 2 inlets on the top of the cover a 1 1 2 cap and a hole of smaller diameter The unit must be connected to a vent system according to plumbing codes Insert the elbow connector provided on the 1 1 2 port and clamp it down Then connect to the vent pipe Note that all fixtures connected to the system must also be vented Warning Do not use an air admittance valve or a mechanical spring loaded venting device as these devices are one way valves The air pressure in and outside the macerating unit must be equal a cheater vent will obstruct the airflow one direction Note The smaller diameter 1 2 hole must be plugged with a plastic cap supplied i 2 10 ACTIVATING THE UNIT 1 Ensure that the toilet is free of building debris prior to activating Open the shut off valve and let the tank fill up Ensure power supply is on Flush several times with intervals in between depositing a few sheets of toilet paper into the bowl to check discharge piping Usually there should be no paper remaining in the bowl after each flush BWDP EJ USAGE The normal domain of application of SFA macerating units only concerns the disposal of human waste toilet paper and water SANITOP is designed for family use only and cannot accept without damage the disposal of sanitary items such as condoms tampons sanitary pads and cotton swabs CAU
16. TIONARY NOTES Do not discharge any acids alkaloids solvents painting paint strippers food waste plastic bags metal such as nails hairpins wood building materials kitty litter or anything that could halt or damage or corrode the unit Disregarding the above might damage the macerating unit and shall void your warranty Do not hang bleach blocks or hydrochloride cleaners in the toilet tank These solutions have been shown to deteriorate the plastic and neoprene components of the flush and fill valves and may cause leaks In the event of a power loss do not use the toilet or any other sanitary fixture connected to the macerating unit since it will not work until the power is restored The toilet works as a conventional flushing toilet and needs no maintenance in normal use However there is nothing wrong with cleaning out the macerating unit once a year Do not use bleach Be careful not to let water enter the electrical cord opening The macerating unit starts automatically once the toilet is flushed or if the sink is discharged and ceases operation once the contents have been pumped away Whenever the unit is not to be used for long periods of time vacation power failure maintenance etc turn off the water supply to the tank and flush the unit to evacuate the water No leakage into the bowl should ever be permitted from the tank In areas which are prone to freezing the total system must be properly winterized This inc
17. ansit La somme de 300 devrait suffire Lorsque des r parations sont effectu es en dehors de la p riode de garantie ou si l ensemble broyeur pompe a t endommag par l utilisateur une estimation des frais de r paration est envoy e se client Les reparations doivent obligatoirement tre pay es a avance EJ DEPANNAGE uniquement personnel qualifi 5 1 Voir paragraphe 4 INTERVENTION 4 1 et 4 2 5 2 Si vous devez ouvrir l ensemble broyeur pompe d gagez d abord le coude r duction en escalier puis d tachez le couvercle et soulevez le Dans certains cas il se peut que le cou vercle reste tr s solidement coll au r servoir Le savon employ pour l assemblage en usine peut avoir s ch S il faut retirer le moteur du boitier d vissez les vis retenant le moteur D gager le c ble isolant de la cuve Soulevez le bloc moteur N essayez pas de d monter le bloc moteur car ses composants sont li s entre eux par des pinces qui pourraient se briser si on tente de les d ta cher En plus d endommager les pinces les joints d tanch it du moteur pourraient tre endommag s lorsque le couvercle est retir du bo tier du moteur Le moteur est rempli d huile di lectrique il ne faut pas vidanger cette huile ni la remplacer par de l huile ordinaire Veuillez prendre note que le distributeur ne stocke pas de joints d tanch it de bagues ou d huile 5 3 CONTR LE DU SANITOP TURBINE Ret
18. au Ils ne sont pas destin s a recevoir les eaux de cuisine et ne permettent donc pas l vacua tion des eaux d un lave vaisselle ou d une laveuse Le syst me doit s vacuer dans un tuyau d vacuation d au moins 3 4 de pouce de diam tre Le syst me de broyage peut pomper jusqu a 12 pieas verticalement pour le Sea avec une descente constante par gravit d au moins 1 4 de pouce pour 1 po tout le long du parcours jusqu au point d vacuation S il faut installer un tuyau de mont e vertical celui ci doit pr c der tout tron on horizontal et doit tre pos le plus pr s possible du coude d vacuation Lorsque vous avez commenc l installation d un tron on horizontal vous ne pouvez changer de direction vers le haut de la verticale ENTREES SUPPLEMENTAIRES L ensemble broyeur pompe est quip de deux entr es supplementaires de 1 1 2 de pouce sur le dessus du boitier Ces orifices d entr es accueillent la connexion requise a un vent oir la section 2 9 ainsi que la connexion a un vier EVIER Tout type d vier peut tre connect l ensemble broyeur pompe Comme tout appareil de salle de bains un siphon en P doit tre install sous l vier ll faut laisser un minimum de de pouce par pied pour un coulement par gravit vers l entr e sup rieure de l ensemble pompe broyeur Remarque Si l entr e pour la connexion a l vier n est pas utilis e celle ci doit tre bloqu e a l aide d un bouchon fo
