Home Legend HLVP2006 Installation Guide
Contents
1. Date Purchase Retailer Name Retailer Address City State ZIP Code Installer Doc ID 185 Rev 2 Effective 4 1 2015 Page 8
2. groove of the floor panel in the previous row e Fold the floor panel gently down Step 7 e Place the short end tongue of the next floor panel at an angle against the previously installed floor panel and fold gently down e Ensure that the long side tongue is positioned on the locking strip of the previous row Step 8 e Using gentle force and at an angle you gradually from left to right push the long side tongue into the locking groove of the previous row e You may need to lift the floor panel to the left of it slightly to allow for the sliding action e Complete the whole row in the same way Note Expansion gaps around pipes e Measure the diameter of the pipes and mark the position on the floorboard There should be a 3 16 to 5 16 inch expansion gaps between the floor panel and the pipe or other vertical structures e Cut out the holes Door frames may have to be undercut e Use a floor panel as a guide as to how much to saw e Put the floor panel faced down as a guide e Saw off the bottom of the door frame to allow the floor panel to slide under it Doc ID 185 Rev 2 Effective 4 1 2015 ae Ni aN first click short side gt gt N y ae gt then gradually click long side then gradually click long Page 5 Glue Down Installation Installation Overview e The main difference between floating and glue down method i
3. walking on the floor CLIMATE MAINTENANCE Care should be taken to control temperature Extreme temperature changes may result in unacceptable thermal expansion or contraction FLOOR REPAIR Very light and small surface scratches can be repaired with a staining touch up pen of the appropriate color Slightly deeper scratches can be repaired by means of colored putty and or stains Fill the scratches with the putty Level with putty knife Wipe off excess putty Very deep scratches may require the replacement of the planks Doc ID 185 Rev 2 Effective 4 1 2015 Page 7 Warranty This flooring product comes with a Home Legend Limited Wear Warranty The warranty applies to original purchaser of the flooring It warrants the original purchaser that the finish surface will not wear through for duration of the stated warranty from the date of purchase Please contact our Customer Service Representative by calling our toll free number or send in the warranty registration below for a written copy which provides detail terms of coverage and limitations WARRANTY REGISTRATION UPON RECEIPT OF THIS REGISTRATION FORM AND COPY OF RECEIPT WE WILL SEND YOU A WRITTEN WARRANTY DOCUMENT SEND THE COMPLETED FORM ALONG WITH A COPY OF PROOF OF PURCHASE TO HOME LEGEND LLC WARRANTY REGISTRATION P O BOX 887 ADAIRSVILLE GA 30103 Customer Name Customer Address City State ZIP Code Phone E mail Product Model Number Product Description
4. A TIMELESS CHOICE Installation Instructions Luxury Vinyl Tiles LVT Visit homelegend com for latest version of installation instructions Home legen Products Included Approved Grade Levels Approved Installation Methods Luxury Vinyl Tiles Above Grade Primary Method Floating 3 2 mm products On Grade Optional Method Full Spread Glue Below Grade CAUTION ASBESTOS IN EXISTING FLOOR Home Legend product does not contain asbestos Existing installed resilient flooring and asphaltic adhesive may contain asbestos fillers or crystalline silica Do not sand dry sweep dry scrape drill saw bead blast or mechanically chip or pulverize existing resilient flooring backing lining felt asphaltic cutback adhesive or other adhesive See Recommended Work Practices for Removal of Resilient Floor Coverings rfci com for detailed information and instructions on removing all resilient covering structures Owner Installer Responsibility The owner is advised to be at home during the installation for consultation direction The owner and installer should discuss installation and layout to maximize satisfaction If this is not possible consultation should be done prior to installation The owner installer assumes all responsibility for product quality of completed installation PERFORM PRE INSTALL INSPECTION FOR CLAIMS PURPOSES YOU ARE ALLOWED TO OPEN UP TO 4 BOXES FOR PRODUCT INSPECTION DO NOT OPEN ALL THE BOXES OPENING ALL THE B
5. OXES CONSTITUTES YOUR ACCEPTANCE OF THE PRODUCT INSPECT ALL THE PLANKS IN THESE 4 BOXES CAREFULLY EXAMINE FLOORING FOR COLOR FINISH AND QUALITY IF YOU DISCOVER THAT PRODUCTS ARE DEFECTIVE OR IF MATERIAL IS QUESTIONABLE YOU SHOULD CONTACT THE RETAILER IF YOU ARE SATISFIED PROCEED WITH INSTALLATION Flooring to be installed in one large area should be purchased at the same time Product purchased at a later time than the first purchase may vary beyond your expectations This product is manufactured according to strict quality standards In the event that defects are discovered in the field the industry standards permit a defect tolerance not to exceed 5 Order an additional 5 10 extra for diagonal installations for cutting wastage and plank replacement when the floor is in service During installation inspect the planks continuously Defects that can be seen from a standing position should be cut off or held out Installing defective planks implies acceptance If You Need More Information To assure the warranty is not inadvertently voided before proceeding with any activity that is not covered in this manual please contact our Technical Support Department Acclimation and In service Conditions Acclimate the flooring in unopened box for 48 hours at ideal room temperature range between 60 F 75 F Conditions in which the floor was acclimated should be maintained continuously thereafter Avoid drastic temperature changes as they may cause t
