Home
SPT UC-030B Use and Care Manual
Contents
1. ST Mini Electronic Pulse Massager UC 030B Operating Manual Contents tod CON 0 E AE TA AE A 2 D AOL MN AL NGS kasa v a aaa E EMME EM ae cotes 3 Partie mun on aa 4 Operating TS UN Sii li ii eee AAA AR 5 6 Prostam SCHEMA CS aaa A R til lan 7 8 Recommended USC DOIG alana ar AAA AAA 9 O 9 WW AITA II OA aa Dada 10 Introduction UC 030B Mini Electronic Pulse Massager 1s a pain relief product which delivers electric impulses to tired and sore muscles These impulses are generated by the device and delivered through the connecting wires and electrodes to the target body areas The impulses mimic the action potential coming from the central nervous system to trigger contraction of the muscle UC 030B is portable compact and stylish in design It may help relief pain in various parts of the body such as the lower back shoulders joints hands and feet Using UC 030B properly will provide you with a healthy and comfortable life Features of UC 030B Mini Electronic Pulse Massager 1 e dd dis W Liguid crystal display LCD with battery usage indictor Build in rechargeable lithium battery DC 3 7V Freguency 0 200 Hz Main unit measure 1 69 x 0 51 x 3 30 inches Net weight of the main unit 1 2 oz 075 Ib Six massaging modes Adjustable intensity and up to 60 minutes countdown timer Massage slippers and belts connect to the Mini Massager Accessories included 1 pair of slipper 2 belts 6 bands 4 electr
2. it will power off 5 seconds after a session completes To begin another session first switch the power button to OFF position and back to ON Recommended practices Duration of 20 minute for each body area Frequency of 1 2 times per day per area Start from the lowest intensity and gradually adjust to a comfortable level on a scale level from to 1 to 10 Be sure the area to be treated is free of perspiration dirt and abrasions Good skin care is important for a comfortable use of device Be sure the treatment site 1s clean of dirt and body lotion wipe with an alcohol pad if needed When removing the pads remove by pulling in the direction of hair growth The electrode pads are disposable and should be replaced when they lose their adhesiveness However keeping electrode pads clean will extend their lifespan Replace pads to the storage holder immediately after use Avoid touching with fingertips due to grease on fingertips The lifespan of the pads will vary depending on the frequency of use To purchase additional pads please contact Sunpentown at 1 800 330 0388 and ask for part number PAD 029 Program Schematics k l Knead ng 45 E Acupuncture a 3 OF Tapping Cupping 3 riz Massage Mode off Time 15 On Tine 205 850 5 On Tine 95 850 5 Tapping Mode SN001 E E amp o On Tine 205 18M5 Scraping Mode off Time 1 850MS 850 5 On Ti
3. ms e Sunpentown must be notified of the fault e Proof of purchase must be presented to Sunpentovvn s nominated representative e warranty will be void if the product if modified misused or repaired by an unauthorized person e The warranty after repair will not be extended beyond the original one year period e All replacement parts will be new or reconditioned e Parts which are replaced become the property of Sunpentown e The warranty applies for the use of the product in the USA only What is NOT COVERED e Warranty does not include freight charges e Incidental or consequential damage caused by possible defects with this product e Damage to product caused by improper power supply voltage accident fire floods or acts of nature e Failure of product resulting from unauthorized modifications to the product e Improper installation or failure to perform the necessary maintenance This GUARANTEE is in addition to your Statutory Rights SUNPENTOWN INTERNATIONAL INC 14625 Clark Ave City of Industry CA 91745 Tel 800 330 0388 service sunpentown com www sunpentown com 10
4. ne 95 On Tine 10 107 850MS 18MS 850 5 enor Cupping Mode Kneading Mode On Tine 95 Recommended use points Recommended massage points Troubleshooting If your device 1s not operating properly please check below for common problems and suggested solutions If the recommended action does not solve the problem please contact Sunpentown Customer Service at 1 800 330 0388 or service sunpentown com Stimulation is weak or non existent e Be sure skin is clean and pads are firmly attached to skin Be sure the pads are not touching each other Check wire connection and make sure lead wires are securely plugged in Unit s battery is low and needs to be recharged Both pads of the same wire must be attached to one person s body in order to feel sensation Devise does not turn on e Check if battery is low and needs to be recharged e If unit was previously used switch the power switch to OFF first then back to ON Electrode pads are not sticky e The pads will lose adhesiveness over use please contact Sunpentown for replacements Skin turns red e Extended treatment on the same area stop and wait or treat another area e Ji problem persists contact your physician Srl Your Guarantee If this product is found to be faulty as a result of faulty materials or workmanship within one year from date of purchase it will be repaired free of charge This guarantee is subject to the following ter