19. avec une collerette de 1 1 2 pouce 2 Lisez d abord le point 3a ci dessous si vous utilisez un tuyau en cuivre Collez un manchon bout male x filet femelle 1 1 2 pouce x 3 4 pouce dans le bout uni de 1 1 2 pouce du raccord en Y 3 Vissez l adapteur m le filet m le x bout uni tuyau de suintement 3 4 pouce x 3 4 pouce dans le manchon Si la tuyauterie d vacuation est en cuivre achetez un adapteur en laiton si elle est en CPVC achetez un adapteur en CPVC a Si la tuyauterie est en cuivre soudez d abord un troncon de tuyau a l adapteur male laissez refroidir puis vissez l ensemble dans le manchon femelle Lorsque vous souderez les tuyaux ensemble enroulez un chiffon humide autour du manchon en plastique pour qu il reste froid Conservez une distance d au moins 6 po entre le plastique et la piece soud e Utilisez du ruban de teflon sur le filet male Tout autre produit va abimer le plastique b Pour le CPVC collez le manchon dans le tuyau en ABS avec du ciment pour ABS et CPVC Attention Ne mettez pas de ciment ABS sur les tuyaux en CPVC parce que le plastique ne va pas coller 2 8 RACCORDEMENT LECTRIQUE Tous les branchements lectriques doivent tre conformes au code de l lectricit en vigueur dans votre r gion Le syst me de broyage requiert une alimentation monophas e de 120 V 15 A Si la prise de courant est situ e dans une salle de bains elle doit tre a une distance de 40 pouces en ligne directe
20. bject to the following conditions e The customer must have an authorized return number from the manufacturer in order to validate exchange e The customer must produce proof of purchase to validate exchange LIMITATIONS 1 Fill and flush mechanism are guaranteed as per OEM warranty only 2 Vitreous china are guaranteed only for a factory defect 3 Cost of disconnection and reconnection ie labor charges are not covered by the warranty and are end users responsability 4 Cost of mail or freight when a part or parts of the system have to be repaired at the company are not covered by this warranty 5 In no event shall the company be reliable for any special incidental or consequential damage loss or injury of whatsoever nature or kind arising from or in connection with the product or any component thereof 6 The guarantee is transferable only when the product remains at the same premises as where it was installed initialy Except as set forth in this Limited Warranty the company disclaims all other warranties express or implied with respect to the product or any component thereof including but not limited to all implied warranties for merchantability and fitness for a particular purpose For Service and other inquiries please call either of the addresses listed below United States Canada SFA SANIFLO INC SFA SANIFLO INC 105 Newfield Avenue Suite A 1 685 Speedvale Avenue West Edison NJ 08837 Guelph ON N1K 1E6 Cu
21. ble when requesting warranty work Name Owner Installation Address Purchased From Installed By Date of Purchase Serial Number Date of Manufacture see manufacturers tag on unit LIMITED WARRANTY 2 Year Warranty from Date of Purchase Subject to the terms and conditions set out below SFA SANIFLO INC hereafter designated the as the Company warrants that it will repair or replace the product or any of its component parts at the Company s discretion if it deems that the product or part it is defective or does not meet the rated performance due to a maufacturing or material default If replacement is to be issued this will only be extended to the first 180 days starting from the date of purchase Warranty repairs will apply after such date up to the warranty s date of conclusion TERMS AND CONDITIONS The conditions of this warranty are the following e The product must be installed in accordance with the use described in the enclosed manuals e The product must be connected to a single phase 120V 60Hz electrical outlet and was not subject to any negligence accident or exposure to harmful products or substances e The alleged defect or fault must be reported either to the installer or to the Company during the warranty coverage period e The warranty coverage period is valid for 2 years PART OR PRODUCT EXCHANGE The product may be exchange without cost only at the sales outlet where it was purchased su
