Home
Everbilt EFLS20-HD Use and Care Manual
Contents
1. INSTALACI N DE PUNTERA 1 Conecte la tuber a de succi n en la puntera Mantenga el tendido de la tuber a horizontal lo m s corto posible Use cinta Tefl n en las roscas macho de la tuber a Es posible que sean necesarios m ltiples puntos de pozo para brindar agua suficiente a la bomba 2 Instale una v lvula de retenci n en la tuber a horizontal La flecha de flujo en la v lvula de retenci n debe apuntar hacia la bomba Tuber a de descarga Y V lvula de compuerta f O YT O Para cabezas de Para cabezas de AT los aspersores los aspersores gt a V lvula de retenci n Instalaci n punto Driven LT m ltiples puntos as Y ed AA y M ltiple i cabezas Y as ca V TUBER A DEL POZO A LA BOMBA El rendimiento de la bomba disminuir si el di metro de la tuber a es menor que el tama o de la entrada de la bomba Si la instalaci n es adecuada el tama o de la tuber a es igual al tama o de la entrada V Para agregar cebado en instalaciones de punto de pozo instale una v lvula de retenci n de l nea Aseg rese de que la flecha de flujo de la v lvula de retenci n apunte hacia la bomba El tama o de la tuber a de la bomba a la tuber a de descarga de los cabezales del rociador se debe aumentar para reducir las p rdidas de presi n causadas por la fricci n en tendidos largos de tuber a o Tendido de hasta 100 pies 30 5 m Igual tama o que el puerto de descarga de la
2. Inspect the foot or in line check valve to be sure it works freely Inspect the strainer to be sure it is clean and Secure If using a foot valve connect the foot valve and strainer to the first length of suction pipe and lower the pipe into the well Add sections of pipe as needed using Teflon tape on the male threads Use 1 1 2 in pipe for suction pipe Be sure all suction pipe is leak proof or the pump will lose prime and fail to pump Install foot valve 10 to 20 ft 3 to 6 m below the lowest level to which water will drop while the pump is operating pumping water level Your well driller can furnish this information To prevent sand and sediment from entering the pumping system a foot valve strainer should be at least 5 ft 1 5 m above the bottom of the well When proper depth is reached install a sanitary well seal over the pipe and in the well casing Tighten bolts to the seal casing When using a foot valve a priming tee and plug are recommended Priming plug Suction pipe l 1 Priming tee Well seal starting water 20 feet 6m max level pump off Drawdown water level pump on 10 20 feet 3 6m At least 5 feet 1 5m BENE Foot Valve Strainer HOMEDEPOT COM Please contact 1 844 883 1872 for further assistance Installation continued DRIVEN POINT INSTALLATION 1 Connect suction pipe to the drive point Keep the horizontal pipe run as short as possible Us
3. Wiring Connections WARNING Risk of electric shock Can shock burn or kill 1 To avoid dangerous or fatal electrical shock turn OFF power to the motor before working on electrical connections 2 Ground the motor before connecting to electrical power supply Failure to ground the motor can cause severe or fatal electrical shock hazard 3 Supply voltage must be within 1096 of the nameplate voltage Incorrect voltage can cause fire or damage the motor and voids the warranty If in doubt consult a licensed electrician 4 Use a wire size specified in the Wiring Chart below If possible connect the pump to a separate branch circuit with no other appliances on it 5 Do not ground to a gas supply line 6 Wire the motor according to the diagram on the motor cover plate 7 Ifthe diagram on the motor cover plate differs from the diagrams in this section follow the diagram on the motor cover plate 8 If this procedure or the wiring diagrams are confusing consult a licensed electrician RECOMMENDED WIRE AND FUSE SIZES FOR 115 AND 230 VOLTS DISTANCE IN FEET FROM MOTOR TO SUPPLY MAX LOAD BRANCH FUSE AWG MIN WIRE 0 100 101 200 201 300 301 400 401 500 1 1 2 115 230 20 09 10 05 32 15 10 14 5 5 2 6 14 14 2 8 14 8 4 2 6 12 14 3 4 10 21 5 5 4 10 21 5 5 7 HOMEDEPOT COM Please contact 1 844 883 1872 for further assistance Operation WARNING Hazardous Pressure Install a pressure re
4. ados para funcionar a altas temperaturas Est protegida contra da os por calor durante el funcionamiento mediante un interruptor de corte interno autom tico Para evitar quemaduras cuando le d servicio a la bomba deje que enfr e durante 20 minutos despu s de apagarla y antes de manipularla La entrada de succi n de agua de la bomba no debe estar a m s de 20 pies sobre el nivel del agua Los tendidos largos y muchos accesorios aumentan la fricci n y reducen el flujo de agua a la bomba Ubique la bomba lo m s cerca posible a la fuente de agua Use la menor cantidad posible de codos y accesorios Aseg rese de que la l nea de succi n est recta y que se doble hacia la bomba o Aseg rese de que el pozo y la tuber a est n limpios de arena suciedad y costra El material extra o taponar la bomba y anular la garant a Use tuber a nueva para mejores resultados Proteja la bombay toda la tuber a del congelamiento El congelamiento romper la tuber a da ar la bomba y anular la garant a Consulte localmente en busca de requisitos de protecci n L contra la escarcha La bomba no se puede instalar abajo de la profundidad de penetraci n del congelamiento y la bomba debe estar aislada o Las v lvulas de pie o de retenci n no incluidas se deben instalar en la tuber a de succi n para optimizar la succi n de la bomba o Aseg rese de que todas las tuber as y las v lvulas est n limpias y en buen estado o Aseg rese de que
