Home

Basement Watchdog BWC1 Instructions / Assembly

image

Contents

1. Basement Watchdog Dual Float Switch amp Controller Instruction Manual amp Safety Warnings a ia a Pee z SAVE THESE INSTRUCTIONS This manual contains important SAFETY WARNINGS and OPERATING INSTRUCTIONS for the Basement Watchdog Dual Float Controller You will need to refer to it before attempting any installation or maintenance ALWAYS keep these instructions with the unit so that they will be easily accessible Failure to read and follow these warnings and instructions could result in property damage serious injury or death Risk of electric shock To reduce this risk observe A WARNING the following precautions ALWAYS disconnect the pump and dual float controller from the power source before servicing or making adjustments NEVER handle the controller float switch pump or motor with wet hands or when standing on a wet or damp surface while the pump or controller is plugged into the power source MAKE SURE THERE IS A PROPERLY GROUNDED RECEPTACLE AVAILABLE This controller is wired with a 3 prong grounded plug To reduce the risk of electric shock be certain that it is only connected to a properly grounded 3 prong receptacle If you have a 2 prong receptacle have a licensed electrician replace it with a 3 prong receptacle according to local codes and ordinances NEVER bypass grounding wires or remove the ground prong from the controller DO NOT use an extension cord The electrical outlet sho
2. arranty service and will not be eligible for warranty service The product must be returned to GLENTRONICS INC for inspection in order to be considered for warranty service If the product is not returned to GLENTRONICS INC or the product is inspected by any person plumber contractor or business other than GLENTRONICS INC this warranty shall no longer be valid Prior to defective operation the unit must not have been previously altered repaired or serviced by anyone other than GLENTRONICS INC or its agent the serial number on the unit must not have been altered or removed the unit must not have been subject to accident misuse abuse or operated contrary to the instructions contained in the accompanying manual The dealer s dated bill of sale or installer s invoice must be retained as evidence of the date of purchase and to establish warranty eligibility Where are Products Sent for Warranty Service Glentronics Inc 645 Heathrow Drive Lincolnshire IL 60069 How Can I Obtain More Information By calling 800 991 0466 1806036 06 15
3. e County Waukegan Illinois or in the Northern District of Illinois if filed in Federal Court The maximum liability for any product described in this warranty shall be the cost of product replacement only If any term is held to be illegal or unenforceable the legality or enforceability of the remaining terms shall not be affected or impaired What is Covered by this Warranty GLENTRONICS INC warrants to the end purchaser that its pumps switch and control unit products are free from defective materials and workmanship for the periods indicated below All parts and labor excluding installation for a period of e 2 years from the date of purchase when purchased individually for use with another brand of sump pump e 3 years from the date of purchase when purchased with Basement Watchdog sump pumps The defective product must be returned directly to the factory postage prepaid with the original bill of sale or receipt to the address listed below GLENTRONICS INC at its option will either repair or replace the product and return it postage prepaid What is NOT Covered by this Warranty This warranty does not cover the cost or value of damaged property including expressly any property that has been affected by water overflow seepage or flooding If GLENTRONICS INC determines that a product is deemed defective under this warranty agreement it will repair or replace the PRODUCT ONLY GLENTRONICS INC will not cover the cost to reinstall t
4. ended e After the initial installation be sure to check the operation by filling the sump with water and observing the pump operation through one full cycle yi 2 BASEMENT CHD i n i EEE 0G FLOOR JOIST CONTROL UNIT PLUGGED INTO AC OUTLET DISCHARGE PIPE GATE VALVE RECEPTACLE ace Ty L UNION CHECK VALVE FLOAT WIRE PUMP DOUBLE FLOAT BASEMENT WATCHDOG AIR BLEED PUMP HOLE BRICKS Installation Instructions Prior to Installation 1 Visually inspect the product Products may be damaged during shipping If the product has been damaged contact your place of purchase or Glentronics Inc before installation 2 Thoroughly read the instructions provided to learn specific details regarding installation and use This manual should be retained for future reference a TT Ls _ r Dual Float Switch The dual float switch contains two large floating rings enclosed within a protective cage Water will lift the bottom float by a 1 4 which will activate the pump If for any reason the lower float does not activate the pump the water will rise and activate the second switch As the pump evacuates the water from the pit the floats will drop The pump will run for an additional 10 seconds to extend the cycle after the float returns to its Original position Note When mounting the float switch position the bottom of t
5. he cage at the height you want the pump to activate Installing the Dual Float Switch OD The Basement Watchdog dual float switch is easy to install by using the enclosed metal hose clamp 1 Hold the float switch to the discharge pipe so the cage is below the bracket Secure the float to the pipe with the enclosed hose clamp but do not completely tighten the clamp at this time Position the float switch to a level where the bottom of the float cage is no lower than 3 above the bottom of the pump and no higher than 1 below the top of the pit To avoid debris pouring into the float it should be positioned on the side of the discharge pipe opposite the drain tile Note It is important to mount the float below the drain tile that empties into the pit Mounting it above the drain tile would allow water to fill the drain tile before the pump is activated to pump out the water Once the float switch is in the desired position tighten the clamp Dual Float Controller Model BWC1 Completing the Installation Model No BWC1 THE 5 This control box is a piggyback switch a BASEMENT A 1 After the initial installation be sure to check the pump operation by that powers the Basement Watchdog WATCHDOG filling the sump with water and observing the pump through one full Dual Float The Dual Float Controller cycle When using the dual float the pump should run for an additional 10 will activate the pump when ei