22. ded wire 4 3 RETURN AND REPAIR OF THE MACERATING UNIT In the event that the unit needs to be returned for service please call for possible options or to inquire about an authorized repair shop in your area When you are required to return the macerating unit to the manufacturer please ensure that prior to shipping the unit has been cleaned and disinfected inside and outside A labour charge will be in effect for cleaning 50 00 Before returning any unit a return authorization is needed from the manufacturer Units returned without prior RGA number will be refused and returned collect If you return the macerating unit in its original packaging please remove the discharge elbow and retain until re assembly If elbow is not removed damage due to shipping might occur Please package the macerating unit properly with adequate shock absorbent material around it Send this package prepaid to the manufacturer making sure to insure against loss and or transit damage the amount of 300 00 will suffice If any repairs are done outside the warranty period or when the user has damaged the macerating unit you will be apprised of repair costs All repair work will be conducted on a pre paid basis only EJ MAINTENANCE for qualified personnel only 5 1 See paragraph 4 PROBLEM SOLVING 4 1 and 4 2 5 2 If you need to open the macerating unit first release the discharge elbow unclip the lid and pull up lid In some cases the lid
23. e couvercle vers le bas puis tout autour en frappant le couvercle avec un maillet en caoutchouc ou un bloc de bois et un marteau Le couvercle doit bien reposer sur les attaches KJ CONSEILS ANCRAGE DES TUYAUX Tous les tuyaux des installations sanitai res doivent tre ancr s conform ment aux recommandations du fabricant pour les emp cher de pendre car ils pour raient alors tre bloqu s par une accu mulation de mati res solides COURBES Dans la mesure du possible utilisez des courbes de tuyau plut t que des coudes Si des coudes de 90 ne sont pas dispo nibles utilisez deux coudes de 45 pour former une courbe de 90 LA TUYAUTERIE VERTICALE D ABORD Lorsqu on installe des tuyaux a la verti cale il faut les poser avant de poser les tuyaux horizontaux DIRECTEMENT A LA VERTICALE Les tuyaux de mont e doivent tre fixes le plus pres possible du cabinet en laissant assez d espace pour contourner le reservoir Les tuyaux horizontaux sortant du cabinet et plac s avant un tuyau vertical ne doivent pas avoir plus de 12 a 18 po de longueur ACCES FACILE ll faut avoir acces l ensemble broyeur pompe et pouvoir le d poser en cas de reparation Au moment de l installation il faut poser une purge et une vanne d ar r t a passage integral la base de tout tuyau d vacuation vertical pour permet tre de r parer facilement l appareil PAS DE DESCENTE DIRECTE Si le point de d ve
24. e to freezing is adequately insulated or heated In unheated buildings the toilet piping and macerating unit must be properly winterized with RV or plumbers anti freeze or drained completely ELECTRICITY Before attempting any maintenance or servicing the unit must be disconnec ted from the power source The mace rating system must be connected to a Ground Fault Circuit Interrupter GFCI FA TROUBLE SHOOTING GUIDE PROBLEM Motor turns normally but the water evacuates slowly from the bowl flush incomplete Waste build up in bowl The macerating unit does not start up Water does not evacuate The motor hums but does not turn the water does not evacuate Water goes down slowly and motor works intermittently The water evacuates from the toilet but the motor runs for a very long time thermal overload activates After evacuation the motor engages several times in succession before it stops completely Motor turns noisily without stopping or pumping After evacuation the motor starts stops and re engages indefinitely For Sanitop the motor turns with a rattling noise Water backs up into shower tray or bathtub CAUSE Discharge pipe blocked or valve not vented properly Inadequate water supply from reservoir Power supply off Thermal overload cut out Foreign body blocking the macera ting blades Defective capacitor Clogged up sanitary napkin news paper plugg
