1. 1 Mark lines 2 1 3 cm and 434 12 1 cm from the back wall on the centerline of the underside of cabinet 2 Mark lines 5 13 3 cm to the right and left of the centerline on the underside of cabinet 3 Use saber or keyhole saw to cut a rectangular opening for vent 2 1 3 cm 133 gy 138 13 3 cm From wall not cabinet frame To make a circular vent opening on the underside of the cabinet top 1 Mark a centerline on the underside of the top of cabinet 2 Mark a line 5 12 7 cm from the back wall on the underside of the top of cabinet 3 Use a compass or a circle template to draw a circle with a diameter that is 1 4 0 64 cm larger than the vent 4 Use saber or keyhole saw to cut the circular vent opening Circular vent opening Cabinet cutouts From wall not cabinet frame Install Vent System 1 Install vent through the vent opening in upper cabinet or wall Complete venting system according to the selected venting method See Venting Requirements section 2 Use caulking to seal exterior wall or roof opening around the cap Complete Preparation 1 Remove the grease filters See the Range Hood Care section m Depending on your installation remove either top or rear rectangular vent knockout If using round vent remove top rectangular knockout m Make sure damper pivot is nearest to top back edge of range hood m Remove tape from dam
2. Autour de la bouche de d charge l ext rieur par un mur ou par le toit assurer l tanch it avec un produit de calfeutrage Installations pour r gions climat froid On doit installer un clapet anti reflux additionnel l arri re pour minimiser le reflux d air froid et incorporer un l ment d isolation thermique pour minimiser la conduction de chaleur par l interm diaire du conduit d vacuation de l int rieur de la maison l ext rieur Le clapet anti reflux doit tre plac du c t air froid par rapport l l ment d isolation thermique L l ment d isolation thermique doit tre aussi proche que possible de l endroit o le syst me d vacuation s introduit dans la partie chauff e de la maison Air d appoint Le code du b timent local peut exiger l emploi d un syst me d appoint d air lors de l emploi d un ventilateur d extraction dont la capacit d aspiration est sup rieure un d bit pieds cubes par minute sp cifi Le d bit sp cifi pieds cubes par minute est variable d une juridiction une autre Consulter un professionnel des installations de chauffage ventilation climatisation au sujet des exigences sp cifiques applicables dans la juridiction locale M thodes d vacuation La sortie l ext rieur du circuit d vacuation peut se faire travers le toit ou travers un mur Utiliser un conduit rectangulaire de 374 x 10 8 3 cm x 25 4 cm pour une longueur effective maximale de
3. ce num ro 31462A GARANTIE DES GROS APPAREILS M NAGERS WHIRLPOOL CORPORATION GARANTIE LIMIT E Pendant un an compter de la date d achat lorsque ce gros appareil m nager est utilis et entretenu conform ment aux instructions jointes ou fournies avec le produit Whirlpool Corporation ou Whirlpool Canada LP ci apr s d sign es Whirlpool paiera pour les pi ces sp cifi es par l usine et la main d uvre pour corriger les vices de mat riaux ou de fabrication Le service doit tre fourni par une compagnie de service d sign e par Whirlpool Cette garantie limit e est valide uniquement aux tats Unis ou au Canada et s applique exclusivement lorsque l appareil est utilis dans le pays o il a t achet l ext rieur du Canada et des 50 tats des tats Unis cette garantie limit e ne s applique pas Une preuve de la date d achat original est exig e pour obtenir un service dans le cadre de la pr sente garantie limit e ARTICLES EXCLUS DE LA GARANTIE La pr sente garantie limit e ne couvre pas 1 Les visites de service pour rectifier l installation du gros appareil m nager montrer l utilisateur comment utiliser l appareil remplacer ou r parer des fusibles ou rectifier le c blage ou la plomberie du domicile 2 Les visites de service pour r parer ou remplacer les ampoules lectriques de l appareil les filtres air ou les filtres eau Les pi ces consomptibles ne sont pas couvertes par la garanti
4. circuit de 35 pi 10 7 cm ou un conduit rond de 6 15 2 cm ou plus de diam tre pour une longueur effective maximale de circuit de 50 pi 15 2 m REMARQUE On d conseille l emploi d un conduit flexible Un conduit flexible peut susciter une r tro pression et des turbulences de l air ce qui r duit consid rablement la performance D charge travers le toit A E mU B i D A Conduit rond de diam tre 6 15 2 cm ou plus ou conduit rectangulaire de 3 x 10 8 3 x 25 4 cm travers le toit B Conauit rond utiliser un clapet rond de 6 15 2 cm ou plus de diam tre achat s par C Conduit rond Utiliser un raccord de transition de 3 x 10 8 3 x 25 4 cm sur 6 15 2 cm ou de plus grande taille achat s par D 24 61 cm 30 76 2 cm au dessus de la surface de cuisson lectrique 27 68 6 cm 30 76 2 cm au dessus de la surface de cuisson au gaz E Bouche de d charge sur toit D charge travers le mur A C om E iy ES A Conduit de diam tre 6 15 2 cm ou plus ou conduit rectangulaire de 3 x 10 8 3 X 25 4 cm a travers le toit B Conduit rond Utiliser un raccord de transition de 3 x 10 8 3 x 25 4 cm sur 6 15 2 cm ou de plus grande taille C Sortie a travers le mur pour conduit rectangulaire de 3 x 10 8 3 x 25 4 cm D 24 61 cm 30 76 2 cm au dessus de la surface de cuisson
5. cm 2 pi 0 6 Bouche de 5 S PECLS m gt d charge murale Longueur maximale recommand e 35 pi 10 7 m 1 coude 90 5 pi 1 5 section droite de 8 pi 2 4 m 8 pi 2 4 m 1 bouche de d charge murale 0 pi 0 m Longueur du syst me de 3 10 13 pi 3 9 m 8 3 cm x 25 4 cm Observer les dispositions de tous les codes et r glements en vigueur V rifier que l installation lectrique a t correctement effectu e et qu elle est conforme aux sp cifications de la plus r cente dition des normes National Electrical Code ANSI NFPA 70 ou de la norme CSA C22 1 94 Code canadien de l lectricit partie 1 et C22 2 N 0 M91 derni re dition et de tous les codes et r glements en vigueur locaux Si les codes le permettent et si on utilise un conducteur distinct de liaison la terre il est recommand qu un lectricien qualifi v rifie la qualit de la liaison la terre Pour obtenir un exemplaire de la norme des codes ci dessus contacter National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 m L appareil doit tre aliment par un circuit de 120 V CA seulement 60 Hz 15 A prot g par fusible m Sile domicile est quip d un c blage en aluminium suivre les instructions suivantes 1 Connecter une section de c ble en cuivre massif aux conducteurs en queue
6. configur e l usine pour une installation avec d charge l ext rieur Pour une installation sans d charge l ext rieur recyclage l ensemble de recyclage est inclus Voir la section Assistance ou service pour commander un filtre charbon de rechange pi ce n W10272068 m Assurer l tanch it au niveau de chaque ouverture d coup e dans le plafond ou le mur pour l installation de la hotte de cuisini re Installation dans une r sidence mobile L installation de cette hotte de cuisini re doit satisfaire aux exigences de la norme Manufactured Home Construction Safety Standards Titre 24 CFR partie 328 anciennement Federal Standard for Mobile Home Construction and Safety titre 24 HUD partie 280 lorsque cette norme n est pas applicable l installation doit satisfaire aux crit res de la plus r cente dition de la norme Manufactured Home Installation 1982 Manufactured Home Sites Communities and Setups ANSI A225 1 NFPA 501A ou des codes et r glements locaux Product Dimensions 12 291546 CS 1 i d 3 8 500 cm di 17 Installation Clearances 18 A D gagement min de 18 45 7 cm entre le placard sup rieur et le plan de travail B Distance maximale sugg r e du bas de la hotte la surface de cuisson 24 61 cm min pour surfaces de cuisson lectriques 27 68 6 cm min pour surfaces de cuisson au gaz 30 7