5. 14 3 4 10 21 5 5 4 10 21 5 5 7 HOMEDEPOT COM P ngase en contacto con el 1 844 883 1872 para asistencia adicional Operaci n ADVERTENCIA Presi n peligrosa Instale una v lvula de alivio de presi n en la tuber a de descarga Libere toda la presi n en el sistema antes de trabajar en cualquier componente ADVERTENCIA Riesgo de explosi n y quemaduras NUNCA ponga a funcionar la bomba contra una descarga cerrada Si lo hace puede hacer que hierva el agua dentro de la bomba causando presi n peligrosa en la unidad riesgo de explosi n y posiblemente quemaduras a las N personas que manejan la bomba Reemplace el tap n de NS cebado por un man metro para monitorear la presi n de Y P modo que no se permita que supere las presiones m ximas de bombeo de acuerdo a la tabla de rendimiento 7 Para evitar una explosi n aseg rese de que la descarga v lvula i empu adura de la pistola boquilla de la manguera etc est abierta siempre que est funcionando la bomba Monitoree la temperatura del cuerpo de la bomba y de la tuber a El motor se calentar esto es normal Si el cuerpo de la bomba o la tuber a comienzan a sentirse calientes al tacto apague la bomba y deje que se enfr e el sistema Libere toda la presi n en el sistema y rellene la bomba y la tuber a con agua fr a CEBADO DE LA BOMBA El cebado se refiere a expulsar todo el aire en el sistema y comenzar a mover agua de su fuente
6. a Servicio al Cliente de Everbilt de lunes a viernes de 8 a m a 6 p m hora local del Este 1 844 883 1872 HOMEDEPOT COM GRACIAS Apreciamos la confianza que ha depositado en Everbilt por la compra de esta bomba Nos esforzamos por crear continuamente productos de calidad dise ados para mejorar su hogar Vis tenos en internet para ver nuestra l nea completa de productos disponibles para sus necesidades de mejorar su hogar Gracias por elegir a Everbilt Tabla de contenido Tabla de contenido ais adidas 2 Instalaci n de la bomba tuber a eee 6 Informaci n de seguridad 2 Ajustes el ctricos notti ete erent 7 GAR AINE cse UM EE LM E DEUM E AT 3 Conexiones del cableado erre 1 Pre instalaci n eere 4 Operaci n aan 8 Garnica AA OO E 5 Cuidado y limpieza ssccseccsesceseceseeseeeseeeseeeceseseseeess 9 Instalaci n de la tuber a del pozo 5 Resoluci n de fallas errana 10 Instalaci n de pozo con caja cavado 5 Piezas de servicio iii oen S x ena we sa eES RURN C ER 11 Instalaci n de puntera occccocccnocinionincanonanncnancnnanonnanonca renzo nenas 6 Tuber a del pozo a la bomba enn 6 Informaci n de seguridad ANTES DE OPERAR ESTA BOMBA 1 Evite las quemaduras explosiones de pre
7. al sistema No se refiere nicamente a vertir agua a la bomba aunque vertir agua generalmente es el primer paso la bomba se sobrecaliente da ando el sello y posiblemente causando quemaduras a las personas que manipulan la bomba Llene la bomba con agua antes de arrancarla 1 PRECAUCI N Riesgo de quemaduras NUNCA ponga a funcionar la bomba en seco Poner a funcionar la bomba sin agua puede hacer que 1 Retire el tap n de cebado 2 Aseg rese de que est n abiertas las v lvulas de succi n y de descarga y cualquier manguera en el lado de la descarga de la bomba 3 Llenela bomba y la tuber a de succi n con agua Llene la bomba antes del arranque 4 Vuelva colocar el tap n de cebado usando cinta Teflon en las roscas Apriete el tap n Si se han proporcionado T y tap n de cebado para el tendido largo horizontal llene la tuber a de succi n a trav s de esta T y vuelva a colocar el tap n Use cinta Tefl n en el tap n 5 Arranque la bomba Se debe producir agua en 10 minutos o menos El tiempo depende de la profundidad del agua no m s de 20 pies 6 m y la longitud del tendido horizontal 10 pies 3 m de la tuber a de succi n horizontal 1 pie 30 5 cm de levantamiento vertical debido a p rdidas por fricci n en la tuber a Si no se produce agua en 10 minutos pare la bomba libere toda la presi n retire el tap n de cebado vuelva a llenar e intente de nuevo Cuidado y limpieza Para limpiar la bomba cu