25. ed breather hole etc Kinked blocked discharge pipe damaged membrane defective impeller and partially blocked pump Water siphons back into the macerating unit Check valve is not functioning properly Siphonage or insufficient back pressure in discharge pipe causing airlock Foreign object Water leaking from reservoir into bowl Faulty non return check valve Solid item has fallen into the grille of the macerating unit Inadequate gravity fall into macera ting unit or oe in drain piping Faulty inlet control flap IMPORTANT REMEDY Clean out the piping and air breather hole Check and or adjust water level in reservoir Wait for thermal overload to engage approx 20 min See dismantling Flush 3 or 4 times to clear Cleaning or dismantling may be required Clean out the breather hole Check installation Flush once or twice with clean water to clear valve or remove valve to clean Modify discharge pipe run to eliminate siphonage and or increase backpressure E g reduce pipe size ut extra bend in run Remove oreign object Check flush valve Check and clean non return check valve Clear object from grille area 1 4 per foot gravity fall minimum into macerating unit from other sani tary fixtures Clean out the flap When claiming a warranty repair we will need the information you have written down below Please ensure that you have all particulars availa
26. installation Tirez la chasse d eau une ou deux fois avec de l eau claire pour d gager le clapet ou enlevez le clapet et nettoyez le Modifiez la tuyauterie d vacuation de mani re a liminer le siphonage ou a augmenter la contrepression p ex utilisez des tuyaux plus petits ajoutez une courbe de tuyau Retirez le corps tranger V rifiez la soupape de chasse d eau V rifiez le clapet antiretour et nettoyez le D gagez l objet coinc dans la cr pine Assurez vous qu il y a un coulement par gravit d au moins 1 4 po a 12 po entre les autres appareils sanitaires et l ensemble broyeur pompe Nettoyez les clapets d entr e Lorsque vous ferez une demande de r paration au titre de la garantie nous aurons besoin des renseignements que vous aurez inscrits ci dessous Veuillez vous assurer d avoir tous les d tails port e de la main lorsque vous pr senterez votre demande de r paration au titre de la garantie Nom du propri taire Adresse de l installation Lieu d achat Install par Date d achat Num ro de s rie Date de Fabrication voir l tiquette sur le cot de l appareil GARANTIE LIMITEE Garantie de deux ans a partir de la date d achat Sous reserve des modalit s et conditions enoncees ci dessous SFA SANIFLO INC ci apr s designee comme la Compagnie garantit qu elle r parera ou remplacera a son gr le produit ou l une quelconque de ses pi ces qui
27. lacez les joints d tanch it en mousse sous le trou d vacuation du r servoir entre le r servoir et la cuvette Placez le r servoir au dessus de la cuvette Ins rez les vis et le joint d tanch it dans le r servoir et serrez les crous en dessous Ne serrez pas trop car cela pourrait endommager la c ramique Le syst me est livr avec des pattes de fixation pour l emp cher de se d placer pendant l utilisation Pour optimiser les derniers d veloppements techniques concernant l insonorisation incorpor dans cette unit il est important de e positionner la cuvette de telle sorte qu elle ne soit pas en contact avec une cloison ou un mur de la pi ce e placer la cuvette de toilette sur une surface parfaitement plane pour s assurer que les supports elastiques sont plei nement efficaces e fixer le tuyau d vacuation correctement avec des distances n exc dant pas 3 pieds 1m entre les l ments de fixation 2 5 RACCORDEMENT A L ALIMENTATION EN EAU Raccordez le tuyau d alimentation en eau a la soupape de remplissage 2 6 RACCORDEMENT A LA TUYAUTERIE D EVACUATION Ces ensembles broyeur pompe comportent un coude et un manchon a r duction en escalier coupez simplement la partie appropri e du manchon afin de l adapter au diam tre de votre tuyauterie Utilisez un tuyau rigide et non un tuyau flexible pour viter qu il se d forme a la longue Utilisez un tuyau d vacuation de 3 4 ou 1 pouce Vous pou
28. le r servoir se remplisse V rifiez que l appareil est bien branch Tirez plusieurs fois la chasse d eau en attendant un peu chaque fois et en jetant quelques feuilles de papier hygi nique dans la cuvette pour v rifier la tuyauterie d vacuation Normalement il ne doit pas rester de papier dans la cuvette apr s une chasse d eau NO KO Eq UTILISATION Les ensembles broyeur pompe du Groupe SFA s utilisent normalement uniquement pour vacuer les d chets humains le papier hygi nique et l eau SANITOP est con u uniquement pour une utilisation m nag re et ne peut vacuer des d chets sanitaires tels que des condoms des tampons des serviettes sanitaires et des cotons tiges sans risquer des dommages MISES EN GARDE Il est strictement interdit de jeter dans le cabinet des acides des alcaloides des solvants de la peinture des d capants peinture des d chets alimentaires des sacs de plastique du m tal tel que des clous des pingles cheveux du bois des tissus du pl tre des gravats de la liti re pour chats ou toute autre mati re qui pourrait bloquer endommager ou corroder l appareil Si cette mise en garde n est pas respect e l ensemble broyeur pompe pourrait tre endommag et la garantie pourrait tre annul e Ne mettez pas de javellissants sous forme de bloc ni de produits nettoyants au chlorhydrate dans le r servoir Il a t prouv que ces solutions attaquent les