7. cooking vapors and odors from the cooktop area For best results start the hood before cooking and allow it to operate several minutes after the cooking is complete to clear all smoke and odors from the kitchen The hood controls are located on the front panel on the right side of the range hood A C n D B A Fluorescent lamp housing B Grease filter handle C Blower and light controls D Grease filter 990 A On Off light button B Blower Off and speed minimum button C Blower speed medium button D Blower speed maximum button Operating the light The On Off light button controls the light Press once for On and again for Off Operating the blower The BLOWER SPEED buttons turn the blower on and control the blower speed and sound level for quiet operation The speed can be changed anytime during fan operation by pressing the desired blower speed button Press the BLOWER OFF button a second time to turn the blower off RANGE HOOD CARE IMPORTANT Clean the hood and grease filters frequently according to the following instructions Replace grease filters before operating hood Exterior Surfaces IMPORTANT Do not use soap filled scouring pads abrasive cleaners Cooktop Polishing Creme steel wool gritty washcloths or paper towels To avoid damage to the stainless steel do not use cleaners that contain chlorine Cleaning Method mg Rub in direction of grain to avoid scratching or damaging
8. cord or plug Discard fan or return to an authorized service facility for examination and or repair Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other utilities Ducted fans must always be vented outdoors CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls or ceilings attics or into crawl spaces or garages WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE m Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings m Always turn hood ON when cooking at high heat or when flambeing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flamb m Clean ventilating fans frequently Grease should not be allow
9. de cochon 2 Connecter le c blage en aluminium la section ajout e de c blage en cuivre en utilisant des connecteurs et ou des outils sp cialement con us et homologu s UL pour fixer le cuivre l aluminium Appliquer la proc dure recommand e par le fabricant des connecteurs La connexion aluminium cuivre doit tre conforme aux codes locaux et aux pratiques de c blage accept es par l industrie m Le calibre des conducteurs et les connexions doivent tre compatibles avec la demande de courant de l appareil sp cifi e sur la plaque signal tique La plaque signal tique de l appareil est situ e derri re le filtre sur la paroi arri re de la hotte Le calibre des conducteurs doit satisfaire aux exigences de la plus r cente dition de la norme National Electrical Code ANSI NFPA 70 ou de la norme CSA C22 1 94 Code canadien de l lectricit partie 1 et C22 2 n 0 M91 derni re dition et de tous les codes et r glements en vigueur INSTRUCTIONS D INSTALLATION REMARQUE I est recommand d installer le syst me d vacuation avant de proc der l installation de la hotte Avant d ex cuter les d coupages v rifier la disponibilit d un d gagement suffisant dans le plafond ou le mur pour le conduit d vacuation 1 D connecter la source de courant lectrique 2 D terminer la m thode d vacuation utiliser travers le toit ou travers le mur 8 S lectionner une surface plane
10. fabricant m Avant d entreprendre un travail d entretien ou de nettoyage interrompre l alimentation de la hotte au niveau du tableau de disjoncteurs et verrouiller le tableau de disjoncteurs pour emp cher tout r tablissement accidentel de l alimentation du circuit Lorsqu il n est pas possible de verrouiller le tableau de disjoncteurs placer sur le tableau de disjoncteurs une tiquette d avertissement pro minente interdisant le r tablissement de l alimentation m Tout travail d installation ou c blage lectrique doit tre r alis par une personne qualifi e dans le respect des prescriptions de tous les codes et normes applicables y compris les codes du b timent et de protection contre les incendies m Ne pas faire fonctionner un ventilateur dont le cordon ou la fiche est endommag e Jeter le ventilateur ou le retourner un centre de service agr pour examen et ou r paration m Une source d air de d bit suffisant est n cessaire pour le fonctionnement correct de tout appareil gaz combustion et vacuation des gaz combustion par la chemin e pour qu il n y ait pas de reflux des gaz de combustion Respecter les directives du fabricant de l quipement de chauffage et les prescriptions des normes de s curit comme celles publi es par la National Fire Protection Association NFPA et l American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et les prescriptions des autorit s r
11. glementaires locales Lors d op rations de d coupage et de percage dans un mur ou un plafond veiller ne pas endommager les c blages lectriques ou canalisations qui peuvent s y trouver Les ventilateurs d vacuation doivent toujours d charger l air l ext rieur MISE EN GARDE Cet appareil est congu uniquement pour la ventilation g n rale Ne pas l utiliser pour l extraction de mati res ou vapeurs dangereuses ou explosives MISE EN GARDE Pour minimiser le risque d incendie et vacuer ad quatement les gaz veiller acheminer l air aspir par un conduit jusqu l ext rieur ne pas d charger l air aspir dans un espace vide du b timent comme une cavit murale un plafond un grenier un vide sanitaire ou un garage AVERTISSEMENT POUR R DUIRE LE RISQUE D INCENDIE UTILISER UNIQUEMENT DES CONDUITS METALLIQUES AVERTISSEMENT POUR MINIMISER LE RISQUE D UN FEU DE GRAISSE SUR LA CUISINI RE m Ne jamais laisser un l ment de surface fonctionner puissance de chauffage maximale sans surveillance Un renversement d bordement de mati re graisseuse pourrait provoquer une inflammation et la g n ration de fum e Utiliser une puissance de chauffage moyenne ou basse pour le chauffage d huile Veiller toujours faire fonctionner le ventilateur de la hotte lors de la cuisson avec une puissance de chauffage lev e ou lors de la cuisson d un mets flamber savoir cr pes Suzette cerise jubil e
12. gt Whirlpool 30 76 2 CM RANGE HOOD HOTTE D ASPIRATION DE 30 76 2 CM IMPORTANT READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY IMPORTANT LIRE ET CONSERVER CES INSTRUCTIONS POUR UTILISATION RESIDENTIELLE UNIQUEMENT ENERGY STAR LI3Y5A W10320576A TABLE OF CONTENTS RANGE HOOD SAFETY 3 INSTALLATION REQUIREMENTS 4 Tools and Parts u uum tee reete tes 4 Location Requirements 4 Venting Requirements cono nrnncnnnncnnnn 5 Electrical Requirements esses enn 7 INSTALLATION INSTRUCTIONS 7 Pr par Locations u ocio cote peter o enne rta nd eve Pene Pene go 7 Install Range Flood eee Pap 9 Make Electrical Connection 10 Complete Installation sess 10 RANGE HOOD USE uuu irent 11 Range Hood Controls iai 11 RANGE HOOD CARE 11 CICA ING 11 WIRING DIAGRAM u u ne tan en er sens 12 ASSISTANCE OR SERVICE 13 Inthe USA nn eee ins ev eee 13 In Ganada init ener dece weeded 13 ACCOSSOrIGS feos i
13. la hotte l aide de vis de t lerie A Conduit vertical B Vis de t lerie C Axe de charni re D Opercules du conduit d vacuation E Conduit horizontal REMARQUE Si la bouche de d charge murale est situ e directement derri re le connecteur de conduit on doit veiller emp cher toute interf rence entre les clapets du connecteur et de la bouche de d charge murale En cas d interf rence supprimer le clapet du connecteur de conduit mg cas d utilisation d un conduit circulaire fixer le raccord de transition achat s par au sommet de la hotte l aide de vis de t lerie Soulever la hotte sous le placard et d terminer sa position d installation finale en la centrant sous le placard Sur la face inf rieure du placard marquer l emplacement des 4 trous de montage sur la hotte Placer la hotte part sur une surface couverte A Trou en forme de serrure l aide d un foret de Ys 3 mm percer 4 avant trous tel qu illustr A Per age des avant trous Installer les 4 vis de montage 4 5 x 13 mm dans les avant trous Laisser un espace d environ 1 4 6 4 cm entre les t tes des vis et le placard pour faire glisser la hotte et la mettre en place 0 1 1 4 6 4 mm Acheminer le c ble d alimentation du domicile selon les prescriptions du Code national de l lectricit ou des normes CSA et des codes et r glements locaux La longueur du c blage depuis le tabl
14. lectrique 27 68 6 cm 30 76 2 cm au dessus de la surface de cuisson au gaz E Bouche de d charge murale Calcul de la longueur effective du circuit d vacuation Pour calculer la longueur effective du circuit d vacuation n cessaire additionner les longueurs quivalentes pieds m tres de tous les composants utilis s dans le syst me Syst me de d charge circulaire de 6 15 2 cm ou plus Bouche de d charge murale O pi de 6 15 2 cm ou plus 3 x 10 8 3 cm x 25 4cm 4 Coude a 90 de 3 x 10 5 pi 8 3 cm x 25 4 cm sur 6 15 2 cm ou plus 5 pi sur 6 15 2 cm ou plus 1 4 m 2 Exemple de syst me de d charge Bouche de d charge murale coude 90 6 pi 1 8 m EN 2 pi 0 6 m Composant Conduit rond Coude 45 2 5 pi 0 8 m Coude 90 5 pi 1 5 m Longueur maximale recommand e 50 pi 15 2 m 1 coude 90 5 pi 1 5 m 1 bouche de d charge murale 0 pi 0 m section droite de 8 pi 2 4 m 8 pi 2 4 m Longueur du syst me de dia 13 pi 8 9 m 7 17 8 cm Syst me de d charge de 3 x 10 8 3 cm x 25 4 cm Composant Coude 90 de 3 x 10 5 pi 1 5 m 8 3 cm x 25 4 cm Coude plat de 31 4 x 10 12 pi 8 3 cm x 25 4 cm 3 7 m Bouche de d charge murale 0 pi de 3 x 10 8 3 cm x 0 m 25 4 cm lt S2 19 Exemple de syst me de d charge Coude de 3 1 4 x 10 8 3 x 25 4