8. are clear of sand dirt and scale Foreign matter will plug the pump and void the warranty Use new pipe for best results Protect the pump and all piping from freezing Freezing will split pipe damage the pump and void the warranty Check locally for frost protection requirements The pump cannot be installed below the frost line and the pump must be insulated Foot or check valves not included must be installed in the suction pipe to optimize pump suction Ensure all pipes and valves are clean and in good shape Ensure there are no air pockets in the suction pipe Ensure there are no leaks in the suction pipe Use Teflon tape or other approved sealants to seal pipe joints Unions installed near the pump and well will aid in servicing Leave room to use wrenches LAWN SPRINKLING APPLICATION This pump is designed for lawn sprinkling When properly installed it will deliver adequate water and pressure from any well source PERFORMANCE DATA DISTANCE OF PUMP ABOVE WATER o O El Xp E ED op DISCHARGE PRESSURE PSI GALLONS PER MINUTE MATERIALS REQUIRED NOT INCLUDED Before using this pump ensure you have the following items 1 1 2 in Suction Discharge pipe Thread sealant tape 1 1 2 in Elbow Union Installation WELL PIPE INSTALLATION Use the installation methods provided in this chapter that match with your water source CASED WELL DUG WELL INSTALLATION 1
9. no hayan bolsas de aire en la tuber a de succi n o Aseg rese de que no hayan fugas en la tuber a de succi n Use cinta Teflon u otro sellador aprobado para sellar las juntas de la tuber a o Las uniones instaladas cerca de la bomba y el pozo ayudar n a darles servicio Deje espacio para poder usar las llaves APLICACI N DE ASPERSI N Esta bomba est dise ada para aspersi n Cuando est instalada adecuadamente entregar agua y presi n adecuadas de cualquier fuente de pozo DATOS DE RENDIMIENTO DISTANCIA DE LA PRESI N DE DESCARGA PSI BOMBA SOBRE fof tH E EL AGUA GALONES POR MINUTO Spies COBH 03J13 Hos 4 3 34 2 HERRAMIENTAS REQUERIDAS NO INCLUIDAS Antes de usar esta bomba aseg rese de tener los siguientes art culos V lvula de retenci n de 1 1 2 pulg Suction Tuber a de descarga de 1 1 2 pulg Codo de 1 1 2 pulg Cinta selladora de roscas Uni n T de cebar si RR de 1 1 2 pulg de 1 1 2 pulg de 1 1 2 pulg Instalaci n INSTALACI N DE LA TUBER A DEL POZO Use los m todos de instalaci n proporcionados en este cap tulo que coincidan con su fuente de agua INSTALACI N DE POZO CON CAJA CAVADO 1 Inspeccione la v lvula de pie o la v lvula de retenci n en l nea para asegurarse de que funcionen libremente Inspeccione el filtro para asegurarse de que est limpio y seguro
10. or strainer are buried in Raise foot valve and or strainer above bottom of water source sand or mud The water level in the well is lower than A deep well jet will be needed if your well is more than 25 ft 7 6M The pump does not deliver water to full capacity estimated depth to water The steel piping if used is corroded or Replace with plastic pipe where possible otherwise with new steel limed causing excess friction pipe The piping is too small in size Use larger piping The pump is not being supplied with enough Add additional well points water The pump leaks The clamp is loose STOP THE PUMP Tighten the clamp nut 1 2 turns Alternately around the clamp tighten and tap on the clamp with a mallet to seat the O ring Do not overtighten 10 Service Parts NO Quantity Part Number 1 1 HDLS15007 0 Ring NBR 2 1 HDLS15008 0 Ring NBR 11 HOMEDEPOT COM Please contact 1 844 883 1872 for further assistance EVERBILI Questions problems missing parts Before returning to the store call Everbilt Customer Service 8 a m 6 p m EST Monday Friday 1 844 883 1872 HOMEDEPOT COM Retain this manual for future use N m de art culo 1001 092 245 N m de modelo EFLS15CI HD EVERBILI GUIA DE USO Y CUIDADO o BOMBA ASPERSORA DE HIERRO FUNDIDO DE 1 1 2 HP Tiene preguntas problemas o faltan piezas Antes de regresar a la tienda llame
11. 872 Claims made under this warranty shall be made by returning the product except sewage pumps see below to the retail outlet where it was purchased or to the factory immediately after the discovery of any alleged defect The manufacturer will subsequently take corrective action as promptly as reasonably possible No requests for service will be accepted if received more than 30 days after the warranty expires Warranty is not transferable and does not apply to products used in commercial rental applications 3 HOMEDEPOT COM Please contact 1 844 883 1872 for further assistance Pre installation BEFORE YOU INSTALL THIS PUMP WARNING Risk of explosion Do not ground to a gas supply line The pump body may explode if used as a booster pump or other than a lawn sprinkling application CAUTION Risk of burns Do not touch an operating motor Motors are designed to operate at high temperatures It is protected from heat damage during operation by an automatic internal cutoff switch To avoid burns when servicing the pump allow it to cool for 20 minutes after shut down before handling o The pump s water suction inlet must not be more than 20 ft above the water level o Long runs and many fittings increase friction and reduce water flow to the pump Locate the pump as close to the water source as possible Use as few elbows and fittings as possible Ensure the suction line is straight and angles up toward the pump o Ensure the well and pipe