29. ludes the draining of all pipes the toilet tank and bowl and the macerating tank The macerating system is simple to winterize Pour a jug of plum bers anti freeze into the tank and flush the toilet This will cause the macerating unit to activate and all remaining water will be replaced by plumber s anti freeze No parts or labour are warranted when a breakdown occurs due to freezing Ensure that there are no faucets left open Drops will eventually fill up the pump and the resultant repeated start stop of the motor may heat up to such an extent that the thermal overload switch may eventually operate and automatically stop the motor thus possibly causing a flood This device is not designed for persons including children with limited physical sensory or mental abilities or those with minimal experience and knowledge unless they are monitored and are given the necessary instructions for using the device with the help of a person responsible for their safety Monitor children and make sure they do not play with the device EJ PROBLEM SOLVING 4 1 CHECKUP The macerating unit is very reliable With normal use long service is assured However in certain cases an incident may occur which you may rectify yourself Before taking any action check the following points 1 Plumbing system Flush system water supply turned on 2 Electrical system G F C I breaker on Receptacle on Fuse okay Breaker on Male plug still in recep
30. ly cut off the appropriate portion of the bushing in order to fit it to the discharge pipe Use ridged wall pipe not flexible pipe or hose as flexible pipe may distort over time Use 3 4 or 1 discharge pipe Install a full port ball or gate valve and a union in the discharge pipe in order to facilitate the removal of the macerating unit Place the union or hose connector then the valve at the lower portion of the discharge pipe If you wish the unit to pump vertically and horizontally you may calculate that 3 feet of vertical lift is equivalent to 30 feet of horizontal run Each bend or change of direction causes minor losses which must be deducted from the discharge performance figures in accordance with the usual head loss practice Rough guide reduce discharge height by 3 feet for each 90 turn The discharge pipe work can be made from 3 4 diameter material Copper Type M CPVC or PVC Use long turn bends and not elbows elbows are not normally available in plastic piping use two 45 pieces back to back to make a 90 elbow The connection to the soil stack or sewer pipe should be made with an approved wye fitting When in doubt about this procedure please have a plumbing contractor install this for you 2 7 SEWER PIPE COPPER CAST IRON PVC ABS 1 Install an appropriate wye fitting into the sewer pipe with 1 1 2 branch hub 2 Read point 3a first if using a copper wye Glue a bushing spigot x FPT 1
31. moment d enlever l ensemble broyeur pompe s parez avec soin les tuyaux d admission ils peuvent contenir de l eau r siduaire 7 Sur Sanitop par le trou manchette l aide d un fil de fer courbe enlever le corps tranger 4 3 RETOUR ET REPARATION DE L ENSEMBLE BROYEUR POMPE Si le syst me de broyage doit tre r par appelez nous pour conna tre les autres options possibles ou pour vous renseigner sur un atelier de r paration agr dans votre r gion Lorsque vous devez retourner l ensemble broyeur pompe au fabricant veuillez vous assurer qu il a ete soigneusement nettoy et d sinfect l int rieur comme a l ext rieur avant de l exp dier Des frais de manutention seront factur s pour le nettoyage 50 Une autorisation pr alable du fabricant est n cessaire avant le renvoi d un appareil Les appareils retourn s sans num ro d autorisation de retour de marchandise seront renvoy s leur exp diteur leurs frais Ol Si vous renvoyez le broyeur dans son emballage d origine retirez le coude d vacuation et mettez le de c t afin de le remonter apr s retour de l unit Si vous vous abstenez de retirer ce coude il risque d tre endommag pendant le transport ainsi que l unit On devra prendre soin d envelopper l appareil dans un mat riau destin amortir les chocs Exp diez le colis au fabricant port pay et veillez le faire assurer contre les pertes et les dommages en tr
32. olliers e Si l entr e pour le lavabo n est pas utilis e boucher l entr e non utilis e avec les bouchons fournis apr s avoir graiss les joints 2 3 ASSEMBLAGE DU CABINET Le r servoir du cabinet est d j assembl Veuillez cependant vous assurer que les vis crous boulons et autres sont bien serr s 2 4 ASSEMBLAGE DES ELEMENTS DU SYST ME Sanitop voir page 2 dessin 7a 1 Placez l ensemble broyeur pompe a l endroit d sir et raccordez le a la tuyauterie Voir Raccordement a la tuyauterie d vacuation 2 Placez la sortie horizontale de la cuvette contre le joint accord on blanc et marquez l emplacement des trous de fixation de la cuvette sur le plancher 3 Enlevez la cuvette et percez deux trous d environ 2 1 4 pouces de profondeur au moyen d une m che de 5 16 de pouce Ins rez des chevilles de plastique dans les trous Si le plancher est en bois percez un trou de guidage a l aide d une m che de 1 4 de pouce 4 Placez la cuvette devant l ensemble broyeur pompe et positionnez le joint accord on le plus loin possible par dessus la sortie horizontale de la cuvette puis fixez a l aide d un collier Assurez vous que le collier est fix de mani re homog ne autour du joint accord on 5 Placez la cuvette au niveau des trous que vous avez perc s dans le plancher Placez les protecteurs de c ramique sur les vis Serrez les vis ne serrez pas trop et posez les capuchons de plastique dessus 6 P