15. pour l assemblage de la hotte Placer le mat riau de protection sur cette surface 4 l aide d au moins 2 personnes soulever la hotte et la placer l envers sur une surface couverte 5 Si le fond du placard forme une cavit ajouter des tringles d appui en bois de chaque c t Installer les vis pour fixer les tringles d appui aux emplacements indiqu s 20 Tringles d appui en bois seulement pour fond de 3 placard avec cavit 7 6 cm D terminer l emplacement du trou de passage du cable Percer seulement un trou de passage de 1 4 3 2 cm de diam tre pour le c blage Voir l tape 2 pour des instructions sur l emplacement du trou de passage du c blage 1 D terminer et tracer l axe central vertical sur le mur et le placard dans la zone o le passage du conduit d vacuation sera r alis A Axe central 2 C blage travers le sommet du placard Tracer une ligne de distance A partir de la droite de l axe central sur la face inf rieure du placard Sur cette ligne marquer le point situ a 194 4 4 cm du mur arri re Percer en ce point un trou de 1 3 2 cm de diam tre travers le placard i 1 4 4 cm i partir du mur et non i du cadre du placard Axe central A 10 27 6 cm 3 Passage du cable a travers le mur Tracer une ligne de distance A a partir de la droite de l axe central sur la face inf rieure du mur Marquer
16. shown must be used Given dimensions provide minimum clearance Consult the cooktop range manufacturer installation instructions before making any cutouts m Grounded electrical outlet is required See Electrical Requirements section The hood is factory set for vented installations All openings in ceiling and wall where range hood will be installed must be sealed For Mobile Home Installations The installation of this range hood must conform to the Manufactured Home Construction Safety Standards Title 24 CFR Part 328 formerly the Federal Standard for Mobile Home Construction and Safety title 24 HUD Part 280 or when such standard is not applicable the standard for Manufactured Home Installation 1982 Manufactured Home Sites Communities and Setups ANSI A225 1 NFPA 501A or latest edition or with local codes Product Dimensions 124 cm 291346 LE i a _ 3 8 cm 58 cm Installation Clearances A 18 45 7 cm min clearance upper cabinet to countertop B 24 61 0 cm min for electric cooking surfaces 27 68 6 cm min for gas cooking surfaces 30 76 2 cm suggested max bottom of range hood to cooking surface C 30 76 2 cm min cabinet opening width D 13 33 0 cm cabinet depth E 36 91 4 cm base cabinet height Cold Weather Installations An additional back draft damper should be installed to minimize backward cold air flow and a th
17. 0 8 3 x 25 4 cm sur 6 15 2 cm ou plus de diam tre pour utilisation avec circuit d vacuation d un diam tre de 6 15 2 cm ou plus m 3 connecteurs homologation UL Pour placards avec cavit au fond m Deux tringles d appui de largeur 2 5 1 cm Longueur et paisseur selon les dimensions de l encastrement m Quatre vis bois t te plate ou vis m taux avec rondelles et crous pour la fixation des tringles d appui TOTORX est une marque d pos e de Acument Intellectual Properties LLC IMPORTANT Observer les dispositions de tous les codes et r glements en vigueur m C est l installateur qu incombe la responsabilit de respecter les distances de s paration exig es sp cifi es sur la plaque signal tique de l appareil La plaque signal tique est situ e l int rieur de la hotte sur la paroi gauche m Installer la hotte de cuisini re distance de toute zone expos e des courants d air comme fen tres portes et bouches de chauffage m Respecter les dimensions indiqu es pour les ouvertures d couper dans les placards ces dimensions tiennent compte des valeurs minimales des d gagements de s paration Avant d effectuer des d coupages consulter les instructions d installation fournies par le fabricant de la table de cuisson cuisini re m doit disposer d une prise de courant lectrique reli e la terre Voir la section Sp cifications lectriques m Lahotte a t
18. 6 2 cm max sugg r C Largeur minimale de l ouverture du placard de 30 76 2 cm D Profondeur de placard 13 33 cm E Hauteur de placard du bas 36 91 4 cm Le syst me d vacuation doit d charger l air l ext rieur Ne pas terminer le conduit d vacuation dans un grenier ou dans un autre espace ferm m pas utiliser une bouche de d charge murale de 4 10 2 cm normalement utilis e pour un quipement de buanderie m Utiliser un conduit m tallique rond de 6 15 2 cm ou plus de diam tre ou un conduit m tallique rectangulaire de 374 x 10 8 3 cm x 25 4 cm Un conduit en m tal rigide est recommand L utilisation d un conduit de plastique ou en feuille m tallique est d conseill e m Lalongueur du syst me d vacuation et le nombre de coudes doit tre r duit au minimum pour fournir la meilleure performance Pour un fonctionnement efficace et silencieux m pas utiliser plus de trois coudes 90 m Veiller ce qu il y ait une section droite de conduit de 24 61 0 cm au minimum entre deux coudes si on doit utiliser plus de un raccord coud Ne pas installer 2 coudes ensemble Au niveau de chaque jointure du conduit de d charge assurer l tanch it avec les brides de serrage pour conduit m Lesyst me d vacuation doit comporter un clapet Si la bouche de d charge murale ou par le toit comporte un clapet ne pas utiliser le clapet fourni avec la hotte de cuisini re m
19. CTIONS NOTE It is recommended that the vent system be installed before hood is installed Before making cutouts make sure there is proper clearance within the ceiling or wall for exhaust vent 1 Disconnect power Determine Wiring Hole Location Cut only one 1 3 2 cm diameter wiring access hole See Step 2 for wiring hole location instructions 1 Determine and clearly mark a vertical centerline on the wall 2 Determine which venting method to use roof or wall 3 Select a flat surface for assembling the range hood Place covering over that surface 4 Lift the range hood and set it upside down onto covered surface 5 If cabinet has recessed bottom add wood filler strips on each side Install screws to attach filler strips in locations shown Wood filler strips recessed cabinet ottoms only 3 7 6 cm Cabinet bottom 3 7 6 cm Wall and cabinet in the area the vent opening will be made A Centerline To wire through top Mark a line distance A from the right of the centerline on the underside of the cabinet Mark the point on this line that is 194 4 4 cm from back wall Drill a 1 4 3 2 cm diameter hole through the cabinet at this point 1 4 4 cm from wall not cabinet frame E Centerline A 10 27 6 cm 3 To wire through wall Mark a line distance A from the right of the centerline on the underside of the wall Mark the point on this l
20. N IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW WHIRLPOOL SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS SO THESE EXCLUSIONS OR LIMITATIONS MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE OR PROVINCE TO PROVINCE If outside the 50 United States and Canada contact your authorized Whirlpool dealer to determine if another warranty applies If you need service first see the Troubleshooting section of the Use amp Care Guide After checking Troubleshooting you may find additional help by checking the Assistance or Service section or by calling Whirlpool In the U S A call 1 800 253 1301 In Canada call 1 800 807 6777 9 07 Keep this book and your sales slip together for future h z Dealer name reference You must provide proof of purchase or installation date for in warranty service Address T Write down the following information about your major appliance to better help you obtain assistance or service if you ever need it Phone number You will need to know your complete model number and serial number You can find this info