12. RE YOU OPERATE THIS PUMP 1 Avoid Pressure Burns Explosion 2 Avoid Electric Shock CAUTION Risk of burns Do not touch an operating motor Motors are designed to operate at high o Fill the pump with water Ensure the pump body is filled with water to discharge temperatures To avoid burns when servicing the pump o Motor s Electrical Settings Set the motor to the proper allow it to cool for 20 minutes after shut down before voltage voltage supplied to the pump handling IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions that must be followed during installation operation and maintenance of this pump Also familiarize yourself with the following safety symbols and their meanings CAUTION Do not allow the pump or any system component to freeze To do so will void the warranty gt CAUTION Only use this pump to pump water DANGER Indicates a hazard which if not avoided will result in death or serious injury CAUTION Periodically inspect pump and system components WARNING Indicates a hazard which if not avoided CAUTION Wear safety glasses at all times when working on pumps PE could result in death or serious injury CAUTION Indicates a hazard which if not avoided could result in minor or moderate injury NOTICE Addresses practices not related to personal injury Carefully read and follow all safety instructions in this manual
13. Si est usando una v lvula de pie conecte la v lvula de pie y el filtro a la primera secci n de la tuber a de succi n y baje la tuber a al pozo Agregue secciones de tuber a seg n sea necesario usando cinta Tefl n en las roscas macho Use tuber a de 1 1 2 pulg para la tuber a de succi n Aseg rese de que toda la tuber a de succi n sea a prueba de fugas o la bomba perder cebado y dejar de bombear Instale la v lvula de pie de 10 a 20 pies 3 a 6 m abajo de nivel m s bajo al cual el agua caer mientras la bomba est funcionando nivel de agua de bombeo Su perforador de pozo le puede proporcionar esta informaci n Para evitar que la arena y sedimentos ingresen al sistema de bombeo una v lvula de pie filtro debe estar al menos a 5 pies 1 5 m sobre el fondo del pozo Cuando se logra el nivel apropiado instale un sello de pozo sanitario sobre la tuber a y en la caja del pozo Apriete todos los pernos en la caja del pozo Cuando use una v lvula de pie se recomienda una T y tap n de cebado Tap n de cebado Tuber a de succi n 1 T de cebado Sello de pozo Inicio del nivel de 20 pies 6m m x agua bomba apagada Disminuci n del nivel de agua bomba apagada i 10 20 pies 3 6m Al menos 5 pies 1 5m V lvula de E pie filtro HOMEDEPOT COM P ngase en contacto con el 1 844 883 1872 para asistencia adicional Instalaci n continuaci n
14. a las instrucciones Hay fugas de aire Revise todas las conexiones en la liinea de succi n y el sello del eje y AVC con crema de afeitar Pare la bomba luego La v lvula de pie o la v lvula de retenci n Cambie v lvula de pie o la v lvula de retenci n revise el cebado antes tiene fugas de buscar otras causas isi el peers El tama o de la tuber a es demasiado Reinstale la tuber a usando el tama o de puertos de succi n e Cebado y vea SIE peque o y descarga en la bomba agua est en el agujero de cebado El nivel del agua est debajo de la entrada Baje la linea de succi n al agua y vuelva a cebar Si el nivel del agua de la tuber a de succi n en retroceso en el pozo supera los 25 pies 7 6 m se necesita una El motor funciona pero no se entrega agua bomba de pozo profundo El impulsor est obstruido Limpie el impulsor La v lvula de pie o la v lvula de retenci n Cambie la v lvula de pie o la v lvula de retenci n est pegada Las tuber as est n congeladas Descongele las tuber as Entierre las tuber as debajo de la l nea de congelamiento Caliente el hoyo o la carcasa de la bomba La v lvula de pie filtro est n enterrados en Levante la v lvula de pie filtro sobre el fondo de la fuente de agua arena o lodo La bomba no entrega El nivel del agua en el pozo es m s bajo que Se necesitar un surtidor de pozo profundo si su pozo tiene m s agua a toda su el estim
15. ado de 25 pies 7 6 m de profundidad al agua capacidad La tuberia de acero si se usa est corroida Reemplace con tuberia pl stica cuando sea posible o con tuberia o encalada causando fricci n excesiva de acero nueva El tama o de la tuber a es demasiado Use tuber a m s grande La bomba no esta siendo alimentada con Agregue puntos de pozo adicionales suficiente agua La bomba tiene fugas La abrazadera est floja PARE LA BOMBA Apriete la tuerca de la abrazadera de 1 a 2 vueltas alrededor de la De forma alterna apriete y golpee la abrazadera con un mazo para abrazadera asentar el anillo O No apriete demasiado 10 Piezas de servicio NO Cantidad 1 1 HDLS15007 Anillo 0 NBR 2 1 HDLS15008 Anillo O NBR 11 HOMEDEPOT COM P ngase en contacto con el 1 844 883 1872 para asistencia adicional Tiene preguntas problemas o faltan piezas Antes de regresar a la tienda llame a Servicio al Cliente de Everbilt de lunes a viernes de 8 a m a 6 p m hora local del Este 1 844 883 1872 HOMEDEPOT COM Conserve este manual para uso futuro