5. o the EMC information provided Portable and mobile radio frequency RF communication equipment can affect Medical Electrical Equipment Operating temperature range 32 F to 118 F Operating humidity 10 to 85 Atmospheric pressure 400hPa to 1060hPa Part Identification 1 USB port 2 On off switch 3 LCD screen 4 Channel outlets 5 Intensity adjustment 6 Mode selector 7 Timer adjustment 8 Play Pause button 9 USB charger 10 USB cable 11 Electrode pads 12 Lead wires 1 Magnets 2 Hook and loop 3 Pin holes 4 Snaps 1 amp 2 Hook and loop 3 Snaps Operating Instructions Before initial use charge the massager for a minimum of 8 hours Make sure power switch 1s in the OFF position before you connect pad slipper or belt ELECTRODE PAD E 2 Connect lead wire s by inserting the plug into the Left and or Right channel outlets Connect electrode pads to lead wires by snapping them on This should be done before applying pads to the skin 3 Place pads to treatment areas such as shoulder or lower back make sure pads do not touch each other Press down firmly and ensure a full and firm contact with skin 4 Switch the power switch to ON position 5 Press the M mode button to select desired massage mode 6 Press the button to increase massage intensity Pressing the button would decrease massage intensity 7 During a massage session pressing the center PII button would pa
6. ode pads 2 lead wires USB adapter 1 USB cable and 2 wire pad holders Safety warnings If you have one of the following conditions please consult with your physician before purchasing or using this device Acute disease malignant tumor infective disease pregnant heart disease high fever abnormal blood pressure lack of skin sensation or an abnormal skin condition any condition requiring the active supervision of a physician Do not use this unit if you are using an implanted electronic medical device such as a pacemaker or other life maintaining device Do not use this unit if you are wearing electronic medical devices for monitoring health functions Do not use this device while driving Do not use this device while sleeping Do not use this device in high humidity areas such as bathroom Keep this device out of reach of children Stop using this device at once if you feel pain discomfort dizziness or nausea and consult your physician Do not attempt to move the electrode pads while the device is operating Turn off the device before moving or removing the electrode pads Do not use the device around the heart on the head mouth pudendum or blemished skin areas Keep the device away from wet high temperature and or direct sunlight place Medical Electrical Equipment needs special precautions regarding electromagnetic compatibility EMC and needs to be installed and put into service according t
7. use the operation Press again to resume 8 Press the T timer button to set massage time up to 60 minutes in 10 minute increments SLIPPERS 1 Snap on the lead wire to the slippers 2 Connect the lead wire to unit s left or right channel outlet 3 Place feet into the slippers 4 Switch the power switch to ON position 5 Press the M mode button to select desired massage mode 6 Press the button to increase massage intensity Pressing the button would decrease massage intensity 7 During a massage session pressing the center PII button would pause the operation Press again to resume 8 Press the T timer button to set massage time up to 60 minutes in 10 minute increments MASSAGE BANDS Oe ae Snap the lead wires to massage belt Choose the appropriate band and affix to desired body part waist thigh arm etc Connect the lead wire s to unit s left and or right channel outlet Switch the power switch to ON position Press the M mode button to select desired massage mode Press the button to increase massage intensity Pressing the decrease massage intensity During a massage session pressing the center PII button would pause the operation Press again to resume Press the T timer button to set massage time up to 60 minutes in 10 minute increments 66 66 button would Note Timer continues to count down even when session 1s paused To conserve battery un