21. OITS JURIDIQUES SPECIFIQUES ET VOUS POUVEZ EGALEMENT JOUIR D AUTRES DROITS QUI PEUVENT VARIER D UNE JURIDICTION UNE AUTRE Si vous r sidez l ext rieur du Canada et des 50 tats des tats Unis contactez votre marchand Whirlpool autoris pour d terminer si une autre garantie s applique Si vous avez besoin de service voir d abord la section D pannage du Guide d utilisation et d entretien Apr s avoir v rifi la section D pannage de l aide suppl mentaire peut tre trouv e en v rifiant la section Assistance ou service ou en appelant Whirlpool Aux E U composer le 1 800 253 1301 Au Canada composer le 1 800 807 6777 2 09 Conservez ce manuel et votre re u de vente ensemble pour Nom du marchand r f rence ult rieure Pour le service sous garantie vous devez pr senter un document prouvant la date d achat ou Adresse d installation K Inscrivez les renseignements suivants au sujet de votre gros Num ro de t l phone appareil m nager pour mieux vous aider obtenir assistance ou Service en cas de besoin Vous devrez connaitre le num ro de mod le et le num ro de s rie au complet Vous trouverez ces renseignements sur la plaque signal tique situ e sur le produit Num ro de modele _ Num ro de s rie Date d achat W10320576A 2010 Whirlpool Corporation 8 10 All rights reserved Registered Trademark TM Trademark of Whirlpool U S A Whirlpool Canada LP Licensee in Ca
22. an Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 m 120 Volt 60 Hz AC only 15 amp fused electrical circuit is required If the house has aluminum wiring follow the procedure below 1 Connect a section of solid copper wire to the pigtail leads 2 Connect the aluminum wiring to the added section of copper wire using special connectors and or tools designed and UL listed for joining copper to aluminum Follow the electrical connector manufacturer s recommended procedure Aluminum copper connection must conform with local codes and industry accepted wiring practices Wire sizes and connections must conform with the rating of the appliance as specified on the model serial rating plate The model serial plate is located behind the filter on the rear wall of the range hood Wire sizes must conform to the requirements of the National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances INSTALLATION INSTRU
23. around the cap area Venting Methods Vent system can terminate either through the roof or wall Use 314 x 10 8 3 x 25 4 cm with a maximum vent length of 35 ft 10 7 m or 6 15 2 cm or larger round vent with a maximum length of 50 ft 15 2 m for vent system NOTE Flexible vent is not recommended Flexible vent creates back pressure and air turbulence that gently reduces performance Roof Venting A E NS B Ed SS A 6 15 2 cm or larger round vent or a 31 4 x 10 8 3 x 25 4 cm rectangular vent through roof B Round vent use 6 15 2 cm or larger round damper purchased separately C Round vent use 314 x 10 8 3 x 25 4 cm to 6 15 2 cm or larger diameter transition piece purchased separately D 27 68 6 cm 30 76 2 cm above gas cooking surface 24 61 0 cm 30 76 2 cm above electric cooking surface E Roof cap Wall Venting A 6 15 2 cm or larger round vent or a 3A x 10 8 3 x 25 4 cm rectangular vent through the wall B Round vent use 314 x 10 8 3 X 25 4 cm to 6 15 2 cm or larger diameter transition piece purchased separately C x 10 8 3 x 25 4 cm through the wall D 27 68 6 cm 30 76 2 cm above gas cooking surface 24 61 0 cm 30 76 2 cm above electric cooking surface E Wall cap Calculating Vent System Length To calculate the length of the system you need add the equivalent
24. as disponible 10 La d pose et la r installation de votre gros appareil si celui ci est install dans un endroit inaccessible ou n est pas install conform ment aux instructions d installation fournies 11 Les gros appareils m nagers dont les num ros de s rie et de mod le originaux ont t enlev s modifi s ou qui ne peuvent pas tre facilement identifi s La pr sente garantie est nulle si le num ro de s rie d usine a t modifi ou enlev du gros appareil m nager Le co t d une r paration ou d un remplacement dans le cadre de ces circonstances exclues est la charge du client CLAUSE D EXON RATION DE RESPONSABILIT AU TITRE DES GARANTIES IMPLICITES LIMITATION DES RECOURS LE SEUL ET EXCLUSIF RECOURS DU CLIENT DANS LE CADRE DE LA PR SENTE GARANTIE LIMIT E CONSISTE EN LA R PARATION PR VUE CI DESSUS LES GARANTIES IMPLICITES Y COMPRIS LES GARANTIES APPLICABLES DE QUALIT MARCHANDE ET D APTITUDE UN USAGE PARTICULIER SONT LIMIT ES UN AN O LA PLUS COURTE P RIODE AUTORIS E PAR LA LOI WHIRLPOOL N ASSUME AUCUNE RESPONSABILIT POUR LES DOMMAGES FORTUITS OU INDIRECTS CERTAINES JURIDICTIONS NE PERMETTENT PAS L EXCLUSION O LA LIMITATION DES DOMMAGES FORTUITS O INDIRECTS OU LES LIMITATIONS DE LA DUR E DES GARANTIES IMPLICITES DE QUALIT MARCHANDE OU D APTITUDE UN USAGE PARTICULIER DE SORTE QUE CES EXCLUSIONS O LIMITATIONS PEUVENT NE PAS S APPLIQUER DANS VOTRE CAS CETTE GARANTIE VOUS CONFERE DES DR
25. e 3 Les r parations lorsque le gros appareil m nager est utilis des fins autres que l usage unifamilial normal ou lorsque les instructions d installation et ou les instructions de l op rateur ou de l utilisateur fournies ne sont pas respect es 4 Les dommages imputables accident modification usage impropre ou abusif incendie inondation actes de Dieu installation fautive ou installation non conforme aux codes d lectricit ou de plomberie ou l utilisation de pi ces consomptibles ou de produits nettoyants non approuv s par Whirlpool 5 Les d fauts apparents notamment les raflures les bosses fissures ou tout autre dommage au fini du gros appareil m nager moins que ces dommages soient dus des vices de mat riaux ou de fabrication et soient signal s Whirlpool dans les 30 jours suivant la date d achat 6 Toute perte d aliments due une d faillance du r frig rateur ou du cong lateur 7T Les co ts associ s au transport du gros appareil m nager du domicile pour r paration Ce gros appareil m nager est concu pour tre r par domicile et seul le service domicile est couvert par la pr sente garantie 27 8 Les r parations aux pi ces ou syst mes r sultant d une modification non autoris e faite l appareil 9 Les frais de transport pour le service d un produit si votre gros appareil est situ dans une r gion loign e o un service d entretien Whirlpool autoris n est p
26. e 2 Retirer la vis du cabochon et retirer le cabochon B A Vis B Cabochon C Lampe fluorescente 3 Retirer l ampoule de la douille et la remplacer par une ampoule fluorescente de 120 volts 13 watts maximum 50 pour un culot GX24 4 R installer le cabochon et la vis Serrer la vis 5 Reconnecter la source de courant lectrique Si la nouvelle lampe ne fonctionne pas v rifier que chaque lampe est correctement ins r e dans sa douille avant de demander l intervention d un d panneur 25 SCH MA DE C BLAGE NEU Terre L JANE N Filtre interf rences o lectro mag 2 Po zi Ri i lt j aL 5 m Ballast BU ji gu z m 1020304050607 Z JANE Lu El Terre Ch ssis 3 Terre R seau lectriqug ND BL R R sistance du moteur Ohms Rouge Noir Caract ristiques du moteur Ource d alimentation 120 VCA lectrique EJ Fr quence T i Demande E E i d nergie Bab i _ T i 12 uF BL 26 ASSISTANCE OU SERVICE Lors d un appel pour assistance ou service veuillez conna tre la date d achat le num ro de mod le et le num ro de s rie complets de l appareil Ces renseignements nous aideront mieux r pondre votre demande Si vous avez besoin de pi ces de rechange Si vous avez besoin de commander des pi ces de rechange nous vous recommandons d employer uniquement les pi ces sp cifi es pa
27. eau de distribution avec fusibles ou disjoncteurs doit tre suffisante pour r aliser facilement le raccordement dans le boitier de connexion de la hotte REMARQUE Ne pas mettre le syst me sous tension avant d avoir compl tement termin l installation Oter les 2 vis du couvercle du bo tier de connexion Faire ensuite glisser le couvercle vers le bord externe de la hotte pour placer l extr mit large des trous de forme allong e sur les pattes de montage A Vis B Pattes de montage C Couvercle du bo tier de connexion Pointer le couvercle du bo tier de connexion vers la t te de la vis pour le retirer Retirer le couvercle du bo tier de connexion et le mettre de c t n A Couvercle du bo tier de connexion ter l opercule pour le passage de l alimentation lectrique du sommet ou de l arri re de la hotte de ventilation selon l emplacement du c ble d alimentation lectrique du domicile et installer un serre c ble de Y homologu UL ou CSA A Opercule pour le passage de l alimentation lectrique l aide d au moins deux personnes soulever la hotte et la placer son emplacement final Ins rer suffisamment de c ble lectrique travers le serre c ble de Y homologation UL ou CSA pour tablir les connexions avec la bo te de connexion Serrer les vis du serre c ble Positionner les trous allong s de la hotte par dessus la t te des vis de montage Puis pousser la hotte