16. and on the pump Keep safety labels in good condition Replace missing or damaged safety labels Warranty The manufacturer warrants to the original consumer purchaser Purchaser or You that its products are free from defects in material and workmanship for a period of twelve 12 months from the date of the original consumer purchase If within twelve 12 months from the original consumer purchase any such product shall prove to be defective it shall be repaired or replaced at the manufacturer s option subject to the terms and conditions set forth herein Note that this limited warranty applies to manufacturing defects only and not to ordinary wear and tear All mechanical devices need periodic parts and service to perform well This limited warranty does not cover repair when normal use has exhausted the life of a part or the equipment The original purchase receipt and product warranty information label are required to determine warranty eligibility Eligibility is based on purchase date of original product not the date of replacement under warranty The warranty is limited to repair or replacement of original purchased product only not replacement product i e one warranty replacement allowed per purchase Purchaser pays all removal installation labor shipping and incidental charges For parts or troubleshooting assistance DO NOT return the product to your retail store contact Everbilt Customer Service at 1 844 883 1
17. ando est atascada con desechos 1 a pi s 92 9 Desenchufe la bomba de la energ a el ctrica Retire los cuatro tornillos 8 Retire la voluta 2 el anillo O 2 el anillo O 3 Retire los tres tornillos 4 que sujetan el difusor 5 a la placa de sello 7 y retire el difusor 5 Retire los desechos alrededor del impulsor 6 Ensamble de nuevo la bomba 9 HOMEDEPOT COM P ngase en contacto con el 1 844 883 1872 para asistencia adicional Resoluci n de fallas El motor no arranca El interruptor de desconexi n est apagado Asegurese de que el interruptor est encendido El fusible ha explotado o el disyuntor de Reemplace el fusible o reajuste el disyuntor de circuito circuito se ha activado El interruptor de arranque est defectuoso DESCONECTE LA ENERG A reemplace el interruptor de arranque Los cables en el motor est n flojos Consulte las instrucciones de cableado DESCONECTE LA ENERG A desconectados o cableados incorrectamente revise y apriete todo el cableado El motor funciona El motor est cableado incorrectamente Consulte las instrucciones de cableado caliente y comienza r m f la Perd 0 el El voltaje esta demasiado bajo Consulte con la compa a de electricidad Instale cableado m s resistente si el tama o del cable es demasiado peque o Consulte motor no funciona i y solo zumba la tabla en la secci n de Cableado La bomba no se ceb correctamente Vuelva a cebar de acuerdo
18. bomba o Tendido de 100 pies a 300 pies 30 5 a 91 4 m Aumentar un tama o de tuber a o Tendido de 300 pies a 600 pies 91 4 a 182 9 m Aumentar dos tama os de tuber a INSTALACI N DE LA BOMBA TUBER A Si se est apagando y encendiendo la bomba por presi n se necesita un interruptor de presi n y tanque Para una instalaci n e instrucciones de operaci n adecuadas llame a Servicio al cliente Use tuber a r gida No use manguera ni tuber a pl stica Consulte Instalaci n de tuber a de pozo para obtener m s informaci n Use solo cinta selladora de rosca de tuber a PTFE para compuestos de junta para hacer todas las conexiones roscadas a la bomba misma No use compuestos de junta de tuber a en bombas pl sticas ya que pueden reaccionar con el pl stico en los componentes de la bomba Aseg rese de que todas las juntas de la tuber a en la tuber a de succi n sean a prueba de aire as como a prueba de agua Si la tuber a de succi n chupa aire la bomba no podr extraer agua del pozo 1 Emperne la bomba en una base s lida y a nivel 3 Coloque de 1 1 2 a 2 capas de cinta Teflon hacia la derecha teniendo enfrente suyo el extremo de la tuber a en todas las roscas macho unidas a la bomba 4 Apriete a mano las juntas m s de 1 1 2 vueltas No apriete demasiado 5 Reemplace el tap n de cebado por un man metro Esto ayudar a dimensionar zonas a resolver fallas y a seguir la tabla de rendimient