33. ournez le moteur pour avoir acc s au corps de pompe a la base D tachez la base du boitier du moteur D vissez la roue motrice de la pompe dans le sens contraire des aiguilles d une montre pour la d gager du mandrin bloquer le mandrin pour d visser Nettoyez le corps de la pompe le coude d vacuation et la tuyauterie pour vous assurer qu il n y a aucune obstruction Assurez vous que l arbre du moteur tourne librement Assurez vous galement que le trou d vent dans la paroi du corps de pompe n est pas obstru LAMES DE BROYAGE Les lames peuvent tre retir es facilement s il devient n cessaire de les remplacer Retirez simplement la pince de retenue sur le dessus de l assemblage lames rotor et retirez le moyeu en le soulevant Les lames peuvent alors tre gliss es lat ralement enlevees et remplac es Mise en garde Les lames sont extr mement tranchantes 5 5 MISE EN GARDE Il ne faut pas immerger compl tement le syst me de broyage dans l eau et il ne faut pas laisser d eau entrer par louverture du cable lectrique 5 6 REMONTAGE DE COUVERCLE Lorsque vous replacerez le couvercle sur l appareil il est conseill de lubrifier l g rement le joint d tanch it en caoutchouc avec de l eau savonneuse ou du savon a vaisselle N utilisez pas de Vaseline car cela pourrait dilater les mat riaux en n opr ne Le joint d tanch it doit d abord tre a l int rieur du couvercle Commencez par pousser l
34. r 732 225 6072 T l copieur 519 824 1143 Courriel sfasales saniflo com Courriel sales saniflo com Site Web www saniflo com Site Web www saniflo ca
35. re constamment Pour le Sanitop le moteur tourne mais fait un bruit de ferraille L eau remonte dans la baignoire ou la cabine de douche CAUSE Le tuyau d vacuation ou le clapet sont bouch s Quantit insuffisante d eau provenant du r servoir Le courant est coup Le rupteur thermique ne fonctionne pas Un corps tranger bloque les lames de broyage Condensateur d fectueux C est bouch serviette hygi nique paper journal prise d air colmatee etc Tuyau d vacuation bouche ou tordu membrane endommag e roue motrice d fectueuse pompe partiellement bloqu e L eau est renvoy e dans l ensemble broyeur pompe Le clapet entiretour ne fonctionne pas bien Siphonage ou manque de contrepression dans le tuyau d vacuation causant une poche d air Pr sence d un corps tranger L eau du r servoir fuit dans la cuvette Clapet antiretour d fectueux Un corps solide est tomb dans la cr pine de l ensemble broyeur pompe L coulement par gravit dans l ensemble broyeur pompe n est pas ad quat Clapet d entr e d fectueux IMPORTANT SOLUTION Nettoyez le tuyau et le clapet V rifiez ou augmentez le niveau d eau dans le r servoir Attendez que le rupteur thermique fonctionne environ 20 minutes Voir D montage Tirez la chasse trois ou quatre fois pour d gager Il faudra peut tre nettoyer ou d monter Nettoyez la prise d air V rifiez l
36. rsement dans la colonne de renvoi est beaucoup plus bas que la base de l ensemble broyeur pompe il pourrait tre n cessaire de poser un clapet de contre siphonnement au point le plus lev de la tuyauterie pour emp cher le siphonnage du joint d tanch it MINIMUM DE TROIS PIEDS L ensemble broyeur pompe doit tre install a au moins trois pieds de la colonne de renvoi De cette facon le broyeur pourra fonctionner durant une p riode de temps suffisante pour r duire efficacement le volume des d chets RACCORDEMENT A LA COLONNE DE RENVOI Tout raccordement des tuyaux de vidan ge la colonne de renvoi doit tre fait avec un raccord appropri et homologu Utilisez de pr f rence les raccords en Y illustr s PAS DE TUYAUX EN DIAGONALE Tous les tuyaux de vidange sortant de l appareil doivent soit monter directement la verticale soit tre en position horizontale avec un l ger coulement par gravit jusqu au point d vacuation Il ne faut pas installer de tuyaux en diagonale entre l appareil et le point d vacuation TUYAUTERIE Tous les tuyaux doivent tre en cuivre ou en plastique soud au solvant Il ne faut pas utiliser de tuyaux flexibles Les pendards doivent tre espacesd au moins quatre pieds pour emp cher les tuyaux de cogner VIDANGE Ne jamais vacuer les eaux us es direc tement dans un gout ciel ouvert un trou d homme ou un drain pour les eaux de pluie