28. ectrica Support Motor Resistance Ohms Red Black 55 BK Motor Characteristics Power Supply 120 VAC gt Power li R 144 Watts 9 Epa n T5 he T i 12 uF 12 ASSISTANCE OR SERVICE When calling for assistance or service please know the purchase date and the complete model and serial number of your appliance This information will help us to better respond to your request If you need replacement parts If you need to order replacement parts we recommend that you use only factory specified parts Factory specified parts will fit right and work right because they are made with the same precision used to build every new appliance To locate factory specified replacement parts in your area call us or your nearest designated service center Call the Whirlpool Customer eXperience Center toll free 1 800 253 1301 Our consultants provide assistance with m Features and specifications on our full line of appliances Installation information Use and maintenance procedures Accessory and repair parts sales Specialized customer assistance Spanish speaking hearing impaired limited vision etc m Referrals to local dealers repair parts distributors and service companies Whirlpool designated service technicians are trained to fulfill the product warranty and provide after warranty service anywhere in the United States To locate the Whirlpool designated service co
29. ed many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean ADANGER AWARNING All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed IMPORTANT SAFETY INSTRUCTIONS You can be killed or seriously injured if you don t immediately follow instructions You can be killed or seriously injured if you don t follow instructions WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING m Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer Before servicing or cleaning the unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction Do not operate any fan with a damaged
30. ed to accumulate on fan or filter m Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING m SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT NEVER PICK UP A FLAMING PAN you may be burned DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use an extinguisher ONLY if You know you have a class ABC extinguisher and you already know how to operate it The fire is small and contained in the area where it started The fire department is being called You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFPA mg WARNING To reduce the risk of fire or electrical shock do not use this fan with any solid state speed control device READ AND SAVE THESE INSTRUCTIONS INSTALLATION REQUIREMENTS Gather the required tools and parts before starting installation Read and follow the instructions provided with any tools listed here Tools needed Drill 1 3 0 cm drill bit Ye 3 0 mm drill bit for pilot holes Pencil Wire stripper or utility knife Tape measure or ruler Caulking gun and weatherproof caulkin
31. entral sur le mur 3 Utiliser une scie sauteuse ou une scie guichet pour d couper l ouverture rectangulaire du syst me d vacuation dans le mur Avant du placard i Y 0 9 3 i 5 4 9 8 cm i 13 3 21 Style 2 D coupages d ouverture pour un conduit rectangulaire de 34 x 10 8 3 x 25 4 cm sur raccord de transition rond D charge travers le toit D coupage d une ouverture rectangulaire de 414 x 1072 10 8 cm x 26 7 cm sur la face inf rieure du bas du placard 1 Tracer des lignes Y 1 3 cm et 4 12 1 cm du mur arri re sur l axe central de la face inf rieure du placard 2 Tracer des lignes 5 13 3 cm de part et d autre de l axe central sur la face inf rieure du placard 3 Utiliser une scie sauteuse ou une scie guichet pour d couper l ouverture rectangulaire pour le passage du conduit d vacuation y 13 3 cm 13 3 cm partir du mur et non du cadre du placard D coupage d une ouverture circulaire sur la face inf rieure du sommet du placard 1 Tracer un axe central sur la face inf rieure du sommet du placard 2 Tracer une ligne de 5 12 7 cm en partant du mur arri re sur la face inf rieure du sommet du placard 3 Utiliser un compas ou un gabarit circulaire pour tracer un cercle avec un diam tre de 1 4 0 64 cm sup rieur celui du conduit d vacuation 4 Utiliser une scie sauteuse ou une scie g
32. erating Failure to do so can result in death or electrical shock 1 Disconnect power 10 A B C D A White wires B Black wires C UL listed wire connector D Green or bare and yellow green ground wire E Home power supply cable F UL listed or CSA approved Y strain relief 2 Use UL listed wire connectors and connect white wires A together 3 Use UL listed wire connectors and connect black wires B together AWARNING Electrical Shock Hazard Electrically ground blower Connect ground wire to green and yellow ground wire in terminal box Failure to do so can result in death or electrical shock 4 Connect green or bare ground wire from home power supply to yellow green ground wire C in terminal box using UL listed wire connectors 5 Reinstall terminal box cover 6 Check that the light bulb is secure in its socket See Replacing the Fluorescent Lamp in the Range Hood Care section 7 Reconnect power 1 Replace grease filters See the Range Hood Care section 2 Check the operation of the range hood fan and light See Range Hood Use section If range hood does not operate check to see whether a circuit breaker has tripped or a household fuse has blown Disconnect power and check wiring connections NOTE To get the most efficient use from your new range hood read the Range Hood Use section RANGE HOOD USE The range hood is designed to remove smoke
33. ermal break should be installed to minimize conduction of outside temperatures as part of the vent system The damper should be on the cold air side of the thermal break The break should be as close as possible to where the vent system enters the heated portion of the house Makeup Air Local building codes may require the use of make up air systems when using ventilation systems greater than specified CFM of air movement The specified CFM varies from locale to locale Consult your HVAC professional for specific requirements in your Vent system must terminate to the outdoors Do not terminate the vent system in an attic or other enclosed area Do not use a 4 10 2 cm laundry type wall cap Use a 6 15 2 cm or larger round metal vent or a 3 x 10 8 3 x 25 4 cm rectangular metal vent Rigid metal vent is recommended Plastic or metal foil vent is not recommended m The length of vent system and number of elbows should be kept to a minimum to provide efficient performance For the most efficient and quiet operation m Use no more than three 90 elbows m Make sure there is a minimum of 24 61 cm of straight vent between the elbows if more than 1 elbow is used Do not install 2 elbows together Use clamps to seal all joints in the vent system The vent system must have a damper If roof or wall cap has a damper do not use damper supplied with the range hood m Use caulking to seal exterior wall or roof opening
34. feet meters for each vent piece used in the system 6 15 2 cm or Larger Round Vent System Vent Piece Round 45 elbow 2 5 ft 0 8 m 90 elbow 5 0 ft 1 5 m 6 15 2 cm or larger 0 0 ft wall cap 0 0 m 3 x 10 8 3 cm x 25 4cm 4 5 ft to 6 15 2 cm or larger 1 4 m 314 x 10 8 3 cm x 25 4 5 0 5 6 k Y gt 3 x 10 8 3 cm x 25 4 cm Vent System Vent Piece 3 x 10 8 3 cm x 25 4 5 0 ft 90 elbow 1 5 m 3 x 10 8 3 cm 25 4 12 0 ft flat elbow 3 7 m 374 x 10 8 3cmx25 4cm 0 0ft e S2 G to 6 15 2 cm or larger 1 5 m 90 elbow Example vent system Wall 90 elbow lt eft 1 8m gt all cap 2 ft 0 6 m Maximum Recommended Length 50 ft 15 2 m 1 90 elbow 5 0 ft 1 5 m 1 wall cap 0 0 ft 0 0 m 8 ft 2 4 m straight 8 0 ft 2 4 m Length of 7 17 8 cm system 13 0 ft 3 9 m wall cap 0 0 m Example vent system 314 x 10 8 3 x 25 4 cm Sina 6 ft 1 8m x Wall cap 0 6 m Maximum Recommended Length 35 ft 10 7 m 1 90 elbow 5 0 ft 1 5 m 8 ft 2 4 m straight 8 0 ft 2 4 m 1 wall cap 0 0 ft 0 0 m Length of 3 x 10 8 3 cm x 25 4 cm 13 0 ft 3 9 m system Observe all governing codes and ordinances Ensure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadi
35. g compound Flat blade screwdriver Phillips screwdriver Saber or keyhole saw Vent clamps Metal snips Compass or 8 20 3 cm circle template Parts supplied Remove parts from package Check that all parts are included 2 Metal filters 6 3 5 x 9 5 mm mounting screws 3 4 5 x 13 mm damper screws 31 4 x 10 8 3 x 25 4 cm damper vent connector T 20 Torx adapter Parts needed m 3 x 10 8 3 x 25 4 cm or 6 15 2 cm or larger round metal venting m 6 15 2 cm or larger round damper if using 6 15 2 cm or larger round vent system m 3 x 10 8 3 x 25 4 cm to 6 15 2 cm or larger diameter transition piece if using 6 15 2 cm or larger diameter round vent system m 3 ULlisted wire connectors For cabinets with recessed bottoms m Two 2 6 1 cm wide filler strips Length and thickness determined by recess dimensions m Four flat head wood screws or machine screws with washers and nuts to attach filler strips TOTORX is a registered trademark of Acument Intellectual Properties LLC 4 IMPORTANT Observe all governing codes and ordinances m Itis the installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located inside the range hood on the left wall m Range hood location should be away from strong draft areas such as windows doors and strong heating vents m Cabinet opening dimensions that are
36. ic damage including scratches dents chips or other damage to the finish of your major appliance unless such damage results from defects in materials or workmanship and is reported to Whirlpool within 30 days from the date of purchase 6 Any food loss due to refrigerator or freezer product failures 7T Costs associated with the removal from your home of your major appliance for repairs This major appliance is designed to be repaired in the home and only in home service is covered by this warranty 8 Repairs to parts or systems resulting from unauthorized modifications made to the appliance 9 Expenses for travel and transportation for product service if your major appliance is located in a remote area where service by an authorized Whirlpool servicer is not available 10 The removal and reinstallation of your major appliance if it is installed in an inaccessible location or is not installed in accordance with published installation instructions 11 Major appliances with original model serial numbers that have been removed altered or cannot be easily determined This warranty is void if the factory applied serial number has been altered or removed from your major appliance The cost of repair or replacement under these excluded circumstances shall be borne by the customer DISCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REMEDIES CUSTOMER S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR AS PROVIDED HEREI
37. id ice EU iicet eb co Gre a Rene REPAS 13 WARRANTY nn tenir nea ia 14 TABLE DES MATI RES S CURIT DE LA HOTTE DE CUISINI RE 15 EXIGENCES D INSTALLATION 17 Outils et pi ces are o edad 17 Exigences d emplacement 17 Exigences concernant l vacuation 18 Sp cifications lectriques 20 INSTRUCTIONS D INSTALLATION 20 Pr paration de l emplacement 20 Installation de la hotte 22 Raccordement lectrique 24 Achever l installation 24 UTILISATION DE LA HOTTE 25 Commandes de la hotte de cuisini re 25 ENTRETIEN DE LA HOTIE 25 Nettoyage as al uuu a Sia 25 SCHEMA DE C BHAGE uu 26 ASSISTANCE OU SERVICE 27 58 amp u u ER 27 ng ze 27 RANGE HOOD SAFETY Your safety and the safety of others are very important We have provid
38. ine that is 3 4 1 9 cm from the underside of the cabinet Drill a 174 3 2 cm diameter hole through the rear wall at this point Y i Centerline A 107 27 6 cm Style 1 Cut Openings for 3 4 x 10 8 3 cm 25 4 cm Rectangular Vent System Roof Venting To make 4 x 10 10 8 cm x 26 7 cm rectangular cutout on the underside of cabinet top and bottom 1 Mark lines 1 2 1 3 cm and 4 12 1 cm from the back wall on the centerline of the underside of cabinet 2 Mark lines 51 4 13 3 cm to the right and left of the centerline on the underside of cabinet 3 Use saber or keyhole saw to cut a rectangular opening for vent 4 Repeat steps 1 3 for the underside of the top of the cabinet From wall not cabinet frame Wall Venting To make a 3 x 10 8 9 cm x 26 7 cm rectangle in the wall 1 Make 2 lines by measuring 0 9 cm and 37 9 8 cm down from underside of cabinet and mark on the centerline on the back wall 2 Mark lines 51 4 13 3 cm to the right and left of the centerline on the wall 3 Use saber or keyhole saw to cut a rectangular opening in the wall for the vent Cabinet front i 4 1 Y i 0 9 cm i 3 i 5 9 8 cm i 13 3 em Style 2 Cut Openings for 3 x 10 8 3 x 25 4 cm Rectangular Vent to Round Vent Transition Roof Venting To make 41 4 x 1012 10 8 cm x 26 7 cm rectangular cutout on the underside of cabinet bottom
39. minal box NOTE Do not reconnect power until the installation is complete 6 Remove the screws from the terminal box cover Then slide the cover toward the outside edge of range hood to position the large end of the keyhole slots over the mounting tabs gt y lt lt A Screws B Mounting tabs C Terminal box cover 7 Tip the terminal box cover at the screw flange area to remove Remove the terminal box cover and set it aside n A Terminal box cover 8 Remove the power supply knockout from the top or rear of the vent hood depending on the incoming location of your home power supply cable and install a UL Listed or CSA approved Y strain relief A Power supply knockout 9 Using 2 or more people lift the hood into final position Feed enough electrical wire through the 7 UL listed or CSA approved strain relief to make connections in the terminal box Tighten the strain relief screws 10 Position the range hood so that the large end of the keyhole slots are over the mounting screws Then push the hood toward the wall so that the screws are in the neck of the slots Tighten the mounting screws making sure the screws are in the narrow neck of slots 11 Connect ventwork to hood Seal joints with clamps to make secure and airtight 12 Check that back draft dampers work properly AWARNING Electrical Shock Hazard Disconnect power before servicing Replace all parts and panels before op
40. mpany in your area you can also look in your telephone directory Yellow Pages For further assistance If you need further assistance you can write to Whirlpool Corporation with any questions or concerns at Whirlpool Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence Call the Whirlpool Canada LP Customer eXperience Centre toll free 1 800 807 6777 Our consultants provide assistance with m Features and specifications on our full line of appliances m Use and maintenance procedures W Accessory and repair parts sales Referrals to local dealers repair parts distributors and service companies Whirlpool Canada LP designated service technicians are trained to fulfill the product warranty and provide after warranty service anywhere in Canada For further assistance If you need further assistance you can write to Whirlpool Canada LP with any questions or concerns at Customer eXperience Centre Whirlpool Canada LP 200 6750 Century Ave Mississauga Ontario L5N 0B7 Please include a daytime phone number in your correspondence Stainless Steel Cleaner and Polish Order Part Number 31462A 13 WHIRLPOOL CORPORATION MAJOR APPLIANCE WARRANTY LIMITED WARRANTY For one year from the date of purchase when this major appliance is operated and maintained according to instructions attached to or furnished wi
41. nada Printed in Mexico Tous droits r serv s Marque d pos e TM Marque de commerce de Whirlpool U S A emploi sous licence par Whirlpool Canada LP au Canada Imprim au Mexique