6. he product nor will GLENTRONICS INC pay the cost of having a plumber or contractor repair or replace the product GLENTRONICS INC will not repair or replace a product that was installed incorrectly A product shall be considered installed incorrectly when it deviates in any way from the instructions described in this manual This warranty does not cover product problems resulting from handling liquids hotter than 104 degrees Fahrenheit handling inflammable liquids solvents strong chemicals or severe abrasive solutions user abuse misuse neglect improper maintenance commercial or industrial use improper connection or installation damages caused by lightning strikes excessive surges in AC line voltage water damage to the controller other acts of nature or failure to operate in accordance with the enclosed written instructions How to Obtain Warranty Service Within thirty 30 days of the product s defective performance the unit must be shipped freight prepaid or delivered to GLENTRONICS INC to provide the services described hereunder in either its original carton and inserts or a similar package affording an equal degree of protection Products not received by GLENTRONICS INC at the address indicated below within thirty 30 days of the product s defective performance will not be considered for warranty service Products received after the above mentioned timeframe from the date of purchase fall outside of the timeframe for w
7. ther perii e anana 222 0808 seconds after the float drops float is lifted and then shuts off automatically 10 seconds after the float drops a2 Amps maximum 2 Replace the pit cover making sure not to pinch or crimp the pump wire with the cover The pit cover either has a hole punch that will allow the cord to be passed through it or a hole can be drilled in the cover Installing the Dual Float Controller grounded 3 prong receptacle then Basement Watchdog AC sump pumps and battery backup sump pump products insert the pump plug into the Plug the control box into a properly x A Visit our website www basementwatchdog com for more information about the receptacle on the control box i For a neater installation secure the power cord and the float switch cord to the discharge pipe with wire ties or hose clamps Keep the cords separated Glentronics Inc Lincolnshire IL 60069 800 991 0466 from each other on opposite sides of the pipe www basementwatchdog com Limited Warranty By opening this package and using this GLENTRONICS INC product you are agreeing to be bound by the terms of the GLENTRONICS INC limited warranty warranty as set out below Do not use your product until you have read the terms of the warranty If you do not agree to the terms of the warranty do not use the product and return it within the return period stated on your purchase receipt from the retail store or authorized distributor where yo
8. u purchased it for a refund To the extent permitted by law this warranty and the remedies set forth are exclusive and in lieu of all other warranties remedies and conditions whether oral written statutory express or implied GLENTRONICS INC disclaims all statutory and implied warranties including without limitation warranties of merchantability and fitness for a particular purpose and warranties against hidden or latent defects to the extent permitted by law GLENTRONICS INC will not be liable for any incidental special or consequential damages for breach of any express or implied warranties on this product In so far as such warranties cannot be disclaimed GLENTRONICS INC limits the duration and remedies of such warranties to the duration of this express warranty and AT GLENTRONICS INC s option the repair or replacement services described below Some states countries and provinces do not allow limitations on how long an implied warranty or condition may last so the limitation described above may not apply to you Any and all causes of action arising from filed as a result of or in reference to this warranty or the products described under this warranty shall be governed by and construed under the laws of the State of Illinois Any cause of action arising from filed as a result of or in reference to this warranty or the products described under this warranty shall be filed only in the Circuit Court of the 18th Judicial District Lak
9. uld be within the length of the pump s power cord and at least 4 feet above the floor level to minimize potential hazards from flood conditions DO protect the electrical cord from sharp objects hot surfaces oil and chemicals Avoid kinking the cord MAKE SURE the supply circuit has a fuse or circuit breaker rated to handle the power requirements noted on the nameplate of the pump To reduce the risk of hazards that can cause injury or property damage observe the following precautions A CAUTION DO NOT expose the control unit to any type of moisture water rain or snow DO NOT operate the pump or control unit if it has been damaged in any way DO NOT use with pumps in pits handling raw sewage salt water or hazardous liquids This product is for use with ground water applications only DO NOT use in continuous duty applications such as fountains or ponds DO NOT disassemble the pump or control unit When service is required contact Glentronics technical support at 800 991 0466 option 3 Return the product to the manufacturer for any repairs at the following address Glentronics Inc 645 Heathrow Drive Lincolnshire IL 60069 NOTICES e The control unit must receive 115V AC 5 and 60 Hz from the AC outlet e The controller will not provide protection during a power outage With the risk of property damage from high water levels the addition of a Basement Watchdog battery backup sump pump system is highly recomm

Download Pdf Manuals

image

Related Search

Related Contents

Adaptador Concentrador HUB Ladrón USB 2.0 7  Télécharger le texte    HDCS-3000S 取扱説明書    KDC-506 - Kenwood  Tecumseh AKA9438ZXA Performance Data Sheet  Tarifa complementaria LT 15/1 (pdf - 1,9 MB) - Schlüter  AEG BC300001M 24 Oven User Manual  Pliego LP 2-2015 Equipos de Laboratorio para el PRONASIDA  

Copyright © All rights reserved.
Failed to retrieve file