19. discharge valves and any hoses on the discharge side of the pump are open 3 Fill the pump and suction pipe with water Fill pump before starting 4 Replace the priming plug using Teflon tape on the threads Tighten the plug If the priming tee and plug have been provided for the long horizontal run fill the suction pipe through this tee and replace the plug Use Teflon tape on plug 5 Start the pump Water should be produced in 10 minutes or less The time depends on the depth to the water not more than 20 ft 6 m and length of horizontal run 10 ft 3 m of horizontal suction pipe 1 ft 30 5 cm of vertical lift due to friction losses in pipe If no water is produced within 10 minutes stop the pump release all pressure remove the priming plug refill and try again Care and Cleaning To clear a pump clogged with debris 1 2 3 4 5 6 Unplug the pump from electrical power Remove four screws 8 Remove the volute 2 O ring 2 and O ring 3 Remove three screws 4 fastening the diffuser 5 to the seal plate 7 and remove the diffuser 5 Remove debris from around the impeller 6 Reassemble the pump 9 HOMEDEPOT COM Please contact 1 844 883 1872 for further assistance Troubleshooting The motor will not run The disconnect switch is off Ensure the switch is on The fuse is blown or circuit breaker tripped Replace the fuse or reset the circuit breaker The starting switch is defecti
20. e Teflon tape on male pipe threads Multiple well points may be necessary to provide sufficient water to the pump Install a check valve in the horizontal pipe The flow arrow on the check valve must point toward the pump Discharge pipe A ee E Gate valve YY gt Do EZ To sprinkler To sprinkler Y Y heads heads A heck valve Driven point installation multiple well points sy CA Gp a Multiple V V well heads V PIPE FROM WELL TO PUMP Pump performance will be decreased if the pipe diameter is less than the inlet size of the pump In proper installation the pipe size equals the inlet size To aid priming on well point installations install a line check valve Be sure the check valve flow arrow points toward the pump Pipe from pump to sprinkler heads discharge pipe size should be increased to reduce pressure losses caused by friction on long pipe runs O Up to 100 ft 30 5 m run Same size as pump discharge port 100 ft 300 ft 30 5 91 4 m run Increase one pipe size 300 ft 600 ft 91 4 182 9 m run Increase two pipe sizes PUMP PIPING INSTALLATION If turning the pump on and off by pressure a pressure switch and tank are required For proper installation and operation instructions call Customer Service Use rigid pipe Do not use hose or plastic tubing See Well Pipe Installation for more information Use only PTFE pipe thread sealant tape to joint comp
21. es apague la energ a al motor antes de trabajar en las conexiones el ctricas 2 Conecte a a tierra el motor antes de conectar a la fuente de alimentaci n el ctrica No conectar a tierra el motor puede causar peligro de choques el ctricos severos o fatales 3 El voltaje de alimentaci n debe estar dentro de 10 del voltaje de la placa de identificaci n El voltaje incorrecto puede ocasionar un incendio o dafiar el motor y anular la garant a Si tiene dudas consulte con N un electricista calificado Use un tamafio de cable especificado en la Tabla de cableado abajo Si es posible conecte la bomba a un circuito de derivaci n aparte sin ningun otro aparato en l No haga la conexi n a tierra a una l nea de suministro de gas Haga el cableado del motor de acuerdo al diagrama en la placa de identificaci n del motor Si el diagrama de la placa de identificaci n difiere de los diagramas en esta secci n siga el diagrama de la placa de identificaci n Si este procedimiento o los diagramas de cableado le resultan confusos consulte con un electricista calificado TAMANOS RECOMENDADOS DE CABLE Y FUSIBLE PARA 115 Y 230 VOLTIOS DISTANCIA EN PIES DEL MOTOR A LA FUENTE MAX AMP FUSIBLE DE AWG M N MP DEL vots DECARGA pERvACI N Tama o pe 120 101 200 201 900 301 400 401 500 ETY AMP CABLE mm TAMA O DE CABLE AWG mm 1 METIO 115 230 20 09 10 05 32 15 10 14 5 5 2 6 14 14 2 8 14 8 4 2 6 12
22. i no se evita podr a resultar en lesiones menores o moderadas AVISO Aborda pr cticas no relacionadas con lesiones personales Lea cuidadosamente y respete todas las instrucciones de seguridad en este manual y en la bomba Mantenga las etiquetas de seguridad en buenas condiciones Reemplace las etiquetas de seguridad faltantes o da adas Garant a El fabricante garantiza al comprador consumidor original Comprador o Usted de esta bomba que estar libre de defectos en materiales y mano de obra durante el periodo de la garant a de doce 12 meses a partir de la fecha de compra del consumidor original Si dentro de doce 12 meses a partir de la compra del consumidor original se comprueba que tal producto est defectuoso ser reparado o reemplazado a la opci n del fabricante sujeto a los t rminos y condiciones decritos aqu Tome nota de que esta garant a limitada aplica a defectos de fabricaci n y no al desgaste y uso normales Todos los dispositivos mec nicos necesitan piezas y servicio peri dico para que se desempe en bien Esta garant a limitada no cubre la reparaci n cuando el uso normal ha agotado la vida de una pieza o del equipo Para determinar la elegibilidad de la garant a es necesario presentar el recibo de compra original y la etiqueta de informaci n de la garant a La elegibilidad est basada en la fecha de compra del producto original y no en la fecha del reemplazo bajo la garant a La garant a est l