42. nt lectrique A B C D 1 R installer les filtres graisse Voir la section Entretien de la hotte 2 Contr ler le fonctionnement du ventilateur de la hotte et de la lampe Voir la section Utilisation de la hotte A Conducteurs blancs B Conducteurs noirs C Connecteur de fils homologation UL D Conducteurs verts ou nus ou verts jaunes de Si la hotte ne fonctionne pas d terminer si un disjoncteur liaison la terre S est ouvert ou si un fusible du domicile est grill E C ble d alimentation lectrique du domicile D connecter la source de courant lectrique et inspecter les F Serre c ble de 2 homologation UL ou CSA connections du c blage 2 Connecter ensemble les conducteurs blancs A l aide de REMARQUE Pour pouvoir tirer le plus grand parti de la nouvelle connecteurs de fils homologation UL hotte de cuisini re lire la section Utilisation de la hotte 3 Connecter ensemble les conducteurs noirs B l aide de connecteurs de fils homologation UL 24 UTILISATION DE LA HOTTE La hotte de cuisini re est con ue pour extraire fum e vapeurs de cuisson et odeurs de la zone de la table de cuisson Pour obtenir les meilleurs r sultats mettre la hotte en marche avant d entreprendre une cuisson et la laisser fonctionner pendant plusieurs minutes apr s l ach vement d une cuisson pour pouvoir vacuer de la cuisine toute odeur de cuisson ou fum e Les commandes de la hotte se trouve
43. nt sur le panneau avant droit de la hotte A C _ e D B A Logement pour lampe fluorescente B Poign e du filtre graisse C Commandes du ventilateur et de l clairage D Filtre graisse 9909 A Bouton d clairage On Off marche arr t B Bouton d arr t de ventilateur et de vitesse minimale C Bouton de vitesse mod r e de ventilateur D Bouton de vitesse maximale de ventilateur Pour faire fonctionner la lampe Le bouton d clairage On Off contr le les lampe Appuyer une fois sur le bouton pour allumer la lampe puis une nouvelle fois pour l teindre Utilisation du ventilateur Les boutons BLOWER SPEED vitesse du ventilateur activent le ventilateur et contr lent la vitesse du ventilateur et le niveau sonore pour un fonctionnement silencieux On peut modifier la vitesse tout moment pendant le fonctionnement du ventilateur en appuyant sur le bouton correspondant la vitesse souhait e Appuyer une deuxi me fois sur le bouton BLOWER OFF arr t ventilateur pour arr ter le ventilateur ENTRETIEN DE LA HOTTE IMPORTANT Nettoyer fr quemment la hotte et les filtres graisse en suivant les instructions suivantes R installer les filtres graisse avant de faire fonctionner la hotte Surfaces externes IMPORTANT Ne pas utiliser de tampons de r curage savonneux de nettoyants abrasifs de cr me polir pour table de cuisson de laine d acier de chiffons de lavage rugueux
44. ou d essuie tout Pour viter d endommager les surfaces en acier inoxydable ne pas utiliser de nettoyants contenant du chlore Les produits de nettoyage ne doivent pas contenir de chlore Des dommages peuvent survenir M thode de nettoyage m Frotter dans la direction du grain pour viter d gratigner ou d endommager la surface m Nettoyant et poli pour acier inoxydable Pi ce n 31462A non inclus Voir la section Assistance ou service pour commander m D tergent liquide ou nettoyant tout usage Rincer l eau propre et s cher avec un chiffon doux sans charpie mg Nettoyant vitre pour liminer les traces de doigts Filtre graisse m tallique Retirer chaque filtre en tirant sur la poign e ressort puis en tirant le filtre vers le bas A Poign e ressort 2 Laver le filtre m tallique selon le besoin au lave vaisselle ou avec une solution de d tergent chaude 3 R installer le filtre en s assurant que les poign es ressort sont orient es vers l avant Ins rer le filtre d aluminium dans la rainure sup rieure Enfoncer la poign e ressort 5 Pousser le filtre m tallique vers le haut et rel cher la poign e pour l emboiter 6 R p ter les tapes 1 5 pour l autre filtre gt Remplacement d une lampe fluorescente Interrompre l alimentation de la hotte attendre le refroidissement de la lampe fluorescente 1 D connecter la source de courant lectriqu
45. ou de choc lectrique ne pas utiliser ce ventilateur avec un quelconque dispositif de r glage de la vitesse semi conducteurs LIRE ET CONSERVER CES INSTRUCTIONS EXIGENCES D INSTALLATION Rassembler les outils et composants n cessaires avant d entreprendre l installation Lire et observer les instructions fournies avec chacun des outils de la liste ci dessous Outils n cessaires Perceuse 1 foret de 1 1 4 3 cm Foret de Ys 3 mm pour avant trous Crayon Pince d nuder ou couteau utilitaire M tre ruban ou r gle Pistolet calfeutrage et compos de calfeutrage r sistant aux intemp ries Tournevis lame plate Tournevis Phillips Scie sauteuse ou scie guichet Brides pour conduit Cisaille de ferblantier Compas ou gabarit circulaire de 8 20 3 cm Pi ces fournies Retirer les pi ces de l emballage V rifier que toutes les pi ces sont pr sentes m 2 filtres m talliques m 6 vis de montage de 3 5 x 9 5 mm m 3 vis de clapet de 4 5 x 13 mm Module clapet connecteur de conduit de 31 4 x 10 8 3 x 25 4 cm m Adaptateur Torx T 20 Pi ces n cessaires Installations avec d charge l ext rieur m Conduit m tallique rond de 31 4 x 10 8 3 x 25 4 cm ou d un diam tre de 6 15 2 cm ou plus m Clapet anti reflux de 6 15 2 cm ou plus de diam tre pour utilisation avec un circuit d vacuation de 6 15 2 cm ou plus de diam tre m Raccord de transition de 3 x 1
46. per flap NOTE The exhaust adaptor damper can be installed up to 1 2 5 cm on either side of the hood center to accommodate off center ductwork m f using rectangular vent attach rectangular damper vent connectors to the range hood using sheet metal screws A Vertical vent B Sheet metal screws C Hinge pin D Vent knockouts E Horizontal vent NOTE If the wall cap is directly behind the vent connector the dampers in the connector and wall cap must not interfere with each other Remove the vent connector damper if they interfere m f using round vent attach vent transition piece purchased separately to range hood top using sheet metal screws 2 Lift the range hood up under cabinet and determine final location by centering beneath cabinet Mark on the underside of cabinet the location of the 4 keyhole mounting slots on the range hood Set range hood aside on a covered surface A A Keyhole slot 3 Use 3 mm drill bit and drill 4 pilot holes as shown A Drill pilot hole 4 Install the 4 4 5 mm x 13 mm mounting screws in pilot holes Leave about 1 4 6 4 cm space between screw heads and cabinet to slide range hood into place 1 4 6 4 mm 5 Run the home power supply cable according to the National Electric Code or CSA standards and local codes and ordinances There must be enough wiring from the fused disconnect or circuit breaker box to make the connection in the hood electrical ter
47. r l usine Les pi ces sp cifi es par l usine conviendront et fonctionneront bien parce qu elles sont fabriqu es avec la m me pr cision utilis e dans la fabrication de chaque nouvel appareil Pour localiser les pi ces sp cifi es par l usine dans votre r gion nous appeler ou t l phoner au centre de service d sign le plus proche Veuillez appeler sans frais le Centre pour l eXp rience de la client le de Whirlpool Canada LP au 1 800 807 6777 Nos consultants vous renseigneront sur les sujets suivants m Caract ristiques et sp cifications sur toute notre gamme d appareils lectrom nagers Consignes d utilisation et d entretien Ventes d accessoires et de pi ces de rechange R f rences aux marchands locaux aux distributeurs de pi ces de rechange et aux compagnies de service Les techniciens de service d sign s par Whirlpool Canada LP sont form s pour remplir la garantie des produits et fournir un service apr s la garantie partout au Canada Pour plus d assistance Si vous avez besoin de plus d assistance vous pouvez soumettre par crit toute question ou pr occupation Whirlpool Canada LP l adresse suivante Whirlpool Canada LP Centre pour l eXp rience de la client le 200 6750 Century Ave Mississauga Ontario L5N 0B7 Veuillez inclure dans votre correspondance un num ro de t l phone o l on peut vous joindre dans la journ e Nettoyant et poli pour acier inoxydable Commander la pi
48. rmation on the model and serial number label located on the product Model number Serial number Purchase date 14 S CURIT DE LA HOTTE DE CUISINI RE Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez vous de toujours lire tous les messages de s curit et de vous y conformer Voici le symbole d alerte de s curit Ce symbole d alerte de s curit vous signale les dangers potentiels de d c s et de blessures graves vous et d autres Tous les messages de s curit suivront le symbole d alerte de s curit et le mot DANGER ou AVERTISSEMENT Ces mots signifient Risque possible de d c s ou de blessure grave si vous ne DAN G E suivez pas imm diatement les instructions Risque possible de d c s ou de blessure grave si vous AVERTISSEM ENT ne suivez pas les instructions Tous les messages de s curit vous diront quel est le danger potentiel et vous disent comment r duire le risque de blessure et ce qui peut se produire en cas de non respect des instructions 15 16 IMPORTANTES INSTRUCTIONS DE S CURIT AVERTISSEMENT POUR R DUIRE LE RISQUE D INCENDIE CHOC LECTRIQUE OU DOMMAGES CORPORELS RESPECTER LES INSTRUCTIONS SUIVANTES m Utiliser cet appareil uniquement dans les applications envisag es par le fabricant Pour toute question contacter le