37. s Macerating system must discharge into a minimum 3 4 inch sanitary drainage pipe The macerating system will pump up to 12 feet vertically with a 1 4 per foot gravity fall minimum constantly throughout the horizontal run to the point of dis charge If you require a vertical lift it should precede any hori zontal run and should commence as near as possible to the discharge elbow Once you have started the horizontal run you cannot change directions in a upward vertical manner ADDITIONAL INLETS The macerating unit is equipped with two additional 1 1 2 inlets at the top of the case These inlets are to accommodate a required vent connection Refer to section 2 9 and a connection to a sink SINK Any type of sink can be connected to this macerating system As any bathroom fixture a p trap needs to be installed under the sink There should be a minimum 1 4 per foot gravity fall towards the top inlet of the case Note In case the sink connection inlet is not used you will need to block off this inlet with the plug provided Only this inlet can be blocked as the vent connection should always be vented 1 2 NORMAL OPERATING CYCLE As the flush is operated or as the lavatory discharged the water and waste enter the unit and the water level begins to rise triggering the micro switch in the pressure chamber This in turn activates the motor The shredded waste is picked up by the impeller and discharged through a 3 4 or 1
38. sse d eau du cabinet Cela activera le syst me et toute l eau qui reste sera remplac e par de l antigel Ni la main d ceuvre ni les pieces ne sont couvertes par la garantie si l appareil tombe en panne a cause du gel Assurez vous qu il n y a pas de robinet mal ferm sinon le moteur qui se met en route et s arr te tr s souvent peut disjoncter Il pourrait en r sulter une inondation Cet appareil n est pas destin aux personnes y compris les enfants dont les capacit s physiques sensorielles ou mentales sont limit es ou auxquelles l exp rience et les connaissances font d faut except si elles sont sous surveillance et re oivent les instructions n cessaires pour utiliser appareil avec l aide d une personne responsable de leur s curit Surveiller les enfants et veiller a ce qu ils ne jouent pas avec l appareil EJ INTERVENTION 4 1 V RIFICATION L ensemble broyeur pompe est tr s fiable Dans des conditions d utilisation normales il fonctionnera longtemps Cependant en cas de probl me que vous pouvez r soudre vous m me v rifiez les points suivants avant de faire quoi que ce soit 1 Plomberie arriv e d eau ouverte chasse d eau fonctionne bien 2 Syst me lectrique La prise de courant ou le coupe circuit en cas de mise la terre du neutre fonctionnent le fusible est en bon tat le disjoncteur est en circuit et la fiche m le est dans la prise de courant Assurez vous que le rupteur
39. stomer toll free 800 571 8191 Customer toll free 800 363 5874 English Customer toll free 800 877 8538 French Telephone 132 225 6070 Telephone 519 824 1134 Telefax 732 225 6072 Telefax 519 824 1143 Email sfasalesQsaniflo com Email salesQsaniflo com Web Site www saniflo com Web Site www saniflo ca LE INTRODUCTION Ce broyeur est fabriqu dans une usine certifi e ISO 9001 2000 accr dit e par l AFAQ Cet quipement b n ficie de la derni re innovation technologique li e a l insonorisation Pour profiter pleinement des avantages fournis par cette nouvelle g n ration d appareils il est tr s important de se conformer aux instructions d installation 1 1 DESCRIPTION GENERALE L ensemble broyeur pompe est un syst me de pompage r sidentiel pour un cabinet d aisances et un vier Le syst me comprend trois composants principaux L ensemble broyeur pompe qui se raccorde un cabinet sortie horizontale arri re la cuvette le reservoir L ensemble broyeur pompe comprend lui m me trois parties le boitier qui renferme le m canisme une chambre de pression activ e et d sactiv e automatiquement un moteur a induction qui met en marche les lames de broyage et la turbine L ensemble broyeur pompe peut recevoir simultan ment les eaux en provenance d un lavabo et d un WC une seule toilette par appareil Nos syst mes de broyage sont con us pour vacuer les d chets humains le papier hygi nique et l e