23. imitada a la reparaci n o reemplazo del producto original comprado nicamente no al producto de reemplazo o sea un reemplazo de garant a permitido por compra El comprador paga todos los cargos por retiro instalaci n mano de obra env o y cargos incidentales Para piezas o asistencia de resoluci n de fallas NO devuelva el producto a su tienda minorista p ngase en contacto con Servicio al cliente de Everbilt llamando al 1 844 883 1872 Los reclamos hechos bajo esta garant a se har n devolviendo el producto excepto bombas de aguas residuales ver abajo a la tienda minorista donde se compr o a la f brica inmediatamente despu s del descubrimiento de cualquier presunto defecto El fabricante posteriormente emprender acci n correctiva tan pronto como sea razonablemente posible No se aceptar n solicitudes de servicio si se recibe m s de 30 d as despu s de que la garant a expire La garant a no es transferible y no aplica a productos usados en aplicaciones comerciales de alquiler 3 HOMEDEPOT COM P ngase en contacto con el 1 844 883 1872 para asistencia adicional Pre instalaci n ANTES DE INSTALAR ESTA BOMBA ADVERTENCIA Riesgo de explosi n No haga la conexi n a tierra a una l nea de suministro de gas El cuerpo de la bomba puede explotar si se usa como una bomba de carga u otra aplicaci n que no sea la de aspersi n PRECAUCI N Riesgo de quemaduras No toque un motor en funcionamiento Los motores est n dise
24. item 1001 092 245 Model EFLS15CI HD EVERBILT USE AND CARE GUIDE e 1 1 2 HP CAST IRON LAWN SPRINKLER PUMP Questions problems missing parts Before returning to the store call Everbilt Customer Service 8 a m 6 p m EST Monday Friday 1 844 883 1872 HOMEDEPOT COM THANK YOU We appreciate the trust and confidence you have placed in Everbilt through the purchase of this pump We strive to continually create quality products designed to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Everbilt Table of Contents Table of CONtents siii 2 Pump Piping Installation enne 6 Safety Information rere 2 Electrical Settings eene 7 Warranty RRSESERRRRSRSSRRAREESSRRARRSRSSRRRRSRSSRRERRSSSSRERRSRESRRAREERSSRRRRSRES 3 Wiring Connections cecececccccccccccccccccccccnnuncunuccucuceccnnunncnuns 7 Pre installation eere 4 A 8 Installation carried 5 Care and Cleaning A A RR 9 Well Pipe installation cia 5 Troubleshooting a 10 Cased Well Dug Well Installation 5 Service Parts 1 eeeeeeeeee eene nn nnn una rn nnnnrnnananos 11 Driven Point Installation eeeeneee 6 Pipe from Well to Pump eerrnnn nnn 6 Safety Information BEFO
25. lief valve in the discharge pipe Release all pressure on the system before working on any component WARNING Risk of explosion and scalding NEVER run the pump against a closed discharge To do so can boil water to monitor the pressure so that is it not allowed to exceed the maximum pumping pressures according to the performance chart inside the pump causing hazardous pressure in the unit risk of explosion and possibly scalding persons handling o the pump Replace the priming plug with a pressure gauge N Y To prevent explosion be sure the discharge valve pistol grip hose N 7 nozzle etc is open whenever the pump is running Monitor the pump body and piping temperature The motor will warm up this is normal If the pump body or piping begins to feel warm to the touch shut off the pump and allow the system to cool Release all pressure in the system and refill the pump and piping with cold water PRIMING THE PUMP Priming refers to pump expelling all air in the system and beginning to move water from its source out into the system It does not refer only to pouring water into the pump although pouring water in is usually the first step CAUTION Risk of burns NEVER run the pump dry Running the pump without water may cause the pump to overheat damaging the seal and possibly causing burns to persons handling the pump Fill the pump with water before starting 1 Remove the priming plug 2 Make sure suction and