49. steak au poivre flamb Nettoyer fr quemment les ventilateurs d extraction Veiller ne pas laisser la graisse s accumuler sur les surfaces du ventilateur ou des filtres Utiliser toujours un ustensile de taille appropri e Utiliser toujours un ustensile adapt la taille de l l ment chauffant AVERTISSEMENT POUR R DUIRE LE RISQUE DE DOMMAGES CORPORELS APR S LE D CLENCHEMENT D UN FEU DE GRAISSE SUR LA CUISINI RE APPLIQUER LES RECOMMANDATIONS SUIVANTES m Placer sur le r cipient un couvercle bien ajust une t le biscuits ou un plateau m tallique POUR TOUFFER LES FLAMMES puis teindre le br leur VEILLER VITER LES BRULURES Si les flammes ne s teignent pas imm diatement VACUER LA PI CE ET APPELER LES POMPIERS m NE JAMAIS PRENDRE EN MAIN UN R CIPIENT ENFLAMME vous risquez de vous br ler m NE PAS UTILISER D EAU ni un torchon humide ceci pourrait provoquer une explosion de vapeur br lante m Utiliser un extincteur SEULEMENT si ll s agit d un extincteur de classe ABC dont on connait le fonctionnement 1 s agit d un petit feu encore limit l endroit o il s est d clar Les pompiers ont t contact s ll est possible de garder le dos orient vers une sortie pendant l op ration de lutte contre le feu Recommandations tir es des conseils de s curit en cas d incendie de cuisine publi s par la NFPA m AVERTISSEMENT Pour r duire le risque d incendie
50. th the product Whirlpool Corporation or Whirlpool Canada LP hereafter Whirlpool will pay for Factory Specified Parts and repair labor to correct defects in materials or workmanship Service must be provided by a Whirlpool designated service company This limited warranty is valid only in the United States or Canada and applies only when the major appliance is used in the country in which it was purchased Outside the 50 United States and Canada this limited warranty does not apply Proof of original purchase date is required to obtain service under this limited warranty ITEMS EXCLUDED FROM WARRANTY This limited warranty does not cover 1 Service calls to correct the installation of your major appliance to instruct you on how to use your major appliance to replace or repair house fuses or to correct house wiring or plumbing 2 Service calls to repair or replace appliance light bulbs air filters or water filters Consumable parts are excluded from warranty coverage 3 Repairs when your major appliance is used for other than normal single family household use or when it is used in a manner that is contrary to published user or operator instructions and or installation instructions 4 Damage resulting from accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with electrical or plumbing codes or use of consumables or cleaning products not approved by Whirlpool 5 Cosmet
51. the surface m Stainless Steel Cleaner and Polish Part Number 31462A not included See Assistance or Service section to order m Liquid detergent or all purpose cleaner Rinse with clean water and dry with soft lint free cloth m Glass cleaner to remove fingerprints Metal Grease Filter Remove each filter by pulling the spring release handle then pulling down the filter A Spring release handle 2 Wash metal filters as needed in dishwasher or hot detergent solution 3 Reinstall the filter by making sure the spring release handles are toward the front Insert aluminum filter into upper track 4 Push in spring release handle Push up on metal filter and release handle to latch into place 6 Repeat steps 1 5 for the other filter a Replacing a Fluorescent Lamp Turn off the range hood and allow the fluorescent lamp to cool 1 Disconnect power 2 Remove the screw from the lens cover and remove the cover B A Screw B Lens cover C Fluorescent lamp 3 Remove the light from the socket and replace with a 120 volt 13 watt maximum 50 fluorescent light for GX24 base 4 Replace the lens cover and screw Tighten the screw 5 Reconnect power If new light does not operate make sure the lamp is inserted correctly before calling service 11 WIRING DIAGRAM N anp L W Y G BK EMI Filter 9 z Ballast BU i i s BU al LJ 1020304050607 GND GND Chassis El
52. uichet pour d couper l ouverture circulaire pour le passage du conduit d vacuation Ouverture pour le conduit circulaire E Ouvertures l d coup es dans le placard partir du mur et non du cadre du placard 22 Installation du conduit d vacuation 1 Installer le conduit d vacuation travers l ouvertures d coup e dans le placard mural ou le mur Achever l installation du syst me d vacuation conform ment la m thode d vacuation s lectionn e Voir la section Exigences concernant l vacuation 2 l aide d un produit de calfeutrage assurer l tanch it autour de la bouche de d charge l ext rieur travers le mur ou le toit Achever la pr paration 1 Oter les filtres graisse Voir la section Entretien de la cuisini re m Selon votre installation retirer l opercule rectangulaire sup rieur ou arri re du conduit d vacuation Si l on utilise un conduit d vacuation rond retirer l opercule arrachable rectangulaire sup rieur m Veiller ce que le pivot du clapet soit le plus proche possible du bord sup rieur arri re de la hotte m Enlever le ruban adh sif du volet du clapet REMARQUE Le clapet adaptateur d vacuation peut tre install jusqu 1 2 5 cm de chaque c t du centre de la hotte pour pouvoir installer les conduits d centr s m Sil on utilise un conduit rectangulaire fixer les connecteurs rectangulaires du clapet conduit
53. un point sur cette ligne qui se trouve 3 4 1 9 cm de la face inf rieure du placard Percer en ce point un trou de 1 3 2 cm de diam tre travers la paroi arri re Le 1 9 cm Y Axe central A 107 27 6 cm Style 1 D coupages d ouverture pour un syst me d vacuation rectangulaire de 3 4 x 10 8 3 cm x 25 4 cm D charge travers le toit D coupage d une ouverture rectangulaire de 41 x 1012 10 8 cm x 26 7 cm sur la face inf rieure du sommet et du bas du placard 1 Tracer des lignes Y 1 3 cm et 424 12 1 cm du mur arri re sur l axe central de la face inf rieure du placard 2 Tracer des lignes 5 13 3 cm de part et d autre de l axe central sur la face inf rieure du placard 3 Utiliser une scie sauteuse ou une scie guichet pour d couper l ouverture rectangulaire pour le passage du conduit d vacuation 4 R p ter les tapes 1 3 pour la face inf rieure du sommet du placard a Ouvertures d coup es dans le placard A 13 3 cm partir du mur et non du cadre du placard vacuation par le mur D coupage d une ouverture rectangulaire de 372 x 1072 8 9 cm x 26 7 cm dans le mur 1 Mesurer 2 lignes de 0 9 cm et 3 9 8 cm en descendant partir de la face inf rieure du placard et marquer leur emplacement sur l axe central du mur arri re Tracer des lignes 574 13 3 cm de part et d autre de l axe c
54. vers le mur pour engager la partie troite des trous sur les vis de fixation Serrer les vis de montage en s assurant que les vis sont dans la partie troite des trous de fixation des vis Raccorder le circuit d vacuation la hotte Assurer l tanch it des jointures avec des brides pour conduits 12 V rifier que les clapets anti retour fonctionnent correctement 23 AVERTISSEMENT AVERTISSEMENT D Risque de choc lectrique 2 D connecter la source de courant lectrique avant Risque de choc lectrique l entretien Beller le ventilateur a Replacer pi ces et panneaux avant de faire la remise Brancher le fil reli la terre au fil vert et jaune reli en marche la terre dansla boite de Ta ROME Le non respect de ces instructions peut causer Le non respect de ces instructions peut causer un un d c s ou un choc lectrique d c s ou un choc lectrique 4 l aide des connecteurs de fils homologation UL connecter 1 D connecter la source de courant lectrique le conducteur de liaison la terre vert ou nu du c ble d alimentation du domicile au conducteur vert jaune de E liaison la terre C dans le boitier de connexion 5 Installer le couvercle du boitier de connexion 6 V rifier que l ampoule d clairage est bien fix e dans leur douille Voir Remplacement d une lampe fluorescente la section Entretien de la hotte 7 Reconnecter la source de coura