6. ab or ground must be dry The ground in the crawl spaces must be completely covered using 6 mil black polyethylene Crawl space clearance between the earth and underside of joists should be no less than 18 inches and the perimeter vent area should be equal to 1 5 of the total square footage of the crawl space or as mandated by code Concrete Subfloor Requirements It must have minimum rated strength of 3000 psi It must be level to within 1 8 in a 6 foot span or 3 16 in a 10 foot span no bumps or low spots High spots can be removed by grinding Gaps greater than 5 32 wide and 1 16 and depressions should be filled with patching compound formulated for use in floor installation It must be clean no construction debris soil mud and any other objects on or adhering to the floor if necessary scrape and sweep away before the installation no protrusions of nails debris metals should remain New concrete slab must cure for at least 60 days It must have a minimum 10 mil polyethylene sheet between the ground and the concrete It must meet concrete moisture requirement below It must be free from moisture related conditions which can damage the installed flooring Light Weight Concrete It is concrete which rated strength is less than 3000 psi Perform a quick check by drawing a nail across the top if it leaves indentation it is probably light concrete For glue down application the concrete must possess shear strength greater than the g
7. amages Repair all shortcomings before installation It must be flat no visible bumps or low spots the subfloor should be flat to within 1 8 in 6 feet span or 3 16 in 10 feet It must be dry Plywood or Oriented Strand Board OSB Specifications On truss joist spacing of 16 406mm O C or less the industry standard for single panel subflooring is minimum 5 8 19 32 15 1 mm CD Exposure 1 plywood subfloor panels CD Exposure 1 or 23 32 OSB Exposure 1 subfloor panels 4 x 8 sheets Expansion gap between panels should be 1 8 3 mm When subfloor panels spacing is inadequate cut in the required spacing with a circular saw if the panels are not Doc ID 185 Rev 2 Effective 4 1 2015 Page 2 tongued and grooved Do not cut in expansion space on joined tongue and groove of panels Particle Board or Fiber Board Only for floating installation Existing Floors Installation over existing floor requires the installer to consider potential issues related to moisture damage adhesive failure and fastener failure Contact the adhesive and fastener manufacturers respectively for their specific instructions recommendations and requirements Acceptable floor coverings include solid hardwood linoleum terrazzo ceramic tile and other moisture sealing floors Unacceptable floor coverings include carpet needle punch felt edge glued linoleum and other moisture absorbing flooring Radiant Heated Subfloor This product
8. can be installed over radiant heated subfloor Heating system must be in operation at least for 7 days prior to installation Decrease temperature before installation Increase temperature gradually after installation Operating surface temperature must be less than 84 F Contact heater manufacturer for specific installation instruction Moisture Barrier and Moisture Retarder Concrete Subfloor For floating installation use 6 mil polyethylene film or other means with equivalent permeability Overlap the edge seams and tape it together Extend moisture barrier up to the wall about 1 inch high When installed on above grade concrete and the moisture content meets standards for concrete moisture a moisture barrier is not required For direct glue installation use a moisture barrier if moisture level exceeds requirement see Concrete Moisture section above Wood Subfloor Not required Sound Control Underlayment It is optional Check with sound control manufacturer for application guidelines Generally the less compressive underlayment is preferred Expansion Gap Required gap width range is 5 16 to 3 8 It is required around the perimeter of the floor and between floor and all vertical obstructions Do not place permanently installed structures such as kitchen counter cabinet on the installed floor Wet Areas This product can be installed in kitchens mud rooms powder rooms bathrooms and laundry rooms Do not install in saunas swimming po
9. he vinyl planks to expand and contract excessively resulting in gaps Best practice is to keep in service temperatures to as close possible to the temperature at time of acclimation Conditions to avoid Outdoor use sunrooms solariums saunas We also recommend not to install the product in rooms that are not temperature controlled Avoid long lasting exposure to direct sunlight Extreme solar exposure heat and extreme temperature changes can damage the flooring Date of installation Temperature F Subfloor Type Job Site Condition Prior to installation the installer must ensure that at the time of installation the job site conditions including subfloor substrate ambient temperature and relative humidity and all impacting variables will not negatively affect floor Home Legend will decline responsibility for damages associated with improper installation or poor site conditions Storage and Conditions Doc ID 185 Rev 2 Effective 4 1 2015 Page 1 Do not store flooring in uncontrolled environmental conditions For example garages and exterior patios are not acceptable areas to store flooring Handle and unload flooring with care and store within the environmentally controlled site in which it is expected to perform Flooring stored on concrete slab should be elevated at least four inches to allow air circulation under cartons Existing Home Existing home should have a consistent room temperature of 60 F 75 F and relative