40. tacle Check that the thermal overload has not operated wait approximately 20 minutes for unit to reactivate 3 Hydraulic System Check that the discharge and vent pipe are not blocked If the macerating unit turns on intermittently without the flush having been activated or water having been discharged check that water out of the toilet tank is not leaking into the bowl Or that there is no leakage back into the macerating unit due to incorrect seating of the check valve and or that the discharge elbow is seated properly 4 2 DISASSEMBLY FOR LITTLE INTERVENTION As the unit is connected to the water and electrical supply it is important to check that the following actions have been taken before removing the unit 1 If possible close off the water supply to the tank and close the ball or gate valve on the outlet pipe 2 Pull the electrical cord out of the receptacle before removing unit 3 Empty out as much water as possible from the toilet tank and the toilet bowl 4 Disconnect toilet from unit Remove toilet bowl and set aside against a wall to prevent from tipping over 5 The use of a dry wet type vacuum cleaner might assist you greatly in removing the residual water in the bowl or macerating unit 6 When you have to remove the macerating unit carefully disconnect the inlet drainpipes there might be residual water inside 7 For Sanitop use the WC inlet to remove a foreign object with the help of a fol
41. tical discharge pipe work from the unit to allow easy L 1 service of the unit NO DIRECT FALL Where the point of discharge into the soil stack is significantly lower than the base of the unit a vacuum relief valve may need to be fitted at the highest point in the pipe run in order to avoid siphonage of the water seal THREE FEET MINIMUM The macerating unit must be installed at least 3 feet from the soil stack This will allow the macerator to operate for an adequate period of time to ensure efficient waste reduction SOIL STACK CONNECTION All discharge pipe work must be connected to the soil stack by an appropriate and approved connection A tee or y fitting as shown is preferable NO DIAGONAL UPHILL PIPE RUNS All ae pipe work from the unit should run either directly vertical upwards from it or in a horizontal plane with a small gravity flow to the point of discharge Pipe work should not be installed with de upward slope from the unit to the point of discharge PIPE WORK All pipe work should be either copper PVC or CPVC Do not use flexible pipes Hangers should not be less than three feet apart to prevent pipe rattling DISCHARGE Never discharge directly into an open drain fixture manhole or rainwater Si It is illegal for it constitutes a health hazard Direct connections into sanitary waste systems only shall be acceptable FREEZING Ensure all pipe work susceptibl
42. urni Seule cette entr e peut tre bloqu e contrairement a la connexion d vent qui doit toujours tre ventil e 1 2 CYCLE NORMAL DE FONCTIONNEMENT Lorsque la chasse d eau est actionn e ou que l eau ou du lavabo est vacu e l eau sale et les d chets entrent dans le syst me Le niveau de l eau monte dans le bo tier ce qui enclenche le micro interrupteur de la chambre de pression Cela met en marche le moteur Les d chets ainsi broy s sont entra n s par la turbine travers un tuyau d vacuation jusqu la colonne de renvoi et l gout vanne dans une canalisation de 3 4 ou 1 pouce de diam tre Mise en garde Par souci de s curit l ensemble broyeur pompe ne doit jamais tre activ lorsque le couvercle est enlev EJ INSTALLATION 2 1 PREPARATION DE L ENSEMBLE BROYEUR POMPE Le coude de refoulement plastique clapet anti retour doit tre ins r partie longue dans le tuyau en caoutchouc situ sur le dessus du couvercle L adaptateur de caoutchouc doit ensuite tre ins r sur le c t de d charge du coude et s curis avec les pinces de m tal qui sont fournies L adaptateur de caout chouc peut tre coup selon le diam tre du tuyau d vacuation Trois brides de tuyau doivent tre utilis es pour s curiser tous les accessoires 2 2 RACCORDEMENTS SUPPL MENTAIRES e Pour connecter un lavabo utiliser le coude fourni Fixer le coude l entr e haute de la cuve avec les c
43. vez installer une vanne d arr t passage int gral et une purge sur la partie inf rieure du tuyau d vacuation afin de faciliter l enl vement de l ensemble broyeur pompe Placez la purge ou le connecteur boyau puis la valve sur la partie inf rieure du tuyau d vacuation Si vous voulez que l appareil pompe verticalement et horizontalement vous devez calculer que trois pieds de mont e verticale quivalent trente pieds de trajet horizontal Chaque courbe ou changement de direction provoque une perte de charge dont il faut tenir compte en calculant la capacit d vacuation selon les m thodes habituelles de calcul de la perte de charge Pour chaque courbe de tuyau 90 soustrayez environ trois pieds de la hauteur de relevage La tuyauterie de vidange peut tre en cuivre type M en CPVC ou en PVC de 3 4 de pouce L extr mit ouverte du tuyau en PVC peut recevoir un de ces trois mat riaux et le collier de fixation permet de fixer l ensemble Utilisez des courbes de tuyau plut t que des coudes Les coudes ne sont habituellement pas offerts en plastique Utilisez deux coudes de 45 pour former un coude de 90 Le raccordement la colonne de renvoi ou au tuyau d gout doit tre fait avec un raccord en Y approuv a cette fin En cas de doute faites faire l installation par un plombier 2 7 TUYAU D EGOUT CUIVRE FONTE PVC ABS 1 Placez un raccord en Y appropri dans le tuyau d gout