26. o de la bomba NOTA Para tendidos largos de tuber a horizontal instale una T de cebado entre la v lvula de retenci n y la boca del pozo Consulte la figura en la secci n Instalaci n de pozo con caja cavado para referencia adicional el ctricos ADVERTENCIA Desconecte la energ a antes de trabajar en la bomba el motor el interruptor de presi n o el cableado PRECAUCI N El motor puede estar caliente Deje que el motor se enfr e durante 20 minutos despu s de apagarlo PRECAUCI N La presi n del agua se puede acumular en la bomba tuber as o el tanque Drene el agua para liberar la presi n CONFIGURACIONES DEL INTERRUPTOR AZUL Quos BLANCO DEL MOTOR BET AZUL 187 Linea 1 M BLANCO Lb e2 L nea 2 103 Linea 2 Los motores est n dise ados para funcionar a 115 voltios o a 230 voltios S os Asegurese de que la corriente del motor esta configurada para que 115V 60HZ 230V G0HZ coincida con la corriente suministrada a su motor de la fuente de alimentaci n Para asegurarse de que el motor est ajustado a la configuraci n correcta de corriente retire la cubierta trasera del motor e inspeccione la conexiones del cableado para asegurarse de que est n correctamente ajustadas Tornillos de la placa d Cubierta del motor Placa Conexiones del cableado ADVERTENCIA Riesgo de choque el ctrico Puede dar un choque quemar o matar 1 Para evitar choques el ctricos peligrosos o fatal
27. ounds for making all threaded connections to the pump itself Do not use pipe joint compounds on plastic pumps as they can react with the plastic in pump components Make sure that all pipe joints in the suction pipe are air tight as well as water tight If the suction pipe can suck air the pump will not be able to pull water from the well 1 Boltthe pump to solid level foundation N 3 Wrap 1 1 2 to 2 layers of Teflon tape clockwise as you face the end of the pipe on all male threads being attached to pump 4 Tighten joints hand tight plus 1 1 2 turns Do not overtighten 5 Replace the prime plug with a pressure gauge This will aid in sizing zones troubleshooting and following the pump performance chart NOTE For long horizontal pipe runs install a priming tee between the check valve and well head See the figure in the Cased Well Dug Well Installation section for further reference Electrical Settings MOTOR SWITCH SETTINGS BUE S n WHITE E Motors are designed to run on either 115 volt or 230 volt current PE me 1 BLUE 5 a Line 1 Ensure the motor s current is set to match the current being wHiTE 14e Line 2 d Or Line 2 supplied to your motor from the electrical source e o 115V 60HZ 230V 60HZ To ensure your motor is set at the correct current setting remove the motor cover plate from the motor and inspect the wiring connections to ensure they are set correctly Plate Screws Motor Cover Plate
28. si n ADVERTENCIA Riesgo de explosi n El cuerpo de la bomba puede explotar si se usa como una bomba de carga 2 Evite choques el ctricos PRECAUCI N Riesgo de quemaduras No toque un motor O Llene la bomba con agua Asegurese de que la bomba este en funcionamiento Los motores est n dise ados para funcionar llena con agua para descargar a altas temperaturas Para evitar quemaduras cuando le d o Configuraciones el ctricas del motor Ajuste el motor al servicio a la bomba deje que enfr e durante 20 minutos despu s voltaje adecuado voltaje suministrado a la bomba de apagarla y antes de manipularla INSTRUCCIONES DE SEGURIDAD PRECAUCI N No deje que la bomba ni ning n componente IMPORTANTES se congele Hacerlo asi anulara la garant a GUARDE ESTAS INSTRUCCIONES Este manual contiene instrucciones importantes que deben respetarse durante la instalaci n operaci n y mantenimiento de esta bomba Tambi n familiar cese con los siguientes s mbolos de seguridad y sus significados A PRECAUCI N Inspeccione peri dicamente la bomba y los componentes del sistema PELIGRO Indica una situaci n peligrosa que si no se evita resultar en la muerte o lesiones graves PRECAUCI N Use gafas de seguridad en todo momento cuando trabaje con bombas ADVERTENCIA Indica una situaci n peligrosa que si no se evita podr a resultar en la muerte o lesiones graves PRECAUCI N Indica una situaci n peligrosa que s
29. ve DISCONNECT POWER Replace the starting switch The wires at the motor are loose Refer to the Wiring instructions DISCONNECT POWER check and disconnected or wired incorrectly tighten all wiring The motor runs hot and The motor is wired incorrectly Refer to the Wiring instructions overload kicks off or the motor does not run The voltage is too low Check with the power company Install heavier wiring if the wire size is too small See the chart in the Wiring section and only hums The motor runs but no The pump was not primed correctly water is delivered There are air leaks Check all connections on the suction line and shaft seal and AVC with shaving cream Stop the pump then The foot valve or check valve is leakin Replace the foot valve or check valve looking for other Md Unscrew the The pipe size is too small Re pipe using the size of suction and discharge ports on the pump priming plug and see if water is in the priming hole Re prime according to instructions The water level is below the suction pipe Lower the suction line into the water and re prime If receding water inlet level in the well exceeds 25 ft 7 6M a deep well pump is needed The impeller is plugged Clean the impeller The check valve or foot valve is stuck shut Replace the check valve or foot valve The pipes are frozen Thaw pipes Bury the pipes below the frost line Heat pit or pump house The foot valve and