10. humidity RH of 35 55 Continual extreme deviation from these conditions will affect the dimensions of flooring During heating season humidity may be much lower than the acceptable range During the heating season a humidifier is recommended to prevent excess shrinkage in flooring due to low humidity levels During the non heating season humidity levels can be maintained by using an air conditioner dehumidifier or by turning on your heating system periodically New Construction or Remodel All work involving water such as pouring basement concrete floors drywall and plasterwork plumbing etc must be completed well in advance of the floor delivery Ensure that the building is enclosed Where building codes allow permanent heating and or air conditioning systems should be operating at least five days preceding installation to promote proper acclimation and should be maintained during and after installation If it is not possible for the permanent heating and or air conditioning system to be operating before during and after installation a temporary heating and or dehumidification system that simulate normal living occupied conditions can enable the installation to proceed until the permanent heating and or air conditioning system is fully operational Your job site should have a consistent temperature of 60 F 75 F and relative humidity RH of 35 55 which should be maintained continuously thereafter Basements and Crawl Spaces Concrete sl
11. lue If concrete rated psi is unknown contact the adhesive manufacturer for guidance Concrete Moisture All concrete subfloors should be tested for moisture content and the results documented Visual checks are not reliable Perform tests at locations around exterior doorways near walls containing plumbing near foundation walls and in the center of the room Minimum sample size is 3 samples per 1000 square feet of area and one test for every additional 1000 square feet thereafter Its moisture content should meet one of the following criteria below e 5 when tested using Tramex Concrete Moisture Encounter e Less than 3 pounds per 1000 square feet per 24 hours when using Calcium Chloride test ASTM F 1869 e 75 when using Relative Humidity Testing ASTM F 2170 Please note Concrete moisture content may be acceptable the time of the test These tests do not guarantee a perpetual dry concrete slab The concrete slab moisture content can vary at other times of the year We are not responsible for moisture related damage to installed flooring Wood Subfloor Requirements It must be clean no presence of construction debris soil mud and any other objects on or adhering to the floor no protrusions of nails debris metals should remain If necessary scrape and sweep the subfloor before the installation It must be structurally sound and stable no movements or squeaks no loose panels or loose nails no signs of ply de lamination or other d
12. nish especially when it has dried It is extremely important to take precautionary steps NOT to leave finger prints or footprints marks on the face of the board If glue comes in contact with the face of the board remove immediately with the adhesive remover recommended by the adhesive manufacturer Use clean towels changing frequently to prevent haze and adhesive residue If the spot removal damages the appearance of the boards replace the board Helpful Pointers General Tips e Make sure your work area is well lit Good visibility ensures that color is consistent and that visually defective planks are detected and removed e Preferred minimum length of the first and last plank is 12 The remainder of the last plank can be used as a starter board on the following rows Doc ID 185 Rev 2 Effective 4 1 2015 Page 3 e Using a shorter piece at undercut door jams will help when fitting flooring in place Glue Down Installation Tips e ALWAYS REFER TO THE SPECIFIC INSTRUCTIONS ON THE FLOORING ADHESIVE LABEL The information given here is for typical installation Adjust it according to adhesive manufacturer s instruction e Dry lay means the glue has to set before placing floor planks in it Wet lay means the glue does not need to set before placing floor on it e Use trowel design as specified by adhesive manufacturer e Continuously check the transfer of adhesive THROUGHOUT the installation process If the adhesive no longer transfers
13. ol areas and other similar extreme wet areas Fill all expansion gaps with water repellant caulk Adhesive Water based acrylic glue and designed for gluing PVC LVT and other vinyl based flooring Tools and Materials Basics Utility knife chalk line chalk pencil T square tape measure spacers broom hand saw or jamb saw eye protection work gloves Additional Supplies for Glue Down Method Flooring adhesive Trowels e Adhesive remover for selected adhesive Clean rags e Weight roller e 3M Blue tape Safety and Health Precautions Power tools can be dangerous Operate in strict accordance to manufacturer s operating instructions and safety precautions Unsafe and improper use can cause serious injuries Avoid inhalation and exposures to wood dust by mechanical means and by wearing personal protective equipment Wear appropriate personal protective equipment PPE which include NIOSH or OSHA approve dust masks safety goggle and work gloves Bond Failure Bond failure is NOT flooring product defect Most installation failures including bond failure result from jobsite moisture Do not unpack or deliver flooring to the jobsite until moisture problems are corrected Read adhesive manufacturer s instruction carefully Not following the adhesive manufacturer s recommendations can lead to installation failure or product damage and will void your warranty Glue Spots on Face of Finished Floor Adhesive can damage the floor s fi
14. p residual water completely CAUTION Floor will be slippery when wet Do not use acetone i e nail polish remover or other strong solvent Do not use chlorinated solvents Do not use wax or varnish coating Do not leave any amount of liquids water juice soft drinks spills etc on the floor Clean any wet spots immediately Do not use steel wool or scouring powder which will scratch the floor BRANDED OFF THE SHELF FLOOR CARE PRODUCT If you choose to use a store bought product test the product in a non conspicuous area i e closet corner or scrap pieces for potential adverse side effects PREVENTIVE MAINTENANCE Protect your floor when using a dolly for moving furniture or appliances Protective sheets and or plywood may be needed Never slide or roll heavy furniture or appliances across the floor Place protective pads beneath furniture legs and other heavy objects Do not use rubber backed rugs Minimize abrasive material and dirt by placing mats on both sides of exterior doors and by using area rugs in high traffic areas Rearrange furniture and rugs periodically to avoid uneven color and shade changes from light exposure Avoid exposure to extreme sunlight Close curtain or blinds during such times Use protective mats beneath rolling chairs Keep furniture casters clean Use soft non rubber wheels for office chairs Keep pets nails trimmed Remove shoes with cleats spikes or exceptionally pointy heels before
15. s the additional spreading of the glue on the subfloor e Do not spread glue on more area than you can work with e An area the size of two installed rows is a good starting area e The steps described in the floating installation are the same for glue down installation e Always follow adhesive manufacturer s instruction Installation Procedure e Spread the glue width of two initial starter rows e Install the first row of planks e Install the second row Ensure you are locking the edges e Spread another section of glue e Install another two rows e Repeat spreading glue install planks cycle until all flooring has been installed Technical Support For installation information and technical questions not covered in this installation guide please contact our Technical Support Representative by calling the toll free number below Toll Free Number 877 630 1800 Doc ID 185 Rev 2 Effective 4 1 2015 Page 6 CARE AND MAINTENANCE GUIDE Luxury Vinyl Tiles LVT DAILY MIAINTENANCE a ae Sweep dust mop or vacuum your floor regularly to remove any particles that could cause abrasion or scratch your floor CAUTION Vacuums with a beater bar or power rotary brush head can damage a floor and should never be used Use a damp mop to remove spots and soil For difficult to clean spots or stains use solution of mild detergent or cleaner marketed and sold to be used for luxury vinyl tiles flooring Rinse thoroughly and soak u
16. to the back of the flooring material it must be removed and new adhesive applied e Work your way out of the room e After the installation is completed keep the floor free from daily foot traffic for a minimum of 24 hours to allow adhesive to properly cure Cutting the Last Row to Width e Most often the entire length of the last row will need to be cut so that it is narrow enough to fit the remaining space e Measure the distance between the floor face edge exclude the tongue to the wall Subtract 5 16 3 8 from this measurement for expansion gap Draw a line Cut through the line Discard the excess piece Proceed with installation Floating Installation Step 1 Pre install Activities e Ensure that the width of first and last row is not less than 2 inches wide Measure the distance of room in the direction of the width of the plank Divide the distance by the width of the plank Multiply the number beyond the decimal point of the by the width of the plank This is the width of the last plank If it is less than 2 inches you must cut the first plank Determine the width of the first and the last row by adding the calculated width of the last plank to the width of a whole plank Divide this number by two Subtract the expansion gap from the result The result is the width of the first and last row Rack up planks from several boxes Ensure that end joints are staggered at least 12 between the rows Inspect product for defec
17. ts If material is questionable contact the retailer immediately Do not proceed with installation Step 2 e Cut off the unsupported tongue of the first row so that a clean solid edge is towards the wall e If the first row of floor panels had already been trimmed in width to meet minimum requirement there is no need to trim it again Step 3 e Install the product from left to right across the room e Place the floor panel with the locking groove facing the room e Ensure there is expansion gaps Between floorand the wall and all vertical fixtures during installation Step 4 e Place the short side tongue of the next floor panel at an angle into the short side groove of the first one and fold down e Continue with the next floor panels in the same way Step 5 e Place the final floor panel face up locking groove long side towards the wall and the short end tongue posi tioned 3 16 to 5 16 inch from the wall e Mark the place where the floor panel is to be cut e Make a cut in the floor panel on the decor side with a utility knife Use the snap method to break the unneeded part off Doc ID 185 Rev 2 Effective 4 1 2015 Step 6 e Stagger the end joints between rows at a minimum 12 inches e f you can use the cut piece of floor panel from the previous row If not suitable take a new floor panel and cut it in half e Place the floor panel at a low angle and insert the long side tongue into the locking